| Date: 12/19/2007 | Time: | Report ID: Sam 1 |
| Property: 333 Wild Rasberry Lane Etowah, NC |
Customer: Sample Buyer |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building. Not Present items will be noted only in the Report and will NOT be in the Summary. Please read the entire report and consider items or components that are not present.
Repair = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Investigate = refers to a system or component that needs additional investigation by a specialist to determine if repairs are needed.
In Attendance: Customer and their agent | Type of building: Single Family (1 story) | Approximate age of building: Over 25 Years |
Temperature: Over 65 | Weather: Clear | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Water Test: No | Radon Test: No |
| Styles & Materials Foundation: Masonry block Method used to observe Crawlspace: Crawled Floor Structure: 2 X 8 2 X 10 Wood joists Wall Structure: Wood Masonry Columns or Piers: Masonry block Supporting walls Ceiling Structure: 2X4 Roof Structure: Engineered wood trusses 2 X 4 Rafters Plywood Roof-Type: Gable Method used to observe attic: Walked Attic info:
Scuttle hole |
||||||||||||||||||||||||||||||||||||||||
1.0 (1)
White efflorescence (powder substance) on block wall indicates moisture is in contact with the masonry. This does not necessarily indicate that intrusion will occur. I recommend
checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the block if necessary. Efflorescence is
found on many homes without water intrusion occurring inside the home. But, it should alert you to the possibility that future steps may be needed.
(2)
Water signs on cedar wall and trim. Also a mold like substance on carpet
at lower level and under stairs. I did not inspect or test for mold and I am
unable to determine if water intrusion occurs.
![]() | ![]() |
![]() | ![]() |
(3)
Visible signs of water intrusion in the crawlspace (along front of home) are
present from dampness along the block wall. I am unable to determine the
extent of intrusion or how often it occurs. Cross ventilation may help as
the crawls has no ventilation. I recommend further investigation or
correction by a qualified licensed contractor or water infiltration specialist.
Refer to the diagram as a guide if a drainage system is needed.![]() | ![]() |
1.1
There is a horizontal crack(s) in the foundation wall at the left side (facing
front). These cracks do not appear significant to require repairs at this
time. This is my opinion and you should seek a second opinion by a
qualified person. ![]() | ![]() |
1.5
Leak signs in attic perhaps or likely from the old roof as this newer roof
appears in tact. I am unable to determine if leak exists due to no recent
rain.![]() | ![]() |
| Styles & Materials Siding Style: RB&B (Reverse board and batten) Siding Material: Wood Exterior Entry Doors: Wood Appurtenance: Deck with steps Covered porch Driveway: Concrete Garage Door Type: Two automatic Garage Door Material:
Compressed board Wood |
||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
2.1
Patio doors at rear of home are cloudy or seal is broken. Glass panes that
have lost their seal (cloudy) can usually be replaced without replacing the
entire unit. A qualified contractor should inspect and repair as needed.![]() |
2.2
The trim stop for fixed pane is weathered and indicates that water
may be getting below trim. I recommend a paintable sealant be
applied and paint trim.![]() |
2.3 (1)
The step tread on steps on the deck at the rear of home are deteriorated. A
repair or replacement is needed. A skilled masonry contractor should
perform the work.
A handrail may be needed
![]() |
(2)
The 2x6 decking on the deck at the rear of home has several boards that
are deteriorated. A general replacement is likely. A qualified contractor
should determine whether a repair or replacement is needed.
![]() | ![]() |
2.4
The concrete drive at the front of home is is pitted in areas and has
settlement cracks. Further deterioration can occur if not repaired. A
qualified contractor should inspect and repair as needed.![]() |
2.6 (1)
Old propane tank in ground and is discontinued. I did not determine if gas
remains in discontinued tank? I recommend further investigation by a
qualified person.![]() |
(2)
There is an odd configuration in ground under addition in crawlspace.
This may be an old well? I am unable to determine. I recommend a
qualified well drilling company or plumber investigate further to determine
if any further action is needed to correct.![]() |
2.7
The automatic openers for two-door garage at the front of home will not
reverse when met with resistance. Doors that will not reverse when met
with resistance can kill a child or pet. A qualified contractor should
inspect and repair as needed. The sensors are in place for garage
door(s) and will reverse the door.
| Styles & Materials Roof Covering: Architectural Viewed roof covering from: Walked roof Sky Light(s): One Chimney (exterior):
Brick |
||||||||||||||||||||||||||||||
3.0 (1)
The tree limbs that are in contact with roof or hanging near roof should be
trimmed.![]() | ![]() |
(2)
Shingles loose under eave at front of home, needs adhesive.![]() |
3.3
The gutter needs cleaning of debris at the virtually all areas where gutters
are installed. Gutters that drain poorly or clogged can lead to many costly
problems such as deterioration of fascia, soffit or roof edge. It can also
cause gutters to pull loose and lead to possible water intrusion. A
qualified person should repair or replace as needed.![]() |
| Styles & Materials Water Source: Well Water Filters: Sediment filter (We do not inspect filtration systems) Plumbing Water Supply (into home): PVC Plumbing Water Distribution (inside home): Copper PEX Washer Drain Size: 2" Diameter Plumbing Waste: PVC Cast iron Water Heater Power Source: Electric Water Heater Capacity: 40 Gallon (1-2 people) Manufacturer:
A.O. SMITH |
|||||||||||||||||||||||||||||||||||||||||||||
4.0 (1)
The basket strainer had leaked and corrected itself for the time being at
the Kitchen sink. Repairs are needed. A qualified person should repair as
necessary.
![]() |
(2)
The tub drain drains slowly under the hall bath. Repairs are needed. A
qualified person should repair as necessary.
4.1 (1)
The control knob leaks at the hall bath. Repairs are needed. A qualified
licensed plumber should repair or correct as needed.![]() |
(2)
Brown deposits are on the plumbing fixtures which indicates a filter may
be needed. Filter in place and appears dirty but I am unable to determine if
you need a different or additional filter. I did not test water for bacteria or
other. I recommend contacting a water filtration company.![]() |
(3)
I recommend the well head lid
be insulated better before winter. FYI![]() |
4.2
The wiring for the water heater missing romex connector. Electrical issues
are considered a hazard until repaired. I recommend a licensed electrician
correct as necessary.![]() | ![]() |
![]() |
| Styles & Materials Electrical Service Conductors: Below ground Panel capacity: 200 AMP Panel Type: Circuit breakers Electric Panel Manufacturer: GENERAL ELECTRIC Branch wire 15 and 20 AMP: Copper Wiring Methods:
Romex |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.3 (1)
The wall switch is broken (unsafe) at the upstairs closet for air handler.
At least two outlets are broken at LR and entry way. Electrical issues
are considered a hazard until repaired. A qualified licensed electrician
should perform repairs that involve wiring.
![]() |
(2)
Several loose wire ends needs placing inside a box with a cover-plate in the basement at the pressure tank of well. I recommend
repair as needed.![]() | ![]() |
(3)
Wall switch on ceiling in Garage, purpose unknown
![]() |
| Styles & Materials Heat Type: Heat Pump Forced Air (also provides cool air) Energy Source: Electric Number of Heat Systems (excluding wood): Two Ductwork: Insulated Filter Type: Disposable Types of Fireplaces: Conventional Operable Fireplaces: One Number of Woodstoves:
None |
||||||||||||||||||||||||||||||||||||||||||||||||||
6.3 (1)
The washable filter is collapsed and needs replacing at upstairs. The
filter needs replacing with a rigid frame to prevent filter from falling out
of alignment. ( Picture 1 ) The filter in basement ( Picture 2 ) needs
replacement and in crawlspace which is difficult to access due to the
crawlspace ( Picture 3 ). A qualified person should repair or replace as
needed
![]() | ![]() |
![]() |
(2)
The supply duct pipe or main plenum is failing in the crawlspace. Energy
loss is occurring in crawlspace and immediate correction is needed. A
licensed HVAC contractor should service or repair unit.
![]() | ![]() |
![]() | ![]() |
| Styles & Materials Cooling Equipment Type: Heat Pump Forced Air (also provides warm air) Cooling Equipment Energy Source: Electricity Number of AC Only Units:
Two |
||||||||||||||||||||||||||||||
![]() | ![]() |
![]() | ![]() |
![]() |
| Styles & Materials Ceiling Materials: Sheetrock Wall Material: Sheetrock Floor Covering(s): Carpet Hardwood T&G Tile Vinyl Interior Doors: Hollow core Window Types: Double-hung Casement Cabinetry: Wood Veneer Countertop:
Composite |
|||||||||||||||||||||||||||||||||||||||||||||
8.1
The tissue holder on the wall is damaged at the master bath. I recommend
repair as necessary.
![]() |
8.2 (1)
The Baseboard is missing at the upstairs (right of hall bath). Repairs are
needed. A qualified contractor should inspect and repair as needed.![]() |
(2)
Tile at shower pan and wall surround are loose and missing mortar or
grout and sealer at the upstairs bath. Repairs are needed to prevent water
damage to shower/bath. A qualified person should repair or replace as
needed.![]() | ![]() |
8.6
Four windows will not operate properly and may involve
repair to linkage of crank handles and one cloudy (lost seal) at
the upstairs Bedroom (right of hall bath) and room left of hall
bath and at washer dryer off kitchen. A qualified contractor
should inspect and repair as needed.
| Styles & Materials Attic Insulation: Fiberglass R-19 Ventilation: Gable vents Soffit Vents Exhaust Fans: Fan Dryer Power Source: 220 Electric Dryer Vent: Flexible Vinyl Floor System Insulation:
Unfaced R-19 |
||||||||||||||||||||||||||||||||||||||||
9.4
The Exhaust fan does not vent to outside at the hall bath and
master bath. Vent pipes should terminate outside and not in the
attic. Many homes have their vent pipe poised at the roof vent
such as yours. It is up to you to determine whether or not this
is a concern or needs further consideration from a general
contractor. A qualified contractor should inspect and repair as
needed.
![]() | ![]() |
9.5
Wall switch for room fan in wall has been removed. It is inoperable.
![]() | ![]() |
| Styles & Materials Dishwasher Brand: KENMORE Disposer Brand: IN SINK ERATOR Exhaust/Range hood: JENN AIR Range/Oven: JENN AIR Built in Microwave:
KENMORE |
||||||||||||||||||||||||||||||||||||||||

18 Business Park Circle
Arden, NC 28704
877-274-4299
Customer
Sample Buyer
Address
333 Wild Rasberry Lane
Etowah, NC
2. Exterior |
||||||||||||||||||||||||||||||||
|
3. Roofing |
||||||||||||||
|
4. Plumbing |
||||||||||||||||||||||
|
5. Electrical System |
||||||||
|
6. Heating |
||||||||
|
8. Interiors |
||||||||||||||||||||
|
9. Insulation and Ventilation |
||||||||||||
|

18 Business Park Circle
Arden, NC 28704
877-274-4299
Customer
Sample Buyer
Address
333 Wild Rasberry Lane
Etowah, NC
1. Structural Components |
||||||||||||||||||||||
|
2. Exterior |
||||||||
|
4. Plumbing |
||||||
|
5. Electrical System |
||||||
|