#HG TEMPLATE - EDIT BY HAND WITH EXTREME CARE #last modified on : 1/3/03 3:27:11 PM #last modified by : Russell Buchanan license #306 #comment : NOTE: To look at this template, select it and then select print to preview it's appearance. This template exceeds the Standards of organizations such as ASHI, NAHI, CREIA, AII, HIF, and state licensing boards such as NC, SC. A Detailed Itemized Breakdown of Components except the rooms are not broken down individually. Instead, all the rooms fit into one section "Interiors". firstButton=Exterior secondButton=Interior connectors . is are Also, and also at on above all or under near , . col Yes, Y, 0, 1, 0 INSPECTED, IN, 0, 1, 0 No, N, 0, 1, 0 REPAIR OR REPLACE, RR, 1, 1, 0 NOT PRESENT, NP, 0, 1, 0 NOT INSPECTED, NI, 1, 1, 0 EXCLUDE, X, 0, 0, 1 SUMMARY, S, 1, 0, 0 text 2783, Wood mantle 2771, linkage 2759, is not secured properly. Frame and surface area should be cleaned before re-seating with mortar 2754, Screen curtains 2720, is sealed off. We did not inspect further 2697, is no longer controlled by thermostat. A manual switch was installed. Recommend restoring control back to thermostat 2669, is slow to work 2666, is wired wrong at wall switch (heat works fan and fan works heat) 2662, has a damaged light cover 2659, and needs cleaning or possible repair or replacement 2657, window 2656, Chimney 2648, Squirrel 2640, Active bee nest (large) 2576, was tested for leaks and failed. Recommend repair or replace 2537, has loose wiring and needs repair 2519, Oven door handle 2499, Front left coil element 2497, is exposed at plug 2476, did not heat. Needs repair or replace 2426, missing crank handles 2423, needs lock hardware repaired or replaced 2404, under sink edge 2385, at bar 2379, (right of refrigerator) 2377, (right of sink) 2370, is unfinished 2293, Ceiling joists or framing may be effected (not visible) 2276, Downstairs 2271, Shoemold 2220, 44 2207, 77 2196, 66 2185, 55 2175, that the upper level unit 2160, Excessive condensation 2112, Filter access cover 2095, has failed 2089, is damaged, needs replacing 2070, left of stairs 2060, No liner 2040, has a small hairline crack. Masonry and mortar behind liner appear good. However, most chimney sweep contractors will insist on replacing liner before considering chimney to be safe to use 2035, has about 1/8 inch creosote. Recommend cleaning at 1/4 inch thick. Due to the creosote, we could not visually inspect liner for hairline cracks 2028, works but knob is broken or stripped 2021, (no fuel) 2006, on electric baseboard 1988, but bellowed smoke 1918, Gas odor 1916, Shut-off valve 1899, is missing a cap and can be turned on inadvertently 1895, is leaning and should be level and secure 1879, is single (for gravity feed) and furnace is higher than oil line. This means when barrel gets low, it may not push oil to furnace. A duel line and a pump may be needed 1878, located underground 1852, is wrong material for piping. Material must be Copper, Galvanized, CPVC, PEX or Poly 1840, uses an extension cord and should have it's own outlet 1831, drain valve 1804, was empty during inspection and circuit breaker was off. We did not inspect for proper operation or leaks 1771, is "double trapped" which can create an air lock. Needs correcting by licensed plumber 1763, is rusted or deteriorated 1748, under half bath 1741, Plumbing waste line 1740, has an open joint that needs a cap to prevent sewer gas or leakage 1735, has been temporarily repaired 1729, plastic fittings 1718, Recommend contacting the installer or a water filtration company 1685, Existing 1 1/2" diameter drain line 1671, may over run on newer washing machines (stronger pump). If so, recommend a 2" diameter drain line with trap and vent 1666, Stop-valve 1654, leaks at connection to waste line under sink 1644, will not tighten securely 1622, under guest bath 1618, is PVC material and not allowed 1617, is crimped or kinked 1604, Hot supply line 1579, partially clogged, needs repair or replace 1568, Spray nozzle 1560, was turned "off" before inspection 1516, Lower Level Bath 1492, Toilet seat 1483, defective (grounded, but wont trip with test-plug) 1454, is a "three-prong" grounded outlet which is good. However, it should be upgraded to a GFCI outlet with an exterior cover 1445, Timer control 1440, Basement entry door 1408, chain is broke 1401, "wobbles" 1386, (for wall outlets) 1376, Guest Bath 1365, Guest Bedroom 1364, Master Bedroom 1362, Washer/Dryer Room 1358, upstairs 1349, works even when tripped, which is currently not a true GFCI outlet. Needs correcting 1346, clogged or obstructed with paint or debris 1331, missing romex connector 1294, Romex wiring 1291, Open splice 1290, Melted wiring 1279, in covered porch 1270, needs light fixture installed 1260, missing coverplate 1256, top of stairs 1239, is missing cover (DANGEROUS) 1207, back porch 1206, front porch 1203, bathroom 1200, door was locked (no key). 1184, 20amp 1180, Wood in contact with wire splices 1154, Amateur wiring installation, 1108, fails to remove all areas of water intrusion 1092, table legs 1073, Window(s) 1071, need leaves or debris removed 985, Sub-flooring 959, are missing joist hangers or ledger strips 937, No repairs needed at present 933, stair step 923, No additional repairs needed at this time 905, missing mortar 899, above Garage 889, Electrical wiring in attic was not secured to wood members properly, and was not installed neatly or in 90 degree turns as standard 887, needs electrical splice placed inside access panel, or install inside a box with coverplate 868, Discontinued air handler 839, The structural integrity does not appear to have been compromised 814, around passive vent 811, around chimney flue piping 792, needs a guard rail with proper picket spacing around stairwell 745, in Guest bath 716, at left side 700, Hidden bee 694, appears dead and could pose a danger 643, to be re-surfaced with concrete 629, lower level 624, has electronic sensors located higher than six inches off floor. Needs relocating per manufacturers recommendations 596, is damaged at wood trim 590, has a damaged screen 567, damaged at brick mold trim 559, is warped and does not fit opening properly when closed 551, damaged at weather-stripping 500, all shutters 486, Ledgers 449, loose, and needs tightened or fastened securely 446, balcony 442, Ceiling panels 440, Sheetrock on ceiling 431, are torn or damaged in areas 412, needs a guard rail with proper picket spacing (4" max between pickets recommended) 393, Decorative column (s) 391, Support post (s) 389, Stone wall (s) 385, Top plates of guard rail 372, Tar and gravel floor 353, has loose tile and mortar (small area), and needs repair 339, needs cleaning with a deck wash and seal with a waterproof sealant 330, loose, and needs tighten or re-fastened 276, damaged. Needs repair or replace as necessary 235, needs cleaning of debris 232, is clogged 204, Log Siding 168, sun room 164, guest bedroom 146, does not have a proper flash kit installed 144, (facing front) 123, one 91, frost (slippery) 87, Recommend increase ventilation to prolong life of roof 47, The deflection is great enough to need repair or reinforcement 43, Rafters are under-size or span is too far, and a knee wall should be built (in attic) to reinforce roof 38, Dormer 2765, Damper arm 2718, must remain open during use 2702, is using an extension cord for permanent wiring 2678, is loose in crawlspace. Recommend metal flex or rigid pipe when repaired 2674, is exposed and needs placing in conduit 2627, has a paper face and concealed in plastic which can trap moisture and create condensation 2602, is about 13 inches thick or just under 41 R-Value 2594, When new insulation is installed, recommend flipping over old insulation so facing will be towards the heated space. New insulation should be blown in, or rolls without facing 2573, door does not shut properly 2555, Grease filter 2505, Bake element 2459, (to downstairs) 2450, six windows 2442, has a damaged or warped muntin grille (also called divider grille) 2421, (Transom window) 2415, Two windows 2403, Tile Countertop 2392, at dishwasher 2376, (left of sink) 2374, (left of stove) 2341, stairs to basement 2336, Self adhesive tile 2321, Subfloor 2292, is warped or buckled in areas and needs repair. Structural joists remain strong 2252, Brick veneer 2221, 45 2208, 78 2197, 67 2186, 56 2170, Air conditioner 2169, Heat pump in cool mode 2164, Recommend repair as needed to prevent condensation 2150, Electronic air cleaner 2132, at most if not all rooms 2113, Ductpipe 2105, under 2100, is in contact with ground and may deteriorate if not corrected 2077, will need grout and repair where loose 2069, 4th bedroom 2024, Recommend licensed heat contractor inspect 1996, is leaking at Circulation pump 1990, but appearance of flame(s) indicate the need to service 1978, transformer 1974, Fan belt 1939, needs insulation cleaned away from tray to prevent clogging emergency drain tube 1938, indicates that heat input may be inadequate or unit needs repair 1929, is leaking at supply line tap 1920, Cover is missing 1896, is exposed to accidental rupture by vehicle and should be protected 1891, Oil barrel 1867, is loose at a joint connection 1836, was not on. We did not inspect unit for proper operation or for leaks 1827, bottom suggesting a possible replacement 1819, Recommend service if needed 1817, There is a possibility that circuit was inadvertently turned on prior to inspection, or may be turned on after inspection causing damage to elements 1813, is leaning and needs to be secured 1803, is concealed in an insulation jacket. We did not visually examine all of outer casing 1790, outside at meter 1775, had leaked and corrected itself for the time being 1737, is a S trap and needs upgrade to a P trap with an auto-vent 1707, iron deposits on fixtures indicate unit is not working properly 1699, most all faucets 1655, is taped 1629, at water heater 1609, missing aerator 1594, Water filter 1592, Pressure reducing valve 1581, loose at mount and needs securing to sink 1578, clogged, and needs repair or replace 1566, Hot control on faucet 1555, Shower arm 1531, is missing decorative screw cover 1527, is slow to fill when flushed 1525, components do not seal water off properly inside tank 1511, needs glue and seal to wall 1502, Wall mirror 1486, Master bath 1467, Compressor 1456, damaged or defective and needs replacing 1437, pull chain is stuck 1433, uses an extension cord as permanent wiring and needs it's own outlet 1428, in Storage room 1418, outside porch 1399, does not work and 1396, did not work 1387, (for gas fire logs) 1381, "Three-prong" outlets are 1345, located over stove, and considered a potential fire hazard if appliance cords become close to range burners. Suggest relocate or blank-off 1326, at guest bedroom 1314, workshop 1280, in converted room 1271, or more 1214, wire is not attached within five feet of where plumbing line enters home 1192, fuse 1185, 30amp 1166, Extension cord(s) used as permanent, 1165, Edison base fuse(s), 1161, Damaged fuse(s), 1112, is improper 1083, along block wall 1078, Open wall vent 1065, intentionally closed off 1061, will not operate 1059, old 1042, basement 1041, crawlspace 1031, Settlement crack is large 1023, Block pier 992, is amateur 991, is amateur and inadequate 983, Six to Nine 962, half bath 942, I recommend a structural engineer evaluate 883, Exhaust fan 865, Accumulation of discarded junk 859, Roof boards need reinforced (from within attic). This does not require shingle removal 831, (above carport) 815, at lower and upper roof junction wall 786, has a loose handrail 759, needs ladder trimmed at an angle to fit floor properly 674, is leaning and erosion signs are present. This problem will continue to become worse and needs correcting 671, is old and deteriorated in areas, but appears stable at present 637, Garage door of detached building 627, missing retention cables (in case springs break to prevent injury) 609, shows deterioration on bottom of side jambs 605, needs glass replaced where cracked or broken 592, is damaged at panel guides where it attaches to track. Needs a new panel frame 564, needs hardware/knob repair or replacement 560, is damaged at core from what appears to be a forced entry when door was locked 550, pulled loose at spline 527, Reading room 507, Patio doors 496, needs fastened in the middle to reduce warping 495, not painted 493, steps 488, are deteriorated in areas 471, Step-tread 425, shows evidence of water leak from roof above 416, is weak with no footing or loose 409, . Recommend a handrail be installed for safety 382, Guardrails 336, has deteriorated throughout, and needs replacing 291, foundation wall 289, Stone 285, rear deck where siding comes in contact with deck 273, loose, and needs re-nail or tighten 271, gables 265, Wood fascia 209, bricks 199, Wood shingles 197, Cedar siding 193, Composite board siding 190, Wood siding 189, Vinyl siding 188, Masonry chimney 180, Stain 170, has stains indicating a leak did or does exist 155, Five 114, Chimney has been tarred around base. This area will need periodical maintenance 111, is dented or damaged at chimney area. Unable to determine if this area leaks 70, Recommend replace and install roof covering according to standard workmanlike practices 53, failing 34, covered porch 30, missing 12, right dormer 2, side porch, 2785, Mantle 2781, not fastened to supports properly 2778, Mortar 2777, hearth 2751, (left door) 2734, Ash dump lid and frame 2721, is stuffed with insulation. We did not remove to check for proper operation 2707, turned freely with hand which indicates the unit may work, but due to the low temperature the unit would not come on at it's lowest setting. We did not inspect this unit 2705, fan blades is hitting shroud and needs repair or replace 2664, does not vent to outside 2644, Bat or bats seen 2637, replace screen 2633, Passive Vent screens 2632, Recommend remove plastic and secure insulation to joist as necessary 2617, is about 14 inches thick or just at 51 R-Value 2591, Cellulose insulation 2570, is functional, but is old and rusted 2547, is missing. Recommend a 40 watt bulb max 2532, are difficult to read and should be replaced 2531, for oven 2530, for range 2498, is frayed or damaged 2487, Decorative panel on dishwasher door 2486, Gasket around dishwasher door 2478, does not have a wall switch to prevent children from operating 2470, is difficult to read or set, to desired cycle 2453, need adjustment 2443, was not inspected (AC unit installed in window) 2399, was cut out too wide at sink (gap visible) 2355, Veneer 2346, steps in garage 2333, is swollen and weak around toilet 2273, are missing (not installed) 2270, Surround stall 2262, needs silicone caulk at inside corners and at shower pan (floor) perimeter 2259, is loose, 2256, Baseboard 2237, is peeling paint 2233, is peeling or loose 2228, has some "nail pops," and needs repair (cosmetic) 2222, 46 2209, 79 2198, 68 2187, 57 2142, is dirty 2131, is old and open-close feature may no longer work without repair 2117, did not heat from end to end 2114, (no heat source for this room) 2099, is possibly asbestos tape and should be taped over with metal foil duct tape 2084, did not operate 2075, Concrete floor 2047, Fireplace 2046, Woodstove 2043, Recommend a certified chimney Guild inspect 2032, Washer/Dryer room 2016, Wiring splice 2015, Wiring 2012, Wall mounted heater 1980, Pressure relief valve 1921, Cover is damaged 1890, Oil filter 1888, Oil line connection 1883, at splice in crawlspace 1873, is gray in material and may be defective. Manufacturer has ordered a recall on "core-vent" and "ultra-vent." 1841, is noisy indicating a possible problem with fan/bearings 1816, Recommend filling tank until water comes out of hot side of a faucet, before turning breaker on to protect elements 1815, did not work (no hot water). Circuit breaker was already "on" before I inspected. It is possible that circuit was turned on or left on after winterizing causing the elements to fail 1807, missing both panel covers 1806, missing panel cover 1799, rusted 1777, Wasteline 1760, clogged or drains slow 1744, Tub waste and overflow 1742, Tub drain 1730, Faucets 1725, Recommend a licensed plumber to troubleshoot further 1720, unknown 1714, Water Filtration unit 1713, flush unit drain line connects to waste line of home (Cross-Connection) which is improper 1711, appears old. Unable to determine life expectancy 1706, Sediment in water 1691, poor 1689, lever 1684, Cold supply valve 1682, is vinyl material and not allowed when using gas to power dryer. Recommend a metal flex pipe be used 1680, shows repair attempts to prevent drain from overflowing. Needs replacing with 2' diameter drain with a P-Trap and vent 1675, is "double trapped" which can form an air lock. Needs correcting by a licensed plumber 1660, Private Bath sink 1647, Hose bibs 1638, is in place but no longer connected to plumbing (inoperable) 1624, under W/D room 1602, taped (amateur repair) 1598, inoperable 1570, Faucet spout 1554, Gold finish on faucets 1522, leaks at tank mount 1513, has hairline cracks but no leaks during inspection 1504, is damaged and needs replacing 1489, Sink 1487, Lower Level bath 1469, rear entry 1468, side entry 1449, is loose and needs repair 1448, This unit may not perform as intended until repaired or replaced 1441, carport 1392, has a "short" or loose connection 1374, Hall Bath 1339, coverplate 1336, not grounded. Needs correcting 1317, Central Vacuum 1309, thermostatically controlled attic fan 1302, light fixture 1289, Improper wiring 1288, Exposed splice(s) 1284, at pressure tank of well 1264, boxes 1201, it was not installed at time of inspection 1198, cabinetry 1186, 40amp 1146, Service conductors are undersized, 1134, A large portion 1129, Bath 1075, Automatic vents 1022, Concrete pier 1007, appears to work but are considered temporary supports 998, Deterioration is possible. Unable to determine without access 969, (front of home) 954, and floor sags 930, and 927, We did not inspect area(s) 922, Previous repair to wall does not appear adequate 919, Repairs are needed. Recommend a licensed general contractor inspect further 907, missing a proper footing 881, Extension cord used as permanent wiring 862, Boxes and discarded debris 849, Moisture meter was used and readings were around 31% or "wet" indicating leak still exists 848, Moisture Meter was used and readings were 19% or higher indicating leak still exists 801, 2x8 rafters 774, Attic door 770, needs proper hardware to be easily opened 764, is loose and needs to be secured 762, does not reach floor and is not safe 758, no longer shuts tight when closed. Springs could be weak and needs repair or replace 755, needs help to close (pull at right hinge when closing) 754, in storage room 740, at Carport 690, fan wobbles indicating a repair or replacement is needed 675, has some loose rocks, and needs repair 658, Concrete drive 649, loose in areas and needs mortar and repair 636, Four-door garage 632, Automatic opener for 613, (all openers) 597, is damaged at jamb where closure arm pulled loose. Needs repair 594, rubs threshold 583, main entry 568, Main entry door 558, was damaged by pet 553, has a damaged handle and needs replacing 484, Wheel chair ramp 468, Stair Stringers 436, Wood shakes on wall 369, Slate floor 356, has deteriorated mortar or grout, and is loose and uneven in areas 340, Deck band should be properly attached to home with 5/8 bolts according to local standards 338, peeling paint. Recommend prep and use "Porch floor" enamel with sand mixed in last coat 322, . This may allow rodents to enter 318, and needs one installed 301, is deteriorated, 298, does not fit opening properly, 294, at window 286, rear entry to home 283, Brick siding 282, Chimney chase 277, beginning to deteriorate, and needs repair 270, Eave boards 257, (near deck) 203, Cypress siding 196, RVB (reverse board and batten) sheathing 132, One 110, is failing at seams and needs repair or replace 93, no safe means to access. Requires a separate inspection 54, was installed improperly 28, damaged 2753, Glass doors on enclosure 2752, Glass enclosure 2742, Propane gas line 2740, is too long inside fireplace and risks close contact with flames 2691, Dryer cord 2680, has a damaged vent hood outside. Needs repair or replace 2677, does not vent to the outside. Recommend metal flex or rigid pipe when installed 2675, is missing a cut-off valve above floor 2665, "flickers" which indicates a loose connection at wall switch or unit 2646, Mice droppings 2645, Bat droppings 2629, floor in basement 2628, floor in crawlspace 2619, is about 16 inches thick or 58+ R-Value 2608, should be adjusted to maintain a clearance around recessed lights (can -lights) to avoid possible heat build-up 2601, is about twelve inches thick or just under 38 R-value 2583, Recommend 6 mil thick plastic be spread over area missing 2577, light did not work 2571, wiring is exposed, not inside sheathing 2569, has an obstruction inside 2568, would not operate. Non functional 2552, Wiring for fan 2535, is cracked and should be replaced 2528, (on Cook top) 2524, Armored sheathing 2490, Dispenser lid for detergent 2433, cracked at glass pane 2429, missing glazing (enough to loosen glass pane from frame) 2394, is loose, not fastened securely 2381, at various areas where doors don't close completely 2330, is deteriorated or weak along threshold of shower 2315, (Some framing will need repair or reinforcement) 2274, are loose and was not installed properly 2241, needs re-grout and seal 2223, 47 2199, 69 2188, 58 2179, degrees on one unit and on the other one read 2163, Platform for compressor (S) 2159, Air handler 2149, Washable filter 2125, Baseboard register 2104, over 2097, is not insulated and condensation may occur 2085, needs its own outlet. Currently uses an extension cord 2081, in areas 2071, right of stairs 2045, is flaking (Spalding effect) 2033, left of water heater 2011, Electric baseboard 2005, has loose or damaged covers 1999, It could be out of fuel, or needs servicing etc 1993, is leaking at pressure relief valve 1992, but dangerous (flames roll-out at start up) 1982, This does not effect the function of air handler (F.Y.I) 1977, Sight door/opening to firebox 1849, is PVC material (not allowed for hot water). Material must be Copper, Galvanized, CPVC, PEX or Poly 1839, is supported 18 inches from floor, but on a weak platform 1826, bottom heating element and threads may be damaged 1825, top heating element and threads may be damaged 1818, No apparent problems were found 1796, white 1766, has a S-trap, and should be changed to a P-trap and "Auto-vent" 1755, and needs correcting 1743, Shower drain 1732, clogged 1731, Drain valve on pressure tank 1705, Green deposits on copper piping 1683, Hot supply valve 1653, and needs adjustment 1652, does not work properly 1643, drips when off 1630, at utility sink 1558, is leaking, and needs repair 1552, Diverter valve 1532, and needs repair or replace 1519, is loose at floor 1458, is using an extension cord as permanent wiring, and needs to be properly wired or removed 1446, Motor is noisy 1426, in Washer Dryer closet 1425, in Main Bath 1420, in family room 1355, "Three Prong outlet is 1351, also, 1343, inadequate. Recommend adding another duplex outlet to avoid using extension cords 1341, not working 1319, Pressure tank for well 1312, Dryer (clothes dryer connections) 1286, Recommend correct as necessary 1285, Recommend licensed electrician correct 1269, need placing in boxes with coverplates 1244, door is damaged 1227, circuit breaker in main panel is 1187, 50amp 1171, Main breaker is missing, 1167, Improper size/gauge wiring, 1159, Conduit missing, 1118, (right side of home facing rear) 1114, Existing sump pump 1085, and a sump pump is in place 1074, Foundation vents 1046, Old 1034, Aged and deteriorated areas 1024, Concrete piers 1021, Support posts 1011, missing rock and mortar 1002, does not sit on a proper concrete footing 988, failed to support new joists at each end 946, Typical 898, above Kitchen 885, Whole house fan 843, Roof covering needs "Repair or Replace" in this area 842, Recommend structural engineer to inspect 828, (above Garage) 805, 2x6 trusses 782, in bedroom right of bath, 778, in Master bedroom, 773, Door at top of attic stairs, 731, in Bedroom 711, in bush 710, at rear of home 689, Driveway 679, is leaning, and 673, has shifted somewhat, but it appears as old settlement. Wall appears stable at present 631, main level 623, shows signs of water intrusion at door. Depending upon the amount and frequency of water intrusion, corrective measures such as a "Trench drain and grate" may be needed to divert water run off 618, shows moisture absorption on composite type panels 572, Rear entry door 569, Side entry door 563, is not installed (did not inspect for proper operation) 467, Steps 441, Beaded board ceiling 417, are deteriorated 388, Brick wall (s) 366, Cement floor 363, Patio 352, Porch 333, has deteriorated at end cuts 317, and needs replacing 304, is missing, 303, is loose at frame, 290, Rock 279, deteriorated in various areas, and needs replacing 240, front 233, is loose at connector (where gutter sections join each other) 222, Also a four inch boot is needed (two vent pipes) 212, at top of chimney 210, mortar 208, has 206, Rock chimney 157, Skylights 147, shows repair signs suggesting a leak does or did exist 139, on front of home 127, five 105, side addition 97, 1-2 89, Snow or ice 77, Newer roof (less than 3 years old), 74, Roof covering 61, plumbing vent pipe(s) 46, Area still remains strong. Not cost effective to replace 25, bowed 18, upper roof 16, right corner 10, flat roof 2782, is too close to woodstove to be considered safe. Recommend contacting the local Fire Department on clearance requirements 2761, is "stuck," and doesn't operate properly 2715, does not have a proper vent kit 2647, Snake skin (s) 2635, repair screen where missing 2624, not wide enough to reach each side of joist (due to joist spacing) 2612, is about nine inches thick or just under 33 R-Value 2609, is about six inches thick or just under 22 R Value 2606, is more than 16 inches thick or "Plenty!" (R-Value 50+) 2603, is about 14 inches thick or just at 44 R-Value 2596, is about seven inches thick or just under 22 R-value 2578, needs cleaning or is stained in areas 2575, digital timer is illegible or not working as intended 2567, needs rubber strainer/guard replaced 2564, wiring is improper. Recommend licensed electrician to correct 2507, Front left burner 2454, missing knob hardware 2451, all windows 2440, is not considered a functional window 2414, One window 2413, needs grout along sidesplash 2405, Island 2393, at sink 2382, under sink 2371, rubs other drawer (s) 2354, Cabinet door (s) 2337, Metal nosing 2335, Tile at shower pan 2324, is stained along bathtub indicating caulking has failed 2318, Wood covering 2249, Composition board 2238, reveals mismatch in paint touch up 2229, is damaged, and needs repair 2224, 48 2189, 59 2173, that the unit is 2143, is wrong size and does not fit properly 2136, Return air grill 2090, is spliced and should be replaced 2080, broken 2079, needs repair where missing 2078, will need to be re-set in mortar where loose 2041, (seen from FP, looking up liner) 2029, Hall bath 2022, (would not operate) 2002, I am unable to determine life remaining until replacement of furnace 1995, is leaking at flush/drain valve 1961, at sight door 1949, Hand check performed on suction line at Air Handler 1930, supply line is kinked and may rupture 1928, is leaking at overflow 1917, Propane tank 1912, at outside 1845, Gas 1842, is disconnected at vent pipe and is dangerous 1838, sits on floor and must be installed on an 18" high approved platform 1830, thermal expansion tank 1810, was tested with an amperage meter which indicates top element or thermostat needs replacing 1793, yellow 1783, at lower level 1778, Basket strainer 1772, is PVC material. PVC is not allowed as interior supply lines 1736, is double trapped 1696, sink 1693, Recommend a licensed plumber troubleshoot further to determine cause or remedy 1692, fair 1673, is missing a proper P-trap 1672, is a S-trap and should be changed to a P-trap with a vent 1667, Stop-valve linkage 1664, Upstairs Bath sink 1636, loose, and will not tighten 1606, has poor pressure or volume at faucets 1596, corroded 1588, Main water shut-off 1586, pressure or volume is weak 1584, is missing decorative cover or cap 1543, bath 1524, . Repair may involve resetting the toilet on a new wax seal 1521, leaks at supply connection 1512, is rusted through at strainer connection. Repairs may involve replacing sink 1499, Tub enclosure doors 1496, Fiberglass Tub 1482, (Facing rear) 1479, at left side of home 1473, Pool area 1412, is missing a part 1389, is missing "cover-plate" 1338, broken or damaged 1300, Damaged receptacle 1295, incomplete 1268, need coverplates 1235, Furnace room 1218, 15 amp 1175, Romex connectors missing, 1164, Doubled wiring at circuit(s), 1136, 10% 1101, Recommend further investigation by a licensed contractor or water infiltration specialist 1093, support post(s) 1077, Foundation vent flap(s) 1063, (broken glass) 1040, Repairs are optional. 1038, Recommend a structural engineer evaluate. 1025, Steel Lally column 984, floor joist(s) 973, New floor joists should span from wall to girder and be independent of the joist it replaces 932, multiple 921, Repairs are needed. Recommend a structural engineer evaluate 920, Repairs are needed. Recommend a skilled masonry contractor perform the work 908, brick and mortar are loose or missing 895, above Guest bedroom 850, at several areas indicating roof covering has failed and needs replacing 847, Refer back to page one notes on chimney flashing 794, has pickets spaced more than 4" inches apart 753, (above stairs) 742, Formal living room 737, in Master bedroom 732, in Guest bedroom 705, above garage door 697, is to close to house and limbs are in contact with home 688, Brick retaining wall 660, Cobblestone drive 650, needs a sealer applied (prep and seal) 646, Recommend a trench and drain be installed 587, is missing safety chain 544, weathered and needs prep and paint (exterior) 477, Brick column (s) 470, does not directly support deck. Recommend 6x6 supports "notched" to support deck properly 451, deteriorated, and needs replacement 370, Fiberglass floor 360, cracked, and is failing. Recommend repair 349, upper level balcony 345, Plywood floor sheathing 342, Wood floor 328, deteriorated, and needs repair or replace 319, did not access 305, was not found, 258, all downspout locations 241, rear 231, leaks at seam (s) 221, Also a three inch boot is needed (two vent pipes) 217, where end cap of gutter terminates at chimney 175, was not inspected for function or operation of movable window or flap 154, Four 142, right side of home 141, left side of home 135, gable vent 103, half of roof (rear side) 84, However the roof sheathing is weak or deteriorated, and needs repair 73, Unable to determine if this area will leak 72, Roof covering will need replacing before 5 years 66, This area will need periodical maintenance 65, (near chimney) 55, has been repaired 48, Appears to be due to the fact that "Plywood clips" were not used (seen from attic space) 29, deteriorated 17, lower roof 2758, is rusted tight or "seized" (non-operational). Needs repair or replace 2747, are cracked 2744, is old, and does not open and close easily 2714, was routed through "Ash dump" and needs correcting 2701, is using an improper cord for permanent wiring 2698, is disassembled at control box 2692, is defective (fan blade no longer turns easily). Motor and possibly unit, will most likely need to be replaced 2682, Gas/LP Dryer is not allowed to use a lint trap kit on vent pipe 2667, is missing vent cover outside 2650, Squirrel nest 2597, is about eight inches thick or just over 25 R-Value 2593, installed with "Paper or Kraft" face up. Paper side should always face the "Heated Space" or condensation could occur 2588, Rock Wool (loose-fill) insulation 2551, Wall mounted fan 2536, is missing support clips 2512, Bake burner 2511, Broiler burner 2501, Left rear coil element 2495, should be straight wired, but uses a plug instead 2471, does not close properly 2447, three windows 2444, Also, 2441, will not operate properly and may involve repair to linkage of crank handles 2434, needs repair (top sash slides down when bottom sash is raised) 2427, missing sash cords 2424, is damaged at handle or lock hardware 2412, needs knob repaired or replaced 2409, needs caulking along backsplash 2408, (under sink at bottom shelf) from a previous leak 2397, needs caulking with silicone along backsplash 2388, is swollen and beginning to blister 2373, rubs against dishwasher 2369, is peeling in areas 2365, Cabinet shelving 2364, Cabinet baseboard 2356, Drawer face 2350, Support post under steps 2314, Floor covering will need replacing 2311, sags some and is weak. Needs support from underneath 2298, Suspended frame 2289, Moisture meter was used and did not indicate an active leak 2281, Towel ring 2247, Wallpaper 2234, is deteriorated and needs repair 2231, has several hairline cracks (cosmetic), but should be repaired 2227, reveals tape and nail bed areas (cosmetic) 2225, 49 2157, appear damaged and may no longer work properly 2152, Filter 2082, needs re-surfacing with concrete 2072, apartment 2067, 1st bedroom 2064, (downstairs) 2038, is cracked and is not considered safe 2037, was only partially visible. The area that was visible appeared good. For a detailed inspection, I recommend a certified chimney sweep inspect 2009, Recommend a licensed electrician perform repairs that involve wiring 1981, Recommend service or repair as needed 1966, is unusually loud or noisy 1946, Service light indicator on thermostat 1893, indicates possible leak 1884, at drain valve 1856, gas-fired boiler 1850, fails to extend downward to within six inches of floor 1843, Pilot for 1828, bottom or could only be surface rust. Recommend a plumber inspect further 1821, T&P valve which may indicate the need for a thermal expansion tank 1808, was not on during inspection. We did not inspect for proper operation or leaks 1802, is concealed behind a wall. We did not inspect condition of unit 1779, Dishwasher drain line 1726, old galvanized piping that is corroded inside 1724, the plumbing supply configuration and diameter 1677, drains into adjacent sink and does not use intended drain line 1665, Main Bath sink 1659, Guest Bath sink 1616, is broken 1612, leaks at connection 1603, Cold supply line 1599, improperly repaired 1595, Stand for concrete sink 1580, is not working properly, and needs repair or replace 1547, Control lever 1536, is reversed (hot is cold, cold is hot) 1510, does not work properly, needs repair or adjustment 1491, Toilet tank Lid 1481, (Facing front) 1461, on a GFCI breaker at panel, but defective, won't trip when tested 1453, is a "two-prong" receptacle, and should be upgraded to a "three-prong" GFCI outlet with exterior cover 1447, Motor is old or weak 1435, cover is cracked or damaged 1431, needs repair (try bulb first) 1429, does not work 1415, has a loose cover 1407, chain is missing 1393, has exposed wiring 1382, Wall switch 1350, is defective (grounded, but wont trip with test-plug) 1344, outdated and should be upgraded to three-prong GFCI (Ground Fault Circuit Interrupt) 1337, loose in wall and needs repair 1303, air handler, 1301, Receptacle cover is missing exposing electrical contacts (hazard) 1299, Loose receptacle 1293, Conduit 1273, in attic space 1272, overhead 1263, box 1261, junction 1243, fuses are not clearly labeled 1234, meterbase outside 1226, "Double pole" 1213, wire is no longer attached to plumbing 1202, There is an additional charge for a separate trip to return and inspect electrical panel 1188, 70amp 1176, Romex sheathing cut back too far, 1149, Service conductor is loose against home, 1142, 75% 1137, 20% 1135, Approximately 1133, A portion 1120, door locked (could not access) 1069, blocked by insulation 1067, doesn't work properly 1036, No repairs needed at this time. 1016, A proper support is needed where girder is cut 1005, deteriorated at the bottom 989, is not supported properly 982, At least 981, The majority of floor joists 960, living room 950, from wood eating insects 947, Vertical 931, horizontal 928, crack 918, in finished basement 914, in crawl space 912, not visible 896, above Hallway 870, splice boxes 863, Discarded items 861, Personal items still 844, Recommend monitor after heavy rain and repair if needed 806, Post and Beam 772, Door at entry to attic stairs, 769, needs weather-stripping or insulate 743, in Living room 739, in Utility room 721, has a warped panel lid, and no longer fits tight. Needs replacing 693, louver blades are damaged 662, Concrete walkway 656, needs gravel 645, Existing floor drain is clogged or inadequate. Recommend a trench and drain 640, tape at joints is missing or loose 602, (middle door), 589, reveals day light when latched, needs adjustment 586, is missing closure 580, needs rubber on threshold replaced 576, needs doorstop replaced 562, are single pane (FYI) 546, needs caulking along top of trim (exterior) 517, Guest bedroom 447, (at bottom) 415, is weak and is failing 408, (on both sides) 403, loose and needs tighten or repair 397, damaged, and needs repair to match existing 384, Iron railings 376, Concrete stoop 361, old and deteriorated. Recommend repair 334, has swollen, and needs repair 302, is loose at door hardware, 297, is delaminated, 292, pier supports 280, missing, and needs repair or complete work 269, Metal fascia wrap 248, front right corner of home 201, Asbestos slate siding 191, Brick chimney 161, hall bathroom 151, is cracked 145, (facing rear) 109, is failing at seams or nail heads and needs repair or re-coat 98, 2-3 88, Recommend increase ventilation at next roof replacement 81, random caulking. Unable to determine if leak has been corrected 2776, Slate 2773, is rusting 2769, Damper frame 2745, do not stay in track and could fall out when used 2736, does not have a "Shut off" valve above floor (not easily accessible). 2699, did work, but 2688, Dryer receptacle 2676, is soft copper (ran through floor). Only "hard-piping" is allowed to run through floor or walls when using natural gas. Recommend correcting 2672, Light mode on exhaust fan 2668, has a damaged vent cover outside 2653, Eaves and Fascia 2586, Fiberglass (Rolls) insulation 2565, wiring remains under sink, and should be placed in a box with a cover and secured to wall 2553, Light socket for fan 2548, noisy or vibrates 2545, is non functional 2538, has a splice that needs placing in a box with cover 2517, Oven glass 2509, Right rear burner 2435, does not lock properly 2368, needs adjustment or repair 2353, third story 2345, foyer 2286, reveals a water stain indicating a leak did or still exists 2284, Bath accessories (towel bar, tissue, toothbrush holder etc.) 2165, is clogged or needs cleaning 2158, is undermined and needs filling in with gravel and concrete 2133, in Half 1/2 Bath 2120, Boiler piping 2110, Duct tape 2096, needs support straps 2052, "Insert" 2048, Vented firelogs 2007, on wall heater 1991, but carbon deposits on burners or jets indicate the need to service 1983, briefly comes on, but will not fire 1979, Circulation pump 1959, around collar 1956, Oil-fired boiler 1908, under Range 1892, Discontinued oil barrel 1889, Oil line 1886, Recommend repair as needed 1882, at oil barrel 1880, at furnace motor 1872, is black or dark plastic in material and may be defective. Manufacturer has ordered a recall on "core-vent" and "ultra-vent." 1868, is missing a section allowing carbon monoxide into area 1857, wood burning furnace 1837, would not light 1824, hot supply shut-off 1820, Recommend a licensed plumber inspect further 1780, Sink basket 1769, is kinked and needs repair 1754, (under sink) 1753, runs continuous and needs repair 1745, Main soil pipe 1715, Water Softener unit 1663, Downstairs Bath sink 1627, under bedroom 1615, (taped) 1591, Waste-water pump 1577, leaks at connection (under sink) 1574, Both Supply lines 1546, Cold control 1544, Both control knobs 1542, partially clogged 1535, is not long enough and water pours on overflow cover and could leak 1534, from toy cover 1465, Recommend a licensed electrician to correct 1464, did not trip when tested (defective) 1450, is missing louver slats 1434, uses a light socket adapter and should have it's own outlet 1417, was not inspected (could not locate switch)? 1385, (for light fixture) 1380, "Three-prong" outlet is 1375, Half 1/2 Bath 1368, on left 1354, "Two-prong" outlet's are 1352, GFCI (Ground Fault Circuit Interrupt) 1334, is taped (splice) 1330, has an open splice 1322, in utility room 1315, pond 1306, fluorescent light fixtures 1287, Exposed wiring 1249, is missing cover 1237, attic 1217, wire is no longer attached to ground rod 1211, wire is loosely connected 1204, downstairs 1197, personal items that could not easily be moved 1189, 80amp 1157, Breaker(s) are taped, 1155, Breaker(s) are different brands, 1152, (at original panel location), 1138, 30% 1130, Bedroom 1104, (left side of home facing front) 1089, floor 1084, at pier supports 1076, Screen for foundation vent(s) 1070, needs weatherstripping 1052, furnace 1033, Spalding or flaking occurring 1027, Steel jackpost(s) 1000, is cut or damaged by tradesman 986, contains under-sized wood members 974, Replacement joist(s) that does not span from wall to girder should be supported properly where it stops short 972, Repairs are needed. Recommend a licensed contractor perform the work 967, Water heater 966, addition 951, from a leak 943, Stair-step 925, Previous repair made to wall appears adequate 909, block and mortar are missing 840, The structure remains strong and safe 810, around water heater vent piping 802, 2x10 rafters 785, has a split or damaged stair tread 741, in Bedroom (at end of hall) 734, (right of hall bath) 729, at coat closet 728, does not allow reasonable access and should be corrected or relocated 695, is leaning toward home and may need trimming or removing 685, Rock wall 678, does not appear to drain ground water adequately. Needs to be corrected 677, was built improperly or appears inadequate to support weight over an extended period 665, Stone walkway 611, is using an extension cord as permanent wiring, and should have it's own outlet (GFCI recommended) 608, needs prep and paint 582, Screen door 534, needs strike and latch adjustment to shut tight 533, rubs floor when opened. Door needs to be trimmed at bottom by a skilled craftsman 521, Lower level 516, Master bedroom 510, Sliding screen for glass door unit 504, Flashing (used at top of window to prevent water intrusion) 497, Left sidelight on main entry door 481, Lally columns (s) 474, Floor Joist (s) 463, Recommend licensed General contractor to correct 455, needs "joist hangers" or "ledger strips" to properly support joists at end cuts 438, Rock exterior 434, Brick exterior 430, shows were semi-gloss paint was mistakenly used to touch-up flat 418, are weathered at post base (lightly deteriorated) and needs repair 413, is rough and should be sanded to avoid splinters 400, rusted, and needs prep and paint at cleat or anchor to preserve rails 386, Top plates of guardrail, and some decking 381, Wood guardrails 364, Covered patio 357, beginning to deteriorate, and needs a sealer applied 348, Covered porch 327, painted 321, and recommend repair as needed 287, all areas of exterior 264, Soffit panels 262, Recommend repair or replace as necessary 255, dented 239, incorrect slope toward downspout, 207, Metal Chimney chase 136, gable vents 126, four 124, two 117, Area around base of chimney shows caulking or repair signs 115, Chimney base has been tarred instead of flashed, and is failing. Recommend proper repair 113, Chimney has step flashing but no cap flashing, and needs proper repair 95, Wooden drip edge 92, excessive "moss" growth. 50, Next roof, I recommend a complete tear-off and install new 36, chimney 7, left side (facing front) 2786, Mantle support 2772, arm 2764, Damper arm and linkage 2738, is crimped or damaged and should be repaired 2735, is piped improperly at fireplace. Soft copper piping is not allowed to pass through walls or floors if used for "Natural Gas" 2729, is rusted and needs surfaces repaired 2728, is rusted at flue pipe 2709, (out of fuel) 2687, Dryer wiring 2683, is plastic vinyl and is not allowed when dryer is powered by gas/propane. Recommend changing to metal flex 2642, Active bee nest 2636, replace glass 2623, installed wrong side up 2615, is about twelve inches thick or just under 44 R-Value 2598, is about nine inches thick or just over 28 R-Value 2581, is deteriorated in areas 2574, door handle is broken or needs repair 2566, is rusted inside at blades 2508, Left rear burner 2492, Dispenser lid for rinse 2488, heat coils 2480, did not perform a loop to create a trap under sink. Recommend correcting to avoid a possible back up of sewer water into dishwasher 2439, needs repair at jamb spring 2430, missing one sash cord, but is able to stay in position when raised 2422, missing lock hardware 2400, missing end cap 2387, is swollen at diagonal seam 2384, at island 2361, Wall cabinetry 2309, was not installed according to standard workmanlike practices 2302, Wood boards 2283, Towel hook 2275, are loose and needs repair 2267, Tile surround at shower 2248, Paneling 2246, Plaster 2244, shows evidence of wood eating insects 2240, is damaged or deteriorated. Framing in wall may need repair as well (not visible) 2239, reveals damage from pet 2232, is peeling in areas and needs prep and paint 2230, is loose, and needs repair 2167, Drain valve 2147, and needs cleaning 2138, in wall 2103, at main plenum 2055, Warm Morning 2051, (Propane) 2049, Non-vented firelogs 2008, in Dining Room 1997, Collar gasket may be leaking 1964, is dented 1951, Excessive ice build-up 1942, Compressor fan 1940, Recommend service or repair unit using a licensed HVAC contractor 1923, Thermostat is damaged 1897, was installed improperly using soft copper through floor instead of hard piping 1881, at oil filter 1864, is damaged and can allow carbon monoxide into area 1854, gas furnace 1835, needs servicing (charred deposits) 1834, is missing flame shield at bottom 1809, was not on upon arrival for inspection. We did turn on to check for proper operation. We could not inspect for leaks that only develop under pressure 1770, should be mounted and form a "Loop" under sink to prevent a possible backflow of contaminants 1768, is kinked at garbage disposal 1758, (right sink) 1756, and may eventually clog 1746, Main waste line 1733, drains slow 1702, White deposits on faucets and showerhead 1679, appears to drain outside or bypasses main soil pipe? Also known as "Gray water," this method is no longer accepted and should tie into septic or sewer. Recommend a septic inspection to determine if tank is capable to handle water volume from washing machine drain 1678, drains into sink (does not have it's own drain line) 1669, Stop-valve strainer 1639, turned off (winterized). We did not inspect this faucet or plumbing line 1605, Both supply lines 1600, knob 1571, Cut off valve for 1567, Cold control on faucet 1565, Control knob on faucet 1563, Faucet 1497, Bathtub 1490, Toilet tank 1466, clogged with dirt or insect debris 1430, is old and rusted 1405, may not be mounted properly 1395, purpose is unknown (could not identify) 1357, outlets are 1329, is improper size 1321, Range top 1320, Water system flush 1316, range exhaust fan 1277, in unfinished room 1259, splice box 1253, is needed 1250, is missing battery 1233, Washer & Dryer room 1199, amateur trim work concealing the screws 1181, Defective GFCI breaker 1178, Sub panel feed is undersized, 1174, Panel box is loosely attached, 1160, Conduit connectors missing, 1147, Service conductors clearance from ground is improper, 1139, 40% 1096, Recommend a sump pump be installed or other methods to correct intrusion 1095, ground 1086, from water stains on 1057, water heater 1037, Recommend a concrete sealer be applied over surface for protection. 1012, are under-cut in areas 997, The floor does appear weak when walked upon 990, is old and weak 970, (rear of home) 955, have mold spores which indicates the need for ventilation 938, This crack does not appear significant to require repairs at this time 926, I recommend that you obtain a letter from the structural engineer who designed repair 886, Light fixture 882, Damaged or exposed wiring 880, Improper splice connection of Romex and "Knob and Tubing" 852, Water signs on "common board" roofing 845, Leak appears to be corrected 832, Recommend caulk boots or replace if necessary (On Roof) 821, (above Master bath) 788, at or near bottom of stairs 775, Attic access door (in closet) 760, needs steel screws installed at hinge-mounts per manufacturers recommendations 747, in private bath 744, in Kitchen 722, has loose trim and needs tightened 687, Decorative wall 672, shows signs of erosion and a possible drainage problem 641, incomplete or lack of a fire wall 625, (both doors) 581, Storm door 554, has cracked glass 542, cloudy, and needs replacing 526, Exercise room 525, Garage 485, Outer bands 479, Stone column (s) 478, Rock column (s) 475, Floor joist (s) and outer band 419, at carport 410, near bottom of stairs 407, (on one side) 405, needs proper picket spacing (4 inch max between pickets recommended) 395, Block wall 392, Support column (s) 351, upper level Deck 350, Deck 313, Access door to crawl 310, has a pet access door installed 261, not primed and painted 238, leaves or debris (clogged), 227, 4 inch 216, at horizontal top trim 215, above roofline 185, rusting. Needs prep and paint 163, master bathroom 159, den 148, cloudy, (lost seal) 137, soffit vent screen 125, three 99, 3-4 94, Wooden crown mold 82, visible coating of tar or roof cement 80, recent visible caulking. Unable to determine for certain that leak has been corrected 71, The color difference is only cosmetic, and does not effect the integrity of roof covering 49, This causes a lot of weight on roof. Recommend tear off coverings and replace as necessary 2755, Access panel 2741, is damaged at connections and risks possible leak 2710, (pilot would not ignite) 2655, through hole in window where glass is missing or broken 2620, is loose/fallen 2611, is about eight inches thick or just over 29 R-Value 2560, control indicator is illegible 2557, Microwave 2554, Light bulb for fan 2534, needs cleaning or repair (would not ignite properly) 2516, Oven door 2510, Grill burner 2503, Bay element 2483, Dishwasher rack 2461, Closet door 2419, Six windows 2398, does not butt evenly against wall (Wall out of square) 2383, at some cabinet doors 2367, Revolving base 2363, Cabinet trim 2348, Step Tread on steps 2323, Lower Level 2316, needs shoemold 2303, Pine boards 2291, is peeling as a result from water leak above 2266, Tile surround at bathtub 2261, needs silicone caulking around control knob coverplate 2260, has been caulked instead of applying grout where obvious 2226, is missing (no cool-air source) 2166, needs an extension to carry water away from home 2140, Diffuser in ceiling 2134, in Hall Bath 2108, ductpipe 2091, Ventilator fan 2087, Needs a 3 prong outlet (GFCI Recommended) 2023, oil fired boiler 1976, Service door 1968, is missing a safety switch that cuts off unit when door is removed 1875, needs a 6 inch clearance from combustibles 1832, Recommend a licensed plumber inspect further and repair as necessary 1786, at pressure tank 1776, P-trap on wasteline 1773, is PVC material. PVC is not allowed to supply hot water 1717, System flush unit 1700, main bath 1670, is loose and does not fit properly 1662, Shared Bath sink 1626, under living room 1608, leaks at aerator 1597, cracked 1589, Utility sink 1561, was repaired improperly 1514, Half Bath 1476, Exterior duplex outlet 1439, Lower level entry door 1411, glass is cracked or broken 1335, has a loose romex connector 1333, was spliced outside of panel 1267, needs a coverplate 1224, 90 amp 1215, wire is attached to hot supply and should be placed on cold supply (within five feet of supply entry) 1177, Sub panel by-passes main breaker, 1170, Main breaker over-sized, 1143, deck is lower than 10 feet 1140, 50% 1123, limited or no space between joists and ground 1116, Wiring for sump pump 1105, (right side of home facing front) 1102, (along front of home) 1099, Unable to determine if existing sump pump removes all water intrusion 1081, on plastic vapor barrier 1072, all vent locations 1068, doesn't function (fixed panes) 1062, (cracked glass) 1056, plumbing fixtures 1054, junk 1028, and some joists 1014, Recommend a licensed contractor inspect and repair as necessary 941, The wall(s) may need reinforcement. I recommend a structural engineer evaluate 936, No repairs needed or foreseen at this time 934, typical 929, cracks 916, Recommend a licensed contractor inspect further and perform appropriate repair 915, along 913, at several areas 904, undercut 897, above Living room 888, Electrical wiring needs to be placed inside conduit 854, Container(s) placed in attic 833, Recommend caulk nail heads and seams of ridge vent (On Roof) 824, (above Guest bedroom) 781, in bedroom left of bath, 780, in upper room, 768, needs adjustment to latch tight 718, does not fit opening properly 717, missing baffles to prevent insulation from falling down when lid is raised 684, Stone retaining wall 667, Rock steps 655, needs repair work at erosion areas and gravel or Road Bond placed 642, mortar where missing, and seal 601, "right" door (from outside), 575, Foyer 571, Transom above main entry door 566, difficult to operate 543, shows areas of peeling paint 538, does not fit opening properly (out of square) 537, does not shut properly 520, Great room 509, Sliding screen 505, Vinyl shutters 466, Stairs 459, rusting and needs preparation and paint to preserve integrity 457, leans or not level and needs better support at ground (cap block or slab) 445, Screen panels 444, Soffit panels on ceiling 433, Siding on wall 421, missing in areas, and needs repair 401, are rusted and deteriorated at bottom cleat 377, Pickets 374, Stone floor 324, broken, and needs repair 309, needs hardware alignment to latch easily 260, begining to deteriorate 254, missing part (S) 250, left corner (facing rear) 226, 3 inch 223, Also a two inch and four inch boot is needed 205, Old asphalt style siding 177, above roof line 133, Two 107, left side of chimney 104, rear addition 37, Sun Room 35, side porch 24, (Asphalt shingles on top of metal) 2775, has been repaired with materials other than exact replacement parts 2760, is missing bolt or fasteners, and needs repair 2749, are difficult to operate 2737, Ash dump missing frame/lid 2723, is missing a continuous cloth gasket around door 2716, is loosely connected at vent hood and needs correcting 2661, has a burn mark on light cover (over watt bulb used) 2638, seal off openings 2582, Recommend 6 mil thick plastic be spread over 80% of crawlspace 2572, wiring is has a loose romex connector 2561, does not cycle properly 2520, Oven cord 2515, Control knobs 2494, is improperly connected to wall outlet 2465, Double Doors 2463, Bifold door 2410, has a hole in wall area from plumbing repairs 2401, has loose tile or grout. Needs repair and seal 2366, frame 2349, Step treads on steps 2347, weak and needs better support 2325, is stained around toilet indicating a leak did or still exists 2322, Subfloor and framing 2319, Carpet 2310, is weak and needs reinforcement from underneath 2306, is curling around edges and needs securing with adhesive and, or shoemold 2290, has multiple cracks. Ceiling needs repair or replace 2279, Tissue holder 2277, Upstairs 2263, needs grout or silicone around perimeter where wall tile rests on tub 2235, is missing in areas 2210, 80 2171, both Air conditioners 2162, Cooling fins on compressor 2148, Disposable filter 2146, does not seal off air properly 2145, is wet, indicating the need to service unit 2144, is collapsed and needs replacing 2141, did not operate or is defective 2137, in floor 2111, Main plenum 2065, (on main level) 2039, is damaged and needs repair or replace 2026, There will be a return trip charge to re-inspect 1973, Blower unit on air handler 1937, is on and did not turn off when tested 1936, overflows (not working properly) 1935, did not operate when tested 1933, at outside unit 1911, in bedroom 1902, for gas logs 1874, is rusted indicating need for a rain cap on chimney 1866, is loose and needs a support strap(s) 1860, needs mastic sealed around pipe where it enters chimney 1847, Power vent for 1829, bottom due to rust signs, however insulation around liner is dry 1814, capacity may not be enough for large jet powered tub 1788, on front wall 1762, is leaking 1761, is leaking at cut-off valve 1757, bath sink 1750, is slow or clogged 1719, Our company did not inspect the unit for performance or condition 1695, shower 1690, weak 1676, has an old style trap that should be upgraded to a P-Trap with a vent 1658, Half Bath sink 1637, loose, and needs securing to wall 1623, under kitchen 1573, Cold Supply Line 1559, is missing knob, and needs repair 1553, Chrome finish on faucets 1541, drips 1540, loose in wall 1520, leaks at floor 1518, Upstairs Bath 1500, Grab bar on bathtub 1478, GFCI outlet (Ground Fault Circuit Interrupt) 1472, Storage building 1457, has a damaged cover, and needs repair or replace 1423, in Sunroom 1416, is mounted less than 7 feet and could be too low to stand under 1406, has loose wires exposed 1403, does not have a proper mounting box 1400, does work, but 1356, "Three Prong outlet's are 1342, old and contacts are loose and no longer holds plug securely. Needs replacing 1340, incorrect "reverse polarity" 1327, in Dining room 1304, automatic door opener 1297, missing connector(s) 1296, hanging with loose end (no longer used) 1248, temporary pole 1246, Recommend a licensed electrician repair as necessary 1242, circuits are not clearly labeled 1231, circuit breakers in both main panel and sub panel are 1209, clamp is rusted and deteriorated 1179, Sub panel feed missing ground, 1172, Meterbase is undersized, 1141, 60% 1121, someone sleeping 1111, has an exposed wiring splice 1098, Unable to determine the extent of intrusion or how often it occurs 1055, mattresses 1026, Steel Lally columns 1009, missing brick and mortar 999, split or cracked 963, guest bath 957, is adequate 956, were not visible or accessible 953, are cut or damaged by Tradesman 901, above utility room 884, Attic fan 855, Discovered what appears to be an "old" water sign 838, Recommend licensed contractor correct 817, around gable vent 804, 2x4 trusses 800, 2x6 rafters 765, missing a step and could be a tripping hazard 763, is weak and not stable 750, (above stairs to basement) 749, (at lower level) 736, (left of stairs) 730, in Hallway 714, in attic 707, under deck 668, Gravel drive 659, Asphalt drive 657, has settlement cracks 621, does not close tight at opening 612, (both openers) 603, is manually operated 574, Area room 532, rubs at top when closing 531, rubs at jamb when closing 529, reveals daylight when latched at areas missing weather-stripping 519, Den 514, Kitchen 506, Sliding glass doors 491, on property 489, missing. Recommend install rail with maximum space between pickets to be four inches (where platform exceeds 30 inches from ground) 472, Girder that supports joists 462, not considered stable or safe to support occupant 432, is torn or damaged 414, is weak, and needs reinforcement or changing to a more stronger design 398, are spaced too far apart for safety. Recommend maximum space between pickets to be four inches 394, Wrought iron support (S) 380, Wrought iron railings 367, Tile floor 354, has loose stones and mortar (small area), and needs repair 325, cracked, and needs replacing or caulk with clear silicone 306, deteriorated at bottom frame, 293, Block 284, "All" of exterior 275, loose and deteriorated. Needs repair or replace as necessary 274, loose, and needs mortar and repair as necessary 256, needs reconnecting to existing drainline 247, front (left of main entry) 244, collapsed inside gutter 236, virtually all areas where gutters are installed 225, 2 inch 200, Wood shakes 186, missing. Recommend installing one 184, loose. Needs to be secured 178, Paint 167, dining room 162, guest bathroom 153, (Glass) 134, Three 129, main roof 120, Recommend "Step and Cap flashing" be installed 119, Unable to determine if leak has been corrected 116, Caulking or patched areas of roof cement around base of chimney 100, 4-5 67, Does not appear adequate. It should be properly repaired or replaced 42, Roof sheathing is loose, and it appears that it will lay flat again once nailed and caulked 33, rear of home 31, loose 22, (West side of home) 20, (South side of home) 14, Dormer (along bottom of dormer) 9, garage 2784, Rock mantle 2756, does not function properly due to debris around damper 2748, is warped or bent and does not shut tight 2733, Ash Dump Lid 2727, does not shut completely at door 2695, is non operational 2670, Fan mode 2649, Squirrel damage 2641, Inactive bee nest (Large) 2622, hanging loose 2614, is about eleven inches thick or just over 40 R-Value 2585, Fiberglass (loose-fill) insulation 2584, Insulation 2579, is missing in over half of crawlspace 2558, did not work when operated 2556, Grease filters 2550, Ceiling mounted fan 2544, appears installed too low to burners. Recommend refer to manufacturers minimum distance requirements 2543, is missing romex connector 2542, has an open splice and needs correcting 2539, vents into attic space and should vent to the outside. This would require a vent hood and kit 2525, Fan switch 2522, Oven plug 2518, Light bulb 2491, Dishwasher drain hose 2489, spray prop 2481, did not operate when tested. Recommend an appliance repairman inspect further. 2475, did not complete normal cycle. Recommend appliance repairman to inspect further 2469, is rusted in areas 2457, needs nail heads set, putty, prep and paint or seal 2432, cloudy (lost seal) 2425, missing screen 2420, All windows 2416, Three windows 2407, along backsplash 2343, second story stairs 2327, Subfloor is deteriorated in this area 2317, Vinyl 2307, reveals seam 2304, has some blemishes or small tear 2265, is dented or damaged from door knob 2254, Stone veneer 2253, Rock veneer 2245, Sheetrock 2211, 81 2200, 70 2155, needs extending away from unit to prevent erosion and pad for compressor to become unlevel 2139, in ceiling 2135, Supply Register 2118, is wrapped in possible asbestos 2115, is not insulated 2102, at ceiling register 2092, Blower fan 2083, is loose, and failing 2056, Gas stove 2054, Wood burning fireplace 2050, (Natural Gas) 2034, right of water heater 2010, Safety measures should be performed, or relocate outlets 1947, Foam sleeve on suction line 1945, Emergency heat mode 1934, at air handler inside 1869, is missing draft compensator 1863, shows evidence of poor venting (white deposits, rust on piping) 1853, oil furnace 1801, is old, rusted and at the end of it's life expectancy. No leaks at present 1795, black 1781, underneath in crawlspace 1767, is leaking at connection 1749, at main bath 1716, Sediment filter 1657, Master Bath sink 1656, Hall Bath sink 1633, drips at knob when turned on 1593, Pressure tank for well water 1550, Tub spout 1529, leaks 1503, Medicine cabinet 1501, Side splash on sink countertop 1477, Duplex receptacle 1444, Pull chain 1404, is not mounted properly 1391, is broken (unsafe) 1384, (for ceiling fan) 1372, right of hall bath 1371, left of hall bath 1366, Small Bedroom 1360, Living Room 1313, garbage disposer 1311, washing machine 1305, Boiler 1283, in Washer/Dryer room 1258, bedroom of each rental unit 1257, bottom of stairs 1254, needs relocating at least 4 inches from ceiling/wall junction and no further than 12 inches away 1241, door will not close 1210, wire is improper in size/gauge 1144, ground is lower than 12 feet 1107, is not installed properly 1091, shelving 1050, appliance 1047, Discontinued 1039, Repairs would involve a topcoat and concrete sealer, if desired. 977, Existing vents are closed off and should be opened before determining if additional ventilation is needed 952, are split or cracked 949, from moisture absorption or water intrusion 910, rock and mortar are missing 900, above private bath 893, above Guest bath 879, missing coverplates 876, Two electrical splices 866, Large accumulation of debris 857, Common board roofing 853, Water signs and "wet insulation" 823, (above Master bedroom) 820, around solar tube piping 809, along valley 797, shows previous repairs 793, has loose pickets that need tightened 777, in bedroom right of stairs, 766, missing nut to secure step 715, at right side 702, Hornet bee 696, is close to house and could sway and bump home during adverse weather conditions 669, shows some settlement cracks, but appears stable 666, Brick walkway 654, shows signs of erosion and problem needs to be addressed 628, needs weather stripping replaced at bottom 622, not connected to opener. Appears inoperable 617, missing light cover 616, is deteriorated at panel 595, has a defective closure 584, is missing glass storm pane 570, Entry door 565, reveals daylight at threshold when latched 557, deteriorated at bottom of jamb (s). Needs repair 547, needs excess caulking or glazing removed 522, Basement 518, Sun room 515, Dinning room 513, Transom light above Glass door unit 512, Screen panel for patio doors 458, rusted and deteriorated 427, deteriorated, and needs repair to match existing 362, has settled and rain drains toward foundation of home 359, loose, and missing in areas. Needs skim coat and sealant applied 308, is deteriorated at bottom of side jambs 267, (behind gutter) 253, right side of home (facing front) 194, Metal flue pipe 192, Stucco coating 181, Stucco 166, hall 51, This roof has more layers of roof covering than what is normally allowed 39, both sides (front and back) 21, (East side of home) 13, middle dormer 4, Sun Room, 0, front of home, 2774, is broke 2746, are "smoke stained" and may not clean 2743, is not secured around fireplace opening 2719, Damper 2712, We did not inspect further 2685, is long and vertical which can trap lint at elbow. Recommend periodical cleaning 2673, has an improper splice and needs replacing 2671, Heat mode 2660, is missing light cover 2621, is wet with condensation which indicates the need for ventilation 2616, is about 13 inches thick or 47.6 R-Value 2587, Fiberglass (Batts) insulation 2526, (in Oven) 2467, is loose and needs securing to underside of countertop (using a proper length screw) 2452, Office 2446, two windows 2445, one window 2438, has pulled loose at frame 2396, Recommend caulk seam with silicone 2352, second story 2320, Linoleum 2305, is stained 2299, Beaded boards 2297, Ceiling Tile 2285, reveals a light stain which appears from a water leak. Stain appears old 2242, needs mortar or grout where loose 2212, 82 2201, 71 2190, 60 2156, is full of water and is not working properly 2130, is missing (no heat source) 2129, (not intended for floor) 2123, Control knob for radiator 2068, 3rd bedroom 2030, Upstairs bath 2025, Recommend licensed electrician inspect 2004, are located above electric baseboard and cords could possibly come in contact with heating element 2001, Due to the age and condition, opinions on life expectancy will vary by different HVAC contractors 1922, Thermostat is loose 1907, at dryer 1906, at furnace 1865, has a hole in piping that does not draw (tested with a match) 1846, Propane 1822, hot supply outlet 1792, red 1791, blue 1784, at utility room 1727, brass fittings 1712, Salt pellet container is empty 1701, Odor in water 1694, Because only the hot supply is weak, problem may involve water heater 1688, Decorative frame cover for connection box 1674, is missing an "auto vent" 1661, Lower Level Bath sink 1648, Outside water faucet 1642, leaks at anti-siphon 1628, under storage room 1625, under dishwasher 1620, under hall bath 1530, does not operate 1526, won't flush unless lever is held down briefly 1505, has a hole in surface and needs repair 1498, Shower door 1495, Shower stall 1488, Toilet 1484, GFCI (Ground Fault Circuit Interrupter) outlet 1442, hangs by its own cord and should not 1438, is wired incorrectly (reverse polarity) 1419, in Attic bedroom 1409, is controlled by pull chain only 1369, on right 1359, Hallway 1332, no longer used (discontinued). Needs placing inside a box with a coverplate 1328, is exposed 1266, open splices 1265, open splice 1245, screws are not accessible due to carpentry trim 1240, is missing knockouts (DANGEROUS) 1232, bedroom 1225, 60 amp 1191, circuit breakers 1183, 15amp 1163, Doubled wiring at fuse(s), 1156, Breaker(s) loose, 1126, plastic 1109, uses an extension cord and should have it's own GFCI outlet 1090, carpet 1087, baseboard 1080, from silt stains observed 1049, boards 1035, Shifting occurring 1029, Brick columns 978, No additional repairs are needed at this time 965, master bath 961, dinning room 948, are deteriorated at end-cuts 864, Accumulation of discarded items 858, Wood slats on roof 851, Water signs on plywood 816, around hood of "thermostatically controlled" vent fan 813, around ridge vent 807, around chimney 798, are under-size or span is too far, and a knee wall should be built (in attic) to reinforce roof 795, as a result from a leak 771, Door to Attic 726, missing panel lid 720, has a cracked panel lid, needs replacing 708, on wall 704, Yellow jacket bee 699, Large bee 692, louver blades on cover do not work properly 683, Concrete retaining wall 681, has some loose or deteriorated timbers, and needs repair 664, Landscape walkway 661, Sidewalk 647, Recommend a pit "filled with gravel" in front of below grade entry 634, Two-door garage 615, beginning to delaminate and needs repair 606, does not operate properly and needs repair or adjustment 604, will not reverse when met with resistance 585, is missing screen 556, has been damaged and repair attempts have been made. Workmanship appears less than standard 552, does not travel across track properly, and needs repair or replace 545, delaminated 540, missing steel security screw at each hinge 501, Window frame 483, Wrought iron support (s) 482, Steel braces 473, "Drop Girder" that supports joists 454, are not uniform in "riser height" and are a tripping hazard 406, is damaged and needs repair 378, Guardrails and pickets 365, Sunroom 326, damaged by BB or pellet gun 295, Recommend structural engineer to inspect and design adequate repair 281, Wood trim 268, Rafter tails 266, Fascia board 251, right corner (facing rear) 249, front left corner of home 213, on backside 173, is cracked at glass pane 152, (Plexiglass) 143, both gables 128, six 83, visible coating of tar or roof cement. It appears that leak has been corrected 69, It should be replaced as soon as possible 63, starter strip 58, is nearing the end of it's life cycle 40, Area still remains strong. Not cost effective to replace until next roof 27, sags 26, bulges 3, covered porch, 2767, Damper lid 2763, is warped or no longer seals tight 2732, is full of ashes and needs cleaning 2730, Also, recommend installing a "rain Cap" on chimney 2693, is no longer connected to wiring 2654, Window opening 2630, most of home 2618, is about 15 inches thick or just under 55 R-Value 2610, is about seven inches thick or 25.6 R-Value 2604, is about 15 inches thick or 47 R-Value 2599, is about ten inches thick or just over 31 R-value 2595, is about six inches thick or just under 19 R-Value 2563, wiring is missing romex connector 2533, does not turn properly 2529, (on Range) 2521, Range cord 2477, is coated with mineral deposits. Recommend consulting with a water filtration specialist 2464, Pocket door 2437, has a damaged screen panel 2431, missing sash cords and have been repaired with jamb hardware instead 2411, is missing knob hardware 2402, Laminated countertop 2391, is swollen under edge 2362, Base cabinetry 2357, Drawer track 2342, attic stairs 2287, Due to recent dry weather, I am unable to determine if leak still exists 2282, Toothbrush holder 2280, Soap dish 2257, Wainscot 2213, 83 2202, 72 2191, 61 2180, 50 2177, not cooling properly and a licensed Heat/Air contractor should inspect for cause or problem 2176, the unit for lower level 2151, Disposable filter cartidge 2127, is noisy (tone or hum) 2119, has been disconnected 2109, Plenum 2058, Metal liner 2036, has 1/4 inch or more build-up of creosote and needs cleaning 2019, electric baseboard(s) 2017, Outlets 2000, Recommend further inspection by a licensed heat contractor 1994, is leaking at a valve 1985, but 1967, is worn 1965, will not shut properly 1962, where motor mounts to the heat exchanger 1960, around gasket 1948, Suction line 1943, Condensation line 1941, Recommend further inspection by a licensed HVAC contractor 1931, is not level 1904, at fireplace 1900, Recommend Gas company or professional inspect for leaks 1894, is loose and needs securing 1885, at bottom 1876, is kinked 1797, silver 1764, has improper connections or repairs. Recommend a licensed plumber correct 1759, (left sink) 1747, P-trap 1709, mineral deposits on fixtures remain which may indicate unit is not working properly 1698, tub 1697, toilet 1645, connected to garden hose. We did not remove hose to check for a possible drip 1640, leaks when turned on 1634, missing knob(s) 1632, Pressure tank 1610, Recommend repair or replace by licensed plumber 1601, leaks when on 1576, leaks around mount, and needs repair 1545, Hot control 1523, and needs tightened 1508, is wrong size (Doesn't fit) 1494, Countertop 1455, loose in wall, and needs to be secured properly 1436, hangs by it's own cord and should not 1410, needs repair or replacement 1383, Dimmer switch 1347, damaged (foreign object blocking prong holes) 1325, at master bedroom 1308, outlet 1282, in kitchen 1276, in workshop 1274, in basement 1262, splice 1252, did not work when tested 1223, Main breaker 1222, 50 amp 1212, wire is missing a proper clamp 1193, fuses 1150, (in sub panel), 1131, ceiling 1128, Storage room 1122, Barking Dog(s)inside 1117, Container for Sump Pump 1113, Recommend a licensed electrician perform repairs 1100, Unable to determine if repair is successful 1097, Sloping the ground or trenching may be needed to direct water 1094, and wall has been coated with a waterproofer 1088, wall 1082, and a trench has been dug 1060, stuck or painted shut 1051, boiler 1045, dirt basement 1018, Drop-girder 1001, not visible or accessible 996, The floor does appear solid when walked upon 975, A proper support is needed where joist(s) are cut 964, hall bath 958, was not repaired according to standard practices 935, vertical 875, One electrical splice is missing a coverplate 871, loose wire end 837, shows signs of wood eating insects 829, (above private bath) 796, missing where chimney previously was located 789, at or near middle of stairs 761, missing pull string 756, needs help to close (pull at left hinge when closing) 748, (at upper level) 746, in Master bath 738, in Garage 733, (left of hall bath) 727, missing proper trim mold 706, in ground 698, appears damaged or roots exposed 648, deteriorated in areas and needs repair or replace 620, does not close or seal tight at floor 619, shows a noticeable repair 610, is using a light fixture adapter, and should be changed to a grounded or GFCI three-prong outlet 598, has a damaged handle and needs replacing. 593, is damaged at jamb where closure arm pulled loose 588, does not shut properly, needs adjustment 541, has improperly installed hardware that was not recessed flush with jamb 528, missing weather-stripping 498, Right sidelight on main entry door 490, Guardrail 461, broken, and needs replacement or proper repair 453, spaced too far apart. Recommend adding joists, and/or blocking to reinforce 423, loose, and needs repair to match existing 420, unfinished 404, is missing. Recommend install rail with maximum space between pickets to be four inches where platform exceeds 30 inches from ground 387, Lattice 346, Deck floor 331, warped, and needs repair or replace 299, is damaged, 243, right side 220, Also another two inch boot is needed (two vent pipes) 219, This area can leak if not corrected 218, at bottom piece where it comes in contact with roofline 214, at corner board 176, throughout 174, trim is missing 158, Living room 131, peeling paint 121, Metal flashing did not weave under shingles and is improper 101, Entire roof 76, Old roof covering 75, Flat roof 44, Roof sheathing needs to be replaced in this area. This will involve shingles and flashing 41, Roof sheathing needs to be replaced in this area. This will involve some shingle replacement 19, (North side of home) 11, left dormer 5, dormer roof, 2787, Wall clearance 2722, Recommend a certified "Chimney Guild" inspect annually 2717, Only "vented" firelogs are allowed in bedrooms 2713, does not have a "Shut off" valve above floor (not easily accessible) 2703, is using wiring that has an "open-splice" and needs correcting 2700, is missing cover on control box 2689, Dryer gas line 2679, is too long and can trap lint at sags. Recommend metal flex or rigid pipe when repaired 2658, is old 2643, Inactive bee nest 2626, concealed with blackboard (not visible) 2580, is needed where missing 2540, works but old and no longer effective 2527, (on Oven) 2523, Range plug 2506, Front right burner 2502, Right rear coil element 2496, is exposed at junction box 2482, Dishwasher 2473, no longer supports rack when fully opened. Door springs need replacing 2472, needs adjustment or repair at latch 2456, needs doorknob and hardware repaired or replace to work properly 2436, does not align properly at Meeting-rail (where top sash and bottom sash meet). Needs repair in order to lock windows 2418, Five windows 2380, under sink at bottom shelf (from a previous leak) 2378, (left of refrigerator) 2372, sags or is warped 2351, Landing 2340, stairs to lower level 2334, is cracked in a few areas 2329, is deteriorated or weak around toilet 2328, is deteriorated or weak along bathtub 2313, is warped or buckled indication water damage 2312, is warped or buckled indicating moisture absorption 2301, Crown molding 2294, shows repair signs 2278, Towel bar 2272, is loose (wall anchor failed) 2250, Wood panels 2216, 40 2214, 84 2203, 73 2192, 62 2181, 51 2172, both heat pumps in "Cool mode" 2106, Supply 2101, at floor register 2098, rests upon ground and is rusted. May be deteriorated or will if not corrected 2086, is missing ground prong on plug 2076, (Burn Area) 2063, (upstairs) 2042, (seen from Roof, looking down liner) 1987, but shuts off prematurely 1972, on Air Handler 1970, on boiler 1957, Gas furnace 1954, Air Handler in attic 1932, is missing foam sleeve in area(s) 1925, is old and appears to have been discontinued or no longer is used 1914, Gas line 1903, at boiler 1898, was installed improperly using soft copper through wall instead of hard piping 1855, oil-fired boiler 1812, is located below ground level in crawlspace (not allowed). 1811, was tested with an amperage meter which indicates bottom element or thermostat needs replacing 1805, was empty during inspection but circuit breaker was on. Elements likely are damaged and will need replacing 1800, located 1798, orange 1752, Stop valve 1751, has a loud gurgle indicating the need for a vent (auto-vent) 1738, has an old trap that's been discontinued 1728, copper fittings 1704, Brown deposits on plumbing fixtures 1703, Blue stains on plumbing fixtures 1641, leaks at vacuum breaker 1631, main shut-off 1619, is old galvanize and has corroded wet joints 1590, Faucet at utility sink 1557, Sink supply valve 1539, leaks a stream through tub spout 1538, is reverse threaded (on is off and vice versa) 1517, Downstairs Bath 1485, GFCI (Ground Fault Circuit Interrupter) outlets 1480, at right side of home 1474, Exterior outlet 1427, at Den 1414, is missing globe 1413, is missing glass 1398, has a damaged knob, and wont stay in place 1378, Six 1370, 2nd bedroom 1361, Dining Room 1348, incorrect for refrigerator and should be changed to a three-prong grounded outlet 1292, Taped splice (not inside box with a coverplate) 1251, has been disconnected intentionally 1229, circuit breakers in main panel are 1228, circuit breaker in sub panel is 1221, 40 amp 1216, metal plumbing does not travel to soil which indicates the need for a ground wire and rod at meterbase 1196, it was blocked by 1182, Strand wire (below 40 amp) used instead of copper tubing 1173, Panel is overloaded, 1158, Burnt connection(s), 1153, Aluminum branch wiring, 1151, (in main panel), 1148, Service conductors location requires it to be placed inside piping for protection, 1127, finished 1058, possible asbestos sleeving 1053, furniture 1044, storage room 1017, Main girder 1008, leans and appears unstable 976, Recommend increase ventilation as necessary. This may involve a foundation vent fan controlled by a humidistat 945, Multiple 940, However, since opinions do vary, I recommend a structural engineer inspect 911, has been repaired which appears adequate 903, above front porch 902, above carport 891, at various areas in attic 877, Three (or more) electrical splices 874, One electrical splice is missing box and coverplate 872, loose wire ends 830, (above utility room) 825, (above Hallway) 767, has loose hardware and needs repair to avoid possible fall or collapse from ladder 757, needs adjustment to shut properly 719, has a damaged panel lid, and needs replaced to close off opening properly 713, under eave 701, Wasp bee 686, Wood Timber wall 630, upper level 548, has deteriorated at brickmold or trim (exterior). Needs repair or replace, prep and paint 535, needs strike adjustment for deadbolt and door knob to latch properly 511, Screen panel 508, French doors 503, Brickmold 502, Sillplate 487, are split or cracked in areas 469, under stairs 428, shows where paint touch up did not match completely 390, Brick banister(s) 368, Rock floor 355, has cracked in some areas (which are cosmetic) 335, has some boards that are deteriorated that needs replacing 329, not T&G (tongue and groove), and can allow some water or moisture to pass through deck floor into crawlspace 320, . Recommend wood putty prep and paint 316, and needs repair 296, is warped, 252, left side of home (facing front) 237, eaves (throughout). Recommend installing gutters and splash blocks or drain lines (buried) 211, stones 195, T-111 sheathing 171, needs paint touch up 169, Carport 165, master bedroom 122, at least 90, leaves and debris 2770, not easily. Needs cleaning 2750, (right door) 2739, is damaged at shut-off valve and needs repair 2731, We did not inspect the liner for safe operation 2724, is loose around thimble and needs to be secured and a fireproof mastic applied 2708, is not operable 2706, is "humming" and motor is hot to the touch. Fan blades are not moving properly. Needs Replacing 2704, fan shroud is missing 2694, appears defective 2686, is missing coverplate 2684, is improper gauge or thickness 2652, Gable vent 2651, various roof openings 2590, Mineral fiber (loose-fill) insulation 2546, control panel is loose or broken. Appears to still function properly 2514, Gasket seal around oven 2513, The "on" indicator light 2484, Dishwasher door 2466, Sliding doors 2462, Pantry door 2460, (at top of stairs) 2449, five windows 2389, has a burn mark 2375, (right of stove) 2359, Hardware 2326, Subfloor is weak in this area 2296, Texture 2288, Moisture meter was used and recorded 19% or higher which indicates leak has not been corrected 2269, Surround kit for shower 2258, Chair rail 2255, Tile 2236, is missing piece 2217, 41 2215, 85 2204, 74 2193, 63 2182, 52 2174, that both units are 2153, Door to access filter 2126, Safety cover for baseboard register 2122, Return piping for boiler 2066, Entertainment room 2018, Heat Pump 1989, but frequently cycles on and off 1975, Safety switch 1952, Filter access 1915, Propane line 1909, at wall unit 1905, at family room 1871, shares the same flue with wood burning, and is not allowed 1861, needs connecting properly to chimney flue 1859, propane water heater 1844, Flame/burner for 1794, green 1789, on rear wall 1787, beside water heater 1782, overhead at entry 1765, has an old style trap and should be upgraded 1739, is old cast-iron and rubber joints are oozing. 1734, drain line 1722, the well size, distance from home, or the pump size or condition etc 1710, is not connected. A new unit may be needed 1708, odor remains in water which may indicate unit is not working properly 1687, Knock-out cover for drain line 1650, Knob for 1621, under master bath 1613, has been repaired improperly 1583, is "stripped" and doesn't turn off properly 1575, drips and needs repair 1551, Tub spout diverter 1549, Shower head 1537, loose and needs repair 1533, from possibly hard water 1509, is old and needs resurfacing (Cosmetic) 1507, is chipped (Cosmetic) 1493, Sink Base cabinetry 1459, not grounded. Recommend upgrade to GFCI (Ground Fault Circuit Interrupt) outlet 1452, did not work or no power to outlet 1451, no longer seals off air when closed and energy loss can occur when not in use 1443, Control knob 1422, in hallway 1390, has a damaged "cover-plate" 1377, Shared Bath 1367, at end of hall 1363, Utility Room 1353, "Two-prong" outlet is 1310, Oven 1275, in garage 1255, common hallway to bedrooms 1220, 30 amp 1194, Main panel 1190, circuit breaker 1162, Damaged breaker(s), 1132, All 1119, personal items 1103, (along rear of home) 1066, needs screen 1030, Typical settlement cracks 1015, Repairs failed to adequately replace damaged girder with a new one 1004, old and weak 1003, undersized 995, This repair is inadequate and should be corrected using a licensed contractor 993, Laundry room 924, Recommend a structural engineer evaluate 917, (facing front of home) 892, above Master bath 878, missing boxes and coverplates 873, needs placing inside a box with a coverplate 869, Several 860, within five feet of attic access 841, Some areas are weak or brittle and need re-enforcement 812, around furnace vent piping 808, around plumbing exhaust pipe 787, at or near top of stairs 783, has a stair tread loose 751, (above stairs to lower Level) 724, missing paint on panel 691, fan is noisy indicating bearings or motor may need repair or replacement 682, Retaining wall 680, has some loose bricks, and needs repair 676, has been damaged by perhaps a vehicle, and needs repair 651, uneven, and can be a tripping hazard 644, to be caulked with silicone against foundation wall 639, hole (see photo) 607, needs caulking along top of trim or brickmold 600, "left" door (from outside), 578, missing door stop 577, needs hingestop replaced 530, reveals daylight at threshold when latched. 523, Pool enclosure 494, and needs putty, prep and paint 464, Recommend a structural engineer to inspect 448, (at top) 426, shows evidence of a leak, and needs repair 422, loose, and needs mortar where missing 411, near top of stairs 358, loose, and missing in areas 343, 2x6 decking 341, loose at steps, and needs repair 337, has green algae growth, and can deteriorate wood. Recommend clean prep and seal surface 332, sags at support posts, and needs repair 323, loose, and needs repair 288, Brick 263, Soffit panel 246, front (right of main entry) 245, various areas 242, left side 228, is deteriorated 224, 1 1/2 inch 187, secured with adhesive instead of fasteners 172, trim is not painted 160, kitchen 140, in rear of home 138, soffit vent screens 106, right side of chimney 96, Metal drip edge 86, chimney area 79, visible caulking. It appears that leak has been corrected 56, has more than one color 45, This is typical of older construction where possibly rafters were undersized and created sag 32, front of home 15, left corner 1, rear of home, 2766, Damper linkage 2762, is missing a clamp or lock that forces lid to stay open (required for Vented Gas/LP logs) 2757, will fall out of alignment when operating 2726, is missing a protective "Collar" at ceiling 2725, needs flue pipe cleaned (from stove to chimney) 2696, Recommend licensed electrician to inspect 2663, is loose and needs to be securely mounted 2639, Recommend contact a pest control company 2634, at various areas 2625, concealed with plastic (not visible) 2613, is about ten inches thick or just over 36.6 R-Value 2605, is about 16 inches thick or 50 R-Value 2592, old and has settled, and less than six inches in thickness remains. Recommend new insulation be added 2589, Rock Wool (Batts) insulation 2559, knob is broken 2549, Range hood fan 2504, Broiler element 2479, power switch is too low, and does not prevent children from operating 2474, leaks when operated. Needs repair or replace 2468, is loose and needs repair or replace 2417, Four windows 2395, Recommend caulk around sink rim with silicone 2386, is chipped 2360, Sink base 2338, is loose and needs tighten or repair 2332, was cut around toilet (rather than removing toilet) and needs caulking around base of toilet 2308, squeaks in areas (nuisance only) 2300, Panels 2295, Drywall 2268, Surround kit at bathtub 2251, Beaded board panels 2243, shows wet stains indicating moisture or intrusion did or still may occur 2218, 42 2205, 75 2194, 64 2183, 53 2178, range in temperature drop is normal 2168, Drain in floor 2161, Water or overflow tray 2124, Radiator 2121, Supply piping for boiler 2116, is missing insulation in areas 2094, is failing 2088, cord 2074, Ash dump lid 2073, Fire-bricks 2062, Bedrooms 2057, Clay liner 2053, "Stand Alone" 2031, Downstairs bath 2003, is brittle 1984, will fire, 1969, did not shut off unit when service door was removed 1958, Gas-fired boiler 1953, Air Handler 1950, Test on supply and return air temperatures (Ambient air) 1944, Condensation pump 1926, is inoperative and will need repair or replace to work 1910, in living room 1862, does not appear to vent properly 1848, is wrong diameter or size. Must be 3/4 inch diameter 1833, Rust signs can appear from water that spilled during an element change-out, or from condensation 1774, "gurgles" indicating a possible need for an air-vent under sink 1686, Waste line 1681, needs removing 1668, and linkage 1614, (caulked) 1607, is weak and needs better support 1587, Concrete sink (old) 1585, develops an "Air-lock" when spray nozzle is operated and needs repair 1582, is weak in volume and pressure 1572, Hot supply Line 1562, is rusted and has leaked before sealing itself temporarily 1556, Toilet supply valve 1515, Private Bath 1475, Receptacle outlet 1460, showing "reversed polarity," and may not be grounded or a loose ground connection 1432, "flickers" indicating a loose connection at fixture or switch 1402, is noisy 1397, is missing knob 1307, whole house fan 1281, above water heater 1247, Also, main disconnect is at meterbase outside (for your information) 1238, is missing screws 1219, 20 amp 1195, Sub panel 1125, no access behind wall or ceiling covering 1115, Existing sump pump location 1106, at basement entry 1048, wood 1043, unfinished basement 1013, in crawlspace 1010, missing block and mortar 994, While this repair will work, most tradesmen will recognize it as sub-standard 987, failed to adequately replace damaged wood with new wood members 980, Existing repair to floor joists 968, Washer/Dryer 939, These cracks do not appear significant to require repairs at this time 906, repaired improperly 894, above Master bedroom 867, Possible Asbestos material 834, The damage to this area is not significant to require replacing at this time. Recommend waiting until roof covering is replaced, so long as leak remains corrected 827, (above Kitchen) 822, (above Guest bath) 818, around exhaust fan piping 790, needs re-nailed or tightened 784, has some stair treads loose 725, missing paint on trim and panel 723, missing paint on trim 709, at front of home 703, Carpenter bee 663, Tile walkway 653, has dropped or settled causing a steep or uneven step. Needs repair 652, is pitted in areas and needs repair and re-coat with sealer 635, Three-door garage 633, Garage door 626, (all doors) 614, is damaged at panel 573, Dining room 561, damaged at muntin grille (also called divider grille) 549, torn or damaged 539, was not shimmed properly at strike jamb (too wide) and does not latch securely 476, Wood column (s) 465, can hold moisture due to covering installed underneath. Recommend remove to prevent damage 460, needs mortar where loose or missing 452, improperly supported 450, needs repair 435, Slate shingles on wall 429, shows were flat paint was mistakenly used to touch-up semi-gloss 396, shows paint failing or peeling, and needs repair 379, Guardrail at steps 373, Indoor/Outdoor carpet 344, 5/4 decking 312, reveals daylight when latched 311, missing weather stripping 300, is missing hardware, 259, weathered 229, is missing 183, deteriorated. Needs replacing 182, Sealant 156, Skylight 150, needs re-caulking 149, with vent flap appears painted shut. Did not inspect 118, Unable to determine if leak has been corrected. Recommend monitor when it rains 112, appears good but will need periodical maintenance coatings 68, Recommend repair or replace as needed 62, valley 52, are missing 8, right side (facing front) 2780, is warped, or twisted 2779, (Cosmetic) 2768, Damper lever 2711, (burner would not ignite) 2690, Dryer vent piping 2681, uses a "lint trap kit" and does not vent to the outside 2631, approximately half of home 2607, and was installed with "Paper or Kraft" face up. Paper side should always face the "Heated Space" or condensation could occur 2600, is about eleven inches thick or 34.5 R-Value 2562, had storage items inside and was not being used as a compactor. We did not remove these items to inspect. Trash compactor was inoperable at inspection 2541, needs cleaning 2500, Front right coil element 2493, uses a plug for wall outlet, and plug is attached incorrectly. 2485, Dishwasher control knob 2458, Small bedroom 2455, is missing doorstop 2448, four windows 2428, will not stay up without a prop. Needs repair to operate properly 2406, behind sink 2390, is painted over 2358, Retractable door 2344, third story stairs 2339, is missing. Recommend install rail with maximum space between pickets to be four inches 2331, is warped or buckled indicating water damage 2264, is bowed or bulges. Possibly from poor nailing or moisture absorption 2219, 43 2206, 76 2195, 65 2184, 54 2154, is leaking at condensation line 2128, is weak 2107, Return 2093, is disconnected 2061, same location 2059, Flue Pipe 2044, Recommend installing a liner if you plan to burn wood 2027, works but knob is missing 2020, (no power) 2014, Heat fins 2013, Safety cover 1998, oil smell may indicate 1986, is old and inefficient 1971, on furnace 1963, and needs a more detailed inspection 1955, Oil furnace 1927, was working but is old and needs cleaning or servicing 1924, was not in operation or use during inspection. We did not inspect for proper operation 1919, Gas Tracer (device) 1913, at patio outside 1901, Recommend repair as necessary by a qualified professional 1887, Our company did not inspect tank for leaks nor did we test soil 1877, needs cartridge replaced 1870, fails to rise 1/4 inch per foot and may need re-locating or a powervent installed 1858, gas water heater 1851, is piped horizontally 1823, cold supply inlet 1785, at furnace room 1723, the springs size, distance from home, size of cistern (holding tank), debris obstruction etc 1721, old galvanized piping that is corroded inside. This problem will eventually become worse 1651, Knobs for 1649, Outside water faucets 1646, Hose bib 1635, threads are stripped (from pliers) 1611, While repair is amateur, their are no leaks at present 1569, Aerator on faucet spout 1564, Lever on faucet 1548, Tub faucets 1528, Main bath 1506, has a hairline crack. It may become worse if moved or "jarred." Appears stable at present 1471, Meter base 1470, Window 1463, showing loose ground connection or no ground 1462, wont "Trip" when tested, needs repair 1424, in Office 1421, in Den 1394, has an old or weak "lever" (recommend replacing) 1388, is loose in wall 1379, "Two-prong" outlets are 1373, Master Bath 1324, in closet 1323, in washer dryer closet 1318, Propane wall heater 1298, Grounded outlet needed (instead of light fixture adapter) 1278, in bonus room 1236, hallway 1230, circuit breakers in sub panel are 1208, clamp is loose 1205, outside 1169, Location of main panel, 1168, Knock-outs missing on panel 1145, drive is lower than 15 feet 1124, insulation 1110, uses a nearby light fixture adapter and should have it's own GFCI outlet 1079, Foundation vent 1064, missing screens 1032, Uneven settlement crack 1020, Support post 1019, Girder 1006, rusted through (deteriorated) 979, Recommend repair as necessary 971, home 944, Horizontal 890, within "Five feet" of attic access 856, Plywood sheathing 846, Refer back to page one notes on roof covering 836, which appear adequate 835, which appears inadequate 826, (above Living room) 819, around grease fan piping 803, 2x12 rafters 799, 2x4 rafters 791, needs a handrail for safety 779, at upper level living area, 776, in bedroom left of stairs, 752, (above stairs to upper Level) 735, (right of stairs) 712, at porch ceiling 670, is old and deteriorated, and needs replacing 638, Springs for garage door (s) 599, Family room 591, is damaged at bottom panel 579, was installed out of square 555, has a broke glass 536, does not lock and needs repair or replace hardware 524, Utility room 499, most windows 492, steps to basement 480, Steel column (s) 456, deteriorating at column base plate. Needs repair to preserve 443, Wood plank ceiling 439, Log siding on wall 437, Wood shingles on wall 424, loose, and needs tightened or re-fastened (minor) 402, Needs repair or replace 399, loose at steps, and needs tighten or fasten 383, Metal guardrails 375, Brick floor 371, EPDM (rubber membrane) floor 347, T&G (tongue and groove) flooring 315, Outside entry to lower level 314, Outside basement entry door 307, is damaged at screen panel, 278, installed improperly or not according to standard workmanlike practices 272, deteriorated, and needs replacing 234, seams appear to leak. Unable to determine if seams have been repaired 230, is loose 202, Slate siding 198, Board and batten style siding 179, Cement crown 130, garage roof 108, may need re-coating before five years 102, half of roof (front side) 85, Unable to determine for certain that leak has been corrected 78, Roof shingles 64, the "entire roof" 60, is damaged 59, has excessive "moss or algae" growth 57, older on one side 23, (Asphalt shingles on top of wood shakes) 6, storage building sub exterior 1, ROOFING, DRAINAGE, CHIMNEYS$ 0$ 0$ 0 1, A, N/A 0, B, NONE S, C, MISSING I, D, BLISTERING J, E, PAINT FAILING F, F, DETERIORATION E, G, PHYSICAL DAMAGE M, H, POORLY REPAIRED C, I, FUNGUS OR ALGAE H, J, PREMATURE AGING G, K, WEATHERED EDGES A, L, TOO STEEP TO WALK K, M, INSTALLED IMPROPERLY N, N, NEEDS SEALANT APPLIED D, O, AMATEUR WORKMANSHIP T, P, NEEDS CAULKING AT SEAMS W, Q, TYPICAL CRACKS V, R, NEEDS TIGHTENED P, S, TAR APPLIED INSTEAD OF FLASHING R, T, MORTAR MISSING IN AREAS X, U, RE-COAT CEMENT CROWN L, V, IMPROPER ROOF COVERING FOR SLOPE OF ROOF Y, W, RECOMMEND A "RAIN CAP" OR "SPARK ARRESTOR" . . 1, EAVE, SIDING, FOUNDATION WALLS$ 0$ 0$ 0 1, A, N/A 0, B, NONE Q, C, LOOSE S, D, MISSING O, E, RUSTING J, F, PAINT FAILING F, G, DETERIORATION U, H, NEEDS CLEANING G, I, WEATHERED EDGES K, J, INSTALLED IMPROPERLY N, K, NEEDS SEALANT APPLIED T, L, CAULK SEAMS Z, M, SCREENS INSTALLED V, N, NEEDS TIGHTENED 2, O, DAMAGED 4, P, MORTAR MISSING . . 1, DECKS, BALCONIES, PORCHES, STOOP, STEPS, RAILINGS$ 0$ 0$ 0 0, A, N/A H, B, WEAK C, C, LOOSE D, D, MISSING B, E, EROSION I, F, DANGEROUS G, G, DETERIORATED K, H, NEEDS JOIST HANGERS Q, I, AMATEUR WORKMANSHIP J, J, IMPROPERLY SUPPORTED N, K, NEEDS RE-NAILING / TIGHTEN P, L, TYPICAL SETTLEMENT CRACKS M, M, NEEDS SEALANT W, N, 4" SPACE BETWEEN PICKETS NEEDED Y, O, NEEDS POINTING UP WITH MASONRY WHERE MISSING 1, P, NO HANDRAIL . . 1, WINDOWS, DOORS$ 0$ 0$ 0 2, A, N/A E, B, OLD H, C, WEAK 1, D, NONE C, E, LOOSE F, F, DAMAGED L, G, PAINT PEELING T, H, NEEDS ADJUSTMENT R, I, SCREEN TORN OR DAMAGED U, J, WEATHER STRIPPING NEEDED S, K, CLOUDY/SEAL BROKEN V, L, DOOR KNOB/LATCH ADJUSTMENT NEEDED 3, M, MISSING . . 1, GARAGE$ 0$ 0$ 1 Main Level Garage,Lower Level Garage,Attached Garage,Detached Garage 0, A, LIGHT COVER MISSING 1, B, TEMPORARY WIRING 2, C, IMPROPER WIRING 3, D, DAMAGED 4, E, NON-OPERATIONAL 5, F, MANUAL DOOR 6, G, DETERIORATED 7, H, WEATHERED 8, I, DELAMINATED 9, J, MOISTURE ABSORPTION 10, K, PEELING 11, L, BREACH . . 1, DRIVEWAY, RETAINING WALLS, LANDSCAPING$ 0$ 0$ 0 0, A, NEGATIVE DRAINAGE 1, B, DETERIORATED 2, C, UNEVEN SURFACES 3, D, TRIPPING HAZARD 4, E, SETTLEMENT CRACKS 5, F, TYPICAL CRACKS 6, G, LEANING 7, H, OLD . . sub interior 1, ATTIC AND ROOF STRUCTURE$ 0$ 0$ 0 APARTMENT 1, A, N/A 0, B, NONE O, C, NO ACCESS 2, D, SEALED OFF I, E, SPLIT OR CRACKED A, F, POORLY ACCESSIBLE E, G, APPEARS CORRECTED C, H, EXTRA SUPPORTS NEEDED D, I, DETERIORATED / DAMAGED B, J, CRAMPED / RESTRICTED AREA M, K, LIVABLE "FINISHED ATTIC SPACE" N, L, UNIVERSAL DAMPER INSTALLED F, M, WATER STAINS AROUND CHIMNEY G, N, SPLICE OR JUNCTION BOX MISSING COVER L, O, RECOMMEND INSTALLING A UNIVERSAL DAMPER H, P, SPLICES NEED PLACING IN METAL BOX WITH COVER (S) J, Q, ROOF VENT OPENINGS NEED SCREENS . . 1, STRUCTURAL COMPONENTS$ 0$ 0$ 0 1, A, N/A 0, B, NONE A, C, AMATEUR WORKMANSHIP B, D, INADEQUATE SUPPORTS C, E, LACK OF SUPPORTS D, F, DETERIORATED AREAS E, G, IMPROPER REPAIRS MADE F, H, FOOTINGS UNDERMINED H, I, DAMAGED 3, J, CRACKED GLASS I, K, POTENTIALLY UNSAFE J, L, SETTLEMENT CRACKS K, M, STRESS CRACKS LARGE ENOUGH FOR CONCERN. (SEE NOTES) L, N, JOIST HANGERS OR LEDGERS RECOMMENDED M, O, DEBRIS NEEDS TO BE REMOVED N, P, FOUNDATION VENTS TOO LOW TO THE GROUND Q, Q, 6 MIL THICK PLASTIC RECOMMENDED R, R, RECOMMEND INCREASE VENTILATION S, S, MILDEW OR ODOR PRESENT U, T, VENTS NEED SCREENS OR REPLACE V, U, PARTIAL SLAB AND CRAWLSPACE 2, V, N/A 4, W, NOT VISIBLE . . 1, ELECTRICAL$ 0$ 0$ 0 4, A, SEE NOTES PREVIOUSLY MENTIONED 1, B, N/A 0, C, NONE A, D, LOOSE B, E, IMPROPER SPLICES C, F, EXPOSED WIRING D, G, UNSAFE HAZARD E, H, MISSING F, I, DAMAGED G, J, NEEDS CLEANING OR SERVICING H, K, EQUIPMENT OLD I, L, NON-OPERATIONAL J, M, POSSIBLE ASBESTOS K, N, SUGGEST ENCAPSULATING WITH 6 MIL THICK PLASTIC L, O, AMATEUR WORKMANSHIP M, P, CIRCUIT BREAKER "OFF" N, Q, RECOMMEND A LICENSED ELECTRICIAN TO INSPECT Q, R, IMPROPER REDUCTION IN SIZE R, S, DID NOT INSPECT 2, T, RUSTED IN AREAS 3, U, FUSES . . 1, PLUMBING$ 0$ 0$ 1 0, A, AMATEUR WORKMANSHIP 1, B, TEMPORARY REPAIRS MADE 2, C, FUNCTIONAL FLOW NOT MET 3, D, WATER NOT ON DID NOT INSPECT 4, E, DID NOT INSPECT 5, F, NON-OPERATIONAL 6, G, PIPING OLD 7, H, CIRCUIT BREAKER OFF 18, I, SEE ELECTRICAL COMMENTS 8, J, GAS NOT ON 9, K, MISSING 10, L, COULD NOT LOCATE 11, M, DAMAGED KNOB 12, N, DID NOT INSPECT SOIL 13, O, DRIP AT CONNECTION 14, P, ACTIVE LEAKS 15, Q, CORROSION 16, R, WET CORRODED JOINTS 17, S, DRIP LEAK 19, T, WHITE DEPOSITS 20, U, BACKDRAFT 21, V, RUSTING 22, W, STRAPS NEED REPAIR . . 1, HEATING$ 0$ 0$ 0 0, A, EXPOSED WIRING 1, B, DAMAGED 2, C, NEEDS CLEANING OR SERVICING 3, D, EQUIPMENT OLD 4, E, NON-OPERATIONAL 5, F, CIRCUIT BREAKER OFF 6, G, RECOMMEND HVAC TO INSPECT 7, H, DID NOT INSPECT 8, I, N/A 9, J, WHITE DEPOSITS 10, K, RUSTING 11, L, BACKDRAFT 12, M, NONE 13, N, SEALED OFF . . 1, CENTRAL AIR CONDITIONING$ 0$ 0$ 0 0, A, MISSING 1, B, EQUIPMENT OLD 2, C, ABNORMAL NOISE 3, D, DAMAGED 4, E, NOT LEVEL 5, F, TAPE FAILING 6, G, DISCONNECTED 7, H, NON-OPERATIONAL 8, I, CLOGGED OR DEFECTIVE . . 1, INTERIORS$ 0$ 0$ 0 . . 1, BUILT-IN APPLIANCES$ 0$ 0$ 0 0, A, NON-OPERATIONAL 1, B, DAMAGED 2, C, HAZARD 3, D, SEIZED 4, E, OLD . . 1, INSULATION AND VENTILATION$ 0$ 0$ 0 0, A, NOT INSULATED 1, B, MOISTURE 2, C, CONDENSATION 3, D, MISSING 4, E, IMPROPERLY VENTED 5, F, SEALED OFF 6, G, NON-OPERATIONAL 7, H, DEFECTIVE 8, I, HAZARD . . 1, FIREPLACES$ 0$ 0$ 0 MAIN LEVEL,LOWER LEVEL,UPSTAIRS,UPPER LEVEL,MASTER BEDROOM,GUEST BEDROOM,LIVING ROOM,DEN,FAMILY ROOM,DINING ROOM 0, A, NO MANTEL 1, B, MISSING MORTAR 2, C, SEALED OFF 3, D, NEEDS REPAIR 4, E, MISSING 5, F, UNIVERSAL DAMPER 6, G, SEIZED 7, H, LOOSE 8, I, PEELING PAINT 9, J, DAMAGED . . 1, COMPLIMENTARY PHOTO VIEWS$ 0$ 0$ 0 . . questions NA, exterior, 1 ARE THERE ANY NOTICEABLE SWAYS OR SAGS IN THE ROOF SHEATHING F, E, A This question most always is no (recognizing typical sways or dips as normal). Its purpose is to alert you "where" to look in attic. Sags can occur where a plywood clip is missing, damaged truss or rafter spaced a little too far or bad crown in wood. Or a weak piece of plywood. Undersized wood such as a "2x4 rafter" spanned too far can create sag. A knee wall or reinforcement would be suggested. See Discoveries and Comments. . Roof sheathing deteriorated at chimney due to improper or lack of "Step and Cap" flashing. . . Roof sheathing somewhat deteriorated or soft at chimney. Leak appears corrected. Not cost effective to perform repairs until next roof. Maintenance caulking at chimney flashing will be needed periodically. . . Roof sheathing deteriorated along perimeter edge near gutters at *LOCATION* possibly due to leaves and debris becoming clogged in gutter at times. This will involve some roof sheathing and shingle removal and replacement. . LOCATION=0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22 . Roof has different types of roof covering installed over each other *CHOOSE1*. This is not considered standard or proper. The life of shingles may wear prematurely resulting in early replacement. The manufacturer of shingles will most likely not guarantee covering. . CHOOSE1=23,24 . Area of roof sheathing *PROBLEM* at *LOCATION*. *RECOMMEND*. . PROBLEM=25,26,27,28,29,30,31 LOCATION=32,33,7,8,34,9,35,36,37,15,16,17,18,11,12,13,14,38,6,19,20,21,22,39 RECOMMEND=40,41,42,43,44 . Some dips or sags on roof in areas. *SIGNIFICANCE*. . SIGNIFICANCE=45,46,47,48 . Metal roofs and some "Wood Shake" roofs, were usually installed over wood furring strips spaced in rows about 16 inches to "two feet" apart instead of roof sheathing or common boards. Removing metal roof in order to install conventional asphalt shingles will require installing roof sheathing throughout or adding "Common boards" at varying widths to fill in gaps. . . Also a gap between fascia and roof sheathing exists which allows insects or bees to enter attic. . . NA, exterior, 1 ARE THERE MULTIPLE LAYERS OF ROOF COVERINGS 1 Check edge of different sides of main roof, and any separate roofline. Multi layer roofs aren't inherently wrong or bad (Maximum number of layers depends on your area). Inspect areas closely around chimney and vent pipes, and roof sheathing edges that may have been overlooked at time of "re-roof." See Discoveries and Comments. . Three or more layers of roof covering exist. *RECOMMEND*. . RECOMMEND=49,50,51 . NA, exterior, 1 DOES THE ROOF COVERING APPEAR TO BE IN GOOD CONDITION I, E, M, H, A, L Check for blisters or missing granules or swelling at rain tabs or covering (due to hail damage, poor ventilation or age), Mump-like appearance or hairline cracks through covering or shingle (due to possible manufacturer defect). Point out areas that need caulking (nail heads at ridge caps, roof and wall junction, at exhaust pipes and vent hoods. See Discoveries and Comments . *CHOOSE_ROOF* *PROBLEM* at *LOCATION*. *RECOMMEND*. . PROBLEM=52,53,54,55,56,57,58,59,60,29 LOCATION=36,61,62,63,32,33,64,7,8,34,9,35,10,37,11,12,13,38,15,16,17,18,65 RECOMMEND=66,67,68,40,41,69,70,71,72,73 CHOOSE_ROOF=74,75,76,77,78 . Shingles around chimney area on *LOCATION* shows signs of a repair attempt due to *CHOOSE1*. . CHOOSE1=79,80,81,82,83,84,85 LOCATION=32,33,7,8,34,9,35,10,37,15,16,17,18,19,20,21,22 . The roof covering is old, and the life of covering has expired. The covering does need to be replaced. While it could last a year or so, some areas may need patching with tar as leaks develop. . . We cannot determine if metal awnings are leak proof. . . Flat roof (Less than 3/12 slope) at *LOCATION* has improper style roof covering (three-tab shingles). It should have either selvage, roll roofing, rubber membrane or an approved covering for a flat roof. The roof may leak in heavy rain or ice may dam in winter causing a leak. . LOCATION=32,33,7,8,34,9,35,86,37,15,17,18,11,12,13,14,38,16,6,19,20,21,22 . The Shingles do not overhang edge of roof properly (one-inch recommended) along eave and fascia. Recommend install drip edge to help water travel into gutters. . . Excessive granules coming off of shingles. This is usually from inadequate attic ventilation or possibly a manufacturer defect. *RECOMMEND*. . RECOMMEND=87,88 . Roof covering has hairline cracks in various areas. This is possibly from a manufacturer defect. Roof could leak. Recommend repair or replace. . . Roof covering shows a mump-like appearance indicating a possible manufacturer defect. These areas will eventually blister and roof will need replacing. . . Shingles on *LOCATION* did not tuck under siding. Instead, shingles were folded up to lie against siding. Silicone caulking needed along top edge of shingles. This area will eventually need caulking again as the caulk ages. . LOCATION=17,37,15,16,35,34,9,7,8,32,33,6,19,20,21,22 . Area at *LOCATION* shows caulking or repair signs. Given the fact that roof is fairly new, the original installation has failed and should be replaced properly rather than patched or caulked. Patching a roof with caulk or tar is only temporary, and will need periodical maintenance until roof is properly repaired . . LOCATION=32,33,7,8,34,9,35,10,86,37,15,16,17,18,11,12,13,14,38,6,19,20,21,22 . Could not inspect roof covering at *LOCATION* due to *CHOOSE_WEATHER*. . CHOOSE_WEATHER=89,90,91,92,93 LOCATION=64,32,33,7,8,34,9,35,10,86,37,15,16,17,18,11,12,13,14,38,6,19,20,21,22 . Roof covering deteriorated. Needs tear off and replace. Recommend next roof to have 30 lb builders felt with metal drip edge around perimeter of roof. Shingles to have a one-inch overhang and increase roof ventilation. If any chimneys are involved, they should properly have "Step and Cap" flashing installed. New shingles should tuck under siding (where appropriate). Laying the shingle against siding will require caulking the edge and is only temporary. The caulk will dry out and crack resulting in leaks if not regularly maintained. Siding may need removing or replacing along roof line and wall junctions during installation in order to tuck shingles. . . Wood shingle/shake roof has deteriorated in areas exposing felt, and can allow water to travel under the shingles causing a leak. The area inspected was at *LOCATION*. We did not walk on roof for fear of damaging shingles further. Recommend a roofing contractor specializing in wood shakes or wood shingles to inspect further. . LOCATION=32,33,7,8,34,9,35,10,86,37,15,16,17,18,11,12,13,14,38,6,19,20,21,22 . NA, exterior, 1 IS DRIP EDGE INSTALLED ALONG ROOF PERIMETER 1, 0, F, E, G, V While it's not essential, it protects the roof sheathing edges at gutters, and it is recommended if shingles doesn't have a one-inch overhang. Lift the shingles gently at gutters to inspect the top edge of fascia and roof edge as needed. See Discoveries and Comments . *DRIP/EDGE* *PROBLEM* along rake/eave at *LOCATION*. . PROBLEM=28,29,30,31 DRIP/EDGE=94,95,96 LOCATION=32,33,7,8,34,9,35,10,37,11,12,38,15,16,17,18,19,20,21,22 . The roof eave has an air space or gap between the drip edge and fascia board that can allow insects or rodents to enter into the attic. I recommend a screen or wider fascia board be installed to close off properly. This area is at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,10,37,11,12,13,38,15,16,17,18,19,20,21,22 . NA, exterior, 1 ESTIMATE LIFE EXPECTANCY OF ROOF COVERING 5 YEARS OR MORE Will the roof covering last for at least five years at the present condition (excluding maintenance caulking where needed such as chimney tarred areas or where you specify)? See Discoveries and Comments . Estimate only *HOW_MANY* years remaining on *LOCATION*. This does not include normal maintenance caulking at any roof junction and flashing areas. . HOW_MANY=97,98,99,100 LOCATION=101,102,103,7,8,34,9,10,11,12,13,38,15,16,17,18,104,105,106,107,6,19,20,21,22 . Metal roof covering has paint/sealant applied, and *FACTOID*. . FACTOID=108,109,110,111,112 . Metal roof covering is dented or damaged at *LOCATION*. I am unable to determine if this area will leak. . LOCATION=32,33,7,8,34,9,35,86,37,15,16,17,18,11,12,13,38,6,19,20,21,22 . See comments on roof covering above. . . NA, exterior, 1 FLASHINGS 0, S, F, E, M, K, N, D, T, V, P . Chimney is not flashed properly. *CHOOSE1*. . CHOOSE1=113,114,115,116,117,118,119,120,121 . Chimney has no step or cap flashing and needs repair. Roof likely is leaking at present. . . Chimney flashing is loose and needs repair. . . Shingles around chimney area on *LOCATION* shows signs of a repair attempt due to *CHOOSE1*. . CHOOSE1=79,80,81,82,83,84,85 LOCATION=32,33,7,8,34,9,35,10,37,15,16,17,18,19,20,21,22 . Rock chimney has been tarred instead of using metal flashing due to the inability to install flashing into rock. Recommend "Peel N Seal" be used (a foil backed pliable sheet of tar) next roof replacement or when desired. Peel N Seal can be bought at Contractor supply stores. . . NA, exterior, 1 ROOF VENTILATION 0, S, K, V Check ridges and roof- vents for loose seams or lifted nails. Check plumbing vent boots or flashing. Familiarize the roof location of plumbing vents as they relate inside at kitchen and baths and laundry to ensure proper venting (unless an "auto-vent is installed under sink) See Discoveries and Comments . Ridge vents need nailing tight, and then apply silicone caulk to the nail heads. . . Ridge vent missing *HOW_MANY* end cap (s) at *LOCATION*. . HOW_MANY=122,123,124,125,126,127,128 LOCATION=129,34,130,104,105,17,35 . Ridge vent damaged at *LOCATION*. . LOCATION=129,34,130,104,105,17,35 . Turbine vent(s) on roof is rusted and no longer turns freely. Recommend repair or replace *HOW_MANY*. . HOW_MANY=123,124,125,126 . *VENTS* *PROBLEM* at *LOCATION*. . PROBLEM=28,29,30,31,131 VENTS=132,133,134,135,136,137,138 LOCATION=139,140,141,142,143,144,145 . Roof covering has recently been replaced and more ventilation should be added to promote life expectancy. . . Recommend increasing roof ventilation when the next roof covering is installed. . . NA, exterior, 1 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS 1, 0, F, E, M, A, V, P, R, X, Y . *EXTERIOR-SKYLIGHT* *PROBLEM* at *LOCATION*. . PROBLEM=146,147,148,149,150,151,152,153 EXTERIOR-SKYLIGHT=132,133,134,154,155,156,157 LOCATION=158,159,160,161,162,163,164,165,166,167,34,168,19,20,21,22,169 . *INTERIOR-SKYLIGHT* *PROBLEM* at *LOCATION*. . PROBLEM=147,170,148,171,172,149,173,174,175 INTERIOR-SKYLIGHT=132,133,134,154,155,156,157 LOCATION=158,159,160,161,162,163,164,165,166,167,34,168,19,20,21,22 . *STAIN/PAINT/SEAL* on chimney chase is failing and needs prep and re-coat *LOCATION*. . LOCATION=176,177,139,140,141,142,19,20,21,22 STAIN/PAINT/SEAL=178,179,180,181,182 . Metal rain cap on chimney crown is *PROBLEM*. . PROBLEM=183,184,185,186,187 . *CHIMNEY* *PROBLEM* and needs repair. . CHIMNEY=188,189,190,191,192,193,194,195,196,197,198,199,200,201,202,203,204,205,206,207 PROBLEM=28,29,30,208,31,209,210,211,212,213,214,215,216,217,218 . Chimney mortar and bricks are deteriorated in attic and is considered unsafe to use. Recommend a certified chimney sweep inspect further. . . Plumbing vent pipe (through roof) needs flashing boot replaced (*INCH* diameter) on *LOCATION*. *MORE*. . MORE=219,220,221,222,223 INCH=224,225,226,227 LOCATION=32,33,7,8,34,9,35,10,37,11,12,13,14,38,15,16,17,18,19,20,21,22 . Plumbing vent pipes need caulking around perimeter of pipe and boot where boot flange has failed. . . Plumbing rough in "Cap" was never removed from pipe on roof. Needs removing. . . Did not locate any plumbing vent pipes which may prevent proper drainage into septic. Recommend a plumber to troubleshoot further. . . NA, exterior, 1 CONDITION OF RAIN GUTTERS 0, S, J, F, E, M, K, N, T, V Check for cleaning and check gutter connections. Are there gutters and downspouts at every possible location. Any loose or damaged? Any sloped the wrong way? Any daylight behind gutter or drip spots on bottom of fascia? If so, check for proper shingle overhang. See Discoveries and Comments . Gutters appear intact but due to the lack of recent rain, I am unable to determine if gutters leak at seams or spills water. . . Gutter *PROBLEM* at *LOCATION*. . PROBLEM=60,228,229,230,231,232,233,234,235 LOCATION=236,32,33,7,8,34,9,35,10,37,11,12,13,15,16,17,18,6,237,19,20,21,22 . Gutter appears to leak at seam on *LOCATION*. Recommend cleaning and apply gutter sealant or epoxy. . LOCATION=32,33,7,8,34,9,35,10,37,11,12,13,15,16,17,18,6,19,20,21,22 . Gutters and drain lines are needed. . . Gutter is rusted and deteriorated in various areas throughout. Needs replacing. . . Gutters are holding water due to *PROBLEM* and should be corrected. Location is at the *LOCATION* of home. . PROBLEM=238,239 LOCATION=240,241,242,243 . Gutter screens *LOOSE/MISSING* at *LOCATION*. . LOOSE/MISSING=31,30,244 LOCATION=32,33,7,8,245,34,9,35,10,37,15,16,17,18,6,19,20,21,22 . Gutter screens present but failed in areas. Gutters need cleaning and re-install screens. . . Leaves and debris need cleaning from roof (above gutter screens). . . Gutter needs to be tightened against fascia and sealed at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,10,37,15,16,17,18,6,19,20,21,22 . The overhang on shingles need extending with drip edge at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,10,37,15,16,17,18,6,19,20,21,22 . End cap missing on gutter at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,10,37,11,12,13,15,16,17,18,19,20,21,22,38 . Home is not designed for gutters. (See landscape and drainage) . . NA, exterior, 1 ARE DOWNSPOUTS OR DRAINAGE PROVIDED PROPERLY 0, S, F, E, M, K, D, V Make sure all downspouts appear to carry water away from home. Mention any questionable areas and recommend "Monitor during heavy rain" if necessary. See Discoveries and Comments. . Loose downspout needs securing to wall at *LOCATION*. . LOCATION=246,247,248,249,250,251,252,253,34,9,35,37,17,18,19,20,21,22 . Downspout *PROBLEM* at *LOCATION*. . PROBLEM=28,31,254,255,256,29 LOCATION=33,246,247,248,249,250,251,252,253,257,34,9,35,37,17,18,6,19,20,21,22 . Downspouts need elbows and splash-blocks at *LOCATION*. . LOCATION=246,247,248,249,250,251,252,253,34,9,35,37,17,18,6,19,20,21,22,258 . Downspout needs extension and a buried drain line to carry water away from home at *LOCATION*. . LOCATION=246,247,248,249,250,251,252,253,34,9,35,37,17,18,6,19,20,21,22 . Ground drain-line has settled and pulled loose from downspout on *LOCATION*. Needs re-connecting. . LOCATION=246,247,248,249,250,251,252,253,34,9,35,37,17,18,19,20,21,22 . Below ground drain lines for downspouts are old and I am unable to determine if drains will function properly. . . Ground drain lines needs extending and bury below surface. . . Exposed drainline under deck needs extending to drain water away from deck to prevent dampness. . . No gutters or drain lines. . . NA, exterior, 2 CONDITION OF SOFFIT, FASCIA, TRIM AND EAVES Q, S, J, F, G, K, V, 2 Same method as siding. On exposed eave, the perimeter edge of first roof board and where a chimney cuts roof- line should be closely examined. See Discoveries and Comments. . *SOFFIT/PANEL* at eave on *LOCATION* *PROBLEM*. *RECOMMEND*. . PROBLEM=29,259,31,28,30,260,131,261 LOCATION=245,32,33,7,8,34,9,35,37,11,12,13,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 RECOMMEND=262 SOFFIT/PANEL=263,264,265,266,267,268,269,270 . Paint failing on eave. Needs prep and paint at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,271,37,11,12,13,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Barge rafter deteriorated at *LOCATION* . Needs repair or replace. . LOCATION=32,33,7,8,34,9,35,37,11,12,13,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Exposed eave needs primer and paint at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,37,11,12,13,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Also a gap between fascia and roof sheathing exists which allows insects or bees to enter attic. . . NA, exterior, 2 CONDITION OF EXTERIOR WALL COVERINGS, FLASHING Q, J, F, G, K, V, 2 Circle the house slowly paying special attention behind shrubs or hard to reach areas. Check for loose or lifted nails, deterioration, paint peel, caulking at seams, joints, trim, along top of garage door and window brick mold. Swelling of composite siding with recessed nails, green alga areas. Ground clearance six inches or better where possible recommended. See Discoveries and Comments. . *MATERIAL* at *LOCATION* *PROBLEM*. . PROBLEM=28,131,29,272,30,31,273,274,275,276,277,278,279,280 MATERIAL=281,189,190,192,193,195,196,197,198,199,200,201,202,203,204,205,206,207,282,191,283 LOCATION=284,32,33,7,8,34,9,35,37,11,12,13,14,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,285,286,6,19,20,21,22 . Paint failing on siding. Needs prep and paint at *LOCATION*. . LOCATION=287,32,33,7,8,34,9,35,37,11,12,13,14,38,15,16,104,105,6,19,20,21,22 . Siding deteriorated on bottom edge along *LOCATION*. Needs repair or replace as necessary. . LOCATION=32,33,7,8,34,9,35,37,11,12,13,14,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Siding in contact with ground at *LOCATION*. Recommend a ground clearance of six to eight inches where possible. . LOCATION=32,33,7,8,34,9,35,37,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Siding is failing at nail heads and end cuts. Water absorption present. Blisters and deterioration observed. Areas are *LOCATION*. Recommend repair or replace as necessary. . LOCATION=176,32,33,7,8,34,9,35,37,11,12,13,14,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Hole in siding needs closing off with sealant or liquid foam at *LOCATION* where compressor lines enter home. . LOCATION=32,33,7,8,34,9,35,37,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Bare wood needs primer and paint at *LOCATION*. . LOCATION=32,33,7,8,34,9,35,37,11,12,13,14,38,15,16,17,18,104,105,106,107,246,247,248,249,250,251,6,19,20,21,22 . Siding on home is "EIFS" (Exterior Insulation and Finish Systems) or usually called "Synthetic Stucco." We did not perform a test for possible water intrusion, as this is a separate test and contract. . . NA, exterior, 2 FOUNDATION WALLS AND MORTAR JOINTS (exterior) F, K, 4 Circle the house again paying attention to cracks (Hairline cracks are usually typical). Loose stucco, brick mortar, failing paint (Good time to check outside water faucets, (record them at plumbing category). Also observe any underground oil tank locations, Gas meter, Propane tank and lines. See Discoveries and Comments. . *MASONRY* at *LOCATION* *PROBLEM* and needs repair. . PROBLEM=208,31,30,210,211,209,28,29 MASONRY=181,288,289,290,291,292,293 LOCATION=32,33,7,8,9,37,16,104,105,246,247,248,249,250,251,6,19,20,21,22,294 . Brick mortar becomes loose with finger pressure and needs to be scraped and tooled in with new mortar where loose. . . Hole in foundation wall needs closing off with sealant or liquid foam where compressor lines enter home at *LOCATION*. . LOCATION=32,33,7,8,9,37,16,104,105,246,247,248,249,250,251,6,19,20,21,22 . Foundation wall does not have proper footing at *LOCATION*. . LOCATION=32,33,7,8,9,37,16,104,105,246,247,248,249,250,251,6,295,19,20,21,22 . The home needs proper underpinning or permanent foundation to protect and insulate at *LOCATION*. . LOCATION=32,33,7,8,37,16,104,105,246,247,248,249,250,251,287,6,19,20,21,22 . Hairline settlement crack (typical) at *LOCATION*. . LOCATION=32,33,7,8,9,37,16,104,105,246,247,248,249,250,251,6,19,20,21,22 . Wood under-pinning in contact with ground at *LOCATION*. This can cause deterioration and attract wood eating insects. . LOCATION=32,33,7,8,37,16,104,105,246,247,248,249,250,251,287,6,19,20,21,22 . Structural crack in wall at *LOCATION*. The appearance of settlement crack is large enough for concern. Recommend a "Structural Engineer" to inspect. . LOCATION=32,33,7,8,37,16,104,105,246,247,248,249,250,251,287,6,19,20,21,22 . Foundation walls was not "treated" with two coats of cement and sealer (Thoroseal or equal), or foundation coating was not applied. . . NA, exterior, 2 IS OUTSIDE ACCESS TO BASEMENT RODENT PROOF 0, Q, F, G, K, V, 2 Make sure that door fits properly and is properly painted. Look at the ground in front of door for negative slope that may allow water intrusion. Always check the basement or crawlspace last (after you run water at all fixtures inside) to find leaks. When you do enter crawl, look at each inside wall left and right of entry for water or mud marks on wall. If basement entry is below grade with steps, check to see if a floor drain exists and does it appear to work properly. Check to see if door is delaminating on bottom or deteriorated. See Discoveries and Comments. . *CHOOSE_DOOR* *PROBLEM* *RECOMMEND*. . PROBLEM=296,297,298,299,300,301,302,303,304,305,306,307,308,309,310,311,312 CHOOSE_DOOR=313,314,315 RECOMMEND=316,317,318,319,320,321,322 . Access is closed off with a board and prop. Recommend installing a proper size door and hardware. . . Entry door does not fit properly, and needs adjustment. . . Entry door has swollen and deteriorated. (Recommend replacing) . . Glass pane in entry door is *PROBLEM*. . PROBLEM=30,323,324,325,326,327 . Bare wood needs primer and paint, or it can warp or deteriorate. . . NA, exterior, 3 WHAT IS THE CONDITION OF PORCH OR PATIO 0, H, C, I, G, J, N, P, M, W, Y Inspect slowly paying attention to ceiling, walls, floors and supports. Inspect column(s) 360 degrees for deteriora