Date: 12/19/2007 | Time: | Report ID: Sam 1 |
Property: 333 Wild Rasberry Lane Anywhere Vt |
Customer: Sample Buyer |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building. Not Present items will be noted only in the Report and will NOT be in the Summary. Please read the entire report and consider items or components that are not present.
Repair = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Investigate = refers to a system or component that needs additional investigation by a specialist to determine if repairs are needed.
In Attendance: Customer and their agent | Type of building: Single Family (1 story) | Approximate age of building: Over 25 Years |
Temperature: Over 65 | Weather: Clear | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Water Test: No | Radon Test: No |
Foundation: Masonry block | Method used to observe Crawlspace: Crawled | Floor Structure: 2 X 8 2 X 10 Wood joists |
Wall Structure: Wood Masonry | Columns or Piers: Masonry block Supporting walls | Ceiling Structure: 2X4 |
Roof Structure: Engineered wood trusses 2 X 4 Rafters Plywood | Roof-Type: Gable | Method used to observe attic: Walked |
Attic info: Scuttle hole |
Items
|
1.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Inspected | ||||
![]() |
(1) White efflorescence (powder substance) on block wall indicates moisture is in contact with the masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the block if necessary. Efflorescence is found on many homes without water intrusion occurring inside the home. But, it should alert you to the possibility that future steps may be needed. | ||||
![]() |
(2)
Water signs on cedar wall and trim. Also a mold like substance on carpet
at lower level and under stairs. I did not inspect or test for mold and I am
unable to determine if water intrusion occurs.
| ||||
![]() |
(3)
Visible signs of water intrusion in the crawlspace (along front of home) are
present from dampness along the block wall. I am unable to determine the
extent of intrusion or how often it occurs. Cross ventilation may help as
the crawls has no ventilation. I recommend further investigation or
correction by a qualified licensed contractor or water infiltration specialist.
Refer to the diagram as a guide if a drainage system is needed.
|
1.1 | WALLS (Structural) Comments: Inspected | ||
![]() |
There is a horizontal crack(s) in the foundation wall at the left side (facing
front). These cracks do not appear significant to require repairs at this
time. This is my opinion and you should seek a second opinion by a
qualified person.
|
1.2 | COLUMNS OR PIERS Comments: Inspected |
1.3 | FLOORS (Structural) Comments: Inspected |
1.4 | CEILINGS (structural) Comments: Inspected |
1.5 | ROOF STRUCTURE AND ATTIC Comments: Inspected | ||
![]() |
Leak signs in attic perhaps or likely from the old roof as this newer roof
appears in tact. I am unable to determine if leak exists due to no recent
rain.
|
Siding Style: RB&B (Reverse board and batten) | Siding Material: Wood | Exterior Entry Doors: Wood |
Appurtenance: Deck with steps Covered porch | Driveway: Concrete | Garage Door Type: Two automatic |
Garage Door Material: Compressed board Wood |
Items
|
2.0 | WALL CLADDING FLASHING AND TRIM Comments: Inspected | |
Periodical maintenance caulking needed and recommended to keep water
from weeping under siding at concrete shelf. FYI
|
2.1 | DOORS (Exterior) Comments: Inspected | |
![]() |
Patio doors at rear of home are cloudy or seal is broken. Glass panes that
have lost their seal (cloudy) can usually be replaced without replacing the
entire unit. A qualified contractor should inspect and repair as needed.
|
2.2 | WINDOWS Comments: Inspected | |
![]() |
The trim stop for fixed pane is weathered and indicates that water
may be getting below trim. I recommend a paintable sealant be
applied and paint trim.
|
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Comments: Inspected | ||
![]() |
(1)
The step tread on steps on the deck at the rear of home are deteriorated. A
repair or replacement is needed. A skilled masonry contractor should
perform the work.
A handrail may be needed
| ||
![]() |
(2)
The 2x6 decking on the deck at the rear of home has several boards that
are deteriorated. A general replacement is likely. A qualified contractor
should determine whether a repair or replacement is needed.
|
2.4 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) Comments: Inspected | |
![]() |
The concrete drive at the front of home is is pitted in areas and has
settlement cracks. Further deterioration can occur if not repaired. A
qualified contractor should inspect and repair as needed.
|
2.5 | EAVES, SOFFITS AND FASCIAS Comments: Inspected |
2.6 | OTHER Comments: Inspected | |
![]() |
(1)
Old propane tank in ground and is discontinued. I did not determine if gas
remains in discontinued tank? I recommend further investigation by a
qualified person.
| |
![]() |
(2)
There is an odd configuration in ground under addition in crawlspace.
This may be an old well? I am unable to determine. I recommend a
qualified well drilling company or plumber investigate further to determine
if any further action is needed to correct.
|
2.7 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Comments: Inspected |
![]() |
The automatic openers for two-door garage at the front of home will not
reverse when met with resistance. Doors that will not reverse when met
with resistance can kill a child or pet. A qualified contractor should
inspect and repair as needed. The sensors are in place for garage
door(s) and will reverse the door.
|
Roof Covering: Architectural | Viewed roof covering from: Walked roof | Sky Light(s): One |
Chimney (exterior): Brick |
Items
|
3.0 | ROOF COVERINGS Comments: Inspected | ||
![]() |
(1)
The tree limbs that are in contact with roof or hanging near roof should be
trimmed.
| ||
![]() |
(2)
Shingles loose under eave at front of home, needs adhesive.
|
3.1 | FLASHINGS Comments: Inspected |
3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Inspected |
3.3 | ROOF DRAINAGE SYSTEMS Comments: Inspected | |
![]() |
The gutter needs cleaning of debris at the virtually all areas where gutters
are installed. Gutters that drain poorly or clogged can lead to many costly
problems such as deterioration of fascia, soffit or roof edge. It can also
cause gutters to pull loose and lead to possible water intrusion. A
qualified person should repair or replace as needed.
|
Water Source: Well | Water Filters: Sediment filter (We do not inspect filtration systems) | Plumbing Water Supply (into home): PVC |
Plumbing Water Distribution (inside home): Copper PEX | Washer Drain Size: 2" Diameter | Plumbing Waste: PVC Cast iron |
Water Heater Power Source: Electric | Water Heater Capacity: 40 Gallon (1-2 people) | Manufacturer: A.O. SMITH |
Items
|
4.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS Comments: Inspected | |
![]() |
(1)
The basket strainer had leaked and corrected itself for the time being at
the Kitchen sink. Repairs are needed. A qualified person should repair as
necessary.
| |
![]() |
(2)
The tub drain drains slowly under the hall bath. Repairs are needed. A
qualified person should repair as necessary.
|
4.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Inspected | |
![]() |
(1)
The control knob leaks at the hall bath. Repairs are needed. A qualified
licensed plumber should repair or correct as needed.
| |
![]() |
(2)
Brown deposits are on the plumbing fixtures which indicates a filter may
be needed. Filter in place and appears dirty but I am unable to determine if
you need a different or additional filter. I did not test water for bacteria or
other. I recommend contacting a water filtration company.
| |
![]() |
(3)
I recommend the well head lid
be insulated better before winter. FYI
|
4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected | ||
![]() |
The wiring for the water heater missing romex connector. Electrical issues
are considered a hazard until repaired. I recommend a licensed electrician
correct as necessary.
|
4.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected | |
The main shut off is the yellow knob located in the basement at
the pressure tank. This is for your information.
|
4.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments: Inspected |
4.5 | MAIN FUEL SHUT OFF (Describe Location) Comments: Inspected |
The main fuel shut off is at gas meter outside
|
4.6 | SUMP PUMP Comments: Not Present |
Electrical Service Conductors: Below ground | Panel capacity: 200 AMP | Panel Type: Circuit breakers |
Electric Panel Manufacturer: GENERAL ELECTRIC | Branch wire 15 and 20 AMP: Copper | Wiring Methods: Romex |
Items
|
5.0 | SERVICE ENTRANCE CONDUCTORS Comments: Inspected |
5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Inspected |
5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected |
5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Inspected | ||
![]() |
(1)
The wall switch is broken (unsafe) at the upstairs closet for air handler.
At least two outlets are broken at LR and entry way. Electrical issues
are considered a hazard until repaired. A qualified licensed electrician
should perform repairs that involve wiring.
| ||
![]() |
(2)
Several loose wire ends needs placing inside a box with a cover-plate in the basement at the pressure tank of well. I recommend
repair as needed.
| ||
![]() |
(3)
Wall switch on ceiling in Garage, purpose unknown
|
5.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected |
5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected |
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments: Inspected |
The main panel box is located at the garage. |
5.7 | SMOKE DETECTORS Comments: Inspected |
5.8 | CARBON MONOXIDE DETECTORS Comments: Not Present |
Heat Type: Heat Pump Forced Air (also provides cool air) | Energy Source: Electric | Number of Heat Systems (excluding wood): Two |
Ductwork: Insulated | Filter Type: Disposable | Types of Fireplaces: Conventional |
Operable Fireplaces: One | Number of Woodstoves: None |
Items
|
6.0 | HEATING EQUIPMENT Comments: Inspected |
6.1 | NORMAL OPERATING CONTROLS Comments: Inspected |
6.2 | AUTOMATIC SAFETY CONTROLS Comments: Inspected |
6.3 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected | |||
![]() |
(1)
The washable filter is collapsed and needs replacing at upstairs. The
filter needs replacing with a rigid frame to prevent filter from falling out
of alignment. ( Picture 1 ) The filter in basement ( Picture 2 ) needs
replacement and in crawlspace which is difficult to access due to the
crawlspace ( Picture 3 ). A qualified person should repair or replace as
needed
| |||
![]() |
(2)
The supply duct pipe or main plenum is failing in the crawlspace. Energy
loss is occurring in crawlspace and immediate correction is needed. A
licensed HVAC contractor should service or repair unit.
|
6.4 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected |
6.5 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Comments: Inspected | ||
An active birds nest is currently in chimney. It is recommended to install a
cap or bonnet on chimney this fall.
|
6.6 | SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) Comments: Inspected |
6.7 | GAS/LP FIRELOGS AND FIREPLACES Comments: Not Present |
Cooling Equipment Type: Heat Pump Forced Air (also provides warm air) | Cooling Equipment Energy Source: Electricity | Number of AC Only Units: Two |
Items
|
7.0 | COOLING AND AIR HANDLER EQUIPMENT Comments: Inspected |
7.1 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected |
7.2 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected |
7.3 | NORMAL OPERATING CONTROLS Comments: Inspected |
![]() | ![]() |
![]() | ![]() |
![]() |
Ceiling Materials: Sheetrock | Wall Material: Sheetrock | Floor Covering(s): Carpet Hardwood T&G Tile Vinyl |
Interior Doors: Hollow core | Window Types: Double-hung Casement | Cabinetry: Wood Veneer |
Countertop: Composite |
Items
|
8.0 | CEILINGS Comments: Inspected |
8.1 | WALLS Comments: Inspected | |
![]() |
The tissue holder on the wall is damaged at the master bath. I recommend
repair as necessary.
|
8.2 | FLOORS Comments: Inspected | ||
![]() |
(1)
The Baseboard is missing at the upstairs (right of hall bath). Repairs are
needed. A qualified contractor should inspect and repair as needed.
| ||
![]() |
(2)
Tile at shower pan and wall surround are loose and missing mortar or
grout and sealer at the upstairs bath. Repairs are needed to prevent water
damage to shower/bath. A qualified person should repair or replace as
needed.
|
8.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected |
8.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected |
8.5 | DOORS (REPRESENTATIVE NUMBER) Comments: Inspected |
8.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments: Inspected |
![]() |
Four windows will not operate properly and may involve
repair to linkage of crank handles and one cloudy (lost seal) at
the upstairs Bedroom (right of hall bath) and room left of hall
bath and at washer dryer off kitchen. A qualified contractor
should inspect and repair as needed.
|
Attic Insulation: Fiberglass R-19 | Ventilation: Gable vents Soffit Vents | Exhaust Fans: Fan |
Dryer Power Source: 220 Electric | Dryer Vent: Flexible Vinyl | Floor System Insulation: Unfaced R-19 |
Items
|
9.0 | INSULATION IN ATTIC Comments: Inspected |
9.1 | INSULATION UNDER FLOOR SYSTEM Comments: Inspected |
9.2 | VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) Comments: Inspected |
9.3 | VENTILATION OF ATTIC AND FOUNDATION AREAS Comments: Inspected |
See Foundation notes |
9.4 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Inspected | ||
![]() |
The Exhaust fan does not vent to outside at the hall bath and
master bath. Vent pipes should terminate outside and not in the
attic. Many homes have their vent pipe poised at the roof vent
such as yours. It is up to you to determine whether or not this
is a concern or needs further consideration from a general
contractor. A qualified contractor should inspect and repair as
needed.
|
9.5 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) Comments: Inspected | ||
![]() |
Wall switch for room fan in wall has been removed. It is inoperable.
|
Dishwasher Brand: KENMORE | Disposer Brand: IN SINK ERATOR | Exhaust/Range hood: JENN AIR |
Range/Oven: JENN AIR | Built in Microwave: KENMORE |
Items
|
10.0 | DISHWASHER Comments: Inspected |
10.1 | RANGES/OVENS/COOKTOPS Comments: Inspected |
10.2 | RANGE HOOD Comments: Inspected |
10.3 | TRASH COMPACTOR Comments: Not Present |
10.4 | FOOD WASTE DISPOSER Comments: Inspected |
10.5 | MICROWAVE COOKING EQUIPMENT Comments: Inspected |
serving All of Vermont
(802) 503-3884
Customer
Sample Buyer
Address
333 Wild Rasberry Lane
Anywhere Vt
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||
|
![]() |
|||||||||||||||||||||
|
![]() |
|||||||||||||||||||||||||||||||||
|
![]() |
||||||||||||
|
![]() |
||||||||||||
|
![]() |
||||||||||||||||||||||||||||||
|
![]() |
||||||||||||||||||
|
serving All of Vermont
(802) 503-3884
Customer
Sample Buyer
Address
333 Wild Rasberry Lane
Anywhere Vt
![]() |
|||||||||||||||||||||||||||||||||
|
![]() |
||||||||||||
|
![]() |
|||||||||
|
![]() |
|||||||||
|
INVOICE |
CheckPoint Property Inspection
serving All of Vermont (802) 503-3884 Inspected By: Joby McDonald |
Inspection Date: 12/19/2007
Report ID: Sam 1 |
Customer Info: | Inspection Property: |
Sample Buyer
Customer's Real Estate Professional: |
333 Wild Rasberry Lane Anywhere Vt |
| ||||||||
Tax $0.00 | ||||||||
Total Price $250.00 |
Payment Method:
Payment Status:
Note:
This inspection was performed in accordance with and under the terms of a Pre-Inspection Agreement. The agreement was signed and agreed upon before the preparation of this report and a signed copy of the agreement is available upon request. An unsigned copy of the agreement may be attached to this report for your information or it may also be available on the company web site.