Property Address:
777 Lucky Lane
Grinnell IA 50112
Roy Wier
450 Hwy 1 W #140
Iowa City, IA 52246
319-899-7538
Date: 10/1/2020 | Time: 12:30:00 PM | Report ID: 77777 |
Property: 777 Lucky Lane Grinnell IA 50112 |
Customer: Nacho Villa |
Real Estate Professional: Phil Dunphy |
Comment Key or Definitions
The following are definitions of comment descriptions in this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Age Of Home: Over 25 Years | Client Is Present: Yes | Weather: Clear |
Temperature: Below 65 | Rain in last 3 days: Yes |
450 Hwy 1 W #140
Iowa City, IA 52246
319-899-7538
Customer
Nacho Villa
Address
777 Lucky Lane
Grinnell IA 50112
1.0 | Roof Covering | |
Repair or Replace | ||
1.1 | Gutters and Downspouts | |
Repair or Replace | ||
Multiple downspouts are missing extensions. Recommend this be corrected.
![]() 1.1 Item 1(Picture)
![]() 1.1 Item 2(Picture)
|
1.2 | Vents, Skylights, Chimney, and other roof penetrations | |
Repair or Replace | ||
Failed sealant where roof covering stops on chimney. Recommend replacement with an appropriate high-temp rated sealant.
![]() 1.2 Item 1(Picture)
|
2.0 | Wall Covering, Flashing and Trim | |
Repair or Replace | ||
(1) Trim/siding is deteriorated in areas (including several places on trim around screens at screened in deck).
Failed sealant noted where metal trim along front of 2nd floor meets wood corner trim. Repair as needed by a qualified contractor. Note: Black spot near top of wall on wood trim at front corner of home is discolored sealant in a knot hole. This is for your information. ![]() 2.0 Item 1(Picture)
![]() 2.0 Item 2(Picture)
![]() 2.0 Item 3(Picture)
![]() 2.0 Item 4(Picture) inside lawn shed on rear of garage.
![]() 2.0 Item 5(Picture)
![]() 2.0 Item 6(Picture)
![]() 2.0 Item 7(Picture)
|
||
(2) Most of the deteriorated spots throughout the field of the wood siding have been touched up/ patched with caulk/sealant. Ongoing maintenance
repairs will be needed until/unless a lower maintenance siding is installed.
![]() 2.0 Item 8(Picture)
![]() 2.0 Item 9(Picture)
![]() 2.0 Item 10(Picture)
![]() 2.0 Item 11(Picture)
![]() 2.0 Item 12(Picture)
![]() 2.0 Item 13(Picture)
![]() 2.0 Item 14(Picture)
|
2.1 | All Exterior Doors | |
Repair or Replace | ||
Fogging glass as a result of failed thermal seals was observed in multiple sliding doors. Others may show in different lighting or temperature
conditions.
Sliding rear door in main floor office (rear room adjacent to bathroom) rubs on the jamb. The (2) sliding doors closest to the front entry, in the main floor living room, were not accessible for testing at the time of inspection. Repair as needed by a qualified contractor. ![]() 2.1 Item 1(Picture)
![]() 2.1 Item 2(Picture)
![]() 2.1 Item 3(Picture)
![]() 2.1 Item 4(Picture)
![]() 2.1 Item 5(Picture)
|
2.2 | Adjacent Walkways and Driveways | |
Repair or Replace | ||
Cracks/settling noted at city sidewalk. Repair as needed.
![]() 2.2 Item 1(Picture)
|
2.3 | Stairs, Steps, Stoops, Stairways and Ramps | |
Repair or Replace | ||
Steps at screened deck have settled and are sloping downhill. Recommend this be corrected.
![]() 2.3 Item 1(Picture)
|
2.4 | Porches, Patios, Decks, Balconies and Carports | |
Repair or Replace | ||
Recommend eliminating small platform (birdfeeder access?) outside screened deck , for safety.
Skirting below screened deck is damaged/deteriorated in areas. Deck boards are deteriorated/damaged in areas at rear deck and rear balcony. Repair as needed by a qualified contractor. ![]() 2.4 Item 1(Picture)
![]() 2.4 Item 2(Picture)
![]() 2.4 Item 3(Picture)
![]() 2.4 Item 4(Picture)
![]() 2.4 Item 5(Picture)
|
2.5 | Railings, Guards and Handrails | |
Repair or Replace | ||
Balusters spaced a maximum of 4" apart (current standard) are missing at all exterior balconies (safety item).
Deterioration noted at end of railing at rear deck. Railing at screened deck is shorter than the current recommended minimum height of 36". This railing is deteriorated in one or more places (noted where it abuts the siding on the front side). Screen is allowable en lieu of balusters/proper guards if the material is properly installed and rated for this application (the intent of the applicable standards is to ensure that the product provides fall protection to the same extent that a compliant railing would). This mesh/screen is loose/damaged in areas. Repair as needed by a qualified contractor. ![]() 2.5 Item 1(Picture)
![]() 2.5 Item 2(Picture)
![]() 2.5 Item 3(Picture)
![]() 2.5 Item 4(Picture)
![]() 2.5 Item 5(Picture)
![]() 2.5 Item 6(Picture)
![]() 2.5 Item 7(Picture)
|
2.7 | Windows | |
Repair or Replace | ||
Fogging glass as a result of failed window seals was observed in multiple windows. Others may show in different lighting or temperature conditions.
Recommend further evaluation of all of the windows.
Basement window closest to front entry would not open at the time if inspection. Repair as needed by a qualified contractor. ![]() 2.7 Item 1(Picture)
![]() 2.7 Item 2(Picture)
|
4.0 | Heating System | |
Repair or Replace | ||
No serial number or data label found on furnace. Unit is most likely (and per seller) original to the home (1970). Typical lifespan is 25-30 years.
Rust visible inside heat exchangers. Rust/corrosion also visible lower furnace cabinet. Recommend having unit cleaned and serviced by a qualified
HVAC contractor, and further recommend budgeting for replacement due to age.
![]() 4.0 Item 1(Picture)
![]() 4.0 Item 2(Picture)
![]() 4.0 Item 3(Picture)
![]() 4.0 Item 4(Picture)
![]() 4.0 Item 5(Picture)
![]() 4.0 Item 6(Picture)
|
4.4 | Presence of installed heat source in each room | |
Repair or Replace | ||
No heat registers found in crawlspace nor in furnace room. Register in laundry room has been blocked off. Recommend this be corrected for
improved energy efficiency (all areas within the building envelope maintaining a constant temperature is most efficient).
|
4.6 | Cooling System | |
Not Inspected | ||
Unable to decipher serial number. Unit is 40+ years old. Typical lifespan is 15-20 years. The condenser outside (AC unit) is old and may last a few
years more, but may not. I have seen units fail shortly after a home inspection during the seasonal change from mild to hot weather. I cannot
determine how long your AC will last before a replacement is necessary. Recommend budgeting for replacement, given the age of the unit.
The A/C was not able to be safely tested for proper operation due to the outside air temperature being 65 degrees or less. We did not operate the AC unit(s). ![]() 4.6 Item 1(Picture) serial number
![]() 4.6 Item 2(Picture)
![]() 4.6 Item 3(Picture)
|
5.0 | Main Water supply shut-off valve (Describe location) | |
Repair or Replace | ||
The main shut off is the blue lever located beside the water heater. Slow leak noted at this valve. Repair/replace as needed, by a qualified plumber.
![]() 5.0 Item 1(Picture)
|
5.2 | Water Heating Equipment, Controls, Chimneys, Flues and Vents | |
Repair or Replace | ||
Charred deposits and orange flame (indicating improper and/or inefficient combustion) noted at burner area of water heater. Recommend further
evaluation and maintenance/service as needed by a qualified plumber.
Mfd. 1998. Typical lifespan is 6-12 years. This unit has surpassed the normal life expectancy. We have seen older units still functioning properly,
and we have seen newer units fail. The water heater is a disposable part of the home. Recommend budgeting for replacement. Lifespan may be
extended with annual maintenance. ![]() 5.2 Item 1(Picture)
![]() 5.2 Item 2(Picture)
![]() 5.2 Item 3(Picture)
|
5.3 | Interior Water Supply, Fixtures, Faucets and Systems | |
Repair or Replace | ||
Failed sealant where tile surround meets tub in 2nd floor bathroom. Recommend removal and replacement of old sealant as a maintenance item.
Small leak from valve on left in 2nd floor shower. Recommend this be corrected by a qualified plumber. ![]() 5.3 Item 1(Picture)
![]() 5.3 Item 2(Picture)
![]() 5.3 Item 3(Picture)
|
5.6 | Interior Fuel Storage, Piping, Venting, Supports, Leaks | |
Repair or Replace | ||
No bond wire found at gas piping to protect CSST against lighting damage. Recommend this be corrected for safety. See CSSTSafety.com for
more info.
![]() 5.6 Item 1(Picture)
|
6.1 | Electric Meter and Base, Main Disconnect, Main and Distribution Panels, Grounding | |
Repair or Replace | ||
Multiple double tapped circuits noted at main electric panel. Recommend this be corrected by a qualified electrician for safety.
![]() 6.1 Item 1(Picture)
![]() 6.1 Item 2(Picture)
|
6.2 | Circuit Breakers, Fuses and Compatibility of their Amperage and Voltage | |
Repair or Replace | ||
One circuit breaker in main panel is of a different brand than panel manufacturer, which is not permitted by the manufacturer. Recommend further
evaluation and repair as needed by a qualified electrician for safety.
![]() 6.2 Item 1(Picture)
|
6.3 | Switches, Receptacles, Light Fixtures and Visible Wiring (observed from a representative number) | |
Repair or Replace | ||
Outlet on front wall in basement (below window closest to front entry) tested as having reversed polarity. Recommend this be corrected by a
qualified electrician for safety.
![]() 6.3 Item 1(Picture)
|
6.4 | All Ground Fault Circuit Interrupter Receptacles | |
Repair or Replace | ||
(1) GFCI outlet at permanent ladder outside did not trip when tested (malfunctioning). Recommend this be corrected by a qualified electrician for
safety.
![]() 6.4 Item 1(Picture)
|
||
(2) Kitchen, bathroom, garage, unfinished basement, laundry, and the exterior outlets in use as power supply for heat tape in gutters, have not yet been upgraded to GFCI for safety. Recommend upgrading.
![]() 6.4 Item 2(Picture)
![]() 6.4 Item 3(Picture)
![]() 6.4 Item 4(Picture)
![]() 6.4 Item 5(Picture)
|
6.6 | Smoke Alarms | |
Repair or Replace | ||
Smoke alarms are missing at multiple recommended locations. Smoke alarms present are aged (over 10 years old). Updating is recommended
every 10 years as a safety/maintenance item. See infographic for placement. When replacing, install photoelectric smoke alarms. Do not use
ionization-only smoke alarms.
![]() 6.6 Item 1(Picture) infographic
|
6.7 | Carbon Monoxide Alarm | |
Not Present, Repair or Replace | ||
There is no carbon monoxide alarm found in home. It is recommended that one be installed per floor according to the manufacturer's instructions.
|
8.2 | Venting systems (Kitchens, Baths and Laundry) | |
Repair or Replace | ||
Multiple turns in dryer duct. Recommend cleaning as often as is needed to keep the line clean/clear (once a year minimum). Recommend
eliminating sock lint trap/heat recovery (introducing excess humidity into the home is not advisable). This is considered a maintenance item.
![]() 8.2 Item 1(Picture)
![]() 8.2 Item 2(Picture)
|
8.3 | Insulation Under Floor System | |
Not Present, Repair or Replace | ||
Insulation is missing at some or all joist spaces at perimeter of basement above foundation wall. This can be a significant source of energy loss.
Recommend this be corrected. Rebates may be available from the energy provider.
![]() 8.3 Item 1(Picture)
|
9.3 | Stairs, Steps, Landings, Stairways and Ramps and Railings, Guards and Handrails | |
Repair or Replace | ||
Recommend upgrading interior railings such that a 4" sphere will not pass through / under them, for child safety.
![]() 9.3 Item 1(Picture)
![]() 9.3 Item 2(Picture)
|
9.5 | Doors (representative number) | |
Repair or Replace | ||
Door at main floor bathroom hits glass at shower. Recommend adjustment of existing hinge mounted door stop or some other remedy to prevent
damage to this glass.
Door binds at jamb when closing at main floor bedroom closest to kitchen. Door to main floor office/library bind on carpet (needs cut down unless height of flooring changes). Repair as needed. ![]() 9.5 Item 1(Picture)
![]() 9.5 Item 2(Picture)
![]() 9.5 Item 3(Picture)
|
10.0 | Garage Door (s) | |
Repair or Replace | ||
Exterior surface of overhead door is deteriorated. Interior surface of door is stained in areas. Weather seal around door is damaged. Repair or
replace as needed. Note: It may be possible to replace the exterior surface of the door.
![]() 10.0 Item 1(Picture)
![]() 10.0 Item 2(Picture)
![]() 10.0 Item 3(Picture)
![]() 10.0 Item 4(Picture)
![]() 10.0 Item 5(Picture)
|
10.1 | Garage Door Operators (Report whether or not doors will reverse when met with resistance) | |
Repair or Replace | ||
The garage door did not reverse when met with resistance. Recommend this be corrected for safety. This is typically an adjustment at the operator.
The sensors are in place for garage door(s) and will reverse the door. ![]() 10.1 Item 1(Picture)
|
11.0 | Dishwasher | |
Repair or Replace | ||
The dishwasher drain did not have a proper high loop to prevent backflow of water into the dishwasher. Recommend the dishwasher drain hose be raised
with an appropriate bracket to correct this.
![]() 11.0 Item 1(Picture) high_loop
![]() 11.0 Item 2(Picture)
|
The inspector is not required to: Walk on any roof surface, predict the service life expectancy, inspect underground downspout diverter drainage pipes, remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces, move insulation, inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. Walk on any roof areas that appear, in the opinion of the inspector to be unsafe, and or cause damage. Perform a water test, warrant or certify the roof. Confirm proper fastening or installation of any roof material.
|
Styles & Materials
Roof Covering type: Modified bitumen Viewed roof covering from: Walked roof Chimney (exterior): N/A Roof Structure: Not visible Attic info: none |
Recommend cleaning leaves/debris off roof as a maintenance item.
No attic at 2nd floor. This is for your information.
The inspector is not required to: Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting, Inspect items, including window and door flashings, which are not visible or readily accessible from the ground, Inspect geological, geotechnical, hydrological and/or soil conditions, Inspect recreational facilities, playground equipment. Inspect seawalls, break-walls and docks, Inspect erosion control and earth stabilization measures, Inspect for safety type glass, Inspect underground utilities, Inspect underground items, Inspect wells or springs, Inspect solar, wind or geothermal systems, Inspect swimming pools or spas, Inspect wastewater treatment systems septic systems or cesspools, Inspect irrigation or sprinkler systems, Inspect drain fields or drywells, Determine the integrity of multi-pane window glazing or the thermal window seals.
|
Styles & Materials
Siding Material: Wood Appurtenance: Deck with steps Deck Balcony Driveway: Asphalt |
Failed sealant noted where metal trim along front of 2nd floor meets wood corner trim.
Repair as needed by a qualified contractor.
Note: Black spot near top of wall on wood trim at front corner of home is discolored sealant in a knot hole. This is for your information.
Sliding rear door in main floor office (rear room adjacent to bathroom) rubs on the jamb.
The (2) sliding doors closest to the front entry, in the main floor living room, were not accessible for testing at the time of inspection.
Repair as needed by a qualified contractor.
Skirting below screened deck is damaged/deteriorated in areas.
Deck boards are deteriorated/damaged in areas at rear deck and rear balcony.
Repair as needed by a qualified contractor.
Deterioration noted at end of railing at rear deck.
Railing at screened deck is shorter than the current recommended minimum height of 36". This railing is deteriorated in one or more places (noted where it abuts the siding on the front side). Screen is allowable en lieu of balusters/proper guards if the material is properly installed and rated for this application (the intent of the applicable standards is to ensure that the product provides fall protection to the same extent that a compliant railing would). This mesh/screen is loose/damaged in areas.
Repair as needed by a qualified contractor.
Basement window closest to front entry would not open at the time if inspection. Repair as needed by a qualified contractor.
The inspector is not required to: Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector, Move stored items or debris, Operate sump pumps with inaccessible floats, Identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems, Provide any engineering or architectural service, Report on the adequacy of any structural system or component.
|
Styles & Materials
Foundation: Poured concrete |
The inspector is not required to: Inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating systems, solar heating systems or fuel tanks. Inspect underground fuel tanks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. Light or ignite pilot flames. Activate heating, heat pump systems, or other heating systems when ambient temperatures or when other circumstances are not conducive to safe operation or may damage the equipment. Override electronic thermostats. Evaluate fuel quality. Verify thermostat calibration, heat anticipation or automatic setbacks, timers, programs or clocks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. Inspect window units, through-wall units, or electronic air filters. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks. Examine electrical current, coolant fluids or gasses, or coolant leakage.
|
Styles & Materials
Heat Type: Forced Air Energy Source: Gas Cooling Equipment Type: Air conditioner unit Filter Type: Disposable |
Your (2) air filters are 14 x 25 x 1. This is for your information.
The inspector is not required to: Light or ignite pilot flames. Determine the size, temperature, age, life expectancy or adequacy of the water heater. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler systems. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. Determine the water quality or potability or the reliability of the water supply or source. Open sealed plumbing access panels. Inspect clothes washing machines or their connections. Operate any main, branch or fixture valve. Test shower pans, tub and shower surrounds or enclosures for leakage. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. Determine whether there are sufficient clean-outs for effective cleaning of drains. Evaluate gas, liquid propane or oil storage tanks. Inspect any private sewage waste disposal system or component of. Inspect water treatment systems or water filters. Inspect water storage tanks, pressure pumps or bladder tanks. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. Evaluate or determine the adequacy of combustion air. Test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief valves. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.
|
Styles & Materials
Water Source: Public Water Filters: None Plumbing Water Supply (into home): Copper Plumbing Waste: PVC Cast iron Copper Water Heater Power Source: Gas (quick recovery) Water Heater Capacity: 40 Gallon (1-2 people) Water Heater Location: Basement |
Mfd. 1998. Typical lifespan is 6-12 years. This unit has surpassed the normal life expectancy. We have seen older units still functioning properly, and we have seen newer units fail. The water heater is a disposable part of the home. Recommend budgeting for replacement. Lifespan may be extended with annual maintenance.
Small leak from valve on left in 2nd floor shower. Recommend this be corrected by a qualified plumber.
The inspector is not required to: Insert any tool, probe or device into the main panel, sub-panels, downstream panel, or electrical fixtures. Operate electrical systems that are shut down. Remove panel covers or dead front covers if not readily accessible. Operate over current protection devices. Operate non-accessible smoke detectors. Measure or determine the amperage or voltage of the main service if not visibly labeled. Inspect the alarm system and components. Inspect the ancillary wiring or remote control devices. Activate any electrical systems or branch circuits which are not energized. Operate overload devices. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices. Verify the continuity of the connected service ground. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. Inspect spark or lightning arrestors. Conduct voltage drop calculations. Determine the accuracy of breaker labeling. Inspect exterior lighting.
|
Styles & Materials
Electrical Service Conductors: Below ground Panel Type: Circuit breakers Panel capacity: 200 AMP Electric Panel Manufacturer: GENERAL ELECTRIC Branch wire 15 and 20 AMP: Copper Wiring Methods: Romex |
The inspector is not required to: Inspect the flue or vent system. Inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep. Operate gas fireplace inserts. Light pilot flames. Determine the appropriateness of such installation. Inspect automatic fuel feed devices. Inspect combustion and/or make-up air devices. Inspect heat distribution assists whether gravity controlled or fan assisted. Ignite or extinguish fires. Determine draft characteristics. Move fireplace inserts, stoves, or firebox contents. Determine adequacy of draft, perform a smoke test or dismantle or remove any component. Perform an NFPA inspection. Perform a Phase 1 fireplace and chimney inspection.
|
Styles & Materials
Types of Fireplaces: Vented gas logs Operable Fireplaces: One |
|
Styles & Materials
Attic Insulation: Unknown Ventilation: None found Dryer Power Source: 220 Electric Dryer Vent: Metal |
The inspector shall: Open and close a representative number of doors and windows. Inspect the walls, ceilings, steps, stairways, and railings. Inspect garage doors and garage door openers by operating first by remote (if available) and then by the installed automatic door control. And report as in need of repair any installed electronic sensors that are not operable or not installed at proper heights above the garage door. And report as in need of repair any door locks or side ropes that have not been removed or disabled when garage door opener is in use. And report as in need of repair any windows that are obviously fogged or display other evidence of broken seals.
The inspector is not required to: Inspect paint, wallpaper, window treatments or finish treatments. Inspect central vacuum systems. Inspect safety glazing. Inspect security systems or components. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or firewall compromises. Move furniture, stored items, or any coverings like carpets or rugs in order to inspect the concealed floor structure. Move drop ceiling tiles. Inspect or move any household appliances. Inspect or operate equipment housed in the garage except as otherwise noted. Verify or certify safe operation of any auto reverse or related safety function of a garage door. Operate or evaluate security bar release and opening mechanisms, whether interior or exterior, including compliance with local, state, or federal standards. Operate any system, appliance or component that requires the use of special keys, codes, combinations, or devices. Operate or evaluate self-cleaning oven cycles, tilt guards/latches or signal lights. Inspect microwave ovens or test leakage from microwave ovens. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or other small, ancillary devices. Inspect elevators. Inspect remote controls. Inspect appliances. Inspect items not permanently installed. Examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed pool/spa, recreational equipment or self-contained equipment. Come into contact with any pool or spa water in order to determine the system structure or components. Determine the adequacy of spa jet water force or bubble effect. Determine the structural integrity or leakage of a pool or spa.
|
Door binds at jamb when closing at main floor bedroom closest to kitchen.
Door to main floor office/library bind on carpet (needs cut down unless height of flooring changes).
Repair as needed.
|
|
![]() |
INVOICE |
Vigilant Home Inspections LLC 450 Hwy 1 W #140 Iowa City, IA 52246 319-899-7538 Inspected By: Roy Wier |
Inspection Date:
10/1/2020 Report ID: 77777 |
Customer Info: | Inspection Property: |
Nacho Villa Customer's Real Estate Professional: Phil Dunphy |
777 Lucky Lane Grinnell IA 50112 |
Inspection Fee:
|
||||||||
Tax $0.00 |
||||||||
Total Price $77777.00 |
Payment Method:
Check
Payment Status: Paid At Time Of Inspection
Note: Thank you! Don't keep us a secret!
Recommend cleaning leaves/debris off roof as a maintenance item.