Peach Inspections
Peach Inspections 236 Somewhere Ave, #100, Cityville, PA 19123

 
236 Somewhere Ave
#100
Cityville PA 19123

Report ID: Condominium Sample Report
Date: 3/7/2021
Report Prepared For: Mr. & Mrs Buyer



Top Table of Contents Bottom

Table of Contents


Top Table of Contents Bottom
Client:
Mr. & Mrs Buyer
Date: 3/7/2021 Report ID: Condominium Sample Report
Property:
236 Somewhere Ave
#100
Cityville PA 19123
Client's Agent:

Present at Inspection:
Buyer's Agent, Buyer's Family Member

Approximate age:
12 Years

Structure Style:
Condo/Flat

Temperature:
55 Degrees

Weather:
Overcast

Occupancy Status:
Vacant, Unfurnished

Comment Key or Definitions

All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. For your convenience, the following conventions have been used in this report:

Safety Concern: Denotes an observation, defect or recommendation that is considered an immediate safety concern. Safety standards have increased over the years. The inspector will use today's standards as a baseline to evaluate the home. Safety standards may have changed since your home was built however, it is recommended when ever practical to bring the home up to current standards.

Correction recommended: Denotes a system or component of the home that is deficient or at the end of its service life, and needs corrective action by a professional to assure proper and reliable function. We recommend the professional making any repairs to inspect the property further, in order to discover and repair related problems that were not identified in the report. All evaluations corrections and should be made prior to end of inspection contingency.

Further evaluation recommended: Denotes an observation, defect or recommendation where the full extent of the issue cannot be ascertained in a visual inspection. A more technically exhaustive evaluation or destructive testing may be need to determine the full extent of the issue. All evaluations corrections and should be made prior to end of inspection contingency.

Improvement recommended: Denotes a system or component that should receive normal maintenance, repair, or adjustment in order to continue functioning properly.

This confidential report is prepared exclusively for our client. Not to be interpreted by anyone other than our CLIENT or Representative. The report is NOT transferable.

Top Table of Contents Bottom

1.  Pennsylvania Inspector Compliance Statement

  • I represent that I am a full member in good standing of The American Society of Home Inspectors (ASHI)

  • I will Conduct a home inspection of the previously mentioned property in accordance with the American Society of Home Inspectors code of ethics and the Standards of Practice.

  • I am in compliance with the Pennsylvania Home Inspection Law.

  • I carry all the required insurance.


The American Society of Home Inspectors (ASHI):
ASHI #261399
International Association of Certified Home Inspectors:
InterNACHI #15033120
Certified Pesticide Applicator:
BU13789
Certification #710880
PA DEP Radon:
Firm #2288
Certification #3356
Certified Residential Thermographer:
CRT # 2020042407
North American Deck & Railing Association (NADRA):
Deck Professional - Code Certified

1.0 Inspectors Comments
.
 The home is a condominium. Some of the homes components may be common elements that are maintained by the condominium association. It may also be difficult to determine what common elements are directly associated with this home. All components that are clearly associated with the home and are within the ASHI standards of practice will be inspected and reported on. 

The home buyer is advised to refer to the condominium documents prior to settlement for information regarding shared common building components, the schedule for performing repairs and maintenance on these building components and the associations budget for preforming repairs and maintenance on the building components.    

Top Table of Contents Bottom

2.  Introduction, Scope of the Inspection

PLEASE READ CAREFULLY

INTRODUCTION:
The following numbered and attached pages are your home inspection report. The report includes photographs, comments, and the Standards of Practice. This inspection was performed in accordance
with the current Standards of Practice and Code of Ethics of the American Society of Home Inspectors.  The Standards contain certain and very important limitations, exceptions, and exclusions to the inspection. A copy is available prior to, during, and after the inspection, and it is part of the report. Please find a copy of the ASHI Standards of Practice in the attachment section of the report. All components designated in the ASHI standards of practices, except for limitations that may be noted in the report, will be inspected. The inspection is for the most part a limited visual inspection only. A representative sampling of the building components is viewed in areas that are accessible at the time of the inspection. No destructive testing or dismantling of components is performed. Be sure to keep your signed copy of the home inspection agreement with the report for future reference. Your report will be accessible via the web link you have been sent for five years.

SCOPE:  This inspection complies and reflects with the provision of Act 114, Section 75, known as the PA Home Inspection Law. A home inspection is intended to assist in evaluating the overall condition of the dwelling. The inspection is based on observation of the visible, readily accessible and apparent condition of the structure and its components on this day. The results of this inspection are not intended to make any representation regarding the presence or absence of latent or concealed defects that are not reasonably ascertainable or readily accessible in a competently performed inspection.

NO WARRANTY IS EXPRESSED OR IMPLIED.  It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all defects will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection is not and should not be considered a guarantee, warranty or insurance policy of any kind. The inspection is not a code compliant inspection. This report does not include inspection for mold, lead, asbestos, or wood destroying insects.

The person conducting your inspection is not a licensed structural engineer or other professional whose license authorizes the rendering of an opinion as to the structural integrity of a building or its other component parts.

You are advised to seek two professional opinions and acquire estimates of repair as to any defects, comments, improvements or recommendations mentioned in this report. We recommend that the professional making any repairs inspect the property further, in order to discover and repair related problems that were not identified in the report. We recommend that all repairs or corrections should be completed and documented before the closing or purchase of the property. Feel free to hire other professionals to inspect the property prior to closing, including HVAC professionals, electricians, engineers, or roofers.

Please refer to the pre-inspection agreement and the ASHI Standards of Practice for a full explanation of the scope of the inspection, its limitations and exclusions.

Top Table of Contents Bottom

3.  Roof

Limitations of the Roof inspection:  We Inspected the roof-covering materials, flashings, skylights, chimneys, and roof penetrations if accessible. This inspection is not a guarantee that a roof leak in the future will not happen. Roofs leak. Even a roof that appears to be in good, functional condition may leak under certain circumstances. We will not take responsibility for a roof leak that happens in the future. This is not a warranty or guarantee of the roof system. It is virtually impossible for anyone to detect a leak except as it is occurring or by specific water tests, which are beyond the scope of our inspection service.


Method used to Inspect:
Roof Access From Third Floor
Roof Covering Materials:
EPDM rubber roofing
Number of layers visible:
One layer
Approximate Age:
Undetermined
Average Service Life:
EPDM 20 - 30 years
Gutter Type:
6" K
Gutter Guards:
No
   

3.0 LOW SLOPED ROOF
.
  Note: Low sloped roofs need to be closely monitored and maintained, since their condition can change drastically from one season to the next. Monitoring during periods of rain is recommended. Routine repairs should be expected.
 
The roll roofing material of the low sloped roof appears to be in good shape. I carefully walked upon the roof surface. No soft spots in the roof deck structure were noticed. I inspected the seams of the material in the field and the flashing edges. No open seams. No cracking. No fissures. No signs of major patching. No large areas of erosion. No standing water puddles apparent. There are no obvious indications of imminent roof leaks (as seen from the roof surface). The exact age of the roof covering material is undetermined. No significant deficiencies were observed. No need for immediate major repairs were apparent.
3.1 PLUMBING VENTS
.
 
There is visible flashing installed around the plumbing stacks. No damage. Good.
Top Table of Contents Bottom

4.  Exterior

We inspect siding, flashing and trim, all exterior doors, eaves, soffits, and fascia where accessible from the ground. We inspect attached or adjacent decks, balconies, stoops, steps, porches, and their associated railing. We inspect vegetation, grading, surface drainage, and retaining walls that are likely to adversely affect the building. We inspect adjacent or entryway walkways, patios and driveways.


Exterior Wall Covering Materials:
Brick
Exterior Insulation Finish (EIFS)
   

4.0 DRIVEWAY & PARKING AREA
.
 
The parking area appears functional.
 
Signs of water intrusion in the interior garage were noted. This may be caused by deficiencies with the exterior finishes such as the cracks, improper terminations and improper or insufficient flashing details.
4.1 STUCCO EXTERIOR
.
 The subject building is clad with EIFS (Exterior Insulated Finish Systems).  Buildings clad with EIFS (Exterior Insulation and Finish Systems) a.k.a. synthetic stucco have a very strong tendency to retain moisture between the sheathing of the home and the finish system. The design of EIFS, unlike other systems (brick, stone, siding, etc.), does not allow the moisture to drain out. The problem is water intrusion and entrapment in the wall cavities. The moisture can sit in contact with the sheathing for a prolonged period and rotting may result. Damage can be serious.

While a brick or stone wall will contain an internal drainage plane behind it and weep holes along the bottom edge to allow for water drainage, moisture intruding into the EIFS wall cavities is more damaging because it cannot readily escape back out through the waterproof EIFS exterior as quickly as it can through brick veneer, stone, or cement stucco, leaving the internal sheathing and wood framing vulnerable to rot and decay.

Successful installation of EIFS depends upon keeping water out of the wall cavities.  Consequently, in an effort to keep the water out, an industry-wide installation standard was developed that details installation procedures to be followed.  In conjunction with this, the EIFS manufacturers then trained and certified applicators to install their products and supplied them with materials which met specification standards.
 
Improper termination of the EIFS was observed on the exterior of the building. There were cracks in the EIFS noted on the exterior of the building. The issues with the cracks and improper terminations could allow water intrusion and/or issues related to water intrusion. There also were open gaps observed along the top of the brick veneer on the exterior of the building. This can allow water intrusion behind the brick which could lead to water damage to the building structure. These exterior deficiencies could impact financial responsibilities related to condo association fees. Recommend reviewing condo association documents and/or discuss with association what future plans may be for repairs.
Top Table of Contents Bottom

5.  Heating System

Limitations of the heating system inspection: This inspection of the heating system is a visual inspection only using the normal operating controls for the system. The inspection of the heating system is general and not technically exhaustive. A detailed evaluation of the interior components of the heating system is beyond the scope of a home inspection. It is essential that any recommendation that we make for service, correction, or repair be scheduled before the end of inspection contingency, because the hired-professional could reveal additional defects or recommend further repairs that may affect your evaluation of the property.


Heating Type:
Heat Pump (Provides Cooling as well)
Distribution Method:
Duct Work
Location:
Utility Closet
Approximate Age:
12 years
Average Service Life:
15-20 years
Thermostat(s):
Hallway

5.0 HEATING EQUIPMENT
.
 
The home is heated and cooled with a Heat Pump.
Using the thermostat I turn the heat pump system on.
The system was run in heating mode, emergency heat mode and cooling mode.
The heat pump system appeared to function normally at the time of the inspection.

Heating and air conditioning systems require regular maintenance. There is no visible service tag on the HVAC heating system. I recommend asking the seller for recent service records. If the HVAC system has not been serviced within the last year I recommend having the system cleaned and serviced by an HVAC contractor prior to the end of inspection contingency..
5.1 CONDENSER
.
207 Condenser
 
The condenser for the heat pump is located on the roof of the building.
The condenser unit appears level and was securely mounted on a base.
There is an electrical service disconnect for the condenser unit.
The fins on the condenser appeared clean. No rust or corrosion was noted.
 
IMPROVEMENT RECOMMENDED:  The insulation around the condenser’s suction line (refrigerant line) was in poor condition. The insulation was dry, cracked and pieces were missing (voids). The insulation should be kept in good condition. The suction line should be kept well insulated to prevent energy loss. Recommend having a qualified person install new insulation around suction line.
5.2 HEAT PUMP OPERATION
.
 
The air handler and indoor coil for the heat pump is located in a utility closet. I could hear the fan running. The suction lines that carry the refrigerant to the indoor coil appear to be in good condition and felt warm. There is an electrical heating element in the air handler for back-up heat.  I ran the unit on back-up heat for approximately 15 minutes, the back-up heating element produced heat.
 
The condensation line drains from the unit to an undetermined location No active condensation water leaks observed.  
5.3 AIR FILTER
.
 
At the time of this inspection the air filter for the forced air heating/air conditioner was clean. I recommend that the air filter be changed every month the system is in use. This will prevent dirt from building up on the internal components, and reduce the amount of dirt particles that are distributed through the ductwork and into the house.
5.4 DUCT WORK
.
Heating cycle
Heating cycle
Heating cycle
Cooling cycle
Cooling cycle
 
A thermal imaging camera was used to check the supply registers. All the HVAC registers where getting conditioned air at the time of the inspection.
Top Table of Contents Bottom

6.  Water Heater

We inspect water heating equipment and hot water supply systems. We inspect the water heating equipment for function and configuration.  We do not guarantee that the water heater will not leak in the future. Water heaters leak. We will not take responsibility for water heater leaks that happen in the future.


Hot Water Soure::
Electrical Water Heater
Capacity:
40 Gallon
Approximate Age:
9 years
Average Service Life:
9-12 years
   

6.0 ELECTRIC WATER HEATER
.
Shut off valve for supply water
 
Hot water is supplied to the house with an electrical water heater. The shut off valve on the incoming water supply pipe is present. The tank has the properly sized electrical cable connected to it. The electrical grounding is visible.
6.1 TEMPERATURE & PRESURE RELIEF VALVE
.
 
CORRECTION RECOMMENDED:  The discharge pipe for the T&P valve on the water heater was PVC pipe. PVC is only rated for 73 degrees and is not an approved material to be used as a T&P valve discharge pipe. The pipe should be replaced with an approved pipe by a qualified person.
Top Table of Contents Bottom

7.  Plumbing System

Limitations of the plumbing inspection: Plumbing standards and codes have evolved over the years and home plumbing systems and their components are only required to comply with codes that were in effect at the time the home was built. The issue with various plumbing systems is not code compliance but the degree to which the installed system adequately provides for the  requirements of the home. This is our concern as Home Inspectors. If in our opinion the installed plumbing system or any of its components is failing to adequately provide for the  requirements of the home, we will recommend evaluation and/or correction by a qualified plumbing contractor.


Water Supply System:
Municipal Supply
Water Supply Piping:
Cross linked polyethylene (PEX)
Main Water shut off location:
In the utilty closet
Near the water heater
Sewage/Waste System::
Municipal Waste
Sewage Waste Piping::
PVC
 

7.0 WATER SUPPLY
.
  NOTE: The inspection of the plumbing system does not include the quantity or quality of the water supply. The source of the water supply should be confirmed with the seller or through public records.
Main water shut off valve
 
The water supply to the home is public. The water meter is located near the water heater. The main water shut off valve is under the meter. There is a back flow valve present, good. No leaks were observed near the water meter or at any of the visible fittings. The water pressure appeared adequate at the time of inspection. The meter has an electronic reader on it so the water company will not have to come into the house to read the meter.
7.1 MANA BLOC
.
 
The home has a Manabloc parallel feed water system that uses PEX tubing (polyethylene) to distribute water through out the house. The main water supply brings water to the manifold and individual distribution lines move water out to each fixture. The manifold has a built in valve at each distribution line port which allows you to stop the water flow to any single fixture without shutting down the entire system. There were no leaks observed at the manifold. All the distribution ports are labeled. All the unused ports do not have caps on them. Each distribution line is held off the wall correctly and comes out of the manifold at 90 degrees and is supported by a tube clamp within the first 4 to 6 inches, good.
 
CORRECTION RECOMMENDED: Each unused port on the Mana Bloc should have a cap on it. This is called for in the manufactures specifications and it is good plumbing practice. There are 14 ports with out caps. A qualified plumbing contractor should install caps on all unused ports.
Missing Valve key
 
CORRECTION RECOMMENDED: The manabloc valve key was missing. The valve key is needed in order to turn off and on the shut off valves. A qualified person should replace the key.
7.2 THERMAL EXPANSION TANK
.
Back flow valve
Expansion Tank
 
The water heater has an expansion tank installed above it. There is a back flow valve installed on the water supply line coming into the house. The back flow valve allows water to enter the home and prevents water from flowing back out to the street. This is to prevent water from being pulled out of the home if a back siphoning event were to occur in the public water supply. The back flow valve makes the homes plumbing system a closed water system.  When the water heater makes hot water, the water in the homes plumbing system expands. The expansion of water increases the pressure in the homes water pipes. The expansion tank absorbs the extra pressure. The action of the expansion tank reduces knocking of the pipes and wear and tear on the faucets and shut off valves due to the increased pressure. This tank appeared to be in good order.
7.3 DRAIN & WASTE SYSTEM
.
  Note: The sewer lateral from the home to the street or home to the septic system is beyond the scope of this inspection.
The type of sewage waste system should be confirmed with the seller or through public records.
 
The building is serviced with public sewer. The pipes were well supported. No visible cracks in any of the visible lines. Water was run at all the plumbing fixtures in the home. Clean out fitting was visible.
Top Table of Contents Bottom

8.  Electrical

Limitations of the Electrical inspection: If we feel that it is safe enough to open the electrical panel, we will check the interior components of service panels and sub panels, the conductors, and the overcurrent protection devices. Inside the house, we will check a representative number of installed lighting fixtures, switches, receptacles, and ground fault circuit interrupters. This is not an exhaustive inspection of every component and installation detail. We are not electricians. Therefore, it is essential that any recommendations that we may make for correction should be completed before the end of inspection contingency, because an electrician could reveal other problems or recommend additional repairs that may affect your evaluation of the property.


Service Cable Location:
Underground Service Line
Service Size:
100 AMP
Panel Type:
Circuit breakers
Main Disconnect:
Breaker at the meter
Wiring Method:
Romex
Service Grounding::
Undetermined

8.0 ELECTRICAL METER
.
 
The electric meters were inaccessible at the time of inspection.
8.1 MAIN ELECTRICAL PANEL
.
 
100 amp service at the electrical panel. There was an inspection sticker visible on the panel. The main breaker to shut off the electricity is at the meter. All of the breakers are labeled. All the wires running into the panel have cable connecters on them. No rust or corrosion visible inside the panel, on the wires, breakers or metal box itself. There is no more room for expansion in the panel. For safety remember to keep proper clearances around the panel.
8.2 ARC FAULT BREAKERS
.
 
The electrical panel is equipped with Arc fault circuit interrupter, or AFCI breakers. AFCI’s are the breakers with the yellow buttons. When this home was built AFCI breakers were installed on all the bedroom circuits in the home. These safety devices are intended to detect the kinds of electrical arcs that can cause fires. An AFCI breaker is designed to trip when it detects a dangerous arc, either in the house wiring or in a defective extension cord or appliance.
The AFCI breakers were tested using the test button on the breakers.  The AFCI breakers tripped when tested The AFCI breakers appear to be functioning as intended.
Top Table of Contents Bottom

9.  Interiors

Limitations of the interior inspection: We check only a representative number of doors and windows for basic function. We are not required to inspect the paint, wallpaper, the carpeting, the window treatments and screens. We do not move furniture, lift carpets or rugs, empty closets or cabinets, and we do not comment on cosmetic deficiencies. We may not comment on the cracks that appear around windows and doors, or which follow the lines of framing members and the seams of drywall and plasterboard. These cracks are usually a consequence of movement, such as wood shrinkage and common settling, and will often reappear. We do not report on odors from pets and cigarette smoke.


Smoke Detectors:
Hard wired with batter back up
Carbon Monoxide Detectors:
No
Dryer hook up:
Electric
Fireplace:
None
   

9.0 DOORS
.
 
All the doors opened and closed, latched and unlatched.
9.1 WINDOWS
.
  Please Read Carefully
Fogged windowpanes are normal wear and tear and can occur at any time in a double pane window. According to the ASHI Standards of Practice home inspectors are not required to report on fogged windowpanes.
However, as a courtesy fogged windowpanes if visible and observed at the time of inspection will be reported. Please note, fogged windowpanes are not always visible. Window treatments, different levels of sunlight, angles of the sun, and weather conditions can make it difficult to see fogged windowpanes. We will not take responsibility for fogged windowpanes that were not reported or windowpanes that fog in the future.
 
The windows that were inspected were functional with no significant defects observed. Windows are inspected for proper operation, condition of sill, sash, hardware and the condition of weather-sealing components.
9.2 CEILINGS
.
 
ASK THE SELLER: A water stain was observed on the kitchen ceiling. A moisture meter was used to probe the water stain. The meter did not detect any elevated levels of moisture in the ceiling. The stain appears to be from a past plumbing leak and does not seem to be active at the time of inspection. Recommend asking the seller for more information about the water stains and what corrective action was taken if any to correct the water issue.
9.3 RECEPTACLES
.
 
The receptacles that were inspected are properly wired.
9.4 SMOKE & CARBON MONOXIDE DETECTORS
.
  Note: PEACH Inspections recommends that smoke detectors be installed in each sleeping room, outside of each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements. We recommend testing all smoke detectors every week. Carbon monoxide detectors are recommend on each floor and outside of sleeping areas. Combination smoke detectors and carbon monoxide detectors are now available for hardwired systems. The buyer should consider upgrading their detectors if they have a hardwired system. All smoke detectors that are 10 years of age or older should be replaced (date of manufacture is typically posted on detector).
 
The smoke detectors in the home were *Identify smoke detectors*. All the installed detectors tested functional at the time of this inspection
9.5 LAUNDRY
.
  Note: We do not test clothes dryers, washing machines or their water connections and drainpipes. If a water catch pan is installed, it is not possible for us to check the performance of the pan and/or the drain line that may be attached to the pan. We recommend using steel braided water hoses for the washing machine's water supply lines. We recommend turning off the water to the washer during periods of nonuse. 
 
The dryer hook up is electric. The dryer duct is concealed inside the structure of the home and cannot be viewed for inspection. Don’t forget to clean the dryer duct regularly. If you have trouble cleaning the duct it can be done professionally by a certified chimney sweep or dryer duct specialist. I recommend asking the seller when the last time the dryer duct was cleaned. If there is no record of the dryer duct being cleaned within the last year I recommend prior to taking custody of the home having a qualified chimney sweep or dryer duct specialist clean the dryer duct.
 
IMPROVEMENT RECOMMENDED:  There was no overflow pan for the washing machine. There is no requirement for an overflow pan under the washing machine however since a leak from the washing machine could cause damage to the home I recommend that an overflow pan with a drain line to the exterior, or other location that would not ruin interior finishes, be installed under the washing machine.
Top Table of Contents Bottom

10.  Bathrooms

Limitations of the bathroom inspection: We inspect all bathroom fixtures, including toilets, tubs, showers, and sinks. Water is run at each fixture. Readily visible water-supply and drain pipes are inspected. Plumbing access panels are opened, if readily accessible and available to open. Saunas and steam showers are not operated but will be examined for visual defects. The inspector does not perform leak-testing of shower pans or shower enclosures but will comment on obvious leakage when fixtures are operated during the inspection.


Number of Full Baths:
One
Number of Half Baths:
None
Outlets GFCI Protected:
Yes

10.0 SINKS
.
 
The bathroom sink had hot and cold water running to it. The bathroom sink drained with no visible leaks at the drain pipe
10.1 TOILETS
.
 
The toilet flushed and appeared to be operating fine. The toilet was secure to the floor. There were no soft spots of flooring detected around the toilet.
10.2 TUBS & SHOWERS
.
 
The tub and shower had hot and cold water running to them. The tub and shower drained with no visible leaks. There were no soft spots of flooring detected around the tub and shower.
 
I recommend sealing (caulking) around the bathroom tub faucet to prevent water from running behind the tub/shower wall.
10.3 OUTLETS
.
 
All the bathroom receptacles had functional GFCI protection.
Top Table of Contents Bottom

11.  Kitchen

We check built in appliances as a courtesy. We are not required to evaluate them for their performance nor for the accuracy of their settings or cycles. If they are older than ten years, they may well exhibit decreased efficiency. Also, many older ovens are not secured to the wall to prevent tipping. Be sure to check the appliance, especially if children are in the house. We recommend installing a minimum five pound ABC-type fire extinguisher mounted on the wall inside the kitchen area.


Stove Cook Top:
Electric
Oven:
Electric
Microwave:
Yes
Dishwasher:
Yes
Garbage Disposal:
Yes
Outlets GFCI Protected:
Yes

11.0 STOVE & OVEN
.
 
The stove cook top and oven turned on with normal controls.
11.1 MICROWAVE
.
 
The microwave turned on with normal controls.
11.2 DISHWASHER
.
 
CORRECTION RECOMMENDED: An active leak was observed at the bottom of the dishwasher. Water was observed dripping onto the floor while the dishwasher was running through a short cycle. A qualified appliance repair contractor should repair or replace as needed.
11.3 KITCHEN SINK
.
 
Hot and cold water ran at the kitchen sink. There were no leaks under the sink at the water supply lines or the drain pipe.
11.4 GARBAGE DISPOSAL
.
 
The garbage disposal turned on.
11.5 OUTLETS
.
 
All the receptacles that serve a kitchen countertop are protected by functional GFCI protection. (Ground Fault Circuit Interrupter).
Top Table of Contents Bottom

12.  Your Final Pre-closing Walk Through

CONCLUSION:  
    We are proud of our service, and trust that you will be happy with the quality of our report. We have made every effort to provide you with an accurate assessment of the condition of the property and its components and to alert you to any significant defects or adverse conditions. However, we may not have tested every outlet, and opened every window and door, or identified every minor defect. Also because our inspection is essentially visual, latent defects could exist. We can not see behind walls. Therefore, you should not regard our inspection as a guarantee or warranty. It is simply a report on the general condition of a property at a given point in time. As a homeowner, you should expect problems to occur. Roofs will leak, drain lines will become blocked, and components and systems will fail without warning. We can not predict future events. For these reasons, you should keep a comprehensive insurance policy current. Thank you for taking the time to read this report, and Please call us if you have any questions. We are always attempting to improve the quality of our service and our report.
PRE-CLOSING WALK THROUGH:
The pre-closing walk through is the final time for you the buyer to inspect the property. Conditions can change between the time of the Home Inspection and the time of closing. Restrictions that existed during the Home Inspection may not exist during the final walk through. Defects that were not noted in the Home Inspection Report may become evident during the pre-closing walk through. The buyer should take time and look closely at the home.
    Any defect discovered during the pre-closing walk through should be addressed with the seller prior to closing. Purchasing a home with a known defect relieves Peach Inspection of all responsibility. The buyer should be aware that they assume responsibility for all known defects after settlement.
    Conditions can change between the time of the inspection and the time of closing, the following are some of the items recommended for the pre-closing walk through inspection.
1.  Check the heating and cooling system. Turn the thermostat to heat mode and turn the temperature setting up. Confirm that the heating system is running and making heat. Turn the thermostat to off and wait 20 minutes. Turn the thermostat to cool mode and turn the temperature setting down. Confirm the condenser is spinning and the system is making cool air. The cooling system should not be checked if the temperature is or was below 60 degrees the previous 24 hours or if the temperature was below freezing the night before the walk-through. And you should not operate a heat pump in the heating mode when it is over 75 degrees outside.
2.  Operate all appliances.
3.  Run water at all fixtures and flush toilets. Look for plumbing leaks.
4.  Operate all exterior doors, windows, and locks.
5.  Test smoke and carbon monoxide detectors.
6.  Ask for all remote controls to any garage door openers, fans, gas fireplaces, etc.
7.  Inspect areas that may have been restricted at the time of the inspection.
8.  Ask seller questions about anything that was not covered during the home inspection.
9.  Ask seller about prior infestation treatment and warranties that may be transferable.
10. Read the seller's disclosure.
Top Table of Contents Bottom

General Summary

The summary is supplemental to the report, not a substitute. The list is provided for the convenience of our clients to help them prioritize items mentioned in the report. We recommended referring to the full body of this report for further details on these and other items, and making their own summary list. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home.

 This summary list is not intended to be a complete list. There may be other items that are in need of improvement, repair or correction that are not listed here. There may also be improvements that are necessary, but are outside the scope of this inspection.

 If any evaluations or corrections are needed, then a professional should inspect the property even further, in order to discover and repair related problems that were not identified in the report. All corrections and evaluations should be made prior to purchasing the property.

 The following estimate and repair costs are provided for your convenience. They are not part of you inspection report. The costs are based on HomeTeck Remodeling and Renovation Cost Estimator 2017, and direct input from contractors in the local area.

 The costs are given in ranges, as required by the Pennsylvania home inspection law. The actual cost for your home repairs or improvements may be different from the cost listed here.

 PEACH Inspections always recommends getting three estimates from contractors who may be performing the work. PEACH Inspections makes no warranty or guarantee as to the correctness or sufficiency of the information contained in this list. PEACH Inspections assumes no responsibility or liability in connection with the use of this list.

1.  Pennsylvania Inspector Compliance Statement
1.0  Inspectors Comments  
.
The home is a condominium. Some of the homes components may be common elements that are maintained by the condominium association. It may also be difficult to determine what common elements are directly associated with this home. All components that are clearly associated with the home and are within the ASHI standards of practice will be inspected and reported on. 

The home buyer is advised to refer to the condominium documents prior to settlement for information regarding shared common building components, the schedule for performing repairs and maintenance on these building components and the associations budget for preforming repairs and maintenance on the building components.    


5.  Heating System
5.0  HEATING EQUIPMENT  
.

The home is heated and cooled with a Heat Pump.
Using the thermostat I turn the heat pump system on.
The system was run in heating mode, emergency heat mode and cooling mode.
The heat pump system appeared to function normally at the time of the inspection.

Heating and air conditioning systems require regular maintenance. There is no visible service tag on the HVAC heating system. I recommend asking the seller for recent service records. If the HVAC system has not been serviced within the last year I recommend having the system cleaned and serviced by an HVAC contractor prior to the end of inspection contingency..
$150-$200 Service call

6.  Water Heater
6.1  TEMPERATURE & PRESURE RELIEF VALVE  
.

CORRECTION RECOMMENDED:  The discharge pipe for the T&P valve on the water heater was PVC pipe. PVC is only rated for 73 degrees and is not an approved material to be used as a T&P valve discharge pipe. The pipe should be replaced with an approved pipe by a qualified person.
$20-$40

7.  Plumbing System
7.1  MANA BLOC  
.

CORRECTION RECOMMENDED: Each unused port on the Mana Bloc should have a cap on it. This is called for in the manufactures specifications and it is good plumbing practice. There are 14 ports with out caps. A qualified plumbing contractor should install caps on all unused ports.
$100-$200

CORRECTION RECOMMENDED: The manabloc valve key was missing. The valve key is needed in order to turn off and on the shut off valves. A qualified person should replace the key.
0-$100

9.  Interiors
9.2  CEILINGS  
.

ASK THE SELLER: A water stain was observed on the kitchen ceiling. A moisture meter was used to probe the water stain. The meter did not detect any elevated levels of moisture in the ceiling. The stain appears to be from a past plumbing leak and does not seem to be active at the time of inspection. Recommend asking the seller for more information about the water stains and what corrective action was taken if any to correct the water issue.
Ask Seller about item

11.  Kitchen
11.2  DISHWASHER  
.

CORRECTION RECOMMENDED: An active leak was observed at the bottom of the dishwasher. Water was observed dripping onto the floor while the dishwasher was running through a short cycle. A qualified appliance repair contractor should repair or replace as needed.
Need Estimate


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Steve Robinson
Top Table of Contents Bottom

Report Attachments

ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received an emailed PDF version of this page and did not receive a copy of the report through the internet please contact your inspector for a PDF copy of the attachments.

ASHI Standards of Practice

Home Inspection Law