Dear Home Buyer

Attached please find your home inspection report for 100 Main Street performed on 4/2/2021. Thank you for choosing Clarity Home Inspection to perform your home inspection. We understand the emotions and potential anxiety that come with purchasing a home and we strive to ensure that you have a comprehensive understanding of your new home’s condition to help alleviate that.

This inspection report reflects the visual conditions of the property at the time of the inspection only. The inspection was performed in accordance with the NJ Home Inspection Standards of Practice. We recommend you read the entire report.

No warranty is either expressed or implied. This report is not an insurance policy, nor a warranty service.

Some items noted in the attached report should receive attention, but none of them affect the habitability of the house. Correction of items resulting from normal wear and tear is typically considered part of normal home maintenance and upkeep.

We are always availble to answer any questions you may have regarding the inspection report or the home, so p
lease do not hesitate to contact us at anytime.


Sincerely,

CLARITY HOME INSPECTION

(908) 334-9547

InterNACHI Certified Professional Inspector

NJ Home Inspector License # 24GI00209400

NJ Radon License # MET14329

NJ Wood Destroying Insect License # 62403B

FAA Remote Pilot UAS #

IAC2 – Mold Certified

chris@ClarityHomeInspectionNJ.com

Top Table of Contents Bottom
Top Table of Contents Bottom
General Info
Property Address
100 Main Street
New Home NJ 07000
Date of Inspection
4/2/2021
Report ID
SampleReport - Clarity Home Inspection
Customer(s)
Home Buyer
Time of Inspection
10:00 AM
Real Estate Agent


Inspection Details
Standards of Practice:
NJ Standards of Practice

Type of building::
Single Family (2-story)

Approximate Year of Original Construction::
1950

Inspection started at::
10am

Inspection ended at::
1pm

Occupancy::
The home was occupied

Attending the Inspection::
Buyer and Buyer's Agent

Weather during the Inspection::
Clear

Significant precipitation in last 3 days::
No

Temperature during inspection::
Between 80-90 (F)

Ground/Soil surface condition:
Dry

Radon Test:
In progress

Comment Key & Definitions

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.

Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.

Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.

Marginal/Maintenance (MM) = Item warrants attention or monitoring or has a limited remaining useful life expectancy and may require replacement in the near term. Further evaluation or servicing may be needed by a qualified licensed contractor or specialty tradesman dealing with that item or system.

Not Present (NP) = This item, component or unit is not in this home or building.

Repair or Replace (RR) = Item, component, or unit is not functioning as intended and needs repair or replacement by a qualified professional. Further evaluation is needed by a qualified licensed contractor or specialty tradesman dealing with that item or system.

Top Table of Contents Bottom

General Summary


CLARITY HOME INSPECTION

55 Winding Lane
Basking Ridge, NJ 07920

Customer
Home Buyer

Address
100 Main Street
New Home NJ 07000

The General Home Inspection is a limited visual, non-invasive examination of the function and condition of a home’s systems and components. The purpose of the home inspection is to identify and report on material defects found in those systems and components. The inspection is not technically exhaustive nor is it a building code-compliance inspection.

The following items or discoveries indicate that these systems or components either

1) do not function as intended
or adversely affects the habitability of the dwelling
2) warrants further investigation by a specialist,
or
3) requires subsequent observation.

This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home.

This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

2. Grounds
2.1 Driveway  
Marginal/Maintenance
The home had an asphalt driveway.

Common cracks (one-quarter inch or less) were visible in the driveway. Cracks exceeding one-quarter inch should be filled with an appropriate sealant to avoid continued damage to the driveway surface from freezing moisture.
2.1 Item 1 (Picture)
2.3 General Grounds & Grading  
Repair/Replace
The home had areas of neutral or negative drainage in the front yard that will route runoff from precipitation toward the foundation. Excessively high moisture levels in soil supporting the foundation can cause a wet basement and effect its ability to support the weight of the structure above. The ground should slope away from the home a minimum of ¼-inch per foot for a distance of at least six feet from the foundation. The Inspector recommends that these areas be re-graded to improve drainage near the foundation.

Proper re-grading may include the use of swales which are depressions created in the ground that carries/re-routes rainwater by gravity away from your home and property.

2.3 Item 1 (Picture)
Negative grade - Front
2.3 Item 2 (Picture)
Swales for drainage
3. Wall Exteriors
3.0 Vinyl Siding  
Repair/Replace
(1) The exterior cladding (siding) in the back of the house is too close to grade (the ground). All types of exterior cladding should have a minimum of 6" to 8" clearance above the finished grade to prevent damaging water wicking and prevent insect/pest entry into the wall envelopes. I advise having a qualified professional expose the masonry foundation between the exterior finished grade and the existing wall cladding to the 6”to 8” recommended clearance.
3.0 Item 1 (Picture)
Siding on Rear of House
3.0 Item 2 (Picture)
(2) The vinyl siding on the left of the exterior had areas of cracked or broken siding that should be sealed or replaced to prevent potential damage from moisture intrusion into the home's structure/materials and to prevent development of microbial growth such as mold. All work should be performed by a qualified contractor.
3.0 Item 3 (Picture)
Damaged Siding
3.8 Exterior Foundation - Materials & Condition  
Repair/Replace
A parge coat was visible at the foundation’s exterior surface. A parge coat is a thin layer of cementitious, plaster-like material applied with a trowel and designed to harden, cover and protect the exterior surface of the foundation wall. Therefore, visibility and ability to inspect the foundation exterior wall material was not possible and is disclaimed.

Spalling was visible on the exterior surface of the visible exterior concrete/brick walls. Spalling is surface deterioration which causes fragments/flakes of concrete to detach from the surface. The Inspector recommends patching with an appropriate material by a qualified professional to help prevent continued deterioration and possible water infiltration.
3.8 Item 1 (Picture)
Left Rear Corner
3.10 Exterior - Other  
Marginal/Maintenance
On the exterior of the home, the inspector noticed numerous rodent traps which indicates prior/current rodent activity. The Inspector recommends that you contact a pest control contractor to confirm rodent problem has been resolved prior to the end of your inspection obligation deadline.
3.10 Item 1 (Picture)
4. Roof
4.3 Roof Condition  
Marginal/Maintenance
(2) Tree branches are overhanging the roof. This will cause lichen and moss to grow which will hold moisture on the roof longer than other areas and will advance wear on the shingles. In freezing climates there may be faster frost damage, cracking, and wear of the shingles. Branches in contact the roof will accelerate wear due to abrasion(s) and will allow animals to access the roof and possibly the attic. All tree branches touching or overhanging the roof should be trimmed back away from the home by a qualified professional.
4.3 Item 3 (Picture)
Left Front Roof - Overhanging Branches
4.3 Item 4 (Picture)
Lichen/moss - Left Front Roof
4.3 Item 5 (Picture)
Front Left Roof
4.8 Roof Drainage System - Gutters & Downspouts  
Repair/Replace
(1) Debris visible in the gutters at the time of the inspection should be removed to encourage proper drainage.
4.8 Item 1 (Picture)
(2) One or more downspouts discharged roof drainage next to the foundation. This condition can effect the ability of the soil to support the weight of the structure above and can cause damage related to soil/foundation movement. The Inspector recommends the installation of downspout extensions to discharge roof drainage a minimum of 6 feet from the foundation.
4.8 Item 2 (Picture)
Front Right Corner
5. Chimney
5.0 Chimney Exterior Condition  
Repair/Replace
The brick chimney exhibited moderate deterioration such as brick spalling, crumbling, or delamination of the brick face. This is typically caused over the long-term by a combination of moisture absorption, moisture expansion during freezing, and improper mortar mix design. This deterioration will probably continue unless the problem is identified and corrected. The inspector recommends that you consult with a qualified masonry contractor to discuss options and costs for repair and stabilization as necessary.
5.0 Item 1 (Picture)
Brick Spalling
5.2 Chimney Cap/Crown  
Repair/Replace
The chimney crown was deteriorated and had several cracks that should be repaired by a qualified professional to avoid continued damage from moisture intrusion and the freeze/thaw cycle.
5.2 Item 1 (Picture)
5.2 Item 2 (Picture)
Cracking Chimney Crown
6. Garage
6.2 Conventional Doors  
Repair/Replace
(2) The fire rated door between the living space and the garage failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. Recommend to have corrected by a qualified professional.
8. Basement
8.2 Moisture  
Marginal/Maintenance
In the basement, small amounts of efflorescence was visible at some of the interior surfaces of the foundation walls. Efflorescence is a white, powdery residue left by moisture seeping through the foundation wall and its presence indicates high moisture levels in soil near the foundation. Excessively high moisture levels in soil supporting the foundation can cause various structural problems related to soil movement. This area should be monitored for future signs of moisture intrusion in an effort to identify and correct the source of moisture.
8.2 Item 1 (Picture)
Efflorescence - Front wall
8.2 Item 2 (Picture)
9. Interior
9.7 Stairs & Handrails  
Repair/Replace
The handrail at this staircase was loose and not adequately secured to the wall which is a safety hazard should someone fall. Inspector recommends correction by a qualified contractor to ensure the handrail attachment to the wall is secured.
9.7 Item 1 (Picture)
Handrail to 2nd Floor
11. Bathrooms
11.0 Sink(s) & Cabinetry  
Inspected, Repair/Replace
(2) A trap beneath a sink the the master bathroom was of a type called an "S-trap". S-traps are no longer allowed to be installed in new construction for safety reasons. A siphon can develop which empties the trap of water; a condition with the potential to allow toxic sewer gas to enter the living space. Although this type of trap may have been commonly considered safe at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. The Inspector recommends replacement of all such traps in the home by a qualified plumbing contractor.
11.0 Item 4 (Picture)
Master Bath
11.0 Item 5 (Picture)
Master Bath Undersink - S-Trap
11.0 Item 6 (Picture)
11.0 Item 7 (Picture)
Illegal Traps
12. Electrical
12.1 Electric Meter  
Inspected, Marginal/Maintenance
(2) The electrical meter tag/seal has been cut. The penalties for cutting a security tag on the electric meter vary depending on the utility service provider and local laws. The penalties can range from fines all the way up to misdemeanor charges. I recommend notifying the utility company that the tag has been cut and is in need of replacement.
12.1 Item 2 (Picture)
Cut Tag
12.6 Service Panel Wiring  
Repair/Replace
(2) Buss bar set screws are only rated for two (2) ground wires or one (1) neutral wire under each screw. The buss bar set screws had more wire than it was rated for. Having more wires that the set screw is rated for may result in a poor connection and/or excessive heat. Recommend correction by a licensed electrician.
12.6 Item 2 (Picture)
12.11 GFCI/AFCI Electrical Receptacles  
Repair/Replace
The exterior outlet/receptacle in the front left corner of the house was not GFCI (ground fault circuit interrupter) protected.

Although GFCI protection may not have been required at the time the home was built, for safety reasons, the Inspector recommends that this receptacle be updated to a GFCI receptacle by a licensed electrician.

Note - GFCI protected receptacles provide protection from electric shock and or electrocution hazards in areas prone or susceptible to moisture.  Therefore electrical receptacles located in basements, crawlspaces, garages, the home exterior, and interior receptacles located within 6 feet of a plumbing fixture should be provided with GFCI protection.
12.11 Item 1 (Picture)
Exterior Outlet Front Left Corner
12.13 Junction Boxes  
Repair/Replace
Switch cover plates were missing in various rooms in the home. This condition left energized electrical components exposed to touch, a shock/electrocution hazard. The Inspector recommends that listed cover plates be installed by a qualified electrical contractor.
12.13 Item 1 (Picture)
Basment Ceiling Near Furnace
12.13 Item 2 (Picture)
Attic Floor
12.14 Exterior Wiring  
Repair/Replace
Both exposed wiring and electrical wiring not rated for exterior use were used for an exterior application. This condition left energized electrical components exposed to touch and is a potential shock/electrocution hazard. Recommend to have wires corrected and secured by a qualified electrical contractor.
12.14 Item 1 (Picture)
Left Side of Exterior
13. Plumbing
13.2 DWV - Drain, Waste, & Vent Systems  
Inspected, Repair/Replace
(2) Surface rust/corrosion was noted. It appears to be from a current/prior leak above the floor which was inaccessible to the inspector. The Inspector recommends to have a licensed plumber ensure there is no leak and/or replace the corroded piping.
13.2 Item 3 (Picture)
Corrosion
13.4 Gas Water Heater  
Inspected, Repair/Replace
(3) The installed vent pipe "Y" was not approved for this purpose. Gaps were also noted. This condition has the potential to allow the toxic products of combustion to enter the living space. The Inspector recommends immediate replacement by a qualified HVAC contractor.
13.4 Item 3 (Picture)
Y Vent
13.4 Item 4 (Picture)
Y Vent Gaps
14. Heating
14.0 Fuel Supply  
Repair/Replace
The gas meter on the exterior front of the house was located too close to grade. The grade should be 6" below base of meter to prevent premature aging of the meter. The inspector recommends having grade lowered to at least 6" below base of meter by a qualified professional.

Should lowering the grade create surface runoff that drains towards the foundation a window well should be installed around the meter. This excavation will ensure that runoff is kept away from the meter and foundation.
14.0 Item 1 (Picture)
Gas Meter
14.8 Fireplace  
Inspected, Repair/Replace
(2) The exhaust flue of the wood-burning fireplace appeared to need cleaning. Dirty flues are potential fire hazards. The flue should be cleaned by a qualified contractor prior to first time use.
14.8 Item 2 (Picture)
15. Cooling
15.1 AC Suction Line  
Repair/Replace
The refrigerant suction line for the exterior unit is exposed and needs pipe insulation which can reduce efficiency and cooling.  Recommend to have repaired by a licensed air conditioning contractor.
15.1 Item 1 (Picture)


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Christopher Swatt
Top Table of Contents Bottom
Results at a glance

120

Items Inspected

Total number in report.

25

Summary Comments

Total number in report.

65

Styles & Materials

Total number in report.

114

Photos

Total number in report.

1. Home Inspection Description
Description
The General Home Inspection is a limited visual, non-invasive examination of the function and condition of a home’s systems and components. The purpose of the home inspection is to identify and report on material defects found in those systems and components. The inspection is not technically exhaustive nor is it a building code-compliance inspection. If you wish to ascertain the degree to which the home complies with any applicable building codes, you should arrange a code-compliance inspection with the municipality in which the property is located.

The home may not meet many of today’s current generally-accepted building standards. Older homes are inspected within the context of the time period in which they were built, taking into account the generally-accepted building practices of that time period. Homes are not required to be continually upgraded as building codes change. An exception may exist when a home is remodeled, depending on the scope of work and typically new work must comply with the building codes in effect at the time of the remodel. The Inspection Report will comment on unsafe conditions, but problems will be described as defects at the Inspector's discretion.

Houses built prior to 1978 have the potential of containing lead paint. The actual content of the paint on this structure can NOT be evaluated without specialized lead paint testing. If the house or any portion of the house was constructed prior to 1978 it is recommended to have the home tested for lead paint by a licensed lead paint specialist prior to closing. Concerns regarding lead paint should be addressed with the local health department or the Consumer Product Safety Commission.

The General Home inspection does not include confirmation of the presence of allergens of any type. Testing for allergens requires a specialist inspection. The Inspector recommends that you have specialist testing performed if allergens are of a concern to you. You should consider having tests performed if you expect those suffering from allergies, asthma, lung disease or who have compromised immune systems to be present in the home.

Any suggestions in this report for evaluation, repair or replacement should always be performed by a qualified professional or specialty tradesman dealing with that item or system.

Please read the entire report for important details.

CONDO/TOWNHOUSE DISCLAIMER

Condominium or Town House inspections are partial inspections performed only on those components that the buyer/homeowner is responsible for. It does not include the exterior components of the property, crawlspace, or attic as those components are typically owned by the association and not owned by the buyer/homeowner. It is up to the buyer to determine if any of these excluded areas are in fact the buyer’s responsibility and if so, to notify the inspector so these areas can be inspected. Please note a different charge will apply should the buyer want these areas inspected. At times it may not be possible in some cases to inspect attic areas where a duplex unit exists and the buyer is purchasing the lower unit, or vice versa. Our company makes no representation as to the condition of these areas that were not inspected and are therefore disclaimed. Any areas inspected that are not the responsibility of the buyer/homeowner is for informational purposes only and we assume no liability.

HOME ORIENTATION

All references to orientation throughout the report are as if viewing the home from the front, street side.

Items: Home Inspection Description
1.0 Home Inspection Limitations
The General Home Inspection is a limited, non-invasive examination limited to the readily accessible and visible systems, equipment and components of the home. The inspector will not dismantle or move any equipment, systems, components, personal property, furniture, appliances, plants, soil, snow/ice, and or debris in order to conduct the inspection or to expose concealed or inaccessible conditions. Any areas not visible or accessible at the time of inspection cannot and will not be inspected.

This report is intended only to be a general guide in order to assist the client in making his/her own evaluation as to the overall condition of the home. It is not intended to reflect the value of the premises, nor make any representation as to the advisability of purchase.

The inspection is performed in compliance with generally accepted standards of practice, a copy of which is available upon request. The report expresses the personal opinions of the inspector, based upon his visual impressions of the conditions that existed at the time of the inspection only.

The General Home Inspection does not include inspection or evaluation of the adequacy or efficiency of insulation or heating and cooling equipment; playground equipment; internal or underground drainage or plumbing; any systems which are shut down or otherwise secured; water wells (water quality and quantity); zoning ordinances; intercoms; security systems; heat sensors; cosmetics or building code conformity. The Inspection does not include inspection for the presence of formaldehyde, lead paint, asbestos, toxic or flammable materials, and other environmental hazards, or pest infestation. Any general comments about these above systems and conditions are informational only and do not represent an inspection.

The Client understands that the inspection and report do not, in any way, constitute a guarantee, warranty of merchantability or fitness for a particular purpose, express or implied warranty, or an insurance policy and are not intended to provide any guarantee of the present and/or future adequacy and performance of the property’s structure, systems, or component parts.

Any opinions expressed regarding adequacy, capacity, or expected life of components are general estimates based on information about similar components and occasional wide variations are to be expected between such estimates and actual experience.

We certify that our inspectors have no interest, present or contemplated, in this property or its improvement and no involvement with trades people or benefits derived from any sales or improvements. To the best of our knowledge and belief, all statements and information in this report are true and correct.

Should any disagreement or dispute arise as a result of this inspection or report, it shall be decided by arbitration and shall be submitted for binding, non-appealable arbitration to the American Arbitration Association in accordance with its Construction Industry Arbitration Rules then obtaining, unless the parties mutually agree otherwise. In the event of a claim, the Client will allow the Inspection Company to inspect the claim prior to any repairs or waive the right to make the claim. Client agrees not to disturb or repair or have repaired anything which may constitute evidence relating to the complaint, except in the case of an emergency.

Smoke/fire/carbon monoxide detectors (functionality of, power source, placement) are not part of this inspection. If no smoke/fire/carbon monoxide detectors are installed, you should consider installation of battery operated and/or hardwired smoke/fire/carbon monoxide detectors in all recommended locations per the municipality’s requirements. Upon taking occupancy, proper operating and placement of smoke/fire/carbon monoxide detectors should be verified and batteries should be changed. Note that these devices have a limited life span and should be replaced at a minimum of every 10 years.
2. Grounds
Description
The General Home Inspection of the grounds typically includes adequate surface drainage from the foundation; driveway and walkways; decks; patios; porches; balconies; exterior stairs;window wells; and retaining wall conditions that may affect the home structure.

This Inspection does not include inspection of detached buildings or structures (i.e. sheds); playground, recreation or leisure equipment; sport courts; landscape irrigation systems or water features; fencing and gates; retractable awnings; swimming pools/spas; underground drainage systems; catch basins or concealed sump pumps. This inspection is not intended to provide any evaluation of trees, landscaping or landscape components including firepits, patio fans, heat lamps and low voltage lighting, nor is the inspection intended to address or include any geological conditions, site and soil stability information; erosion or erosion control measures. Any comments made regarding these items are as a courtesy only.

Note the potential for dangers/damage associated with trees such as falling branches or root damage to foundations varies with tree species and age, and would require an arborist evaluation.

Any reference to grade is limited to only areas around the exterior of the exposed areas of foundation or exterior walls. We cannot determine drainage performance of the site or the condition of any underground piping, including subterranean drainage systems and municipal water and sewer service piping or septic systems. All exterior grades should allow for surface and roof water to flow away from the foundation. Decks and porches are often built close to the ground, where no viewing or access is possible. Any areas too low to enter or not accessible are excluded from the inspection. Any such mention of these items is informational only and not to be construed as inspected.
Styles & Materials: Grounds
Driveway Material:
Asphalt
Walkway Materials:
Masonry paver
 
Items: Grounds
2.0 Exterior View - Aerial
2.0 Item 1 (Picture)
Aerial Property View
2.1 Driveway
Comments: Marginal/Maintenance
The home had an asphalt driveway.

Common cracks (one-quarter inch or less) were visible in the driveway. Cracks exceeding one-quarter inch should be filled with an appropriate sealant to avoid continued damage to the driveway surface from freezing moisture.
2.1 Item 1 (Picture)
2.2 Walkways
Comments: Inspected
The walkway was masonry pavers and appeared in satisfactory condition at the time of inspection.
2.2 Item 1 (Picture)
2.3 General Grounds & Grading
Comments: Repair/Replace
The home had areas of neutral or negative drainage in the front yard that will route runoff from precipitation toward the foundation. Excessively high moisture levels in soil supporting the foundation can cause a wet basement and effect its ability to support the weight of the structure above. The ground should slope away from the home a minimum of ¼-inch per foot for a distance of at least six feet from the foundation. The Inspector recommends that these areas be re-graded to improve drainage near the foundation.

Proper re-grading may include the use of swales which are depressions created in the ground that carries/re-routes rainwater by gravity away from your home and property.
2.3 Item 1 (Picture)
Negative grade - Front
2.3 Item 2 (Picture)
Swales for drainage
2.4 Porch/Patio
The rear patio was stamped concrete and was in satisfactory condition at the time of inspection.


NOTE – to best preserve and protect stamped concrete it is recommended that it be periodic sealed (every 1-2 years) with a concrete sealer to protect from UV damage, moisture penetration, freeze-thaw conditions, de-icing chemicals, and abrasion.

2.4 Item 1 (Picture)
Rear Patio
2.5 Exterior Stairs
Comments: Inspected
The rear exterior stairs are composite decking and were in satisfactory condition at the time of inspection.
2.5 Item 1 (Picture)
3. Wall Exteriors
Description
The General Home inspection of the wall exteriors typically includes a visual inspection of accessible components or systems at the exterior including wall cladding, flashings, and trim; entryway doors and a representative number of windows; and eaves, soffits, and fascias.

The General Home Inspection does not include inspection of below grade foundation walls and footings; shutters; screens; manual or electric awnings; any exterior surfaces or components that are obscured by vegetation, personal property, or debris; any wall structures obscured by coverings such as siding or trim. Note that a full evaluation will be limited on certain exterior components high off the ground such as siding, trim, soffits, vents and windows.

Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. It should also be noted that it is impossible to determine where leakage may be occurring at or within exterior walls that are covered with wood, vinyl or aluminum siding materials. Rainwater leakage can occur at window and door openings without leaving visual clues to its presence. In such cases, the existence or probability of leakage cannot be detected without destruction of wallboard or siding which is beyond the scope of a visual home inspection.

It is recommended that homeowners caulk the exterior perimeters of all windows, and to monitor the status of wallboard at the interior of windows and floor coverings at the interior of door openings for formation of stains which would indicate the presence of a leak. Any exterior area with protruding trim that could catch rainwater should also be monitored for leakage.
Styles & Materials: Wall Exteriors
Exterior wall-covering Material:
Vinyl Siding
 
 
Items: Wall Exteriors
3.0 Vinyl Siding
Comments: Repair/Replace
(1) The exterior cladding (siding) in the back of the house is too close to grade (the ground). All types of exterior cladding should have a minimum of 6" to 8" clearance above the finished grade to prevent damaging water wicking and prevent insect/pest entry into the wall envelopes. I advise having a qualified professional expose the masonry foundation between the exterior finished grade and the existing wall cladding to the 6”to 8” recommended clearance.
3.0 Item 1 (Picture)
Siding on Rear of House
3.0 Item 2 (Picture)
(2) The vinyl siding on the left of the exterior had areas of cracked or broken siding that should be sealed or replaced to prevent potential damage from moisture intrusion into the home's structure/materials and to prevent development of microbial growth such as mold. All work should be performed by a qualified contractor.
3.0 Item 3 (Picture)
Damaged Siding
3.1 Exterior Doors
Comments: Inspected
3.2 Exterior Windows - Type
Comments: Inspected
Predominantly Double Hung/Double Pane
3.2 Item 1 (Picture)
3.2 Item 2 (Picture)
3.3 Exterior Windows - Condition
Comments: Inspected
Satisfactory overall, considering age.
3.4 Window Sills
Comments: Inspected
The window sills appeared satisfactory at the time of inspection.
3.5 Exterior Trim
Comments: Inspected
The exterior trim appeared satisfactory at the time of inspection.
3.6 Eaves - Soffits - Fascia
Comments: Inspected
Soffit vents appeared adequate at the time of inspection.
3.6 Item 1 (Picture)
3.7 Exterior Wall Penetrations
Comments: Inspected
Exterior wall penetrations for were properly sealed to avoid water penetration and or rodent/pest entry.
3.8 Exterior Foundation - Materials & Condition
Comments: Repair/Replace
A parge coat was visible at the foundation’s exterior surface. A parge coat is a thin layer of cementitious, plaster-like material applied with a trowel and designed to harden, cover and protect the exterior surface of the foundation wall. Therefore, visibility and ability to inspect the foundation exterior wall material was not possible and is disclaimed.

Spalling was visible on the exterior surface of the visible exterior concrete/brick walls. Spalling is surface deterioration which causes fragments/flakes of concrete to detach from the surface. The Inspector recommends patching with an appropriate material by a qualified professional to help prevent continued deterioration and possible water infiltration.
3.8 Item 1 (Picture)
Left Rear Corner
3.9 Exterior Foundation - Movement
Comments: Inspected
There is no evidence of any recent movement.
3.10 Exterior - Other
Comments: Marginal/Maintenance
On the exterior of the home, the inspector noticed numerous rodent traps which indicates prior/current rodent activity. The Inspector recommends that you contact a pest control contractor to confirm rodent problem has been resolved prior to the end of your inspection obligation deadline.
3.10 Item 1 (Picture)
4. Roof
Description
The roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor. Because of variations in installation requirements of the wide range of different roof-covering materials installed over the years, the General Home Inspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognize conditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-covering materials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts for evaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roof against future leakage. Other limitations may apply and will be included in the comments as necessary.

                                                                      Gutters & Downspouts

Keep gutters clean and clear of debris. Water leading away from the foundation should be channeled at least 6 to 10 feet from the home to prevent water from being discharged next to the foundation. Gutters do require re-nailing and should be checked periodically. Please note that periodic checks should be made on any downspouts at the home that are connected to underground piping / perimeter drains to ensure there is no blockage. Any blockage in the drain pipes may cause roof drainage to be diverted to the soil around and beneath the home foundation.

Excessive moisture near the foundation can result in structural failure due to foundation movement or moisture intrusion with the potential to cause structural damage from decay. Moisture intrusion can also cause the development of unhealthy conditions in indoor air quality related to microbial growth such as mold fungi. Homeowners should be diligent in keeping the roof and gutters free of debris to avoid creating blockages in the perimeter drainage system.
Styles & Materials: Roof
Method of inspection:
Drone with camera
The roof style was:
Gable
Primary roof-covering type:
Architectural Fiberglass Asphalt Shingle
Drainage system description:
Gutters and downspouts
Gutters/downspout material:
Aluminum
 
Items: Roof
4.0 Roof Access
UAS Remote Aerial Roof Inspection
4.0 Item 1 (Picture)
4.1 Roof Structure Exterior
Comments: Inspected
4.2 Asphalt Shingles
Comments: Inspected
The roof was primarily Dimensional Architectural Asphalt Shingles with a small section of roll roofing in one of the valleys.
4.2 Item 1 (Picture)
4.2 Item 2 (Picture)
4.2 Item 3 (Picture)
Roll Roofing
4.3 Roof Condition
Comments: Marginal/Maintenance
(1) There appears to been a recent addition in the rear of the house.  The new roofing on the addition is tied into the older roofing of the existing house so there are two different ages of the roofing material.  The existing roofing appears to be in fair condition but past the mid point of it's long term service life.
4.3 Item 1 (Picture)
4.3 Item 2 (Picture)
(2) Tree branches are overhanging the roof. This will cause lichen and moss to grow which will hold moisture on the roof longer than other areas and will advance wear on the shingles. In freezing climates there may be faster frost damage, cracking, and wear of the shingles. Branches in contact the roof will accelerate wear due to abrasion(s) and will allow animals to access the roof and possibly the attic. All tree branches touching or overhanging the roof should be trimmed back away from the home by a qualified professional.
4.3 Item 3 (Picture)
Left Front Roof - Overhanging Branches
4.3 Item 4 (Picture)
Lichen/moss - Left Front Roof
4.3 Item 5 (Picture)
Front Left Roof
4.4 Valleys
Comments: Inspected
The valleys appeared to be in satisfactory condition at the time of inspection. The valleys on the roof are closed, using either overlapping or interwoven strip shingles from both intersecting roof lines.
4.4 Item 1 (Picture)
4.4 Item 2 (Picture)
4.5 Roof Flashing
Comments: Inspected
The roof flashings appeared in satisfactory condition at the time of inspection.

"Flashing" is the term used to describe sheet metal fabricated into shapes used to protect areas of the roof from moisture intrusion. Typical areas of installation include along headwalls, sidewalls, roof and wall penetrations such as vent pipes, chimneys, skylights and areas where dissimilar roofing materials or different roof slopes meet.

4.6 Plumbing and Combustion Vents
Comments: Inspected
The plumbing vents were PVC and appeared to be in serviceable condition at the time of inspection.
4.6 Item 1 (Picture)
4.6 Item 2 (Picture)
4.7 Roof Ventilation Provisions
Comments: Inspected
Ventilation is provided by ridge vents and soffit vents and appeared in satisfactory condition at the time of inspection
4.8 Roof Drainage System - Gutters & Downspouts
Comments: Repair/Replace
(1) Debris visible in the gutters at the time of the inspection should be removed to encourage proper drainage.
4.8 Item 1 (Picture)
(2) One or more downspouts discharged roof drainage next to the foundation. This condition can effect the ability of the soil to support the weight of the structure above and can cause damage related to soil/foundation movement. The Inspector recommends the installation of downspout extensions to discharge roof drainage a minimum of 6 feet from the foundation.
4.8 Item 2 (Picture)
Front Right Corner
5. Chimney
Description
Our chimney inspection is a “Level 1” inspection and conforms to industry standards which are that of a generalist, not a specialist.

A chimney inspection does not include coal stoves, gas logs, or chimney flues. Any potential comments made regarding these items are to be treated as a courtesy only. The inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, nor does the inspector light any fires.

The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth “Level 2” chimney inspection (i.e. a camera scan of the entire length of the interior of the flue) should be performed as part of every sale or transfer of property with a wood-burning device. A "Level 2" inspection may reveal defects not apparent to the home inspector's "level 1" inspection.

Because our inspection of chimneys is limited only to areas easily viewed, significant areas of the interior chimney flues (for heating, fireplaces and/or wood stoves) cannot be adequately evaluated during a field inspection without the use of specialized equipment. We therefore will not guarantee the chimney’s integrity or drafting ability and recommend that it be more thoroughly evaluated/inspected by a qualified chimney specialist before the close of escrow.

It is highly recommended to have all fireplaces cleaned and serviced by a qualified chimney sweep prior to fist time use.
Styles & Materials: Chimney
Chimney Exterior Material:
Brick
 
 
Items: Chimney
5.0 Chimney Exterior Condition
Comments: Repair/Replace
The brick chimney exhibited moderate deterioration such as brick spalling, crumbling, or delamination of the brick face. This is typically caused over the long-term by a combination of moisture absorption, moisture expansion during freezing, and improper mortar mix design. This deterioration will probably continue unless the problem is identified and corrected. The inspector recommends that you consult with a qualified masonry contractor to discuss options and costs for repair and stabilization as necessary.
5.0 Item 1 (Picture)
Brick Spalling
5.1 Chimney Flashing
Comments: Inspected
The installed flashing around the chimney stack appears to be functional and in satisfactory condition.
5.1 Item 1 (Picture)
Chimney Flashing
5.2 Chimney Cap/Crown
Comments: Repair/Replace
The chimney crown was deteriorated and had several cracks that should be repaired by a qualified professional to avoid continued damage from moisture intrusion and the freeze/thaw cycle.
5.2 Item 1 (Picture)
5.2 Item 2 (Picture)
Cracking Chimney Crown
5.3 Chimney Height & Clearance
Comments: Inspected
The chimney had adequate clearance above the roof surface.
6. Garage
Description
The General Home Inspection of the garage typically includes a visual inspection of the visible and accessible components or systems of the general structure; floor, wall and ceiling surfaces; operation of all accessible conventional doors and door hardware; vehicle door condition and operation; proper electrical condition including Ground Fault Circuit Interrupter (GFCI) protection; interior and exterior lighting; stairs and stairways; and proper floor drainage.

For safety reasons, walls & ceilings separating garages from living space in the home should be fire retarding or protected by masonry products or drywall applications and the doors should be fire rated doors (not hollow core interior style doors). The inspector does not determine the adequacy of firewall ratings. Determining the heat resistance rating of fire walls is beyond the scope of this inspection.

Flammable materials should not be stored within closed garage areas.
Styles & Materials: Garage
Garage Vehicle Door Type:
Single
Number of Vehicle Doors:
1
Number of Automatic Openers:
1
Items: Garage
6.0 Garage/Vehicle Doors
Comments: Inspected
Attached Single Car - satisfactory condition at the time of inspection.
6.0 Item 1 (Picture)
6.1 Garage Door Operator
Comments: Inspected
The garage door had a photoelectric sensor installed on the lower edge of the garage door opening that responded satisfactorily to testing .

Photoelectric sensors are devices installed to prevent injury by raising the vehicle door if the sensor detects a person on a position in which they may be injured by the descending door.

6.2 Conventional Doors
Comments: Repair/Replace
(1) Hardware operational.

There is a fire rated door separating the garage from the living areas of the house.

6.2 Item 1 (Picture)
Garage Entry Door
(2) The fire rated door between the living space and the garage failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. Recommend to have corrected by a qualified professional.
6.3 Floors
Comments: Inspected
The garage floor was in satisfactory condition at the time of inspection.
6.3 Item 1 (Picture)
6.4 Walls
Comments: Inspected
Walls are Drywall. The general condition of the walls throughout the garage was satisfactory at the time of inspection. Walls are not fully visible and was limited due to the occupants stored items. Potential for damage that is NOT visible to the inspector. Be sure to check all areas carefully prior to closing.
6.4 Item 1 (Picture)
6.5 Ceiling
Comments: Inspected
6.6 Fire Separation
Comments: Inspected
The walls and ceilings separating the garage from the home living space appeared to meet generally-accepted current standards for fire separations.  However, it is not possible to verify after the sheetrock is finished. Fire separations are designed to resist the spread of a fire which starts in the garage for a certain length of time in order to give the home's occupants adequate time to escape.
6.7 Moisture
Comments: Inspected
No elevated moisture levels were noted on the exposed areas of the garage walls at the time of inspection.
7. Attic
Description
The General Home inspection for the attic typically includes visual examination of the visible and accessible roof structure (framing and sheathing); roof structure ventilation; thermal envelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom vent terminations) and HVAC components (drip pans, ducts, condensate discharge pipes). The inspector does not perform any engineering evaluations and therefore does not calculate or determine the adequacy, sizing, spacing and spanning of the roof structure components (rafters, trusses, sheathing and ceiling beams.)

In accordance with our standards, we do not attempt to enter attics that have less than thirty inches of headroom, are restricted by ducts, or in which the insulation obscures the joists and thereby makes mobility hazardous, in which case we would inspect them as best we can from the access point. When evaluating the type and amount of insulation on the attic floor, we use only generic terms and approximate measurements, and do not sample or test the material for specific identification. Though insulation may conceal water pipes, electrical conduits, junction boxes, exhaust fans, and other components, we do not disturb or move any portion of it.

The inspector does not determine the adequacy of the attic ventilation system, however may make suggestions for improved attic ventilation which are in accordance with modern building practices. The standard approach to attic ventilation in temperate climates is to thermally isolate the attic space from the living space using some type of thermal insulation. The attic is then ventilated using ventilation devices which allow natural air movement to carry away excess heat before it can radiate into the living space, increasing cooling costs and reducing comfort levels, or before heat originating in the living space can create roof problems such as ice damming.

It is common to find moisture stains in the attic space however it can be quite difficult to determine whether or not these stains are active if it has not recently rained prior to the inspection. Active leaks can occur at any time regardless of the age and condition of the roofing. It is advised to monitor the attic during and after rain and snow events to determine if active leaks may be present.
Styles & Materials: Attic
Attic inspected from:
Inside the attic (partial access)
Attic thermal insulation material:
Fiberglass Batt
Insulation depth:
6-8 inches
Roof Structure Ventilation:
Attic ventilation appeared sufficient
Roof structure ventilation device type:
Continuous ridge vent
Soffit vents
Thermostat-controlled fan
Roof Framing Type:
Dimensional lumber
Roof Sheathing Material:
Plywood
 
 
Items: Attic
7.0 Attic Access
Attic is full size.  The attic floor was only partially floored.  As a result, a limited inspection of the attic was performed from the partially floored area.  A full inspection of the attic space was not performed.  Attics can contain material defects or potentially hazardous conditions. The Inspector disclaims responsibility for identifying problems or conditions that would require full attic entry to identify.
7.0 Item 1 (Picture)
7.1 Conventional Roof Framing
Comments: Inspected
A rafter system is installed in the attic cavity to support the roof decking. The visible rafters or truss system appears to be in satisfactory condition.
7.1 Item 1 (Picture)
7.2 Roof Sheathing
Comments: Inspected
The roof decking/sheathing material is plywood sheeting. The visible roof decking appears to be in satisfactory condition.
7.2 Item 1 (Picture)
7.3 Insulation
Comments: Inspected
The attic floor insulation included fiberglass batts and the visible portions appeared sufficient.
7.3 Item 1 (Picture)
7.4 Roof Structure Ventilation
Comments: Inspected
Attic venting appeared to be sufficient.

The approximate rule of thumb is 1.5 sq. ft. of vent area for every 300 sq. feet of attic floor. Half of the ventilation should be at the ridge and the other half at the eaves. Proper ventilation will help to keep the house cooler during warm weather and extend the life of roofing materials. In the winter, it will help reduce the potential for ice dams on the roof and condensation within the attic.

8. Basement
Styles & Materials: Basement
Foundation Configuration:
Unfinished basement
 
 
Items: Basement
8.0 Basement Access
Basement was full size.

Some areas of the basement were not visible due to the occupant's belongings. The Inspector recommends inspection of these portions of the basement by a qualified inspector after access has been provided.

8.0 Item 1 (Picture)
8.1 Walls/Foundation
Comments: Inspected
Walls are concrete block. Visibility and ability to inspect the basement walls in unfinished area was limited due to the occupants stored items and/or furnishings and wall coverings. There is the potential for damage that is NOT visible to the inspector. Be sure to check all areas carefully prior to closing.
8.1 Item 1 (Picture)
8.1 Item 2 (Picture)
8.2 Moisture
Comments: Marginal/Maintenance
In the basement, small amounts of efflorescence was visible at some of the interior surfaces of the foundation walls. Efflorescence is a white, powdery residue left by moisture seeping through the foundation wall and its presence indicates high moisture levels in soil near the foundation. Excessively high moisture levels in soil supporting the foundation can cause various structural problems related to soil movement. This area should be monitored for future signs of moisture intrusion in an effort to identify and correct the source of moisture.
8.2 Item 1 (Picture)
Efflorescence - Front wall
8.2 Item 2 (Picture)
8.3 Main Support Beams
Comments: Inspected
The Main Support Beam was wood.

The main support beam installed appeared to be in satisfactory condition at the time of inspection. The support beam is only partially visible and only the visible area was inspected.
8.3 Item 1 (Picture)
8.4 Posts/Piers & Columns
Comments: Inspected
Support posts are steel.

The visible support posts/columns installed appeared to be in satisfactory condition at the time of inspection. The support posts were only partially visible. Only the visible posts were inspected.

8.4 Item 1 (Picture)
8.5 Floor Structure - Underfloor Beams
Comments: Inspected
The floor structure was constructed using dimensional lumber.
8.5 Item 1 (Picture)
8.6 Basement Floor
Comments: Inspected
The basement floors are concrete and the visible portions appeared in satisfactory condition at the time of inspection.
8.6 Item 1 (Picture)
9. Interior
Description
The General Home Inspection of living space typically includes inspection of the readily visible and accessible areas of walls, floors, cabinets and closets, and the testing of a representative number of windows and doors, switches and outlets. We do not evaluate window treatments, move furnishings or personal property, debris, insulation, lift carpets or rugs, empty closets or cabinets, nor comment on cosmetic deficiencies. The inspector does not enter any area that is dangerous or could adversely affect the health of the inspector or other persons, nor does the inspector perform any procedure that may damage the property or its components.

The General Home Inspection does not include inspection of security, intercom and sound systems; cable communications/wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only.

The inspector does not test for asbestos, radon, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Testing, identifying, or identifying the source of environmental pollutants or odors (including but not limited to lead, mold, allergens, odors from household pets and cigarette smoke) is beyond the scope of a home inspection. We recommend you carefully determine and schedule whatever remedial services may be deemed advisable or necessary before the close of escrow.

We may not comment on cracks that appear around windows and doors, along lines of framing members, or along seams of drywall and plasterboard. These are typically caused by minor movement, such as wood shrinkage, common settling, and seismic activity, and will often reappear if they are not correctly repaired. Such cracks can become the subject of disputes and are therefore best evaluated by a specialist.

The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings or stored goods were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured prior to the end of your inspection deadline.
Styles & Materials: Interior
Walls and Ceilings:
Drywall
Floor Covering Materials:
Carpet
Wood
Window Material:
Wood
Window Glazing:
Double-pane
Window Operation Type:
Casement
Double-hung
Smoke/CO Detectors:
Smoke detector locations appeared adequate
Items: Interior
9.0 Floors
Comments: Inspected
The general condition of the floors throughout the house was satisfactory at the time of inspection. Visibility and ability to inspect the floor was limited due to the floor covering and/or furnishings. There could be potential for damage not visible to the inspector and it is therefore recommended to check all areas carefully prior to closing.
9.0 Item 1 (Picture)
Master Bedroom
9.0 Item 2 (Picture)
Bedroom 2
9.0 Item 3 (Picture)
Dining Room
9.1 Walls
Comments: Inspected
The general condition of the drywall and plaster walls throughout the house was satisfactory at the time of inspection. Visibility and ability to inspect the walls was limited due to the obstruction by personal items and/or furnishings. There could be potential for damage not visible to the inspector and it is therefore recommended to check all areas carefully prior to closing.
9.2 Ceilings
Comments: Inspected
The overall general condition of the ceilings throughout the house was satisfactory at the time of inspection.
9.3 Doors
Comments: Inspected
Overall the doors and door hardware were in satisfactory and operational condition at the time of inspection.
9.4 Windows and Skylights
Comments: Inspected
A representative sample of windows were tested throughout the house and as a general grouping were operational. Some windows were not tested as access was blocked by furniture, belongings, or window coverings. I recommend that these be tested during your final walk through.
9.5 Interior Trim
Comments: Inspected
The overall condition of the interior trim was satisfactory.
9.6 Lighting
Comments: Inspected
A representative sample of lights were tested and were operation during the inspection
9.7 Stairs & Handrails
Comments: Repair/Replace
The handrail at this staircase was loose and not adequately secured to the wall which is a safety hazard should someone fall. Inspector recommends correction by a qualified contractor to ensure the handrail attachment to the wall is secured.
9.7 Item 1 (Picture)
Handrail to 2nd Floor
9.8 Closets
Comments: Inspected
The general condition of the closets throughout the house was satisfactory at the time of inspection. Stored items or occupant’s personal belongings prevented a full inspection. There is potential for damage that is not visible to the inspector. Be sure to check all closet areas carefully prior to closing.
9.9 Misc. Components: Ceiling fans, Doorbells, Detectors, etc.
Comments: Not Inspected
Smoke detector placement appeared to be adequate. Smoke detectors are not tested as part of a general home inspection. The Inspector recommends that all detectors be checked to confirm that they don't need battery replacement.
10. Kitchen and Built-in Appliances
Description
The General Home Inspection of the Kitchen typically includes (limited) operation and visual inspection of the major appliances such as range hood or downdraft (fan, lights, type), built-in dishwasher, built-in microwave, built-in conventional ovens and cooktops (basic functions, anti-tip); Cabinetry exterior and interior; door and drawer; Sink basin condition; supply valves; adequate trap configuration; functional water flow and drainage; disposal. Note: Appliances are operated at the discretion of the Inspector.

Appliances are tested for basic function and are not evaluated for its adequacy of operation and performance nor for the variety of its settings or cycles. Appliances are not moved during the inspection. Appliances older than ten years may exhibit decreased efficiency. Note that the inspector does not remove dishwasher kickplates; provide an estimate of the remaining life of appliances or report on cleanliness of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection. Viewing cabinets below sinks are often obstructed by the owner’s items and/or cabinet liners. This limits the ability for the inspector to view cabinet fully. All non-viewed areas below sinks are disclaimed.

The following items are NOT inspected: warming ovens, griddles, broilers, free-standing appliances, refrigerators, freezers, ice makers, trash-compactors, portable dishwashers, built-in toasters, coffee-makers, can-openers, blenders, instant hot-water dispensers, hot water dispensers, water filters/purifiers, barbecues, grills, or rotisseries, timers, clocks, thermostats, the self-cleaning and cooking capability of ovens, oven lights and concealed or countertop lighting, which is convenient but often installed after the initial construction and not wired to national electrical standards. These items should be considered outside the scope of the inspection. Any comments made regarding these items are as a courtesy only.

Refrigerators are not part of a home inspection and are not inspected. If the refrigerator is included in the sale of the home, it is recommended that you check it for serviceability prior to the expiration of your Inspection Objection Deadline.
Styles & Materials: Kitchen and Built-in Appliances
Cabinets:
Solid Wood
Countertop Material:
Granite
Range:
Gas
Range/Oven Brand:
General Electric
Range Hood:
Vents to exterior
Range Hood Brand:
Broan
Dishwasher:
Present, Inspected, Not all cycles tested
Dishwasher brand:
General Electric
Dishwasher Anti-siphon method:
High-loop installed
Items: Kitchen and Built-in Appliances
10.0 Range
Comments: Inspected
The range was operational at the time of inspection.

The back of the oven was not visible for inspection. The inspector could not determine if an anti-tip bracket is installed on the rear of the oven. Have further evaluated by a qualified appliance technician and have an anti-tip bracket installed as needed to prevent the oven from tipping forward should the door be loaded while open.

10.0 Item 1 (Picture)
10.1 Cabinets & Counters
Comments: Inspected
Cabinets and counters appeared in satisfactory condition at the time of inspection.
10.1 Item 1 (Picture)
10.2 Range Hood
Comments: Inspected
The exhaust vent of the range hood discharged exhaust to the home exterior.
10.2 Item 1 (Picture)
10.3 Kitchen Sink
Comments: Inspected
The kitchen sink was operational at the time of inspection.
10.3 Item 1 (Picture)
10.3 Item 2 (Picture)
10.4 Dishwasher
Comments: Inspected
The dishwasher unit was operational at the time of inspection. The unit was NOT tested in the various different cycles.  Be sure to operate the dishwasher again prior to closing.
10.4 Item 1 (Picture)
11. Bathrooms
Description
The General Home Inspection of the bathrooms typically includes the following: walls, floors and ceiling; sink (basin, faucet); cabinets (exteriors, doors, drawers, undersink); toilet/bidet tub and shower (faucets, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation.

The home inspection does not include inspection/evaluation of window coverings, overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, bidets and steam showers. Any comments made regarding these items are as a courtesy only.

In accordance with the Standards of Practice, the inspector will not comment on simple cosmetic deficiencies. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, etc. due to the potential for these valves leaking or breaking when operated.

All bathrooms should have some type of ventilation in the form of either an exhaust vent or window. This is to remove the damp/moist air from bathing activities to the exterior of the home. While the home inspector will determine if a window or vent is present/operable in each bathroom, he is not able to determine whether the exhaust fan is correctly terminated to the home exterior. This is because vent piping is concealed behind the walls/ceiling and cannot be observed.

The inspector does not perform leak-testing of shower pans or tub/shower enclosures or determine if they are water-tight. The inspector will comment on obvious leakage when fixtures are operated at the time of the inspection.
Styles & Materials: Bathrooms
Ventilation Method:
Fan/Heat/Light
 
 
Items: Bathrooms
11.0 Sink(s) & Cabinetry
Comments: Inspected, Repair/Replace
(1) The bathroom sink(s) between the bedrooms were operational at the time of inspection.
11.0 Item 1 (Picture)
Bathroom between bedrooms
11.0 Item 2 (Picture)
Left Undersink
11.0 Item 3 (Picture)
Right Undersink
(2) A trap beneath a sink the the master bathroom was of a type called an "S-trap". S-traps are no longer allowed to be installed in new construction for safety reasons. A siphon can develop which empties the trap of water; a condition with the potential to allow toxic sewer gas to enter the living space. Although this type of trap may have been commonly considered safe at the time the home was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. The Inspector recommends replacement of all such traps in the home by a qualified plumbing contractor.
11.0 Item 4 (Picture)
Master Bath
11.0 Item 5 (Picture)
Master Bath Undersink - S-Trap
11.0 Item 6 (Picture)
11.0 Item 7 (Picture)
Illegal Traps
(3) The half bath sink was operational at the time of inspection.
11.0 Item 8 (Picture)
Half-Bath
11.0 Item 9 (Picture)
Half-Bath Undersink
11.1 Toilet
Comments: Inspected
The toilets were operational at the time of inspection
11.2 Shower
Comments: Inspected
Bathroom shower fixtures were operational at the time of inspection.
11.2 Item 1 (Picture)
Shower - Master bath
11.2 Item 2 (Picture)
Shower between bedrooms
11.3 Bathtub
Comments: Inspected
Bathroom tub fixtures were operational at the time of inspection.


HYDROSPA: Hydro-spa was functional at the time of inspection. Note - Its supply pipes should be periodically flushed with anti-bacterial cleanser.
11.3 Item 1 (Picture)
Master bath - Hydrospa
11.3 Item 2 (Picture)
Tub between bedrooms
11.4 Ventilation
Comments: Inspected
The exhaust vent in each bathroom was operational and vented to the exterior at the time of inspection.
12. Electrical
Description
Home electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Full and accurate inspection of electrical systems requires electrical contractor-level experience. For this reason, full inspection of home electrical systems lies beyond the scope of the General Home Inspection.

The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Inspection of the home electrical system typically includes visual inspection of the following: service drop and entrance conductors; service mast and weatherhead; electric meter exterior; service panel and sub-panels; service and equipment grounding; system and component bonding; and visible branch wiring: and a representative number of receptacles and switches as per the NJ Standards of Practice.

Any ancillary wiring or system that is not part of the primary electrical distribution system is not part of this inspection but may be mentioned as a courtesy or for informational purposes only. Examples of these include generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring, underground utilities and systems, low voltage systems, security system devices, heat detectors, carbon monoxide detectors, telephone, security, cable TV, intercoms, and built-in vacuum equipment. Peripheral (yard, pool, low voltage, etc.) exterior lighting not attached to the home is not inspected/tested. Any lights/fixtures on sensors or timers are also outside the scope of the inspection.

Receptacles that are not of standard 110-volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality, power source and placement of smoke and carbon monoxide detectors is not determined as part of this inspection. Note solid conductor aluminum branch wiring requires periodic inspection and maintenance by a licensed electrician.

The current version of the National Electrical Code (NEC) requires that nearly all branch circuits in the interior of the home are equipped with arc fault circuit interrupters (AFCI). This code requirement applies to new homes and renovations and is not part of the home inspection. The purpose of an AFCI is to detect arc faults (loose wires/connections) in electrical circuits that could cause a fire. For improved safety, it is suggested to have AFCI protection installed on the branch circuits. Any accessible AFCI outlets that are tested during a home inspection are only tested for serviceability not AFCI ability.

Conditions indicating the need for a more comprehensive inspection will be referred to a qualified electrical contractor.
Styles & Materials: Electrical
Electrical Service Conductors::
Overhead service
Service Panel Type::
Main breaker load center
Service Panel Manufacturer:
Crouse-Hinds
Service Disconnect Location:
At Service Panel
Service Disconnect Type:
Breakers
Service Disconnect Ampacity:
200 amps
Branch Wiring Methods:
Non-metallic cable
Branch Wiring Conductors:
Solid Copper
 
Items: Electrical
12.0 Service Drop, Drip Loop, Splice and Attachment
Comments: Inspected
The electrical service was overhead.
12.0 Item 1 (Picture)
12.1 Electric Meter
Comments: Inspected, Marginal/Maintenance
(1) The electric meter was located at the left side front of the home.
12.1 Item 1 (Picture)
(2) The electrical meter tag/seal has been cut. The penalties for cutting a security tag on the electric meter vary depending on the utility service provider and local laws. The penalties can range from fines all the way up to misdemeanor charges. I recommend notifying the utility company that the tag has been cut and is in need of replacement.
12.1 Item 2 (Picture)
Cut Tag
12.2 Service Grounding & Bonding
Comments: Inspected
Although a grounding electrode conductor was visible that disappeared into the ground, no grounding electrode was visible. Confirmation of the presence of a proper service grounding electrode would require the services of a qualified electrical contactor.
12.2 Item 1 (Picture)
12.2 Item 2 (Picture)
12.3 Main Panel Location
Main Panel Located in Front Right Corner of Basement
12.3 Item 1 (Picture)
12.4 Service Entrance Conductors
Comments: Inspected
Main Service Entrance Conductors are Stranded Aluminum.
12.4 Item 1 (Picture)
12.5 Service Panel Cabinet and Cover
Comments: Inspected
Panel is Crouse-Hinds 200AMP
12.6 Service Panel Wiring
Comments: Repair/Replace
(1) The service panel wiring was copper and appeared serviceable and correctly sized at the time of inspection.
12.6 Item 1 (Picture)
(2) Buss bar set screws are only rated for two (2) ground wires or one (1) neutral wire under each screw. The buss bar set screws had more wire than it was rated for. Having more wires that the set screw is rated for may result in a poor connection and/or excessive heat. Recommend correction by a licensed electrician.
12.6 Item 2 (Picture)
12.7 Service Disconnect
Comments: Inspected
Main shut off located at top of electric panel.
12.7 Item 1 (Picture)
12.8 Switches
Comments: Inspected
A representative sample of switches was tested. In general, the switches throughout the house were in serviceable condition. Stored items prevent access and testing at some switches.
12.9 Electrical Receptacles (interior)
Comments: Inspected
A representative sample of receptacles was tested. In general, the receptacles throughout the house were in serviceable condition. Stored items prevent access and testing at some switches.
12.10 Electrical Receptacles (exterior)
Comments: Inspected
12.11 GFCI/AFCI Electrical Receptacles
Comments: Repair/Replace
The exterior outlet/receptacle in the front left corner of the house was not GFCI (ground fault circuit interrupter) protected.

Although GFCI protection may not have been required at the time the home was built, for safety reasons, the Inspector recommends that this receptacle be updated to a GFCI receptacle by a licensed electrician.

Note - GFCI protected receptacles provide protection from electric shock and or electrocution hazards in areas prone or susceptible to moisture.  Therefore electrical receptacles located in basements, crawlspaces, garages, the home exterior, and interior receptacles located within 6 feet of a plumbing fixture should be provided with GFCI protection.
12.11 Item 1 (Picture)
Exterior Outlet Front Left Corner
12.12 Visible Branch Wiring
Comments: Inspected
12.13 Junction Boxes
Comments: Repair/Replace
Switch cover plates were missing in various rooms in the home. This condition left energized electrical components exposed to touch, a shock/electrocution hazard. The Inspector recommends that listed cover plates be installed by a qualified electrical contractor.
12.13 Item 1 (Picture)
Basment Ceiling Near Furnace
12.13 Item 2 (Picture)
Attic Floor
12.14 Exterior Wiring
Comments: Repair/Replace
Both exposed wiring and electrical wiring not rated for exterior use were used for an exterior application. This condition left energized electrical components exposed to touch and is a potential shock/electrocution hazard. Recommend to have wires corrected and secured by a qualified electrical contractor.
12.14 Item 1 (Picture)
Left Side of Exterior
13. Plumbing
Description
The General Home Inspection of the plumbing system typically includes a visual inspection of the visible and accessible water supply and distribution systems including limited operation of all interior fixtures and faucets checking water flow and drainage. Inspection of the visible drain, waste and vent (DWV) system; water heater; gas system; and sump pump.

Note that the inspector does not operate any water supply or shut-off valves due to the possibility of valves leaking or breaking when operated and does not determine whether water supply and waste disposal systems are public or private. Because most shut-off valves are not operated regularly they are prone to leak when operated. Therefore they should only be used to shut off the water in the event of a leak that could cause damage to surrounding materials.

The General Home Inspection does not include inspection of or evaluation of sewer lines; private/shared wells and related equipment; private sewage disposal systems; overflow drains for tubs and sinks; backflow prevention devices; anti siphon devices, automatic safety controls, hot tubs or spas; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; and catch pan drains. Any comments made regarding these items are as a courtesy only.

The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence of or condition of any underground or above-ground fuel tanks. It is recommended to have the home/property swept for underground tanks by a qualified professional prior to the end of your inspection objection deadline.

The inspector will confirm if the home hot water system is functioning as intended however testing the hot water output temperature would require special tools and is beyond the scope of a general home inspection.

The water pressure within pipes is commonly confused with water volume, but whereas high water volume is good high-water pressure is not. Therefore, a regulator is recommended whenever street pressure exceeds 80 psi. However, regardless of pressure, leaks will occur in any system, and particularly in one with older galvanized pipes, or one in which the regulator fails, and high pressure begins to stress washers and diaphragms within various components. Water pressure testing in not part of a home inspection as this would require special equipment and possible disassembly of the home water supply system.

If an inline water pressure gauge is found during an inspection the home inspector will reference the PSI at the time of inspection (acceptable range is between 40 psi - 80 psi). If one is not found during the inspection the inspector will reference whether in the inspector’s experience the pressure appears adequate or not and if corrective action is needed.

Usually, waste and drainpipe pipe condition is directly related to its age. Older ones are subject to damage through decay and root movement, whereas the more modern ABS ones are virtually impervious to damage, although some rare batches have been alleged to be defective. Older homes with galvanized or cast-iron supply or waste lines can be obstructed and barely working during an inspection but later fail under heavy use. If the water is turned off or not used for periods of time (such as a vacant house waiting for closing), rust or deposits within the piping can further clog the piping system.

Since significant portions of drainpipes are concealed, we can only infer their condition by observing the draw at drains at the time of inspection. Nonetheless, blockages will still occur in the life of any system.

Styles & Materials: Plumbing
Water Supply Source:
Public Water Supply
Drain Waste and Vent Pipe Materials:
PVC plastic
Cast Iron
Copper
Number of Water Heaters:
1
Water Heater Manufacturer:
Bradford White
Date of Manufacture:
2021
Water Heater Fuel Type:
Gas
Water Heater Type:
Tank (conventional)
Water Heater Tank Capacity:
75 gallons
Type of Gas:
Natural Gas
Items: Plumbing
13.0 Main Water Line Shutoff, Condition & Pressure
Comments: Inspected
(1) Water meter and main shut off are located in the front corner of the basement.
13.0 Item 1 (Picture)
Water shut-off - Main
(2) The main water line material was black polyethylene pipe (PE Pipe). No active leakage is noted at this time. Monitor in the future. Water pressure appears adequate.
13.0 Item 2 (Picture)
Main Supply Line
13.1 Supply Lines
Comments: Inspected
Supply lines were predominantly copper.

Most supply pipes were not visible due to wall, ceiling and floor coverings. Visible pipes only were inspected. No leakage was noted, but monitor in the future.

13.2 DWV - Drain, Waste, & Vent Systems
Comments: Inspected, Repair/Replace
(1) The visible drain, waste and vent (DWV) pipes were copper, galvanized steel, and CPVC.
13.2 Item 1 (Picture)
Copper & Cast Iron
13.2 Item 2 (Picture)
White PVC
(2) Surface rust/corrosion was noted. It appears to be from a current/prior leak above the floor which was inaccessible to the inspector. The Inspector recommends to have a licensed plumber ensure there is no leak and/or replace the corroded piping.
13.2 Item 3 (Picture)
Corrosion
13.3 Exterior Plumbing
Comments: Inspected
(1) Outdoor hose bibs located at the right rear of the house were operated and appear serviceable.

These are exterior hot & cold hose bibs and are not the "frost-free type". Therefore, it is advised to turn off the interior shutoff valves for the exterior hose bibs during the winter season to help reduce the potential for freezing and damage to the hose bibs and piping. If no interior shutoffs are provided then it is recommended to have shutoff valves installed by a qualified professional.
13.3 Item 1 (Picture)
Rear right Side of House - Hot/Cold
(2) A "frost-free" hose bib near the left front side of the home was operable and appeared serviceable. 
13.3 Item 2 (Picture)
Frost-Free Spicket
13.4 Gas Water Heater
Comments: Inspected, Repair/Replace
(1) The water heater is a 75 gallon Bradford-White conventional tank located in the basement.

The water heater was equipped with a Temperature Pressure Relief Valve (TPR) which was not tested. A water shutoff valve is installed.
13.4 Item 1 (Picture)
Water Heater
(2) The year of manufacture for this water heater appeared to be 2021.
13.4 Item 2 (Picture)
Data Plate
(3) The installed vent pipe "Y" was not approved for this purpose. Gaps were also noted. This condition has the potential to allow the toxic products of combustion to enter the living space. The Inspector recommends immediate replacement by a qualified HVAC contractor.
13.4 Item 3 (Picture)
Y Vent
13.4 Item 4 (Picture)
Y Vent Gaps
13.5 Laundry
Comments: Not Inspected
There is a connection box installed in the wall with both hot and cold water and a drain pipe. The drain pipe was not flood tested.

Shut-off valves are not tested for operation during the inspection.

NOTE -  most shut-off valves are not operated regularly and as such they are prone to leak when operated. Shut-off valves should only be used to shut off the water in the event of a leak that could damage surrounding materials.
13.5 Item 1 (Picture)
Laundry Shut-offs
14. Heating
Description
The General Home Inspection of heating systems is limited to basic evaluation based on visual examination and operation using normal operating controls. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation of adequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinet condition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; and temperature/pressure relief valve and discharge pipe (presence, condition, and configuration).

The inspector can only readily open access panels provided by the manufacturer or installer for routine homeowner maintenance and will not operate components when weather conditions or other circumstances apply that may cause equipment damage.

The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only.

Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "livable" rooms (e.g. bedrooms, kitchens and living/dining rooms). It should also be noted that it is beyond the scope of this inspection to determine the heating temperature or air drop range.

Note that the inspector does not provide an estimate of remaining life on heating system components; does not determine if heating systems are appropriately sized, or if air distribution through the building is adequate/efficient; or perform any evaluations that require a pilot light or solid fuel source to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman' s or oil emergency switch to be operated.

The inspector is not equipped to inspect furnace heat exchangers (the majority of which is concealed) for evidence of cracks or holes, or inspect concealed portions of evaporator and condensing coils, heat exchanger or firebox, electronic air filters, humidifiers and de-humidifiers, ducts and in-line duct motors or dampers, as this can only be done by dismantling the unit.

We do NOT determine the presence or condition of underground fuel storage tanks. The inspector will attempt to identify evidence of an underground tank, but in many cases visible evidence is concealed or unavailable. An underground fuel storage tank sweep/search, performed by a qualified environmental contractor, is recommended prior to the expiration of your inspection objection deadline.

Interior of flues/vent piping are not part of a General Home Inspection and are not inspected. It is recommended to have a full NFPA Level 2 inspection (i.e. camera scan of entire length of the flue) prior to use of your fireplace for the first time by a qualified chimney sweep. Please note that only the visible exterior portions of flue/vent piping are inspected.

Observed heating system indications where further evaluation is needed will result in referral to a qualified HVAC contractor. Please note that even modern heating systems can produce carbon monoxide, which in a poorly ventilated room can result in sickness and even death. Therefore, it is essential that any recommendations we make for service or further evaluation be scheduled before the close of escrow.

The general home inspection does not include any type of heating system warranty or guarantee. Normal service and maintenance should be performed on a yearly basis and it is recommended that you obtain an annual heating and cooling service maintenance plan.
Styles & Materials: Heating
Heating System Type:
Gas-fired Furnace (medium efficiency)
Heating System Brand:
Carrier
Fuel Type:
Natural gas
Number of Heat Systems (excluding wood):
One
Date of Manufacture:
2012
 
Items: Heating
14.0 Fuel Supply
Comments: Repair/Replace
The gas meter on the exterior front of the house was located too close to grade. The grade should be 6" below base of meter to prevent premature aging of the meter. The inspector recommends having grade lowered to at least 6" below base of meter by a qualified professional.

Should lowering the grade create surface runoff that drains towards the foundation a window well should be installed around the meter. This excavation will ensure that runoff is kept away from the meter and foundation.
14.0 Item 1 (Picture)
Gas Meter
14.1 Furnace
Comments: Inspected
(1) The furnace is a Carrier and is forced air heat.
14.1 Item 1 (Picture)
Furnace
(2) The unit was manufactured in 2012.
14.1 Item 2 (Picture)
Furnace Data Plate
14.2 Burners/Heat Exchangers
Comments: Inspected
Operational and in satisfactory condition at the time of inspection.
14.2 Item 1 (Picture)
Furnace Burners
14.3 Flues, Vents, Plenum
Comments: Inspected
The flue/vent pipe is metal.
14.3 Item 1 (Picture)
Furnace Flue Vent
14.4 General Operation and Cabinet
Comments: Inspected
Unit was operational at the time of inspection. This does not guarantee future performance, operation, or condition.
14.4 Item 1 (Picture)
14.5 Ducts - Air Supply - Baseboard
Comments: Inspected
The visible air supply ducts appeared to be in serviceable condition at the time of the inspection.
14.6 Air Filters
Comments: Inspected
The air filter for this furnace was located a side compartment at the furnace. Access was through the furnace front. Shut off the furnace at the electrical switch before attempting any service such as filter replacement. The air filter should be checked quarterly and replaced when dirty.
14.6 Item 1 (Picture)
Air filter
14.7 Thermostat
Comments: Inspected
The thermostat is located in the front dining room.
14.7 Item 1 (Picture)
14.8 Fireplace
Comments: Inspected, Repair/Replace
(1) The home contained a wood-burning fireplace located in the living room.

There is a set of glass doors installed. Used correctly, these will help minimize heat loss when the fireplace is not in use. They also eliminate burning embers from flying into the room during a fire and reduce the volume of room air sucked up the chimney.

Damper - Operable
14.8 Item 1 (Picture)
(2) The exhaust flue of the wood-burning fireplace appeared to need cleaning. Dirty flues are potential fire hazards. The flue should be cleaned by a qualified contractor prior to first time use.
14.8 Item 2 (Picture)
15. Cooling
Description
The General Home Inspection of home cooling systems typically includes visual examination of readily observable components for adequate condition, and system testing for proper operation using normal operating controls. Report comments are limited to identification of common requirements and deficiencies. Observed indications requiring further evaluation will be referred to a qualified HVAC professional.

The home inspection does not include an evaluation of the capacity/adequacy of the HVAC system to cool the home, the cooling temperature or air drop range, or the cost of operation. The inspection does not include inspection/evaluation of units that are not permanently installed/hard-wired; electronic air filters; thermostat or temperature control calibration, accuracy and timed functions; components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only.

Note that the inspector does not perform pressure tests on coolant systems, and therefore no representation is made regarding coolant charge or line integrity. The inspector does not provide an estimate of remaining life on cooling system components or operate shut-off valves, circuit breakers needing to be turned "on" or a serviceman' s switches to be operated. Equipment access panels not intended for routine homeowner maintenance are NOT removed during a home inspection.

Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. It should also be noted that condensation lines are often concealed in walls and ceilings and not fully visible to allow verification of termination points. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a cooling source is present in all "livable" rooms (e.g. bedrooms, kitchens and living/dining rooms).

To avoid equipment damage, central air conditioners are only operated and tested when the ambient temperature is above 65 degrees, and the power to the unit has been turned on 24 hours prior to the inspection. Condition of the evaporator coil in the plenum is beyond the scope of a visual inspection.

The general home inspection does not include any type of cooling system warranty or guarantee. Normal service and maintenance should be performed on a yearly basis and it is recommended that you obtain an annual heating and cooling service maintenance plan.
Styles & Materials: Cooling
Number of cooling systems (excluding window AC):
One
Cooling System Type:
Split System (indoor and outdoor components
Cooling Equipment Energy Source:
Electricity
Condenser Manufacturer:
Trane
Condenser: Year of Manufacture:
2017
 
Items: Cooling
15.0 Condenser unit
Comments: Not Inspected
(1) Due to temperature limitations, the central air condition system was unable to be tested.  To safely operate and test a home central air condition system, the outside temperature needs to be 65 degrees or above for 24 hours. If the unit is operated below 65 degrees Fahrenheit, it would risk damaging the coils. A visual inspection was done of the exterior of the condenser unit and any deficiencies found will be noted in this report.

AC Condenser cabinets of this type typically have a service life of 12-15 years. As a condenser cabinet nears 10 years of age, it has an increased likelihood of breakdown in the future. Keep in mind that life expectancies vary dramatically based on installation, location, usage, efficiency, and more.
15.0 Item 1 (Picture)
Condenser Unit - Left Side of House
(2) The unit is a Trane and was manufactured in 2017.
15.0 Item 2 (Picture)
Condenser - Data Plate
15.1 AC Suction Line
Comments: Repair/Replace
The refrigerant suction line for the exterior unit is exposed and needs pipe insulation which can reduce efficiency and cooling.  Recommend to have repaired by a licensed air conditioning contractor.
15.1 Item 1 (Picture)
16. Laundry Room
Description
Laundry appliances are not tested or moved during the inspection and the condition of any piping, walls or flooring hidden by them cannot be judged. The inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for clothes washers due to the possibility of valves leaking or breaking when operated.

The inspector does not determine the completeness or operability of any gas piping to laundry appliances. If the washer and dryer is included in the sale of the home, it is recommended that you check it for serviceability prior to the expiration of your Inspection Objection Deadline.

Dryers and dryer vents are not part of the Home Inspection. The inspector will comment if damage is visible on exposed vent piping. Keep in mind that a visual examination of exposed piping will not detect the presence of lint accumulated inside the vent, which is a potential fire hazard. The Inspector recommends that you have the dryer vent cleaned at the time of purchase and annually in the future to help ensure that safe conditions exist. Lint accumulation can still occur in approved and properly installed vents. Note that the National Fire Protection Association (NFPA) recommends the use of straight metal dryer ducts rather than plastic or flexible metal for safety.
Styles & Materials: Laundry Room
Dryer Power:
Gas
Dryer Gas Supply:
Natural gas
 
Items: Laundry Room
16.0 Location
First floor next to garage.

Clothes washers and dryers are not included as part of a home inspection and are not tested.
16.0 Item 1 (Picture)
Laundry Room
16.1 Dryer Venting
Comments: Not Inspected
Dryers and dryer vents are not part of the Home Inspection, however, the inspector will comment if damage is visible on exposed vent piping.

A visual examination of exposed piping will not detect the presence of lint accumulated inside the vent, which is a potential fire hazard. The Inspector therefore recommends that you have the dryer vent cleaned at the time of purchase and annually in the future to help ensure that safe conditions exist.

CLARITY HOME INSPECTION

55 Winding Lane
Basking Ridge, NJ 07920

Report Attachments

ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.