INSPECTION REPORT
Home Buyer
100 Main Street
New Home NJ 07000
|
INSPECTED BY Christopher Swatt CLARITY HOME INSPECTION |
INSPECTION DATE
![]() ![]() |
INSPECTION REPORT
Home Buyer
100 Main Street
New Home NJ 07000
|
INSPECTED BY Christopher Swatt CLARITY HOME INSPECTION |
INSPECTION DATE
![]() ![]() |
4/2/2021
100 Main Street
New Home NJ 07000
Dear Home Buyer
Attached please find your home inspection report for 100 Main Street performed on 4/2/2021. Thank you for choosing Clarity Home Inspection to perform your home inspection. We understand the emotions and potential anxiety that come with purchasing a home and we strive to ensure that you have a comprehensive understanding of your new home’s condition to help alleviate that.
This inspection report reflects the visual conditions of the property at the time of the inspection only. The inspection was performed in accordance with the NJ Home Inspection Standards of Practice. We recommend you read the entire report.
No warranty is either expressed or implied. This report is not an insurance policy, nor a warranty service.
Some items noted in the attached report should
receive attention, but none of them affect the habitability of the
house. Correction of items resulting from normal wear and tear is
typically considered part of normal home maintenance and
upkeep.
We are always availble to answer any questions you may have
regarding the inspection report or the home, so
please
do not hesitate to contact us at anytime.
Sincerely,
CLARITY HOME INSPECTION
(908) 334-9547
InterNACHI Certified Professional Inspector
NJ Home Inspector License # 24GI00209400
NJ Radon License # MET14329
NJ Wood Destroying Insect License # 62403B
FAA Remote Pilot UAS #
IAC2 – Mold Certified
chris@ClarityHomeInspectionNJ.com
Property Address 100 Main Street New Home NJ 07000 | Date of Inspection 4/2/2021 | Report ID SampleReport - Clarity Home Inspection |
Customer(s) Home Buyer | Time of Inspection 10:00 AM | Real Estate Agent |
Standards of Practice: NJ Standards of Practice | Type of building:: Single Family (2-story) | Approximate Year of Original Construction:: 1950 |
Inspection started at:: 10am | Inspection ended at:: 1pm | Occupancy:: The home was occupied |
Attending the Inspection:: Buyer and Buyer's Agent | Weather during the Inspection:: Clear | Significant precipitation in last 3 days:: No |
Temperature during inspection:: Between 80-90 (F) | Ground/Soil surface condition: Dry | Radon Test: In progress |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Marginal/Maintenance (MM) = Item warrants attention or monitoring or has a limited remaining useful life expectancy and may require replacement in the near term. Further evaluation or servicing may be needed by a qualified licensed contractor or specialty tradesman dealing with that item or system.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = Item, component, or unit is not functioning as intended and needs repair or replacement by a qualified professional. Further evaluation is needed by a qualified licensed contractor or specialty tradesman dealing with that item or system.
55 Winding Lane
Basking Ridge, NJ 07920
Customer
Home Buyer
Address
100 Main Street
New Home NJ 07000
2.1 | Driveway | |
Marginal/Maintenance | ||
2.3 | General Grounds & Grading | |
Repair/Replace | ||
The home had areas of neutral or negative drainage in the front yard that will route runoff from precipitation toward the foundation. Excessively high moisture levels in soil supporting the foundation can cause a wet basement and effect its ability to
support the weight of the structure above. The ground should slope away from the home a minimum of ¼-inch per foot for a distance of at least six feet from the foundation. The Inspector recommends that these areas be re-graded to improve
drainage near the foundation.
Proper re-grading may include the use of swales which are depressions created in the ground that carries/re-routes rainwater by gravity away from your home and property. ![]() 2.3 Item 1 (Picture) Negative grade - Front![]() 2.3 Item 2 (Picture) Swales for drainage |
3.0 | Vinyl Siding | |
Repair/Replace | ||
(1) The exterior cladding (siding) in the back of the house is too close to grade (the ground). All types of exterior cladding should have a minimum of 6" to 8" clearance above the finished grade to prevent damaging water wicking and prevent insect/pest
entry into the wall envelopes. I advise having a qualified professional expose the masonry foundation between the exterior finished grade and the existing wall cladding to the 6”to 8” recommended clearance.
![]() 3.0 Item 1 (Picture) Siding on Rear of House![]() 3.0 Item 2 (Picture) |
||
(2) The vinyl siding on the left of the exterior had areas of cracked or broken siding that should be sealed or replaced to prevent potential damage from moisture intrusion into the home's structure/materials and to prevent development of microbial
growth such as mold. All work should be performed by a qualified contractor.
![]() 3.0 Item 3 (Picture) Damaged Siding |
3.8 | Exterior Foundation - Materials & Condition | |
Repair/Replace | ||
A parge coat was visible at the foundation’s exterior surface. A parge coat is a thin layer of cementitious, plaster-like material applied with a trowel and designed to harden, cover and protect the exterior surface of the foundation wall. Therefore,
visibility and ability to inspect the foundation exterior wall material was not possible and is disclaimed.
Spalling was visible on the exterior surface of the visible exterior concrete/brick walls. Spalling is surface deterioration which causes fragments/flakes of concrete to detach from the surface. The Inspector recommends patching with an appropriate material by a qualified professional to help prevent continued deterioration and possible water infiltration. ![]() 3.8 Item 1 (Picture) Left Rear Corner |
3.10 | Exterior - Other | |
Marginal/Maintenance | ||
On the exterior of the home, the inspector noticed numerous rodent traps which indicates prior/current rodent activity. The Inspector recommends that you contact a pest control contractor to confirm rodent problem has been resolved prior to the
end of your inspection obligation deadline.
![]() 3.10 Item 1 (Picture) |
4.3 | Roof Condition | |
Marginal/Maintenance | ||
(2) Tree branches are overhanging the roof. This will cause lichen and moss to grow which will hold moisture on the roof longer than other areas and will advance wear on the shingles. In freezing climates there may be faster frost damage, cracking,
and wear of the shingles. Branches in contact the roof will accelerate wear due to abrasion(s) and will allow animals to access the roof and possibly the attic. All tree branches touching or overhanging the roof should be trimmed back away from the
home by a qualified professional.
![]() 4.3 Item 3 (Picture) Left Front Roof - Overhanging Branches![]() 4.3 Item 4 (Picture) Lichen/moss - Left Front Roof![]() 4.3 Item 5 (Picture) Front Left Roof |
4.8 | Roof Drainage System - Gutters & Downspouts | |
Repair/Replace | ||
(1) Debris visible in the gutters at the time of the inspection should be removed to encourage proper drainage.
![]() 4.8 Item 1 (Picture) |
||
(2) One or more downspouts discharged roof drainage next to the foundation. This condition can effect the ability of the soil to support the weight of the structure above and can cause damage related to soil/foundation movement. The Inspector
recommends the installation of downspout extensions to discharge roof drainage a minimum of 6 feet from the foundation.
![]() 4.8 Item 2 (Picture) Front Right Corner |
5.0 | Chimney Exterior Condition | |
Repair/Replace | ||
The brick chimney exhibited moderate deterioration such as brick spalling, crumbling, or delamination of the brick face. This is typically caused over the long-term by a combination of moisture absorption, moisture expansion during freezing, and
improper mortar mix design. This deterioration will probably continue unless the problem is identified and corrected. The inspector recommends that you consult with a qualified masonry contractor to discuss options and costs for repair and
stabilization as necessary.
![]() 5.0 Item 1 (Picture) Brick Spalling |
5.2 | Chimney Cap/Crown | |
Repair/Replace | ||
The chimney crown was deteriorated and had several cracks that should be repaired by a qualified professional to avoid continued damage from moisture intrusion and the freeze/thaw cycle.
![]() 5.2 Item 1 (Picture) ![]() 5.2 Item 2 (Picture) Cracking Chimney Crown |
6.2 | Conventional Doors | |
Repair/Replace | ||
(2) The fire rated door between the living space and the garage failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic
fumes. Recommend to have corrected by a qualified professional.
|
8.2 | Moisture | |
Marginal/Maintenance | ||
In the basement, small amounts of efflorescence was visible at some of the interior surfaces of the foundation walls. Efflorescence is a white, powdery residue left by moisture seeping through the foundation wall and its presence indicates high
moisture levels in soil near the foundation. Excessively high moisture levels in soil supporting the foundation can cause various structural problems related to soil movement. This area should be monitored for future signs of moisture intrusion in an
effort to identify and correct the source of moisture.
![]() 8.2 Item 1 (Picture) Efflorescence - Front wall![]() 8.2 Item 2 (Picture) |
9.7 | Stairs & Handrails | |
Repair/Replace | ||
The handrail at this staircase was loose and not adequately secured to the wall which is a safety hazard should someone fall. Inspector recommends correction by a qualified contractor to ensure the handrail attachment to the wall is secured.
![]() 9.7 Item 1 (Picture) Handrail to 2nd Floor |
11.0 | Sink(s) & Cabinetry | |
Inspected, Repair/Replace | ||
(2) A trap beneath a sink the the master bathroom was of a type called an "S-trap". S-traps are no longer allowed to be installed in new construction for safety reasons. A siphon can develop which empties the trap of water; a condition with the
potential to allow toxic sewer gas to enter the living space. Although this type of trap may have been commonly considered safe at the time the home was originally constructed, as general knowledge of safe building practices has improved with the
passage of time, building standards have changed to reflect current understanding. The Inspector recommends replacement of all such traps in the home by a qualified plumbing contractor.
![]() 11.0 Item 4 (Picture) Master Bath![]() 11.0 Item 5 (Picture) Master Bath Undersink - S-Trap![]() 11.0 Item 6 (Picture) ![]() 11.0 Item 7 (Picture) Illegal Traps |
12.1 | Electric Meter | |
Inspected, Marginal/Maintenance | ||
(2) The electrical meter tag/seal has been cut. The penalties for cutting a security tag on the electric meter vary depending on the utility service provider and local laws. The penalties can range from fines all the way up to misdemeanor charges. I
recommend notifying the utility company that the tag has been cut and is in need of replacement.
![]() 12.1 Item 2 (Picture) Cut Tag |
12.6 | Service Panel Wiring | |
Repair/Replace | ||
(2) Buss bar set screws are only rated for two (2) ground wires or one (1) neutral wire under each screw. The buss bar set screws had more wire than it was rated for. Having more wires that the set screw is rated for may result in a poor connection
and/or excessive heat. Recommend correction by a licensed electrician.
![]() 12.6 Item 2 (Picture) |
12.11 | GFCI/AFCI Electrical Receptacles | |
Repair/Replace | ||
The exterior outlet/receptacle in the front left corner of the house was not GFCI (ground fault circuit interrupter) protected.
Although GFCI protection may not have been required at the time the home was built, for safety reasons, the Inspector recommends that this receptacle be updated to a GFCI receptacle by a licensed electrician. Note - GFCI protected receptacles provide protection from electric shock and or electrocution hazards in areas prone or susceptible to moisture. Therefore electrical receptacles located in basements, crawlspaces, garages, the home exterior, and interior receptacles located within 6 feet of a plumbing fixture should be provided with GFCI protection. ![]() 12.11 Item 1 (Picture) Exterior Outlet Front Left Corner |
12.13 | Junction Boxes | |
Repair/Replace | ||
Switch cover plates were missing in various rooms in the home. This condition left energized electrical components exposed to touch, a shock/electrocution hazard. The Inspector recommends that listed cover plates be installed by a qualified
electrical contractor.
![]() 12.13 Item 1 (Picture) Basment Ceiling Near Furnace![]() 12.13 Item 2 (Picture) Attic Floor |
12.14 | Exterior Wiring | |
Repair/Replace | ||
Both exposed wiring and electrical wiring not rated for exterior use were used for an exterior application. This condition left energized electrical components exposed to touch and is a potential shock/electrocution hazard. Recommend to have wires
corrected and secured by a qualified electrical contractor.
![]() 12.14 Item 1 (Picture) Left Side of Exterior |
13.2 | DWV - Drain, Waste, & Vent Systems | |
Inspected, Repair/Replace | ||
(2) Surface rust/corrosion was noted. It appears to be from a current/prior leak above the floor which was inaccessible to the inspector. The Inspector recommends to have a licensed plumber ensure there is no leak and/or replace the corroded piping.
![]() 13.2 Item 3 (Picture) Corrosion |
13.4 | Gas Water Heater | |
Inspected, Repair/Replace | ||
(3) The installed vent pipe "Y" was not approved for this purpose. Gaps were also noted. This condition has the potential to allow the toxic products of combustion to enter the living space. The Inspector recommends immediate replacement by a
qualified HVAC contractor.
![]() 13.4 Item 3 (Picture) Y Vent![]() 13.4 Item 4 (Picture) Y Vent Gaps |
14.0 | Fuel Supply | |
Repair/Replace | ||
The gas meter on the exterior front of the house was located too close to grade. The grade should be 6" below base of meter to prevent premature aging of the meter. The inspector recommends having grade lowered to at least 6" below base of
meter by a qualified professional.
Should lowering the grade create surface runoff that drains towards the foundation a window well should be installed around the meter. This excavation will ensure that runoff is kept away from the meter and foundation. ![]() 14.0 Item 1 (Picture) Gas Meter |
14.8 | Fireplace | |
Inspected, Repair/Replace | ||
(2) The exhaust flue of the wood-burning fireplace appeared to need cleaning. Dirty flues are potential fire hazards. The flue should be cleaned by a qualified contractor prior to first time use.
![]() 14.8 Item 2 (Picture) |
15.1 | AC Suction Line | |
Repair/Replace | ||
The refrigerant suction line for the exterior unit is exposed and needs pipe insulation which can reduce efficiency and cooling. Recommend to have repaired by a licensed air conditioning contractor.
![]() 15.1 Item 1 (Picture) |
120
Items Inspected
Total number in report.
25
Summary Comments
Total number in report.
114
Photos
Total number in report.
Condominium or Town House inspections are partial inspections performed only on those components that the buyer/homeowner is responsible for. It does not include the exterior components of the property, crawlspace, or attic as those components are typically owned by
the association and not owned by the buyer/homeowner. It is up to the buyer to determine if any of these excluded areas are in fact the buyer’s responsibility and if so, to notify the inspector so these areas can be inspected. Please note a different charge will apply should the
buyer want these areas inspected. At times it may not be possible in some cases to inspect attic areas where a duplex unit exists and the buyer is purchasing the lower unit, or vice versa. Our company makes no representation as to the condition of these areas that were not
inspected and are therefore disclaimed. Any areas inspected that are not the responsibility of the buyer/homeowner is for informational purposes only and we assume no liability.
HOME ORIENTATION
All references to orientation throughout the report are as if viewing the home from the front, street side.
1.0 |
Home Inspection Limitations
|
The General Home Inspection is a limited, non-invasive examination limited to the readily accessible and visible systems, equipment and components of the home. The inspector will not dismantle or move any equipment, systems, components,
personal property, furniture, appliances, plants, soil, snow/ice, and or debris in order to conduct the inspection or to expose concealed or inaccessible conditions. Any areas not visible or accessible at the time of inspection cannot and will not be
inspected.
This report is intended only to be a general guide in order to assist the client in making his/her own evaluation as to the overall condition of the home. It is not intended to reflect the value of the premises, nor make any representation as to the advisability of purchase. The inspection is performed in compliance with generally accepted standards of practice, a copy of which is available upon request. The report expresses the personal opinions of the inspector, based upon his visual impressions of the conditions that existed at the time of the inspection only. The General Home Inspection does not include inspection or evaluation of the adequacy or efficiency of insulation or heating and cooling equipment; playground equipment; internal or underground drainage or plumbing; any systems which are shut down or otherwise secured; water wells (water quality and quantity); zoning ordinances; intercoms; security systems; heat sensors; cosmetics or building code conformity. The Inspection does not include inspection for the presence of formaldehyde, lead paint, asbestos, toxic or flammable materials, and other environmental hazards, or pest infestation. Any general comments about these above systems and conditions are informational only and do not represent an inspection. The Client understands that the inspection and report do not, in any way, constitute a guarantee, warranty of merchantability or fitness for a particular purpose, express or implied warranty, or an insurance policy and are not intended to provide any guarantee of the present and/or future adequacy and performance of the property’s structure, systems, or component parts. Any opinions expressed regarding adequacy, capacity, or expected life of components are general estimates based on information about similar components and occasional wide variations are to be expected between such estimates and actual experience. We certify that our inspectors have no interest, present or contemplated, in this property or its improvement and no involvement with trades people or benefits derived from any sales or improvements. To the best of our knowledge and belief, all statements and information in this report are true and correct. Should any disagreement or dispute arise as a result of this inspection or report, it shall be decided by arbitration and shall be submitted for binding, non-appealable arbitration to the American Arbitration Association in accordance with its Construction Industry Arbitration Rules then obtaining, unless the parties mutually agree otherwise. In the event of a claim, the Client will allow the Inspection Company to inspect the claim prior to any repairs or waive the right to make the claim. Client agrees not to disturb or repair or have repaired anything which may constitute evidence relating to the complaint, except in the case of an emergency. Smoke/fire/carbon monoxide detectors (functionality of, power source, placement) are not part of this inspection. If no smoke/fire/carbon monoxide detectors are installed, you should consider installation of battery operated and/or hardwired smoke/fire/carbon monoxide detectors in all recommended locations per the municipality’s requirements. Upon taking occupancy, proper operating and placement of smoke/fire/carbon monoxide detectors should be verified and batteries should be changed. Note that these devices have a limited life span and should be replaced at a minimum of every 10 years. |
2.0 |
Exterior View - Aerial
|
![]() 2.0 Item 1 (Picture) Aerial Property View |
2.1 |
Driveway
Comments: |
The home had an asphalt driveway.
Common cracks (one-quarter inch or less) were visible in the driveway. Cracks exceeding one-quarter inch should be filled with an appropriate sealant to avoid continued damage to the driveway surface from freezing moisture. ![]() 2.1 Item 1 (Picture) |
2.2 |
Walkways
Comments: |
The walkway was masonry pavers and appeared in satisfactory condition at the time of inspection.
![]() 2.2 Item 1 (Picture) |
2.3 |
General Grounds & Grading
Comments: |
The home had areas of neutral or negative drainage in the front yard that will route runoff from precipitation toward the foundation. Excessively high moisture levels in soil supporting the foundation can cause a wet basement and effect its ability to
support the weight of the structure above. The ground should slope away from the home a minimum of ¼-inch per foot for a distance of at least six feet from the foundation. The Inspector recommends that these areas be re-graded to improve
drainage near the foundation.
Proper re-grading may include the use of swales which are depressions created in the ground that carries/re-routes rainwater by gravity away from your home and property. ![]() 2.3 Item 1 (Picture) Negative grade - Front![]() 2.3 Item 2 (Picture) Swales for drainage |
2.4 |
Porch/Patio
|
The rear patio was stamped concrete and was in satisfactory condition at the time of inspection.
NOTE – to best preserve and protect stamped concrete it is recommended that it be periodic sealed (every 1-2 years) with a concrete sealer to protect from UV damage, moisture penetration, freeze-thaw conditions, de-icing chemicals, and abrasion. ![]() 2.4 Item 1 (Picture) Rear Patio |
2.5 |
Exterior Stairs
Comments: |
The rear exterior stairs are composite decking and were in satisfactory condition at the time of inspection.
![]() 2.5 Item 1 (Picture) |
3.0 |
Vinyl Siding
Comments: |
(1) The exterior cladding (siding) in the back of the house is too close to grade (the ground). All types of exterior cladding should have a minimum of 6" to 8" clearance above the finished grade to prevent damaging water wicking and prevent insect/pest
entry into the wall envelopes. I advise having a qualified professional expose the masonry foundation between the exterior finished grade and the existing wall cladding to the 6”to 8” recommended clearance.
![]() 3.0 Item 1 (Picture) Siding on Rear of House![]() 3.0 Item 2 (Picture) |
|
(2) The vinyl siding on the left of the exterior had areas of cracked or broken siding that should be sealed or replaced to prevent potential damage from moisture intrusion into the home's structure/materials and to prevent development of microbial
growth such as mold. All work should be performed by a qualified contractor.
![]() 3.0 Item 3 (Picture) Damaged Siding |
3.1 |
Exterior Doors
Comments: |
3.2 |
Exterior Windows - Type
Comments: |
Predominantly Double Hung/Double Pane
![]() 3.2 Item 1 (Picture) ![]() 3.2 Item 2 (Picture) |
3.3 |
Exterior Windows - Condition
Comments: |
Satisfactory overall, considering age.
|
3.4 |
Window Sills
Comments: |
The window sills appeared satisfactory at the time of inspection.
|
3.5 |
Exterior Trim
Comments: |
The exterior trim appeared satisfactory at the time of inspection.
|
3.6 |
Eaves - Soffits - Fascia
Comments: |
Soffit vents appeared adequate at the time of inspection.
![]() 3.6 Item 1 (Picture) |
3.7 |
Exterior Wall Penetrations
Comments: |
Exterior wall penetrations for were properly sealed to avoid water penetration and or rodent/pest entry.
|
3.8 |
Exterior Foundation - Materials & Condition
Comments: |
A parge coat was visible at the foundation’s exterior surface. A parge coat is a thin layer of cementitious, plaster-like material applied with a trowel and designed to harden, cover and protect the exterior surface of the foundation wall. Therefore,
visibility and ability to inspect the foundation exterior wall material was not possible and is disclaimed.
Spalling was visible on the exterior surface of the visible exterior concrete/brick walls. Spalling is surface deterioration which causes fragments/flakes of concrete to detach from the surface. The Inspector recommends patching with an appropriate material by a qualified professional to help prevent continued deterioration and possible water infiltration. ![]() 3.8 Item 1 (Picture) Left Rear Corner |
3.9 |
Exterior Foundation - Movement
Comments: |
There is no evidence of any recent movement.
|
3.10 |
Exterior - Other
Comments: |
On the exterior of the home, the inspector noticed numerous rodent traps which indicates prior/current rodent activity. The Inspector recommends that you contact a pest control contractor to confirm rodent problem has been resolved prior to the
end of your inspection obligation deadline.
![]() 3.10 Item 1 (Picture) |
4.0 |
Roof Access
|
UAS Remote Aerial Roof Inspection
![]() 4.0 Item 1 (Picture) |
4.1 |
Roof Structure Exterior
Comments: |
4.2 |
Asphalt Shingles
Comments: |
The roof was primarily Dimensional Architectural Asphalt Shingles with a small section of roll roofing in one of the valleys.
![]() 4.2 Item 1 (Picture) ![]() 4.2 Item 2 (Picture) ![]() 4.2 Item 3 (Picture) Roll Roofing |
4.3 |
Roof Condition
Comments: |
(1) There appears to been a recent addition in the rear of the house. The new roofing on the addition is tied into the older roofing of the existing house so there are two different ages of the roofing material. The existing roofing appears to be in fair
condition but past the mid point of it's long term service life.
![]() 4.3 Item 1 (Picture) ![]() 4.3 Item 2 (Picture) |
|
(2) Tree branches are overhanging the roof. This will cause lichen and moss to grow which will hold moisture on the roof longer than other areas and will advance wear on the shingles. In freezing climates there may be faster frost damage, cracking,
and wear of the shingles. Branches in contact the roof will accelerate wear due to abrasion(s) and will allow animals to access the roof and possibly the attic. All tree branches touching or overhanging the roof should be trimmed back away from the
home by a qualified professional.
![]() 4.3 Item 3 (Picture) Left Front Roof - Overhanging Branches![]() 4.3 Item 4 (Picture) Lichen/moss - Left Front Roof![]() 4.3 Item 5 (Picture) Front Left Roof |
4.4 |
Valleys
Comments: |
The valleys appeared to be in satisfactory condition at the time of inspection. The valleys on the roof are closed, using either overlapping or interwoven strip shingles from both intersecting roof lines.
![]() 4.4 Item 1 (Picture) ![]() 4.4 Item 2 (Picture) |
4.5 |
Roof Flashing
Comments: |
The roof flashings appeared in satisfactory condition at the time of inspection.
"Flashing" is the term used to describe sheet metal fabricated into shapes used to protect areas of the roof from moisture intrusion. Typical areas of installation include along headwalls, sidewalls, roof and wall penetrations such as vent pipes,
chimneys, skylights and areas where dissimilar roofing materials or different roof slopes meet. |
4.6 |
Plumbing and Combustion Vents
Comments: |
The plumbing vents were PVC and appeared to be in serviceable condition at the time of inspection.
![]() 4.6 Item 1 (Picture) ![]() 4.6 Item 2 (Picture) |
4.7 |
Roof Ventilation Provisions
Comments: |
Ventilation is provided by ridge vents and soffit vents and appeared in satisfactory condition at the time of inspection
|
4.8 |
Roof Drainage System - Gutters & Downspouts
Comments: |
(1) Debris visible in the gutters at the time of the inspection should be removed to encourage proper drainage.
![]() 4.8 Item 1 (Picture) |
|
(2) One or more downspouts discharged roof drainage next to the foundation. This condition can effect the ability of the soil to support the weight of the structure above and can cause damage related to soil/foundation movement. The Inspector
recommends the installation of downspout extensions to discharge roof drainage a minimum of 6 feet from the foundation.
![]() 4.8 Item 2 (Picture) Front Right Corner |
5.0 |
Chimney Exterior Condition
Comments: |
The brick chimney exhibited moderate deterioration such as brick spalling, crumbling, or delamination of the brick face. This is typically caused over the long-term by a combination of moisture absorption, moisture expansion during freezing, and
improper mortar mix design. This deterioration will probably continue unless the problem is identified and corrected. The inspector recommends that you consult with a qualified masonry contractor to discuss options and costs for repair and
stabilization as necessary.
![]() 5.0 Item 1 (Picture) Brick Spalling |
5.1 |
Chimney Flashing
Comments: |
The installed flashing around the chimney stack appears to be functional and in satisfactory condition.
![]() 5.1 Item 1 (Picture) Chimney Flashing |
5.2 |
Chimney Cap/Crown
Comments: |
The chimney crown was deteriorated and had several cracks that should be repaired by a qualified professional to avoid continued damage from moisture intrusion and the freeze/thaw cycle.
![]() 5.2 Item 1 (Picture) ![]() 5.2 Item 2 (Picture) Cracking Chimney Crown |
5.3 |
Chimney Height & Clearance
Comments: |
The chimney had adequate clearance above the roof surface.
|
6.0 |
Garage/Vehicle Doors
Comments: |
Attached Single Car - satisfactory condition at the time of inspection.
![]() 6.0 Item 1 (Picture) |
6.1 |
Garage Door Operator
Comments: |
The garage door had a photoelectric sensor installed on the lower edge of the garage door opening that responded satisfactorily to testing .
Photoelectric sensors are devices installed to prevent injury by raising the vehicle door if the sensor detects a person on a position in which they may be injured by the descending door. |
6.2 |
Conventional Doors
Comments: |
(1) Hardware operational.
There is a fire rated door separating the garage from the living areas of the house. ![]() 6.2 Item 1 (Picture) Garage Entry Door |
|
(2) The fire rated door between the living space and the garage failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic
fumes. Recommend to have corrected by a qualified professional.
|
6.3 |
Floors
Comments: |
The garage floor was in satisfactory condition at the time of inspection.
![]() 6.3 Item 1 (Picture) |
6.4 |
Walls
Comments: |
Walls are Drywall. The general condition of the walls throughout the garage was satisfactory at the time of inspection. Walls are not fully visible and was limited due to the occupants stored items. Potential for damage that is NOT visible to the
inspector. Be sure to check all areas carefully prior to closing.
![]() 6.4 Item 1 (Picture) |
6.5 |
Ceiling
Comments: |
6.6 |
Fire Separation
Comments: |
The walls and ceilings separating the garage from the home living space appeared to meet generally-accepted current standards for fire separations. However, it is not possible to verify after the sheetrock is finished. Fire separations are designed
to resist the spread of a fire which starts in the garage for a certain length of time in order to give the home's occupants adequate time to escape.
|
6.7 |
Moisture
Comments: |
No elevated moisture levels were noted on the exposed areas of the garage walls at the time of inspection.
|
7.0 |
Attic Access
|
Attic is full size. The attic floor was only partially floored. As a result, a limited inspection of the attic was performed from the partially floored area. A full inspection of the attic space was not performed. Attics can contain material defects or
potentially hazardous conditions. The Inspector disclaims responsibility for identifying problems or conditions that would require full attic entry to identify.
![]() 7.0 Item 1 (Picture) |
7.1 |
Conventional Roof Framing
Comments: |
A rafter system is installed in the attic cavity to support the roof decking. The visible rafters or truss system appears to be in satisfactory condition.
![]() 7.1 Item 1 (Picture) |
7.2 |
Roof Sheathing
Comments: |
The roof decking/sheathing material is plywood sheeting. The visible roof decking appears to be in satisfactory condition.
![]() 7.2 Item 1 (Picture) |
7.3 |
Insulation
Comments: |
The attic floor insulation included fiberglass batts and the visible portions appeared sufficient.
![]() 7.3 Item 1 (Picture) |
7.4 |
Roof Structure Ventilation
Comments: |
Attic venting appeared to be sufficient.
The approximate rule of thumb is 1.5 sq. ft. of vent area for every 300 sq. feet of attic floor. Half of the ventilation should be at the ridge and the other half at the eaves. Proper ventilation will help to keep the house cooler during warm weather and extend the life of roofing materials. In the winter, it will help reduce the potential for ice dams on the roof and condensation within the attic. |
8.0 |
Basement Access
|
Basement was full size.
Some areas of the basement were not visible due to the occupant's belongings. The Inspector recommends inspection of these portions of the basement by a qualified inspector after access has been provided. ![]() 8.0 Item 1 (Picture) |
8.1 |
Walls/Foundation
Comments: |
Walls are concrete block. Visibility and ability to inspect the basement walls in unfinished area was limited due to the occupants stored items and/or furnishings and wall coverings. There is the potential for damage that is NOT visible to the
inspector. Be sure to check all areas carefully prior to closing.
![]() 8.1 Item 1 (Picture) ![]() 8.1 Item 2 (Picture) |
8.2 |
Moisture
Comments: |
In the basement, small amounts of efflorescence was visible at some of the interior surfaces of the foundation walls. Efflorescence is a white, powdery residue left by moisture seeping through the foundation wall and its presence indicates high
moisture levels in soil near the foundation. Excessively high moisture levels in soil supporting the foundation can cause various structural problems related to soil movement. This area should be monitored for future signs of moisture intrusion in an
effort to identify and correct the source of moisture.
![]() 8.2 Item 1 (Picture) Efflorescence - Front wall![]() 8.2 Item 2 (Picture) |
8.3 |
Main Support Beams
Comments: |
The Main Support Beam was wood.
The main support beam installed appeared to be in satisfactory condition at the time of inspection. The support beam is only partially visible and only the visible area was inspected. ![]() 8.3 Item 1 (Picture) |
8.4 |
Posts/Piers & Columns
Comments: |
Support posts are steel.
The visible support posts/columns installed appeared to be in satisfactory condition at the time of inspection. The support posts were only partially visible. Only the visible posts were inspected. ![]() 8.4 Item 1 (Picture) |
8.5 |
Floor Structure - Underfloor Beams
Comments: |
The floor structure was constructed using dimensional lumber.
![]() 8.5 Item 1 (Picture) |
8.6 |
Basement Floor
Comments: |
The basement floors are concrete and the visible portions appeared in satisfactory condition at the time of inspection.
![]() 8.6 Item 1 (Picture) |
9.0 |
Floors
Comments: |
The general condition of the floors throughout the house was satisfactory at the time of inspection. Visibility and ability to inspect the floor was limited due to the floor covering and/or furnishings. There could be potential for damage not visible to the
inspector and it is therefore recommended to check all areas carefully prior to closing.
![]() 9.0 Item 1 (Picture) Master Bedroom![]() 9.0 Item 2 (Picture) Bedroom 2![]() 9.0 Item 3 (Picture) Dining Room |
9.1 |
Walls
Comments: |
The general condition of the drywall and plaster walls throughout the house was satisfactory at the time of inspection. Visibility and ability to inspect the walls was limited due to the obstruction by personal items and/or furnishings. There could be
potential for damage not visible to the inspector and it is therefore recommended to check all areas carefully prior to closing.
|
9.2 |
Ceilings
Comments: |
The overall general condition of the ceilings throughout the house was satisfactory at the time of inspection.
|
9.3 |
Doors
Comments: |
Overall the doors and door hardware were in satisfactory and operational condition at the time of inspection.
|
9.4 |
Windows and Skylights
Comments: |
A representative sample of windows were tested throughout the house and as a general grouping were operational. Some windows were not tested as access was blocked by furniture, belongings, or window coverings. I recommend that these be
tested during your final walk through.
|
9.5 |
Interior Trim
Comments: |
The overall condition of the interior trim was satisfactory.
|
9.6 |
Lighting
Comments: |
A representative sample of lights were tested and were operation during the inspection
|
9.7 |
Stairs & Handrails
Comments: |
The handrail at this staircase was loose and not adequately secured to the wall which is a safety hazard should someone fall. Inspector recommends correction by a qualified contractor to ensure the handrail attachment to the wall is secured.
![]() 9.7 Item 1 (Picture) Handrail to 2nd Floor |
9.8 |
Closets
Comments: |
The general condition of the closets throughout the house was satisfactory at the time of inspection. Stored items or occupant’s personal belongings prevented a full inspection. There is potential for damage that is not visible to the inspector. Be
sure to check all closet areas carefully prior to closing.
|
9.9 |
Misc. Components: Ceiling fans, Doorbells, Detectors, etc.
Comments: |
Smoke detector placement appeared to be adequate. Smoke detectors are not tested as part of a general home inspection. The Inspector recommends that all detectors be checked to confirm that they don't need battery replacement.
|
10.0 |
Range
Comments: |
The range was operational at the time of inspection.
The back of the oven was not visible for inspection. The inspector could not determine if an anti-tip bracket is installed on the rear of the oven. Have further evaluated by a qualified appliance technician and have an anti-tip bracket installed as needed to prevent the oven from tipping forward should the door be loaded while open. ![]() 10.0 Item 1 (Picture) |
10.1 |
Cabinets & Counters
Comments: |
Cabinets and counters appeared in satisfactory condition at the time of inspection.
![]() 10.1 Item 1 (Picture) |
10.2 |
Range Hood
Comments: |
The exhaust vent of the range hood discharged exhaust to the home exterior.
![]() 10.2 Item 1 (Picture) |
10.3 |
Kitchen Sink
Comments: |
The kitchen sink was operational at the time of inspection.
![]() 10.3 Item 1 (Picture) ![]() 10.3 Item 2 (Picture) |
10.4 |
Dishwasher
Comments: |
The dishwasher unit was operational at the time of inspection. The unit was NOT tested in the various different cycles. Be sure to operate the dishwasher again prior to closing.
![]() 10.4 Item 1 (Picture) |
11.0 |
Sink(s) & Cabinetry
Comments: |
(1) The bathroom sink(s) between the bedrooms were operational at the time of inspection.
![]() 11.0 Item 1 (Picture) Bathroom between bedrooms![]() 11.0 Item 2 (Picture) Left Undersink![]() 11.0 Item 3 (Picture) Right Undersink |
|
(2) A trap beneath a sink the the master bathroom was of a type called an "S-trap". S-traps are no longer allowed to be installed in new construction for safety reasons. A siphon can develop which empties the trap of water; a condition with the
potential to allow toxic sewer gas to enter the living space. Although this type of trap may have been commonly considered safe at the time the home was originally constructed, as general knowledge of safe building practices has improved with the
passage of time, building standards have changed to reflect current understanding. The Inspector recommends replacement of all such traps in the home by a qualified plumbing contractor.
![]() 11.0 Item 4 (Picture) Master Bath![]() 11.0 Item 5 (Picture) Master Bath Undersink - S-Trap![]() 11.0 Item 6 (Picture) ![]() 11.0 Item 7 (Picture) Illegal Traps |
|
(3) The half bath sink was operational at the time of inspection.
![]() 11.0 Item 8 (Picture) Half-Bath![]() 11.0 Item 9 (Picture) Half-Bath Undersink |
11.1 |
Toilet
Comments: |
The toilets were operational at the time of inspection
|
11.2 |
Shower
Comments: |
Bathroom shower fixtures were operational at the time of inspection.
![]() 11.2 Item 1 (Picture) Shower - Master bath![]() 11.2 Item 2 (Picture) Shower between bedrooms |
11.3 |
Bathtub
Comments: |
Bathroom tub fixtures were operational at the time of inspection.
HYDROSPA: Hydro-spa was functional at the time of inspection. Note - Its supply pipes should be periodically flushed with anti-bacterial cleanser. ![]() 11.3 Item 1 (Picture) Master bath - Hydrospa![]() 11.3 Item 2 (Picture) Tub between bedrooms |
11.4 |
Ventilation
Comments: |
The exhaust vent in each bathroom was operational and vented to the exterior at the time of inspection.
|
12.0 |
Service Drop, Drip Loop, Splice and Attachment
Comments: |
The electrical service was overhead.
![]() 12.0 Item 1 (Picture) |
12.1 |
Electric Meter
Comments: |
(1) The electric meter was located at the left side front of the home.
![]() 12.1 Item 1 (Picture) |
|
(2) The electrical meter tag/seal has been cut. The penalties for cutting a security tag on the electric meter vary depending on the utility service provider and local laws. The penalties can range from fines all the way up to misdemeanor charges. I
recommend notifying the utility company that the tag has been cut and is in need of replacement.
![]() 12.1 Item 2 (Picture) Cut Tag |
12.2 |
Service Grounding & Bonding
Comments: |
Although a grounding electrode conductor was visible that disappeared into the ground, no grounding electrode was visible. Confirmation of the presence of a proper service grounding electrode would require the services of a qualified electrical
contactor.
![]() 12.2 Item 1 (Picture) ![]() 12.2 Item 2 (Picture) |
12.3 |
Main Panel Location
|
Main Panel Located in Front Right Corner of Basement
![]() 12.3 Item 1 (Picture) |
12.4 |
Service Entrance Conductors
Comments: |
Main Service Entrance Conductors are Stranded Aluminum.
![]() 12.4 Item 1 (Picture) |
12.5 |
Service Panel Cabinet and Cover
Comments: |
Panel is Crouse-Hinds 200AMP
|
12.6 |
Service Panel Wiring
Comments: |
(1) The service panel wiring was copper and appeared serviceable and correctly sized at the time of inspection.
![]() 12.6 Item 1 (Picture) |
|
(2) Buss bar set screws are only rated for two (2) ground wires or one (1) neutral wire under each screw. The buss bar set screws had more wire than it was rated for. Having more wires that the set screw is rated for may result in a poor connection
and/or excessive heat. Recommend correction by a licensed electrician.
![]() 12.6 Item 2 (Picture) |
12.7 |
Service Disconnect
Comments: |
Main shut off located at top of electric panel.
![]() 12.7 Item 1 (Picture) |
12.8 |
Switches
Comments: |
A representative sample of switches was tested. In general, the switches throughout the house were in serviceable condition. Stored items prevent access and testing at some switches.
|
12.9 |
Electrical Receptacles (interior)
Comments: |
A representative sample of receptacles was tested. In general, the receptacles throughout the house were in serviceable condition. Stored items prevent access and testing at some switches.
|
12.10 |
Electrical Receptacles (exterior)
Comments: |
12.11 |
GFCI/AFCI Electrical Receptacles
Comments: |
The exterior outlet/receptacle in the front left corner of the house was not GFCI (ground fault circuit interrupter) protected.
Although GFCI protection may not have been required at the time the home was built, for safety reasons, the Inspector recommends that this receptacle be updated to a GFCI receptacle by a licensed electrician. Note - GFCI protected receptacles provide protection from electric shock and or electrocution hazards in areas prone or susceptible to moisture. Therefore electrical receptacles located in basements, crawlspaces, garages, the home exterior, and interior receptacles located within 6 feet of a plumbing fixture should be provided with GFCI protection. ![]() 12.11 Item 1 (Picture) Exterior Outlet Front Left Corner |
12.12 |
Visible Branch Wiring
Comments: |
12.13 |
Junction Boxes
Comments: |
Switch cover plates were missing in various rooms in the home. This condition left energized electrical components exposed to touch, a shock/electrocution hazard. The Inspector recommends that listed cover plates be installed by a qualified
electrical contractor.
![]() 12.13 Item 1 (Picture) Basment Ceiling Near Furnace![]() 12.13 Item 2 (Picture) Attic Floor |
12.14 |
Exterior Wiring
Comments: |
Both exposed wiring and electrical wiring not rated for exterior use were used for an exterior application. This condition left energized electrical components exposed to touch and is a potential shock/electrocution hazard. Recommend to have wires
corrected and secured by a qualified electrical contractor.
![]() 12.14 Item 1 (Picture) Left Side of Exterior |
The inspector will confirm if the home hot water system is functioning as intended however testing the hot water output temperature would require special tools and is beyond the scope of a general home inspection.
The water pressure within pipes is commonly confused with water volume, but whereas high water volume is good high-water pressure is not. Therefore, a regulator is recommended whenever street pressure exceeds 80 psi. However, regardless of pressure, leaks will occur
in any system, and particularly in one with older galvanized pipes, or one in which the regulator fails, and high pressure begins to stress washers and diaphragms within various components. Water pressure testing in not part of a home inspection as this would require special
equipment and possible disassembly of the home water supply system.
If an inline water pressure gauge is found during an inspection the home inspector will reference the PSI at the time of inspection (acceptable range is between 40 psi - 80 psi). If one is not found during the inspection the inspector will reference whether in the inspector’s
experience the pressure appears adequate or not and if corrective action is needed.
Usually, waste and drainpipe pipe condition is directly related to its age. Older ones are subject to damage through decay and root movement, whereas the more modern ABS ones are virtually impervious to damage, although some rare batches have been alleged to be
defective. Older homes with galvanized or cast-iron supply or waste lines can be obstructed and barely working during an inspection but later fail under heavy use. If the water is turned off or not used for periods of time (such as a vacant house waiting for closing), rust or
deposits within the piping can further clog the piping system.
Since significant portions of drainpipes are concealed, we can only infer their condition by observing the draw at drains at the time of inspection. Nonetheless, blockages will still occur in the life of any system.
13.0 |
Main Water Line Shutoff, Condition & Pressure
Comments: |
(1) Water meter and main shut off are located in the front corner of the basement.
![]() 13.0 Item 1 (Picture) Water shut-off - Main |
|
(2) The main water line material was black polyethylene pipe (PE Pipe). No active leakage is noted at this time. Monitor in the future. Water pressure appears adequate.
![]() 13.0 Item 2 (Picture) Main Supply Line |
13.1 |
Supply Lines
Comments: |
Supply lines were predominantly copper.
Most supply pipes were not visible due to wall, ceiling and floor coverings. Visible pipes only were inspected. No leakage was noted, but monitor in the future. |
13.2 |
DWV - Drain, Waste, & Vent Systems
Comments: |
(1) The visible drain, waste and vent (DWV) pipes were copper, galvanized steel, and CPVC.
![]() 13.2 Item 1 (Picture) Copper & Cast Iron ![]() 13.2 Item 2 (Picture) White PVC |
|
(2) Surface rust/corrosion was noted. It appears to be from a current/prior leak above the floor which was inaccessible to the inspector. The Inspector recommends to have a licensed plumber ensure there is no leak and/or replace the corroded piping.
![]() 13.2 Item 3 (Picture) Corrosion |
13.3 |
Exterior Plumbing
Comments: |
(1) Outdoor hose bibs located at the right rear of the house were operated and appear serviceable.
These are exterior hot & cold hose bibs and are not the "frost-free type". Therefore, it is advised to turn off the interior shutoff valves for the exterior hose bibs during the winter season to help reduce the potential for freezing and damage to the hose bibs and piping. If no interior shutoffs are provided then it is recommended to have shutoff valves installed by a qualified professional. ![]() 13.3 Item 1 (Picture) Rear right Side of House - Hot/Cold |
|
(2) A "frost-free" hose bib near the left front side of the home was operable and appeared serviceable.
![]() 13.3 Item 2 (Picture) Frost-Free Spicket |
13.4 |
Gas Water Heater
Comments: |
(1) The water heater is a 75 gallon Bradford-White conventional tank located in the basement.
The water heater was equipped with a Temperature Pressure Relief Valve (TPR) which was not tested. A water shutoff valve is installed. ![]() 13.4 Item 1 (Picture) Water Heater |
|
(2) The year of manufacture for this water heater appeared to be 2021.
![]() 13.4 Item 2 (Picture) Data Plate |
|
(3) The installed vent pipe "Y" was not approved for this purpose. Gaps were also noted. This condition has the potential to allow the toxic products of combustion to enter the living space. The Inspector recommends immediate replacement by a
qualified HVAC contractor.
![]() 13.4 Item 3 (Picture) Y Vent![]() 13.4 Item 4 (Picture) Y Vent Gaps |
13.5 |
Laundry
Comments: |
There is a connection box installed in the wall with both hot and cold water and a drain pipe. The drain pipe was not flood tested.
Shut-off valves are not tested for operation during the inspection. NOTE - most shut-off valves are not operated regularly and as such they are prone to leak when operated. Shut-off valves should only be used to shut off the water in the event of a leak that could damage surrounding materials. ![]() 13.5 Item 1 (Picture) Laundry Shut-offs |
14.0 |
Fuel Supply
Comments: |
The gas meter on the exterior front of the house was located too close to grade. The grade should be 6" below base of meter to prevent premature aging of the meter. The inspector recommends having grade lowered to at least 6" below base of
meter by a qualified professional.
Should lowering the grade create surface runoff that drains towards the foundation a window well should be installed around the meter. This excavation will ensure that runoff is kept away from the meter and foundation. ![]() 14.0 Item 1 (Picture) Gas Meter |
14.1 |
Furnace
Comments: |
(1) The furnace is a Carrier and is forced air heat.
![]() 14.1 Item 1 (Picture) Furnace |
|
(2) The unit was manufactured in 2012.
![]() 14.1 Item 2 (Picture) Furnace Data Plate |
14.2 |
Burners/Heat Exchangers
Comments: |
Operational and in satisfactory condition at the time of inspection.
![]() 14.2 Item 1 (Picture) Furnace Burners |
14.3 |
Flues, Vents, Plenum
Comments: |
The flue/vent pipe is metal.
![]() 14.3 Item 1 (Picture) Furnace Flue Vent |
14.4 |
General Operation and Cabinet
Comments: |
Unit was operational at the time of inspection. This does not guarantee future performance, operation, or condition.
![]() 14.4 Item 1 (Picture) |
14.5 |
Ducts - Air Supply - Baseboard
Comments: |
The visible air supply ducts appeared to be in serviceable condition at the time of the inspection.
|
14.6 |
Air Filters
Comments: |
The air filter for this furnace was located a side compartment at the furnace. Access was through the furnace front. Shut off the furnace at the electrical switch before attempting any service such as filter replacement. The air filter should be
checked quarterly and replaced when dirty.
![]() 14.6 Item 1 (Picture) Air filter |
14.7 |
Thermostat
Comments: |
The thermostat is located in the front dining room.
![]() 14.7 Item 1 (Picture) |
14.8 |
Fireplace
Comments: |
(1) The home contained a wood-burning fireplace located in the living room.
There is a set of glass doors installed. Used correctly, these will help minimize heat loss when the fireplace is not in use. They also eliminate burning embers from flying into the room during a fire and reduce the volume of room air sucked up the chimney. Damper - Operable ![]() 14.8 Item 1 (Picture) |
|
(2) The exhaust flue of the wood-burning fireplace appeared to need cleaning. Dirty flues are potential fire hazards. The flue should be cleaned by a qualified contractor prior to first time use.
![]() 14.8 Item 2 (Picture) |
15.0 |
Condenser unit
Comments: |
(1) Due to temperature limitations, the central air condition system was unable to be tested. To safely operate and test a home central air condition system, the outside temperature needs to be 65 degrees or above for 24 hours. If the unit is operated
below 65 degrees Fahrenheit, it would risk damaging the coils. A visual inspection was done of the exterior of the condenser unit and any deficiencies found will be noted in this report.
AC Condenser cabinets of this type typically have a service life of 12-15 years. As a condenser cabinet nears 10 years of age, it has an increased likelihood of breakdown in the future. Keep in mind that life expectancies vary dramatically based on installation, location, usage, efficiency, and more. ![]() 15.0 Item 1 (Picture) Condenser Unit - Left Side of House |
|
(2) The unit is a Trane and was manufactured in 2017.
![]() 15.0 Item 2 (Picture) Condenser - Data Plate |
15.1 |
AC Suction Line
Comments: |
The refrigerant suction line for the exterior unit is exposed and needs pipe insulation which can reduce efficiency and cooling. Recommend to have repaired by a licensed air conditioning contractor.
![]() 15.1 Item 1 (Picture) |
16.0 |
Location
|
First floor next to garage.
Clothes washers and dryers are not included as part of a home inspection and are not tested. ![]() 16.0 Item 1 (Picture) Laundry Room |
16.1 |
Dryer Venting
Comments: |
Dryers and dryer vents are not part of the Home Inspection, however, the inspector will comment if damage is visible on exposed vent piping.
A visual examination of exposed piping will not detect the presence of lint accumulated inside the vent, which is a potential fire hazard. The Inspector therefore recommends that you have the dryer vent cleaned at the time of purchase and annually in the future to help ensure that safe conditions exist. |
![]() CLARITY HOME INSPECTION
55 Winding Lane |
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.
Common cracks (one-quarter inch or less) were visible in the driveway. Cracks exceeding one-quarter inch should be filled with an appropriate sealant to avoid continued damage to the driveway surface from freezing moisture.