Date: 1/16/2011 | Time: 09:00 AM | Report ID: 20110116a |
Property: 1234 N Tucson Boulevard Tucson AZ 85701 |
Customer: John Smith |
Real Estate Professional: Mary Sellers Real Estate Pro |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected, Compliant (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI) = I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended.
Not Present (NP) = This item, component or unit is not in this home or building.
MAINTENANCE (M) = This item is in need of maintenance to help prevent damage to components and systems.
HEALTH & SAFETY (HS) = This item has been marked for health and safety concerns, review and repair.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Buyer and their agent | Standards of Practice: Arizona | Type of building: Single Family (1 story) |
Approximate age of building: 1985 | Approximate square footage: 1800 | Home Faces: East |
Temperature: 72 Degrees | Weather: Clear | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Radon Test: No | Water Test: No |
SITE / Planters / Enclosed plant areas: Enclosed Plant Area next to foundation Above Grade with respect to roadway Sandy Soil | Retaining Walls: Retaining Wall part of fence | Fences: Masonry Metal |
DRIVES: concrete | Walks: concrete | Decks / Patios: Covered Patio |
OUTBUILDINGS: None | Irrigation: Irrigation Systems Not Inspected Automatic Irrigation | Fountain or Pond: None |
Bar B Que Equipment: None |
Items
|
1.0 | SITE DRAINAGE Comments: Inspected, Compliant, Maintenance | |
The soil located at the rear yard drain is in need of gravel, rock, vegetation or other soil diversion to prevent further erosion.
Review and repair by a grounds person recommended.
|
1.1 | FAULTY GRADE / VEGETATION Comments: Inspected, Compliant, Maintenance | |
There are tree limbs on the roof that are damaging and need to be trimmed at this time. Have a qualified grounds person trim as
necessary.
|
1.2 | RETAINING WALLS Comments: Inspected, Compliant |
1.3 | FENCES / GATES Comments: Inspected, Compliant |
1.4 | DRIVEWAYS, WALKWAYS, PATIOS (With respect to their effect on the condition of the building) Comments: Inspected, Compliant |
1.5 | IRRIGATION SYSTEM Comments: Inspected, Compliant, Maintenance | |
The irrigation system was not fully inspected but a leak at the main supply was noted, review and repair.
|
1.6 | OUTBUILDINGS / SHEDS Comments: Not Present |
1.7 | BAR B QUE DEVICES Comments: Not Present |
1.8 | FOUNTAINS / PONDS Comments: Not Present |
Roof Type: Flat / Near Flat 4 to 6/12 Common Gable Parapet | Roof Covering: Concrete Tile Built-up Elastomeric Coating | Roof Flashings: Metal Tar |
Viewed roof covering from: Traversed full roof | Sky Light(s): Plastic Curb Mount | Gutters / Roof Drains: None |
Chimney (exterior): Stucco Metal Flue Pipe | Siding Material: Cement stucco | Exterior Entry Doors: Wood Sliding Glass Door(s) Insulated glass |
Windows: Insulated Glass Metal Windows Double Hung Sliders Picture | Decks / Balcony / Porch: None | Garage Door Type: One automatic |
Garage Door Material: Metal |
Items
|
2.0 | ROOF COVERINGS Comments: Inspected, Compliant, Repair or Replace | |
(1) There are several cracked and out of position tiles noted on the main roof, review and repair by a roofing contractor
recommended.
| ||
(2) The built up roofing system on the lower roof is in need of complete flashing and elastomeric coating maintenance. Review by a
roofing contractor recommended for maintenance options.
|
2.1 | FLASHINGS Comments: Inspected, Compliant, Repair or Replace | |
The metal rain cap is loose and needs to be secured on the roof vent to keep rain out. Located over the laundry room, review and
repair.
|
2.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Inspected, Compliant |
2.3 | ROOF DRAINAGE SYSTEMS Comments: Inspected, Compliant |
2.4 | EAVES, SOFFITS AND FASCIAS Comments: Inspected, Compliant, Repair or Replace | |
There is water staining and wood deterioration noted on the back patio roof eave. Review and repair by a roofing contractor
recommended.
|
2.5 | WALL CLADDING FLASHING AND TRIM Comments: Inspected, Compliant, Repair or Replace | |
There are cracks on the top of the stucco parapet wall, these need to be sealed to prevent deterioration of the stucco and
damage to the wall interior, review and repair.
|
2.6 | DOORS (Exterior) Comments: Inspected, Compliant |
2.7 | WINDOWS Comments: Inspected, Compliant |
2.8 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Comments: Not Present |
2.9 | GARAGE VEHICLE DOOR / OPERATORS (Report whether or not doors will reverse when met with resistance) Comments: Inspected, Compliant, Repair or Replace | |
The bottom vehicle door panels are cracked and damaged with some repairs noted. The panels appear to be bowed out and in
need replacement, review by a garage door company recommended.
|
2.10 | CAULKING MAINTENANCE Comments: Inspected, Compliant, Maintenance | |
Caulking maintenance recommended along the top and side edges of the electrical panel to keep water from going behind the
finished siding.
|
Heat Type: Forced Air Automatic safety controls | Energy Source: Natural gas | Number of Heat Systems (excluding wood): One |
Ductwork: Flexduct Insulated | Filter Type: Disposable | Filter Size: 20x30 |
Operable Fireplaces: One | Types of Fireplaces: Site Built Fireplace Wood Burning | Cooling Equipment Type: Electric Air conditioning unit Split System Condenser and Evaporator separate |
Number of AC Only Units: One | Cooling Equipment design: Electricity 4 ton | Temperature differential test: 18 to 22 degrees - good |
Approximate age of equipment: 7 to 9 years | Number of Evaporative Coolers: None |
Items
|
3.0 | GAS/LP FIRELOGS AND FIREPLACES Comments: Not Present |
3.1 | SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) Comments: Inspected, Compliant, Repair or Replace | |
There has been a wood floor installed in front of the fireplace. The area approximately 20 inches in front of the fireplace opening
and extending 12 inches wider than the opening is required to be a non combustible material, review and repair.
|
3.2 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Comments: Inspected, Compliant, Repair or Replace | |
The furnace and water heater vent in not terminated 12 inches above the parapet wall or vertical surface for proper venting as
required when it is within ten feet of that surface, review and repair.
|
3.3 | HEATING EQUIPMENT Comments: Inspected, Compliant |
3.4 | NORMAL OPERATING CONTROLS Comments: Inspected, Compliant |
3.5 | AUTOMATIC SAFETY CONTROLS Comments: Inspected, Compliant |
3.6 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected, Compliant, Repair or Replace | |
(1) The plastic wrap is deteriorated an insulation on the ductwork in the attic area has fallen away from the duct. Review by a hvac
contractor for repair or replacement options recommended.
| ||
(2) There is exposed fiberglass insulation the the return air duct below the furnace. This material should be removed or covered for
proper indoor air quality.
|
3.7 | PRESENCE OF INSTALLED HEAT AND COOL SOURCE IN EACH ROOM Comments: Inspected, Compliant |
3.8 | COOLING AND AIR HANDLER EQUIPMENT Comments: Inspected, Compliant |
3.9 | EVAPORATIVE COOLER Comments: Not Present |
Water Source: Public | Main water source shut off location and size: At the front of the building 1 inch service | Water Heater Location: Garage |
Water Heater Power Source: Gas (quick recovery) | Water Heater Capacity: 40 Gallon | Age of water heater: 11 to 15 years |
Plumbing Waste: ABS | Water Filters: None | Plumbing Water Supply (into home): Copper Not visible |
Plumbing Water Distribution (inside home): Copper Polybutylene | Laundry Facilities: Washer Connections Electric Dryer Connections Dryer vent terminates at roof | Washer Drain Size: 2" Diameter |
Gas Piping: Steel gas piping and fittings | Energy source location: On the right side of the building |
Items
|
4.0 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected, Compliant, Repair or Replace | |
(1) The temperature pressure relief valve on the water heater has a temperature probe designed to go into the tank at a set depth.
There has been a fitting installed on the temperature pressure valve that stops the valve from preforming as designed, review and
repair.
| ||
(2) The water heater combustion air vent is separated and needs to be connected properly and secured with a mechanical fastener.
|
4.1 | GAS OR FUEL STORAGE AND DISTRIBUTION Comments: Inspected, Compliant |
4.2 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected, Compliant |
4.3 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Inspected, Compliant | |
Polybutylene plastic plumbing supply lines (PB) are installed in this home. Polybutylene has been used in this area for many
years from 1978 through 1995 but has had a higher than normal failure rate, and is no longer being widely used. Copper and
Brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further
details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com
|
4.4 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS Comments: Inspected, Compliant, Repair or Replace | |
The plumbing trap located at the garage sink is not the approved smooth wall type and is not installed properly, review and
repair.
|
Electrical Service Conductors: Overhead service | Panel capacity: 200 AMP | Panel Type: Circuit breakers |
Branch wire 15 and 20 AMP: Copper | Wiring Methods: Non Metallic Sheathed Wiring Metal Conduit | Main Electrical Service Location: Located on the right side of the house |
Grounding Method: To re-bar in the footing |
Items
|
5.0 | SERVICE ENTRANCE CONDUCTORS Comments: Inspected, Compliant, Repair or Replace | |
The service conductors are bare where they meet the meter stub, review and repair.
|
5.1 | MAIN AND SUN PANELS Comments: Inspected, Compliant |
5.2 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Inspected, Compliant |
5.3 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected, Compliant |
5.4 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Inspected, Compliant, Repair or Replace | |
(1) The light fixture installed master bath is not rated for damp or wet locations. Review and repair by an electrical contractor
recommended.
| ||
(2) The closet light fixture in the front guest bedroom is the improper type and is missing the globe needed for fire safety, review and
repair.
|
5.5 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected, Compliant, Repair or Replace | |
The metal conduit located main electrical panel is rusted and damaged and needs repair or replacement. Review by an electrical
contractor recommended.
|
5.6 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected, Compliant |
5.7 | ARCH FAULT Comments: Not Present |
5.8 | SMOKE DETECTORS Comments: Inspected, Compliant, Repair or Replace | |
Smoke detectors are now required in all sleeping areas and adjacent rooms. In addition the installation of at least one carbon
monoxide detector is also recommended. The detector at the top of the stairs in inoperative.
|
5.9 | CARBON MONOXIDE DETECTORS Comments: Not Present |
Ceiling Materials: Drywall | Wall Material: Drywall | Floor Covering(s): Ceramic Tile |
Interior Doors: Wood | Windows: Opening Window | Cabinetry: Wood |
Countertop: Cultured marble | Lavatory: Steel enameled self rimming Pop up stopper Under sink valves | Ventillation: Openable window Vent fan |
Shwer/tub surround: Cultured marble Tempered or safety glass door |
Items
|
6.0 | CEILINGS Comments: Inspected, Compliant |
6.1 | WALLS Comments: Inspected, Compliant |
6.2 | FLOORS Comments: Inspected, Compliant |
6.3 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected, Compliant, Repair or Replace | |
The guest bath vanity cabinet has staining and damage from leaks at the lav drain, review and repair. Also see notes for overflow
rusted.
|
6.4 | LAVATORY Comments: Inspected, Compliant, Repair or Replace | |
The over flow piping below the guest bath lav is rusted and the lav is in need of replacement.
|
6.5 | TUB AND SHOWER SURROUND Comments: Inspected, Compliant, Repair or Replace | |
Caulking maintenance is needed around the top of the master shower surround to keep water out causing loosening of the
surround and damaging the wall.
|
6.6 | TUB AND SHOWER DOORS Comments: Inspected, Compliant |
6.7 | TOILET Comments: Inspected, Compliant, Repair or Replace | |
The toilet bowl in the guest bath is cracked and needs replacement.
|
6.8 | TUB SHOWER FAUCET DIVERTER FILLER Comments: Inspected, Compliant |
Ceiling Materials: Drywall | Wall Material: Drywall | Floor Covering(s): Ceramic Tile Carpet |
Interior Doors: Wood Hinged doors Bypass doors | Interior Windows: Weatherstripped |
Items
|
7.0 | CEILINGS Comments: Inspected, Compliant, Repair or Replace | |
Evidence of water intrusion noted on the living room ceiling form a possible roof leak, review and repair.
|
7.1 | GARAGE CEILING / WALLS (INCLUDING FIREWALL SEPARATION) Comments: Inspected, Compliant, Repair or Replace | |
The pull down ladder installed in the garage ceiling breaches the ceiling fire rating. The ladder door needs to be faced with fire
resistant drywall or sheet metal for fire protection, review and repair.
|
7.2 | WALLS Comments: Inspected, Compliant |
7.3 | FLOORS Comments: Inspected, Compliant |
7.4 | GARAGE FLOOR Comments: Inspected, Compliant |
7.5 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected, Compliant, Repair or Replace | |
There is no handrail installed on the upstairs stairway, any stairway with four or more steps should have a safety handrail
installed.
|
7.6 | INTERIOR CABINETS AND COUNTERS Comments: Inspected, Compliant |
7.7 | DOORS (REPRESENTATIVE NUMBER) Comments: Inspected, Compliant, Repair or Replace | |
The threshold is missing in the main entry and there is a gap at the bottom of the door, review and repair.
|
7.8 | FIRE RESISTANT DOOR Comments: Inspected, Compliant |
7.9 | WINDOWS (REPRESENTATIVE NUMBER) Comments: Inspected, Compliant, Repair or Replace | |
There is one broken window lock noted in the living room, review and repair.
|
7.10 | CEILING FANS, CENTRAL VACUUM Comments: Inspected, Compliant |
7.11 | INTERCOMS, ALARMS AND MISC DEVICES Comments: Inspected, Compliant |
Ceiling Materials: Drywall | Wall Material: Drywall | Floor Covering(s): Ceramic Tile |
Cabinetry: Wood | Countertop: Plastic Laminate | Disposer: Installed |
Dishwasher: Installed | Ventilation: Openable window Vented to exterior of building Part of the microwave | Microwave: Installed |
Range/Oven: Free standing range Electric |
Items
|
8.0 | CEILINGS Comments: Inspected, Compliant |
8.1 | WALLS Comments: Inspected, Compliant |
8.2 | FLOORS Comments: Inspected, Compliant |
8.3 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected, Compliant |
8.4 | SINK AND FAUCETS Comments: Inspected, Compliant |
8.5 | FOOD WASTE DISPOSER Comments: Inspected, Compliant, Repair or Replace | |
The electrical connection on the disposal is improper, the connections must be inside the disposal and a box wire clamp
installed.
|
8.6 | DISHWASHER Comments: Inspected, Compliant, Repair or Replace | ||
There is no air gap installed between the dishwasher and the sewer drain connection so a high loop needs to be installed and secured on the dishwasher drain
hose under the kitchen sink to prevent backup of water into the dishwasher. (Note some of the newer upper end models of dishwashers have built in high loops,
review the specifications and installation instructions of this unit if you think a built in loop is included.)
|
8.7 | RANGE HOOD / VENTILATION Comments: Inspected, Compliant |
8.8 | MICROWAVE COOKING EQUIPMENT Comments: Inspected, Compliant, Repair or Replace | |
The microwave turntable platter is missing.
|
8.9 | RANGES/OVENS/COOKTOPS Comments: Inspected, Compliant, Repair or Replace | |
The child safety tip down bracket is not installed on the range, this is a safety device, review and repair.
|
8.10 | REFRIGERATOR Comments: Inspected, Compliant |
Sub area: No sub area | Method used to observe Crawlspace: None | Floor Structure: Post tension slab |
Foundation: Poured concrete | Columns or Piers: Wood column or piers | Floor System Insulation: NONE |
Crawl space ventillation: None | Wall Structure: 2 X 6 Wood | Method used to observe attic: Partially traversed |
Attic access location: located in the master bedroom closet. | Ceiling Structure: Site framed 2X8 | Roof Structure: Engineered wood trusses Site framed |
Roof-Type: Flat or low slope Gable | Attic Insulation: Blown or Loose Fill Fiberglass R-30 or better | Ventilation attic: Gable vents Soffit Vents Passive |
Exhaust Fan piping (kitchen and bath): flexible metal | Dryer Vent: Metal |
Items
|
9.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Inspected, Compliant, Repair or Replace | |
The concrete slab foundation is a post tension type and has steel cables installed in the slab under high tension. There is on
cable that appears to have lost its tension and needs review by a post tension contractor for engineering review and remedies.
|
9.1 | WALLS (Structural) Comments: Inspected, Compliant |
9.2 | COLUMNS OR PIERS Comments: Inspected, Compliant |
9.3 | FLOORS (Structural) Comments: Inspected, Compliant |
9.4 | CEILINGS (structural) Comments: Inspected, Compliant |
9.5 | ROOF STRUCTURE AND ATTIC Comments: Inspected, Compliant |
9.6 | INSULATION IN ATTIC Comments: Inspected, Compliant |
9.7 | INSULATION UNDER FLOOR SYSTEM Comments: Not Present |
9.8 | VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) Comments: Not Present |
9.9 | VENTILATION OF FOUNDATION AREAS Comments: Not Present |
9.10 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Inspected, Compliant, Repair or Replace | |
The guest bath vent fan duct pipe is not installed in the attic from the fan to the outside of the house, review and repair.
|
9.11 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) Comments: Not Present |
9.12 | ATTIC VENTILLATION Comments: Inspected, Compliant |
9.13 | WOOD DETERIORATION Comments: Inspected, Compliant |
9.14 | PEST INSPECTION Comments: Not Inspected | |
There are signs of wood boring pest activity, possibly prior. Obtain and review the wood infestation report for termite activity and
wood deterioration.
|
![]() |
INVOICE |
Abode Inspection Services
P O Box 64127 Tucson, AZ 85728 520-401-0400 Inspected By: Jim Josephson |
Inspection Date: 1/16/2011
Report ID: 20110116a |