Abode Inspection Services
 

Inspection Report

John Smith

Property Address:
1234 N Tucson Boulevard
Tucson AZ 85701

Abode Inspection Services

Jim Josephson AZ License 38082
P O Box 64127
Tucson, AZ 85728
520-401-0400

 

 

Top Table of Contents Bottom
 

Table of Contents

Top Table of Contents Bottom
 
Date: 1/16/2011 Time: 09:00 AM Report ID: 20110116a
Property:
1234 N Tucson Boulevard
Tucson AZ 85701
Customer:
John Smith
Real Estate Professional:
Mary Sellers
Real Estate Pro

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.

Inspected, Compliant (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.

Not Inspected (NI) = I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended.

Not Present (NP) = This item, component or unit is not in this home or building.

MAINTENANCE (M) = This item is in need of maintenance to help prevent damage to components and systems.

HEALTH & SAFETY (HS) = This item has been marked for health and safety concerns, review and repair.

Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.

In Attendance:
Buyer and their agent

Standards of Practice:
Arizona

Type of building:
Single Family (1 story)

Approximate age of building:
1985

Approximate square footage:
1800

Home Faces:
East

Temperature:
72 Degrees

Weather:
Clear

Ground/Soil surface condition:
Dry

Rain in last 3 days:
No

Radon Test:
No

Water Test:
No

Top Table of Contents Bottom
The home inspector shall observe: Decks, stoops, steps, areaways, porches and applicable railings; Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector is not required to observe: Fences; Geological conditions; Soil conditions; grounds lighting systems, irrigation systems, R V hookups, Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. As a courtesy to the client the inspector may include a cursory inspection of items that are not not required inspection items, this does not obligate the inspector to exceed the requirements in other areas.

Styles & Materials
SITE / Planters / Enclosed plant areas:
Enclosed Plant Area next to foundation
Above Grade with respect to roadway
Sandy Soil
Retaining Walls:
Retaining Wall part of fence
Fences:
Masonry
Metal
DRIVES:
concrete
Walks:
concrete
Decks / Patios:
Covered Patio
OUTBUILDINGS:
None
Irrigation:
Irrigation Systems Not Inspected
Automatic Irrigation
Fountain or Pond:
None
Bar B Que Equipment:
None
  
Items
1.0 SITE DRAINAGE
Comments: Inspected, Compliant, Maintenance
The soil located at the rear yard drain is in need of gravel, rock, vegetation or other soil diversion to prevent further erosion. Review and repair by a grounds person recommended.
1.0 Picture 1
1.1 FAULTY GRADE / VEGETATION
Comments: Inspected, Compliant, Maintenance
There are tree limbs on the roof that are damaging and need to be trimmed at this time. Have a qualified grounds person trim as necessary.
1.1 Picture 1
1.2 RETAINING WALLS
Comments: Inspected, Compliant
1.3 FENCES / GATES
Comments: Inspected, Compliant
1.4 DRIVEWAYS, WALKWAYS, PATIOS (With respect to their effect on the condition of the building)
Comments: Inspected, Compliant
1.5 IRRIGATION SYSTEM
Comments: Inspected, Compliant, Maintenance
The irrigation system was not fully inspected but a leak at the main supply was noted, review and repair.
1.5 Picture 1
1.6 OUTBUILDINGS / SHEDS
Comments: Not Present
1.7 BAR B QUE DEVICES
Comments: Not Present
1.8 FOUNTAINS / PONDS
Comments: Not Present
The grounds of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that a qualified contractor be used in your further inspection and repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The home inspector shall observe: Roof covering, roof drainage system, flashings, skylights, roof penetrations, wall cladding, wall flashings, and trim, entryway doors and a representative number of windows, garage door operators, decks, balconies, stoops, steps, eaves, soffits, and fascias. The home inspector shall Describe: Roof covering, wall cladding materials, operate all entryway doors and a representative number of windows, operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Detached buildings or structures. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Roof Type:
Flat / Near Flat
4 to 6/12 Common
Gable
Parapet
Roof Covering:
Concrete Tile
Built-up
Elastomeric Coating
Roof Flashings:
Metal
Tar
Viewed roof covering from:
Traversed full roof
Sky Light(s):
Plastic Curb Mount
Gutters / Roof Drains:
None
Chimney (exterior):
Stucco
Metal Flue Pipe
Siding Material:
Cement stucco
Exterior Entry Doors:
Wood
Sliding Glass Door(s)
Insulated glass
Windows:
Insulated Glass
Metal Windows
Double Hung
Sliders
Picture
Decks / Balcony / Porch:
None
Garage Door Type:
One automatic
Garage Door Material:
Metal
  
Items
2.0 ROOF COVERINGS
Comments: Inspected, Compliant, Repair or Replace
(1) There are several cracked and out of position tiles noted on the main roof, review and repair by a roofing contractor recommended.
2.0 Picture 1
(2) The built up roofing system on the lower roof is in need of complete flashing and elastomeric coating maintenance. Review by a roofing contractor recommended for maintenance options.
2.0 Picture 2
2.1 FLASHINGS
Comments: Inspected, Compliant, Repair or Replace
The metal rain cap is loose and needs to be secured on the roof vent to keep rain out. Located over the laundry room, review and repair. 
2.1 Picture 1
2.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Comments: Inspected, Compliant
2.3 ROOF DRAINAGE SYSTEMS
Comments: Inspected, Compliant
2.4 EAVES, SOFFITS AND FASCIAS
Comments: Inspected, Compliant, Repair or Replace
There is water staining and wood deterioration noted on the back patio roof eave. Review and repair by a roofing contractor recommended.
2.4 Picture 1
2.5 WALL CLADDING FLASHING AND TRIM
Comments: Inspected, Compliant, Repair or Replace
There are cracks on the top of the stucco parapet wall, these need to be sealed to prevent deterioration of the stucco and damage to the wall interior, review and repair.
2.5 Picture 1
2.6 DOORS (Exterior)
Comments: Inspected, Compliant
2.7 WINDOWS
Comments: Inspected, Compliant
2.8 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS
Comments: Not Present
2.9 GARAGE VEHICLE DOOR / OPERATORS (Report whether or not doors will reverse when met with resistance)
Comments: Inspected, Compliant, Repair or Replace
The bottom vehicle door panels are cracked and damaged with some repairs noted. The panels appear to be bowed out and in need replacement, review by a garage door company recommended.
2.9 Picture 1
2.10 CAULKING MAINTENANCE
Comments: Inspected, Compliant, Maintenance
Caulking maintenance recommended along the top and side edges of the electrical panel to keep water from going behind the finished siding.
2.10 Picture 1
The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The home inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to home; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating and cooling equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating or cooling systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Heat Type:
Forced Air
Automatic safety controls
Energy Source:
Natural gas
Number of Heat Systems (excluding wood):
One
Ductwork:
Flexduct
Insulated
Filter Type:
Disposable
Filter Size:
20x30
Operable Fireplaces:
One
Types of Fireplaces:
Site Built Fireplace
Wood Burning
Cooling Equipment Type:
Electric Air conditioning unit
Split System Condenser and Evaporator separate
Number of AC Only Units:
One
Cooling Equipment design:
Electricity
4 ton
Temperature differential test:
18 to 22 degrees - good
Approximate age of equipment:
7 to 9 years
Number of Evaporative Coolers:
None
 
Items
3.0 GAS/LP FIRELOGS AND FIREPLACES
Comments: Not Present
3.1 SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)
Comments: Inspected, Compliant, Repair or Replace
There has been a wood floor installed in front of the fireplace. The area approximately 20 inches in front of the fireplace opening and extending 12 inches wider than the opening is required to be a non combustible material, review and repair.
3.1 Picture 1
3.2 CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems)
Comments: Inspected, Compliant, Repair or Replace
The furnace and water heater vent in not terminated 12 inches above the parapet wall or vertical surface for proper venting as required when it is within ten feet of that surface, review and repair.
3.2 Picture 1
3.3 HEATING EQUIPMENT
Comments: Inspected, Compliant
3.4 NORMAL OPERATING CONTROLS
Comments: Inspected, Compliant
3.5 AUTOMATIC SAFETY CONTROLS
Comments: Inspected, Compliant
3.6 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: Inspected, Compliant, Repair or Replace
(1) The plastic wrap is deteriorated an insulation on the ductwork in the attic area has fallen away from the duct. Review by a hvac contractor for repair or replacement options recommended.
3.6 Picture 1
(2) There is exposed fiberglass insulation the the return air duct below the furnace. This material should be removed or covered for proper indoor air quality.
3.6 Picture 2
3.7 PRESENCE OF INSTALLED HEAT AND COOL SOURCE IN EACH ROOM
Comments: Inspected, Compliant
3.8 COOLING AND AIR HANDLER EQUIPMENT
Comments: Inspected, Compliant
3.9 EVAPORATIVE COOLER
Comments: Not Present
The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush handles, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Water Source:
Public
Main water source shut off location and size:
At the front of the building
1 inch service
Water Heater Location:
Garage
Water Heater Power Source:
Gas (quick recovery)
Water Heater Capacity:
40 Gallon
Age of water heater:
11 to 15 years
Plumbing Waste:
ABS
Water Filters:
None
Plumbing Water Supply (into home):
Copper
Not visible
Plumbing Water Distribution (inside home):
Copper
Polybutylene
Laundry Facilities:
Washer Connections
Electric Dryer Connections
Dryer vent terminates at roof
Washer Drain Size:
2" Diameter
Gas Piping:
Steel gas piping and fittings
Energy source location:
On the right side of the building
 
Items
4.0 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS
Comments: Inspected, Compliant, Repair or Replace
(1) The temperature pressure relief valve on the water heater has a temperature probe designed to go into the tank at a set depth. There has been a fitting installed on the temperature pressure valve that stops the valve from preforming as designed, review and repair.
4.0 Picture 1
(2) The water heater combustion air vent is separated and needs to be connected properly and secured with a mechanical fastener.
4.0 Picture 2
4.1 GAS OR FUEL STORAGE AND DISTRIBUTION
Comments: Inspected, Compliant
4.2 MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments: Inspected, Compliant
4.3 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: Inspected, Compliant
Polybutylene plastic plumbing supply lines (PB) are installed in this home. Polybutylene has been used in this area for many years from 1978 through 1995 but has had a higher than normal failure rate, and is no longer being widely used. Copper and Brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com
4.3 Picture 1
4.4 PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected, Compliant, Repair or Replace
The plumbing trap located at the garage sink is not the approved smooth wall type and is not installed properly, review and repair.
4.4 Picture 1
The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Electrical Service Conductors:
Overhead service
Panel capacity:
200 AMP
Panel Type:
Circuit breakers
Branch wire 15 and 20 AMP:
Copper
Wiring Methods:
Non Metallic Sheathed Wiring
Metal Conduit
Main Electrical Service Location:
Located on the right side of the house
Grounding Method:
To re-bar in the footing
  
Items
5.0 SERVICE ENTRANCE CONDUCTORS
Comments: Inspected, Compliant, Repair or Replace
The service conductors are bare where they meet the meter stub, review and repair.
5.0 Picture 1
5.1 MAIN AND SUN PANELS
Comments: Inspected, Compliant
5.2 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments: Inspected, Compliant
5.3 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments: Inspected, Compliant
5.4 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: Inspected, Compliant, Repair or Replace
(1) The light fixture installed master bath is not rated for damp or wet locations. Review and repair by an electrical contractor recommended.
5.4 Picture 1
(2) The closet light fixture in the front guest bedroom is the improper type and is missing the globe needed for fire safety, review and repair.
5.4 Picture 2
5.5 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments: Inspected, Compliant, Repair or Replace
The metal conduit located main electrical panel is rusted and damaged and needs repair or replacement. Review by an electrical contractor recommended.
5.5 Picture 1
5.6 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments: Inspected, Compliant
5.7 ARCH FAULT
Comments: Not Present
5.8 SMOKE DETECTORS
Comments: Inspected, Compliant, Repair or Replace
Smoke detectors are now required in all sleeping areas and adjacent rooms. In addition the installation of at least one carbon monoxide detector is also recommended. The detector at the top of the stairs in inoperative.
5.8 Picture 1
5.9 CARBON MONOXIDE DETECTORS
Comments: Not Present
The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The home inspector shall observe the bathroom electrical system, plumbing system, doors, walls, ceilings, floors, water handling fixtures and a representative number of windows and cabinet drawers and doors. The inspector shall operate a representative number of doors, windows, cabinet doors and drawers. The electrical deficiencies (if any) are listed in the electrical section. The plumbing deficiencies (if any) are listed in this section or the plumbing section. The inspector shall report water leaks, water damage, significant and material deficiencies or concerns. The home inspector is not required to observe paint, wallpaper, and other finish treatments on interior walls, ceilings, floors, window treatments and accessory hardware. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Ceramic Tile
Interior Doors:
Wood
Windows:
Opening Window
Cabinetry:
Wood
Countertop:
Cultured marble
Lavatory:
Steel enameled
self rimming
Pop up stopper
Under sink valves
Ventillation:
Openable window
Vent fan
Shwer/tub surround:
Cultured marble
Tempered or safety glass door
  
Items
6.0 CEILINGS
Comments: Inspected, Compliant
6.1 WALLS
Comments: Inspected, Compliant
6.2 FLOORS
Comments: Inspected, Compliant
6.3 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments: Inspected, Compliant, Repair or Replace
The guest bath vanity cabinet has staining and damage from leaks at the lav drain, review and repair. Also see notes for overflow rusted.
6.3 Picture 1
6.4 LAVATORY
Comments: Inspected, Compliant, Repair or Replace
The over flow piping below the guest bath lav is rusted and the lav is in need of replacement.
6.4 Picture 1
6.5 TUB AND SHOWER SURROUND
Comments: Inspected, Compliant, Repair or Replace
Caulking maintenance is needed around the top of the master shower surround to keep water out causing loosening of the surround and damaging the wall.
6.5 Picture 1
6.6 TUB AND SHOWER DOORS
Comments: Inspected, Compliant
6.7 TOILET
Comments: Inspected, Compliant, Repair or Replace
The toilet bowl in the guest bath is cracked and needs replacement.
6.7 Picture 1
6.8 TUB SHOWER FAUCET DIVERTER FILLER
Comments: Inspected, Compliant
The bathroom(s) was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving of furnishings or area rugs and areas may be obstructed. Please be aware the inspector has your best interest in mind. Any repair items mentioned should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the inspection report.
Top Table of Contents Bottom
The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and a representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting as to normal wear and tear and damage or any Draperies, blinds, or other window treatments. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Ceramic Tile
Carpet
Interior Doors:
Wood
Hinged doors
Bypass doors
Interior Windows:
Weatherstripped
 
Items
7.0 CEILINGS
Comments: Inspected, Compliant, Repair or Replace
Evidence of water intrusion noted on the living room ceiling form a possible roof leak, review and repair.
7.0 Picture 1
7.1 GARAGE CEILING / WALLS (INCLUDING FIREWALL SEPARATION)
Comments: Inspected, Compliant, Repair or Replace
The pull down ladder installed in the garage ceiling breaches the ceiling fire rating. The ladder door needs to be faced with fire resistant drywall or sheet metal for fire protection, review and repair.
7.1 Picture 1
7.2 WALLS
Comments: Inspected, Compliant
7.3 FLOORS
Comments: Inspected, Compliant
7.4 GARAGE FLOOR
Comments: Inspected, Compliant
7.5 STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments: Inspected, Compliant, Repair or Replace
There is no handrail installed on the upstairs stairway, any stairway with four or more steps should have a safety handrail installed.
7.5 Picture 1
7.6 INTERIOR CABINETS AND COUNTERS
Comments: Inspected, Compliant
7.7 DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected, Compliant, Repair or Replace
The threshold is missing in the main entry and there is a gap at the bottom of the door, review and repair.
7.7 Picture 1
7.8 FIRE RESISTANT DOOR
Comments: Inspected, Compliant
7.9 WINDOWS (REPRESENTATIVE NUMBER)
Comments: Inspected, Compliant, Repair or Replace
There is one broken window lock noted in the living room, review and repair.
7.9 Picture 1
7.10 CEILING FANS, CENTRAL VACUUM
Comments: Inspected, Compliant
7.11 INTERCOMS, ALARMS AND MISC DEVICES
Comments: Inspected, Compliant
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom

Styles & Materials
Ceiling Materials:
Drywall
Wall Material:
Drywall
Floor Covering(s):
Ceramic Tile
Cabinetry:
Wood
Countertop:
Plastic Laminate
Disposer:
Installed
Dishwasher:
Installed
Ventilation:
Openable window
Vented to exterior of building
Part of the microwave
Microwave:
Installed
Range/Oven:
Free standing range
Electric
  
Items
8.0 CEILINGS
Comments: Inspected, Compliant
8.1 WALLS
Comments: Inspected, Compliant
8.2 FLOORS
Comments: Inspected, Compliant
8.3 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments: Inspected, Compliant
8.4 SINK AND FAUCETS
Comments: Inspected, Compliant
8.5 FOOD WASTE DISPOSER
Comments: Inspected, Compliant, Repair or Replace
The electrical connection on the disposal is improper, the connections must be inside the disposal and a box wire clamp installed.
8.5 Picture 1
8.6 DISHWASHER
Comments: Inspected, Compliant, Repair or Replace
There is no air gap installed between the dishwasher and the sewer drain connection so a high loop needs to be installed and secured on the dishwasher drain hose under the kitchen sink to prevent backup of water into the dishwasher. (Note some of the newer upper end models of dishwashers have built in high loops, review the specifications and installation instructions of this unit if you think a built in loop is included.)
8.6 Picture 1
8.6 Picture 2
8.7 RANGE HOOD / VENTILATION
Comments: Inspected, Compliant
8.8 MICROWAVE COOKING EQUIPMENT
Comments: Inspected, Compliant, Repair or Replace
The microwave turntable platter is missing.
8.8 Picture 1
8.9 RANGES/OVENS/COOKTOPS
Comments: Inspected, Compliant, Repair or Replace
The child safety tip down bracket is not installed on the range, this is a safety device, review and repair.
8.9 Picture 1
8.10 REFRIGERATOR
Comments: Inspected, Compliant
The kitchen and built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Top Table of Contents Bottom
The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure and roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is limited or obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons. As a courtesy the home inspector may make comments on non required items, this should not be considered a complete review of this item or obligate to exceed requirements in other areas.

Styles & Materials
Sub area:
No sub area
Method used to observe Crawlspace:
None
Floor Structure:
Post tension slab
Foundation:
Poured concrete
Columns or Piers:
Wood column or piers
Floor System Insulation:
NONE
Crawl space ventillation:
None
Wall Structure:
2 X 6 Wood
Method used to observe attic:
Partially traversed
Attic access location:
located in the master bedroom closet.
Ceiling Structure:
Site framed
2X8
Roof Structure:
Engineered wood trusses
Site framed
Roof-Type:
Flat or low slope
Gable
Attic Insulation:
Blown or Loose Fill
Fiberglass
R-30 or better
Ventilation attic:
Gable vents
Soffit Vents
Passive
Exhaust Fan piping (kitchen and bath):
flexible metal
Dryer Vent:
Metal
 
Items
9.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Comments: Inspected, Compliant, Repair or Replace
The concrete slab foundation is a post tension type and has steel cables installed in the slab under high tension. There is on cable that appears to have lost its tension and needs review by a post tension contractor for engineering review and remedies.
9.0 Picture 1
9.1 WALLS (Structural)
Comments: Inspected, Compliant
9.2 COLUMNS OR PIERS
Comments: Inspected, Compliant
9.3 FLOORS (Structural)
Comments: Inspected, Compliant
9.4 CEILINGS (structural)
Comments: Inspected, Compliant
9.5 ROOF STRUCTURE AND ATTIC
Comments: Inspected, Compliant
9.6 INSULATION IN ATTIC
Comments: Inspected, Compliant
9.7 INSULATION UNDER FLOOR SYSTEM
Comments: Not Present
9.8 VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT)
Comments: Not Present
9.9 VENTILATION OF FOUNDATION AREAS
Comments: Not Present
9.10 VENTING SYSTEMS (Kitchens, baths and laundry)
Comments: Inspected, Compliant, Repair or Replace
The guest bath vent fan duct pipe is not installed in the attic from the fan to the outside of the house, review and repair.
9.10 Picture 1
9.11 VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)
Comments: Not Present
9.12 ATTIC VENTILLATION
Comments: Inspected, Compliant
9.13 WOOD DETERIORATION
Comments: Inspected, Compliant
9.14 PEST INSPECTION
Comments: Not Inspected
There are signs of wood boring pest activity, possibly prior. Obtain and review the wood infestation report for termite activity and wood deterioration.
9.14 Picture 1
The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.

Prepared Using HomeGauge
http://www.HomeGauge.com : Licensed To Abode Inspection Services
Top Table of Contents Bottom
 
  INVOICE

Abode Inspection Services
P O Box 64127
Tucson, AZ 85728
520-401-0400
Inspected By:  Jim Josephson
Inspection Date: 1/16/2011
Report ID: 20110116a

Customer Info: Inspection Property:
John Smith
1234 N Tucson Boulevard
Tucson AZ 85701


Customer's Real Estate Professional:
Mary Sellers
Real Estate Pro  
1234 N Tucson Boulevard
Tucson AZ 85701
 

Inspection Fee:

ServicePriceAmountSub-Total
Inspection 290.00 1 290.00

Tax $0.00
Total Price $290.00

Payment Method: Check
Payment Status: Paid At Time Of Inspection
Note:

Top Table of Contents Bottom
 
Abode Inspection Services P.O. Box 64127 Tucson, AZ 85728 Office (520)-401-0400 Fax 498-4987
INSPECTION AGREEMENT - This binding agreement limits our liability - please read carefully
SCOPE OF INSPECTION; The purpose of the inspection is to give the client a better understanding of the property condition on the day of inspection. Inspection Company will perform a General limited inspection of hundreds of items in the primary home/building and primary parking structure and provide the Client and their Realtor with a written report of the General visual conditions and identify any obvious “major” deficiencies of the buildings Structural Components; Exterior; Roofing; Attic; Crawl Spaces; Plumbing, Toilets, Showers, Tubs, Faucets; Built-in kitchen Appliances; Heating/Cooling; Electrical Service, Outlets, Switches, Lights; Walls, Ceiling, Floors, Cabinets; Insulation and Ventilation; This is not an all encompassing inspection and report dealing with every aspect of the building, also some items are randomly checked. Items inspected and not inspected will be in accordance with the Arizona Board of Technical Registration (BTR) “Standards of Practice”. A copy of which you should read is provided with this agreement, available upon request or viewable on line at azashi.org.
VISUAL INSPECTION ONLY: Limited to items within the scope of the inspection that is visible and readily accessible at time of inspection. Inspector does not move furniture, personal items, ceiling tiles, insulation, vegetation, etc. which may impede access or limit visibility. All utilities and pilots must be on and equipment in operational condition - the inspector does not turn things on that are shut down, disconnected, not operable by normal controls, unplugged, not inspected or not operable due to weather, do destructive measures, dismantle items, or deemed by the Inspector to likely involve risk to person or property. As to those items not examined, have deficiencies, defects which are latent or concealed, or multiple identical components not randomly checked - no opinion is passed as these are excluded from inspection. A GENERAL INSPECTION DOES NOT INCLUDE THE FOLLOWING; whether or not concealed, In addition the limits above are incorporated. Radon, formaldehyde, mold/fungus, lead, water pollutants, sick building syndrome, asbestos, electromagnetic fields, fire resistive qualities, acoustical or other nuisance characteristics, Toxic or flammable chemicals. Soil stability/ Air/ water/ noise evaluations, Presence/damage caused by termites, pest, rodents, dry rot fungus. Chinese Drywall – inspector is not qualified to detect the presence of this. Accordingly the issues of Chinese Drywall (and its potential problems). Private wells, Septic systems; Rain water storage systems; Water conditioners, Circulating devices, Reverse osmosis; Solar water heating systems; Non visible gas, water and drain pipes; Fire sprinkler systems; Steam baths; Saunas; Shower pans; Sink/tub overflows; Washing machine; Washing machine drain lines and drainage; Dryers; Pressure testing of gas piping system; Gas leaks; Gas, water or any other shut-off valves; Determination of public or private water supply and waste disposal systems; Ejector pumps for rain or waste, Notification of product recalls, defects, or similar notices Remote control devices; low voltage wiring, Ancillary wiring systems and components such as telephone, cable, speaker, TV, Audio / intercoms / alarms, motion / sensor lights, security/ display lighting, remote controls, automatic timer controls, Measure amperage, voltage, or impedance. Antennae; Roofs or areas not accessible from a 14-foot ladder; Attic’s with insulation that covers wood and makes walking dangerous; Disturbance of insulation. Landscape lighting, Irrigation/drip systems; Outdoor barbecue’s and kitchens; Fire pits; Fences/ block walls/ gates; Automatic gates; Intermittent occurrences, Flood potential determination; Water falls; Fountains; Ponds; Mist systems; Landscaping, Spas, saunas, steam baths, swimming pools, exercise equipment, putting greens, entertainment items, playground equipment, etc.; Non visible foundations, Detached structures / buildings (except primary garage or carport); Condition of Paint, Wall paper, Stains, Water Proffers / Sealers; Screening, shutters, awnings, Crawl spaces, attics with less than 24 inches of clearance, Central vacuum systems; Free-standing kitchen appliances, self cleaning settings, clocks or timers, work and cleaning efficiencies.; Cosmetic items; Floor coverings, Carpet, Window coverings (blinds, draperies, etc.); Elevators, lifts or dumbwaiters, Adequacy or efficiency of any system or prediction of life expectancy. Flues or chimneys not visible; humidifier or dehumidifier; electronic air filter; Solar heating system; Heat supply adequacy, efficiency or distribution balance; Heat exchangers, Window / Wall Air conditioning units, gas fired cooling systems, Determination of draft characteristics. Engineering analysis of structural; Value appraisal, insurability, cost estimates; Permit research, validation, building code or zoning violations; Compliance for past or present building codes; Verification of compliance of installation guidelines; The causes of any deficiency; Any system or component not listed in the “Standards of Practice” of the Arizona Board of Technical Registration requirements; Any item noted as being excluded in the inspection report. SPECIAL REQUEST for ABOVE ITEMS; This is not intended to limit the Client to items that are out of the scope of a General inspection. If you have a specific concern about something, the Inspection Company may be able to inspect those items when possible for an additional Fee. Or you can have them inspected by a specialist prior to closing. In addition to these identified herein or excluded systems and components from the inspection. Should we, as a courtesy exceed any particle requirement set forth herein in one area, we shall not be obligated or required to exceed the requirements in other areas.
THIS INSPECTION IS NOT TECHNICALLY EXHAUSTIVE; which requires specialists, more time, calculations, specialized testing equipment, or skills. An Extensive inspection may find additional or more problems than this General limited visual inspection. Client who wishes a more Extensive / Technically exhaustive inspection should inform the inspector prior to the inspection, and arrange for those services independently. WRITTEN REPORT; shall be considered the final and exclusive findings of the inspector regarding the property. Client shall not rely on oral statements made by the inspector prior to issuance of the written report. Report contains the entire examination, findings and “inspectors opinion” on the general findings including any “major” visible deficiencies. Inspection and report are not intended to make any representation as to the advisability of purchase of the property or suitability for use. Inspector and report is not a party to any clause setting forth the scope of inspection in a selling or purchase agreement.
COSMETIC, MINOR DEFECTS or DEFICIENCIES; may be noted or discussed as a courtesy but are not within the required scope of inspection. The inspection report is not to inform you about typical or minor items or tell you what it takes to make a used house / building to be in perfect or like new condition. Remember we are here for “Major” defect items. As to anything else not in the report, the same are outside the scope of the inspection and not opinioned upon by the inspector.
CLIENT SAFETY RESPONSIBILITIES; Client agrees to be responsible for Client, client representative, family and friends safety, any damages or injuries they incur while on the property. Use of inspector’s equipment is prohibited as ladders or equipment can fail at any time due to age, not being set up properly or other causes. NO WARRANTY or GUARANTEE: The inspection report is not intended to be used as a guarantee or warranty or insurance policy of any kind, express or implied, regarding the adequacy, performance or condition of the property or any part of it now and in the future. INSPECTION FEE; Is for the “time period reserved” for the Client, not for items inspected. Total fee is due once inspector has arrived at the property whether or not an inspection is performed. Fee is not prorated for # of items inspected. Additional fee is charged for a return visit to inspect any items not inspected now for any reason. LIMIT OF LIABILITY; The maximum liability for any claim arising from the inspection or outside of the inspection is not to exceed twice the fee paid for the inspection. There will be no recovery for damages or any other relief other than this liquidated remedy. The Inspector assumes no responsibility for damages outside this limitation, whether property, financial or bodily injury or fatality, regardless of the cause. Inspector is not liable for the security and condition of the property and its contents or premises. Inspector has no liability whatsoever for inspection or report not paid by client. Customer agrees to immediately accept a refund of this amount as full and final release settlement of this and any other claims that may arise from the inspection. NOTICE OF CLAIM LIMITATION PERIOD; In the event of any claim, Client agrees that no claim, legal action or proceeding of any kind can be commenced more than one (1) year from the date of the subject inspection. Notice, to be effective, must be mailed certified mail to the inspectors address shown herein. Failure to initiate a claim within this time period will be concluded as though all statutes of limitations had run; this will be deemed waived and forever barred. CLIENT AGREES TO THESE TERMS THOUGH THE TIME PERIOD MAY BE SHORTER THAN OTHERWISE PROVIDED BY LAW.
DISPUTE RESOLUTION and REMEDY LIMITATIONS; If the client has any dispute concerning interpretation of this Agreement or arising from this inspection and report except one for non-payment of inspection fee. It shall be REPORTED IN WRITING and BY PHONE CALL to the inspector within 10 business days of discovery. Only after the inspector has received this written notice and phone call and confirmed it with you, the inspector shall review the area in question within 3 business days in considerations of parties’ schedules. Unless there is an emergency - Client agrees that no alterations, repairs, or replacement to the area will be made prior to a re-inspection by the inspector. If they are altered or repaired before said notice, re-inspection, and a response, you agree not to hold the Inspection Company or inspector responsible for any claims or payments and this will be deemed waived and forever barred. MEDIATION / ARBITRATION USING THE AMERICAN ARBITRATION ASSOCIATION; If a dispute cannot be settled through direct discussion, Client agrees the dispute shall be settled in Tucson Arizona first by Mediation, if unsuccessful, than by Binding non-appealable Arbitration in accordance with the rules of the American Arbitration Association. The decision of an Arbitrator shall be final and binding and the judgment of the award may be entered in any court having jurisdiction. The applicable law shall be the law of the State of Arizona. I understand and agree that I am waiving my right to use other Arbitration sources, and a jury or court trial. LEGAL FEES / OTHER EXPENSES; If either party makes or files a dispute or claim against the other for actions arising out of the work performed under this contract and fails to prove all aspects of such claim, the party making the claim will pay the prevailing party all attorney/solicitor fees, all mediation/arbitration fees, cost associated with expenses incurred in the defense of the claim inclusive of expert investigation, report and testimony fees, Court reporters and the like. Client agrees that if they dispute or attempt to use any other Arbitration or court system and fail at this attempt, client agrees to separately and IMMEDIATELY pay all the attorney/solicitor fees and prevailing parties cost associated with expenses incurred in this attempt. Client agrees to pay all company cost, legal fees, and expenses incurred in the enforcement of this agreement and in collecting of unpaid fees. A $25.00 fee is charged for returned checks, denied credit card charges and is assessed at a rate of 24% per annum. SEVERABILITY: If any court or arbitrator determines that any word or part of this contract is invalid or unenforceable, the remainder of the contract shall remain in full force and effect. THIRD PARTY AFFILIATIONS: The Inspection Company may have an affiliation with third party service providers ("TPSP's") in order to offer value-added services to Clients. Clients’ signing this agreement authorizes our TPSP's to call Client at the numbers provided to the Inspection Company to discuss special services offers. Compensation or fee may be received from TPSP's for administrative / scheduling services provided by the Inspection Company pertaining to this inspection.
USE BY OTHERS NOT ALLOWED: The inspection and report are prepared for the sole confidential and exclusive use and possession of the Client only. Use or reliance upon the report or our services by any other parties, or for other transactions, is strictly prohibited. All examinations and reports covered by this agreement are void to all others than Client. Unless specifically authorized in writing by inspector, the report may not be circulated to anyone else or entity for material use other than Client or it shall become void. If the report is disclosed or distributed to any person or entity other than Client, the report is void and you agree to indemnify, defend and hold the Inspection Company / Inspectors harmless from any third party claims. AMENDMENTS TO REPORT AND OTHER EXPERTS: Client understands and agrees that the inspector reserves the right to modify/amend the inspection report within 48 hours from the date of delivery. The inspector is a generalist and is not a licensed engineer or expert in any specific craft or trade. If the inspector recommends consulting other specialized experts or appropriate repair persons, Client is responsible for what ever could have been determined from consultation with those experts had client contacted them as recommended. Inspector is not responsible for the advice of other experts or consultants contacted by Client. INSPECTION AGREEMENT / SIGNATURE: No change or modification shall be enforceable against any party unless such change or modification is in writing and signed by Client and Home Inspector. Each party signing this Agreement warrants and represents to the inspector that he/she has full capacity and complete authority to execute this agreement on their behalf or Client’s behalf. If a Client’s Representative signs on behalf of the Client, it shall have the same effect as complete pre-inspection authorization by the Client and fully binds the Client to all the terms, conditions, limitations, exceptions and exclusions in this agreement. This can be signed in counterpart and by fax or mechanical means and it shall be deemed properly signed. Client agrees that it does not matter whether this is signed before, during or after the inspection and report, it shall be binding and will supersede. READING AND APPROVAL: By signing this Agreement, I acknowledge that I have reviewed and/or read both pages in its entirety and I understand and agree to be bound by all terms and conditions, including (but not limited to) the limitation of liability, Mediation and Arbitration clause, limitations period and legal fees. I understand this is a “limited visual inspection” of only certain items. To read all pages of the Inspection Report and supplemental information provided. And I understand that the Report will not be released until full payment is made or placed in escrow and this signed agreement is received at the Inspection office.
Property Address: 1234 N Tucson Boulevard Tucson, AZ 85701 Total Fee $290.00
Client: John Smith       (X): (sign)_______________________________________Date: January 17, 2011

Abode Inspection Services, James Josephson, AZ # 38082: ________________________________ Date: January 17, 2011
Top Table of Contents Bottom