Property Address:
123 Abc Lane
Show Low Arizona 85901
Steve Wasden # 68545
Certified Master Inspector
PO Box 604
Snowflake, AZ, 85937
(928) 241-2446
Date: 9/4/2021 | Time: 08:00 AM | Report ID: SAMPLE2021 |
Property: 123 Abc Lane Show Low Arizona 85901 |
Customer: Sam Sample |
Real Estate Professional: |
All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
This inspection was conducted in accordance with the Arizona Standards of Professional Practice for Home Inspectors as noted in your inspection agreement.
STYLE OF HOME: SINGLE FAMILY DETACHED, ONE STORY | AGE OF HOME: 10-20 YEARS OLD | BUILDING FACES: SOUTH |
WEATHER: SUNNY | TEMPERATURE: 70-80 DEGREES | RAIN IN LAST 3 DAYS: YES |
CLIENT IS PRESENT: NO |
FOUNDATION TYPE:
REINFORCED CONCRETE w/RAISED FLOOR MASONRY STEMWALL |
FLOOR STRUCTURE TYPE:
I-JOIST FRAMED |
WALL STRUCTURE TYPE:
WOOD FRAMED |
COLUMN TYPE:
WOOD POSTS |
ROOF/CEILING STRUCTURE TYPE:
ENGINEERED TRUSS ORIENTED STRAND BOARD DECKING. (OSB) |
1.0 |
FOUNDATION
|
Overall, the foundation was satisfactory to the extent observable. Inspection limited. |
1.1 |
FLOORS
|
Overall, the floor structure was satisfactory to the extent observable. Inspection limited. |
1.2 |
WALLS
|
Overall, the structural walls were satisfactory to the extent observable. Inspection limited. |
1.3 |
COLUMNS/POSTS
|
Overall,the posts/columns were satisfactory to the extent observable. |
1.4 |
ROOFS/CEILINGS
|
Overall, the roof & ceiling structure was satisfactory to the extent observable. Inspection limited. |
1.5 |
UNDER FLOOR CRAWLSPACE
|
Overall, the crawlspace was satisfactory to the extent observable. |
1.6 |
OBSERVATION METHOD
|
I viewed the visible portions of the structure from the attic and the crawlspace.
![]() ![]() ![]() ![]() |
1.7 |
GENERAL
|
All of the visual structural components of the home were satisfactory to the extent observable. I inspected the visual portions of the foundation, floor, walls, columns (if present), roof and ceiling. Obviously some of these components are not fully visible but we look for evidence of structural movement in the interior walls, ceilings and floors. |
ROOF COVERING TYPE:
ARCHITECTURAL ASPHALT FIBERGLASS SHINGLES |
2.0 |
ROOF MATERIAL
|
Overall, the roof surfaces are satisfactory to extent observable.
![]() ![]() ![]() ![]() |
2.1 |
FLASHINGS & PENETRATIONS
|
![]() |
Potential leak points should be sealed to prevent water intrusion. The plumbing vent flashing (roof jack) was damaged. Repair/replace as needed to prevent interior damage from water intrusion. ![]() |
2.2 |
DRAINAGE SYSTEMS
|
The visible portions of the roof drainage system are in satisfactory condition. Below ground drain lines for downspouts are not visible and I am unable to determine if drains will function properly. |
2.3 |
SKYLIGHTS
|
Skylights not present. |
2.4 |
CHIMNEYS
|
Chimney not present. |
2.5 |
EVIDENCE OF LEAKING
|
![]() |
There is evidence of a roof leak at front eaves. Further evaluation recommended.
![]() ![]() |
2.6 |
METHOD USED TO OBSERVE
|
Walked roof. |
2.7 |
GENERAL
|
Overall, the roof and components were satisfactory to the extent observable. |
WALL CLADDING TYPE:
FIBER CEMENT |
3.0 |
WALL CLADDING
|
Overall the visible portions of the exterior wall cladding is satisfactory to extent observable. Minor wear and tear commensurate with the age of the home. |
3.1 |
FLASHING & TRIM
|
Overall, the visible portions of the flashing and trim are satisfactory to extent observable. |
3.2 |
EAVES, SOFFITS & FASCIA
|
Overall, the visible portions of the eaves, soffits and fascia are satisfactory to extent observable. |
3.3 |
ENTRY DOORS
|
(1) We recommend having the locks re-keyed or new locks installed upon occupancy. | |
![]() |
(2) Dead bolt locks should be keyed on the exterior only with a thumb latch on the interior side. The exterior door provides emergency egress from the house, in the event of a fire, valuable time could be lost looking for a key to open the door. Replace dead bolt lock for safety. |
3.4 |
WINDOWS
|
![]() |
Window has lost its thermal seal, the foggy appearance indicates the presence of moisture between the panes of glass. The dual pane
window is no longer as thermally efficient as originally designed and may also be considered a cosmetic issue with poor visibility. Some
windows with failed seals are difficult to notice except at certain times of day. I recommend a Licensed Window Contractor check all the
windows and repair or replace as needed.
![]() |
3.5 |
GARAGE DOOR & OPENER
|
The garage doors and openers are in satisfactory condition and operational, including the safety reverse features. |
3.6 |
STEPS & RAILINGS
|
The visible portions of the steps and railings were satisfactory to extent observable. |
3.7 |
DECK
|
The deck condition was satisfactory to the extent observable. Deck needs cleaning with a "Deck wash" and seal with a waterproof sealant. |
3.8 |
BALCONY
|
Balcony not present. |
3.9 |
PORCH
|
The visible portion of the porch is in satisfactory condition to extent observable. |
3.10 |
AREAWAY
|
Areaway not present. |
3.11 |
PATIOS, WALKS & DRIVEWAYS
|
Surface deterioration at driveway may be due to poor workmanship or poor weather conditions when poured.
![]() |
3.12 |
GRADING & DRAINAGE
|
Overall the grading and drainage is in satisfactory condition and has no adverse impact on the structure. |
3.13 |
VEGETATION
|
There is no adverse impact on the structure due to vegetation. Keep trees trimmed away from house to prevent damage to roof and siding. |
3.14 |
RETAINING WALLS
|
Retaining wall not present. |
SERVICE TYPE:
UNDERGROUND |
SERVICE CONDUCTOR TYPE:
COPPER |
OVERCURRENT PROTECTION DEVICES TYPE:
CIRCUIT BREAKERS |
SERVICE AMPERAGE/VOLTAGE:
200 AMP 120/240 VOLT |
MAIN PANEL LOCATION:
EXTERIOR LEFT SIDE |
4.0 |
SERVICE ENTRY
|
The visible portion of the service entry is in satisfactory condition. |
4.1 |
SERVICE CONDUCTOR
|
The service entry conductors were in satisfactory condition to the extent visible. |
4.2 |
SERVICE GROUND
|
Service ground was satisfactory to the extent observable. Inspection limited. |
4.3 |
MAIN PANEL
|
The overall condition of the electrical panel was satisfactory to extent observable .
![]() ![]() ![]() |
4.4 |
DISTRIBUTION PANEL
|
Not present |
4.5 |
OVERCURRENT PROTECTION DEVICES
|
Overall the visible portions of the over current protection devices (breakers/fuses) are in satisfactory condition. |
4.6 |
COMPATIBILITY
|
The breakers are compatible (not oversized) with the conductor size. |
4.7 |
BRANCH CIRCUIT CONDUCTORS
|
![]() |
Electrical wires need proper protection at kitchen. This is a Safety hazard. We recommend a licensed electrician evaluate and repair or
replace as needed.
![]() ![]() ![]() ![]() |
4.8 |
ALUMINUM BRANCH CIRCUIT WIRING
|
We did not observe any solid aluminum branch circuits. We are required to look for the presence of solid strand aluminum branch wiring. It was used during the mid 1960's-1970's and became known for being problematic, mainly due to arcing at switches and receptacles. |
4.9 |
LIGHTS & SWITCHES
|
(1) Light fixture/s inoperable with the wall switch. Replace the fixtures/bulbs as needed to verify operation or repair as needed.
![]() REAR BEDROOM
![]() KITCHEN
|
|
(2) Ceiling fan/light out of balance. Repair as needed at living room
![]() ![]() FAN
|
4.10 |
RECEPTACLES
|
![]() |
(1) We found open ground receptacles near water. This is a safety hazard. A licensed electrician is recommended for repair at kitchen.
![]() |
(2) All other receptacles were tested for polarity and ground and found to be operational and in satisfactory condition except where noted. |
4.11 |
GROUND FAULT CIRCUIT INTERRUPTERS
|
GFCI protected receptacles function as intended and present in required interior locations. GFCI protected receptacles function as intended and present in required exterior locations. |
4.12 |
SMOKE & CARBON MONOXIDE DETECTORS
|
(1) Noted, but not tested. As a general rule smoke detectors are not tested. I recommend testing them on at least a monthly basis. This is left to
the buyer because closings are often longer than 1 month, and in this time batteries can go dead and the new homeowner has a false sense
of security, believing that the smoke detectors have been tested and are in working order.
Add fresh batteries to all smoke detectors and verify operation upon occupancy. |
|
(2) There are two types of smoke detectors found in homes today: Ionization and Photoelectric.
Ionization type detectors are installed in about 90% of homes and are more sensitive to flaming stage of a fire. Open (fast flame) fires account for the majority of house fires and injuries, but only 15% of fire fatalities. Ionization type detectors respond slower to smoldering fires and fail completely 20-25% of the time. Photoelectric type detectors are more sensitive to smoldering stages of fires which account for 12% of fires, but 50% of fire fatalities and 30% of injuries. The majority of fire related deaths occur during smoldering fires while the occupants of the home are sleeping. We strongly recommend replacement of all Ionization type detectors with Photoelectric type detectors or combination type. Manufacturers recommend regular testing of smoke and carbon monoxide detectors. All smoke detectors should be replaced after 10 years due to loss of sensitivity. ![]() SMOKE DETECTORS
|
4.13 |
GENERAL
|
Due to the safety concerns involved with electricity, we recommend a qualified person make any needed repairs. For instance, a switch coverplate is relatively easy to replace that most people are comfortable doing but working inside an electrical panel with energized components should only be done by a licensed electrician. |
INTERIOR SUPPLY/DISTRIBUTION PIPING TYPE:
COPPER |
DRAIN WASTE & VENT PIPING SYSTEM TYPE:
ABS |
WATER HEATER TYPE & CAPACITY:
NATURAL GAS 50 GALLONS AGE : 20 YEARS OLD |
5.0 |
INTERIOR SUPPLY & DISTRIBUTION PIPING
|
Overall, the visible portions of the interior supply and distribution system are in satisfactory condition. There is no evidence of active supply side leaks. |
5.1 |
SUPPORTS & INSULATION
|
Pipe support was good. We recommend insulating the water pipes in crawlspace to prevent freezing in winter. |
5.2 |
FIXTURES & FAUCETS
|
Overall the fixtures and faucets are in satisfactory condition and operational. |
5.3 |
FUNCTIONAL FLOW
|
![]() |
The water flow was restricted. This may be due to a faulty valve, a partially closed valve, debris lodged inside the valve, a kinked supply tube or
corroded pipes. Functional flow is defined as a reasonable flow at the highest fixture in a dwelling when another fixture in the home is operated
simultaneously. A licensed plumber is recommended for evaluation and repair at master bathroom.
![]() ![]() |
5.4 |
CROSS CONNECTIONS
|
There were no potential cross connections observed. |
5.5 |
DRAIN, WASTE & VENT SYSTEM
|
Drain pipes show evidence of leaking. This should be monitored for leaks and repairs made as needed.
Overall the visible portions of the waste and vent system are in satisfactory condition. ![]() GUEST BATHROOM
![]() MASTER BATHROOM
|
5.6 |
FUNCTIONAL DRAINAGE
|
A drain is considered functional when it empties in a reasonable amount of time and does not overflow when another fixture is drained simultaneously. Drainage was satisfactory. |
5.7 |
WATER HEATER EQUIPMENT & CONTROLS
|
The water heater was functional but nearing the end of it's service life.
The water heater temperature is low. This can allow bacteria to grow in the tank which can be unhealthy. We recommend setting the temperature to 120 degrees to prevent bacteria and not hot enough to scald. ![]() |
5.8 |
AUTOMATIC SAFETY CONTROLS
|
A TPR valve and thermocouple/limit switch are present in each water heater, the visible portions are in satisfactory condition. |
5.9 |
FLUES & COMBUSTION AIR VENTS
|
The flues, vents and combustion air vents are present and in good condition. |
5.10 |
FUEL STORAGE, DISTRIBUTION & SUPPORTS
|
The visible portions of all fuel distribution piping and supports are in satisfactory condition. Please ask seller to properly cap off gas line to dryer when they remove their dryer upon moving. |
5.11 |
SUMP PUMPS
|
The home has a sewage ejector pump. If pump becomes inoperable the alarm should sound. We don't test this feature.
You might consider having pump and alarm inspected by a licensed plumber. ![]() |
5.12 |
GENERAL
|
(1) The inspection is a snapshot in time and cannot predict when leaks may occur. Leaks in plumbing can happen at any time. Upon walkthrough and occupancy, we recommend checking under sinks for new leaks. It is not uncommon for drains and supply valves to be bumped while moving personal items out of the cabinets creating leaks. | |
(2) Tub overflows are not tested due to the very high likelihood the gaskets will leak. Care should be exercised in filling tubs to not allow water into the overflow. While they will likely drain away the bulk of water, some amount of leaking should be anticipated. As an improvement, have the licensed plumber check the gasket and make repairs deemed necessary in the context of other plumbing repairs made at the home. Again, it should be assumed these overflows will not be water tight. | |
(3) Only a video-scan of the interior of drainpipes and drain lines can fully confirm their actual condition. When the house is vacant, the plumbing system is older, there are prior known drain problems or there are large trees on the grounds, it would be prudent to have the drain lines "video-scanned" prior to closing. |
HEATING TYPE:
FORCED AIR HIGH EFFICIENCY FURNACE AGE : 20 YEARS OLD |
DISTRIBUTION:
BLOWER/FAN INSULATED DUCTS |
ENERGY SOURCE:
NATURAL GAS |
HEATING TYPE #2:
FIREPLACE |
DISTRIBUTION #2:
BLOWER/FAN |
ENERGY SOURCE #2:
NATURAL GAS |
HEATING TYPE #3:
FREE STANDING |
DISTRIBUTION #3:
BLOWER/FAN |
ENERGY SOURCE #3:
WOOD |
COOLING TYPE:
SPLIT SYSTEM AGE : 10 YEARS OLD |
A/C DISTRIBUTION:
BLOWER/FAN INSULATED DUCTS |
A/C ENERGY SOURCE:
ELECTRICITY |
6.0 |
HEATING EQUIPMENT
|
(1) The overall condition of the forced air heating equipment is functional. Rust at burner compartment. We recommend service or repair as needed ![]() ![]() |
|
(2) The gas fireplace is in satisfactory condition and operational. |
6.1 |
COOLING EQUIPMENT
|
The overall condition of the cooling system is functional. The temperature differential is in the normal range of 14-22 degrees. |
6.2 |
OPERATING CONTROLS (THERMOSTAT)
|
The thermostat is functional. |
6.3 |
AUTOMATIC SAFETY CONTROLS
|
The automatic safety controls are present. |
6.4 |
CHIMNEYS, FLUES & VENTS
|
The flues, vents and combustion air vents are present and in good condition. |
6.5 |
DISTRIBUTION SYSTEM
|
The visible portions of the distribution system are in satisfactory condition. |
6.6 |
SOURCE
|
There is a source of heating & cooling in each habitable room. |
6.7 |
AIR FILTERS
|
The filter is in satisfactory condition. Install fresh filter as needed. The size of the filter is 20x30x1 |
6.8 |
SOLID FUEL HEATING
|
The visible portions of the fireplace are in satisfactory condition. I recommend professional cleaning and flue inspection before use. |
6.9 |
GENERAL
|
The overall condition of the forced air heating equipment is functional. |
INSULATION TYPE:
LOOSE FIBERGLASS LOCATION : ATTIC |
VAPOR RETARDER TYPE:
NOT VISIBLE NOT DETERMINED |
7.0 |
INSULATION
|
Overall the visible insulation in attic is in satisfactory condition to the extent observable. Blown fiberglass insulation in attic has an R-Value of 2-1/2 to 3 per inch. Approximate depth was 12-15 inches |
7.1 |
VAPOR RETARDER
|
Vapor retarder is not visible. Not inspected. |
7.2 |
ATTIC VENTILATION
|
Overall the visible portions of the attic ventilation are in satisfactory condition. |
7.3 |
CRAWL SPACE VENTILATION
|
Crawl space ventilation is present and in good condition. Open the vents in summer and close in cold winter months. |
7.4 |
KITCHEN VENTILATION
|
The recirculating kitchen ventilation fan is functional. |
7.5 |
BATHROOM VENTILATION
|
The bathroom ventilation fans/windows are functional. |
7.6 |
LAUNDRY VENTILATION
|
The laundry room ventilation fan or operable window is functional. The visible parts of the dryer vent were satisfactory. |
8.0 |
WALLS, CEILINGS & FLOORS
|
Overall, the visible portions of the walls, ceilings and floors are in satisfactory condition except for normal wear/age. General cosmetic blemishes observed. Holes from nails, screws, door knobs or patches do not affect function. Typical settling cracks. Nail pops throughout home. These are typically due to the home settling. |
8.1 |
STAIRS, BALCONIES & RAILINGS
|
Not Present |
8.2 |
COUNTERS & CABINETRY
|
(1) Overall the visible portions of the counters and cabinetry are in satisfactory condition. Counters and/or cabinets may have cosmetic blemishes. This does not affect function. FYI |
|
(2) Countertop needs caulking at kitchen
![]() |
8.3 |
DOORS
|
The interior doors were tested and found to be operational and in satisfactory condition. Add door bumps to all interior doors as needed to prevent damage to the walls. |
8.4 |
WINDOWS
|
The windows were operated and found to be satisfactory. |
8.5 |
FIRE SEPARATION WALLS & CEILINGS
|
The attic access stairs/panel installed in the garage ceiling does not provide the required fire resistance, plywood cover panel does not meet
requirement. We recommend replacement with a panel that provides the required fire resistance.
![]() FIRE SEPARATION
|
8.6 |
FIRE SEPARATION DOORS
|
Fire separation door was satisfactory. Adjust the fire door to close automatically, latch and seal as required. |
9.0 |
DISHWASHER
|
![]() |
(1) The dishwasher is leaking. It may be the door gasket or it may be leaking under the unit. Further evaluation required. We recommend a
qualified appliance repair person evaluate and repair or replace as needed.
![]() ![]() |
(2) The dishwasher is functional. |
9.1 |
FOOD WASTE DISPOSAL
|
The disposal is functional. |
9.2 |
MICROWAVE COOKING EQUIPMENT
|
The microwave oven is functional. |
9.3 |
RANGE, OVEN & COOKTOP
|
The range/oven is functional. |
9.4 |
REFRIGERATOR
|
The refrigerator is functional. |
9.5 |
GENERAL
|
(1) Our standards of practice do not require us to inspect appliances but if present we do as a courtesy. | |
(2) If you are qualified and decide to make repairs yourself, I recommend RepairClinic.com for parts. They also have many videos to help with repairs. |
10.0 |
GENERAL COMMENTS
|
(1) The process of buying a home can be stressful. Relax. Remember that no home is perfect and sellers are not required to repair anything.
The report may have maintenance recommendations and minor imperfections. These are good to know about. However, the issues that really matter will fall into four categories: 1. Major defects, such as structural failure; 2. Conditions that can lead to major defects, such as a roof leak; 3. Safety hazards, such as an exposed, live bus bar at the electrical panel. 4. Defective items that may cost over $1,000 dollars for repairs, such as siding, garage doors, chimney etc.
Anything in these categories should be addressed as soon as possible.
As a homeowner don't forget that maintenance is key to your home's value and your happiness while living in it.
If you have any questions regarding your inspection report, feel free to contact us.
Thank you very much for your business. We wish you many happy years ahead in your new home. |
|
(2) The SPDS was not available at the inspection, please review the SPDS for any items that need repair or further inspection. |
Certified Master Inspector
PO Box 604
Snowflake, AZ, 85937
(928) 241-2446
Customer
Sam Sample
Address
123 Abc Lane
Show Low Arizona 85901
We will also add that any item that we consider to be costly to repair will be in the major summary.
This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency. This Summary is NOT the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
2.1 | FLASHINGS & PENETRATIONS | |
![]() |
Potential leak points should be sealed to prevent water intrusion.
The plumbing vent flashing (roof jack) was damaged. Repair/replace as needed to prevent interior damage from water intrusion. ![]() |
2.5 | EVIDENCE OF LEAKING | |
![]() |
There is evidence of a roof leak at front eaves. Further evaluation recommended.
![]() ![]() |
3.3 | ENTRY DOORS | |
![]() |
(2) Dead bolt locks should be keyed on the exterior only with a thumb latch on the interior side. The exterior door provides emergency egress
from the house, in the event of a fire, valuable time could be lost looking for a key to open the door. Replace dead bolt lock for safety.
|
3.4 | WINDOWS | |
![]() |
Window has lost its thermal seal, the foggy appearance indicates the presence of moisture between the panes of glass. The dual pane
window is no longer as thermally efficient as originally designed and may also be considered a cosmetic issue with poor visibility. Some
windows with failed seals are difficult to notice except at certain times of day. I recommend a Licensed Window Contractor check all the
windows and repair or replace as needed.
![]() |
4.7 | BRANCH CIRCUIT CONDUCTORS | |
![]() |
Electrical wires need proper protection at kitchen. This is a Safety hazard. We recommend a licensed electrician evaluate and repair or
replace as needed.
![]() ![]() ![]() ![]() |
4.10 | RECEPTACLES | |
![]() |
(1) We found open ground receptacles near water. This is a safety hazard. A licensed electrician is recommended for repair at kitchen.
![]() |
5.3 | FUNCTIONAL FLOW | |
![]() |
The water flow was restricted. This may be due to a faulty valve, a partially closed valve, debris lodged inside the valve, a kinked supply tube or
corroded pipes. Functional flow is defined as a reasonable flow at the highest fixture in a dwelling when another fixture in the home is operated
simultaneously. A licensed plumber is recommended for evaluation and repair at master bathroom.
![]() ![]() |
9.0 | DISHWASHER | |
![]() |
(1) The dishwasher is leaking. It may be the door gasket or it may be leaking under the unit. Further evaluation required. We recommend a
qualified appliance repair person evaluate and repair or replace as needed.
![]() ![]() |
![]() |
INVOICE |
Homestead Inspections, LLC
Certified Master Inspector PO Box 604 Snowflake, AZ, 85937 (928) 241-2446 Inspected By: Steve Wasden |
Inspection Date: 9/4/2021
Report ID: SAMPLE2021 |
Customer Info: | Inspection Property: |
Sam Sample
Customer's Real Estate Professional: |
123 Abc Lane Show Low Arizona 85901 |
| ||||||||
Tax $0.00 | ||||||||
Total Price $350.00 |
Payment Method: Cash
Payment Status: Paid
Note: Thank you for choosing Homestead Inspections, LLC