Property Address:
33 N Olcott Ave Unit 301
Chicago IL 60403
Julio C Patino Pacheco 450.012079
221 W Dempster St
Des Plaines, IL, 60016
Date: 3/7/2022 | Time: 04:00 PM | Report ID: 20220307-33-N-Olcott-Ave-Unit-301 |
Property: 33 N Olcott Ave Unit 301 Chicago IL 60403 |
Customer: Gabriel M |
Real Estate Professional: |
Comment Key or Definitions
This inspection was conducted in accordance with the State of Illinois Home Inspector Licensing Act. The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI) = I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Watch List (WL) = The item, component or unit requires schedule maintenance or monitoring.
Significantly Deficient (SD) = Defined by Illinois State Law as either a) not functioning or b) posing a safety hazard. It should be noted that a large number of significantly deficient items can be addressed at little cost. It is important to remember that the safety of a significantly deficient item is not based upon mere local building codes, which contain 'grandfathering' clauses, or the common 'accepted' practices of tradesmen, but on current national and international safety requirements and with the well being of the property and the client in mind.
Observations:
Text in red denotes an observation that in the inspectors opinion is a safety hazard, needs immediate repair, further evaluation, or is otherwise significantly deficient. These observations should generally be addressed before the close of escrow. You should read the entire report to understand all observations and recommendations.
Please Note: If you have any questions or any thing is unclear, please do not hesitate to contact Condo Home Inspections LLC and/or your specific inspector. We are happy to answer any of your questions.
PHOTOS: Your completed report may contain photographs of various conditions noted during the inspection. Photographs provided in this report are intended to help interested parties understand the context of this report, but may not represent the sum total of all conditions. You must read the entire report.
In Attendance: Customer | Type of building: Condominium | Approximate age of building: Over 10 Years |
Temperature: Over 65 (F) = 18 (C) | Weather: Clear | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Radon Test: No | Water Test: No |
Occupied or Vacant: Occupied |
47
Items Inspected
Total number in report.
10
Summary Comments
Total number in report.
1
Videos
Total number in report.
38
Photos
Total number in report.
1.0 |
Ceilings
Comments: |
1.1 |
Walls
Comments: |
I saw one broken tile in the primary bathroom. I recommend that a qualified handyman
contractor corrects the issue.
![]() 1.1 Item 1(Picture) |
1.2 |
Floors
Comments: |
1.3 |
Windows (representative number)
Comments: |
Interior windows displayed no signs of cracked glass or condensation stains. All windows
operated properly when tested.
|
1.4 |
Doors (representative number)
Comments: |
(1) Main entry door was not equipped with a self closing device. These devices are required to
prevent smoke and fire propagation between exit stairways and apartment.
![]() 1.4 Item 1(Picture) |
|
(2) Balcony screen door was damaged. Have the screen repaired or replaced.
![]() 1.4 Item 2(Picture) |
1.5 |
Steps, Stairways, Balconies and Railings
Comments: |
I saw broken tiles on the balcony. Have a qualified handyman contractor correct as needed.
![]() 1.5 Item 1(Picture) |
1.6 |
Counters and Cabinets (representative number)
Comments: |
One of the kitchen cabinet doors was loose and needs adjustment, see video.
Note: Kitchen cabinets were properly secured to back walls with the proper type fasteners. ![]() X
1.6 Item 1(Video) ![]() 1.6 Item 2(Picture) |
1.7 |
Pests & Rodents
Comments: |
1.8 |
Bathroom Vanity Tops & Cabinets
Comments: |
1.9 |
Shower Doors
Comments: |
Shower doors were tempered glass and without damage.
![]() 1.9 Item 1(Picture) ![]() 1.9 Item 2(Picture) ![]() 1.9 Item 3(Picture) ![]() 1.9 Item 4(Picture) |
2.0 |
Main Water Shut-off Device (Describe location)
Comments: |
There was no main water shut off found in the unit. I recommend asking the seller or building
association for location.
Note: All plumbing fixtures had dedicated shut-off valves that were readily accessible. |
2.1 |
Interior Water Supply, Distribution System
Comments: |
(1) I sensed or measured hot water flowing out of every tub spout and shower fixture at a
temperature that won't cause scalding.
![]() 2.1 Item 1(Picture) |
|
(2) The distribution water pipe system was composed of copper and was properly supported
where it was possible to observe. There were no distribution water leaks during the inspection.
All plumbing fixtures were properly connected to a hot water source.
|
2.2 |
Interior Drain, Waste and Vent Systems
Comments: |
Primary bathroom area shower drain was missing a floor strainer. Have it fixed as necessary.
Interior drain,waste and vent systems operated properly. No signs of leakage, or physical damage was observed, where it was possible to observe. ![]() 2.2 Item 1(Picture) ![]() 2.2 Item 2(Picture) |
2.3 |
Interior Plumbing Fixtures
Comments: |
2.4 |
Whirlpools
Comments: |
The hot tub operated properly without plumbing leaks. The motor was protected with a GFCI
breaker from the panel.
![]() 2.4 Item 1(Picture) ![]() 2.4 Item 2(Picture) |
2.5 |
Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks)
Comments: |
3.0 |
Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: |
3.1 |
Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure
Comments: |
3.2 |
Operation of GFCI (Ground Fault Circuit Interrupters)
Comments: |
All GFCI outlets should be tested monthly using the test and reset buttons to ensure proper
operation.
![]() 3.2 Item 1(Picture) |
3.3 |
Operation of AFCI (ARC Fault Circuit Interrupters)
Comments: |
3.4 |
Smoke Detectors / Carbon Monoxide Detectors
Comments: |
The smoke and carbon monoxide detectors should be tested at common hallway to bedrooms
upon moving in to home. The actual detector mechanisms in most smoke and carbon monoxide
detectors usually only last 4 to 5 years. Even though the detector may sound when the "test"
button is pushed, this button tests only the battery, not the detector.
Note: more than one unit was not equipped with back up batteries. Have the batteries installed so the units can operate during a blackout. ![]() 3.4 Item 1(Picture) |
3.5 |
Service Entrance Conductors
Comments: |
3.6 |
Location of Main and Distribution Panels
Comments: |
The electrical panel was located in the hallway.
![]() 3.6 Item 1(Picture) |
3.7 |
Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels
Comments: |
There were no safety issues found inside the panel.
![]() 3.7 Item 1(Picture) |
3.8 |
Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage
Comments: |
All breakers in panel were labeled.
![]() 3.8 Item 1(Picture) |
4.0 |
Heating Equipment
Comments: |
Heating equipment was composed of a water pipe system. No issues were found during the
inspection.
![]() 4.0 Item 1(Picture) |
4.1 |
Normal Operating And Safety Controls
Comments: |
The thermostat was located in the hallway.
![]() 4.1 Item 1(Picture) |
4.2 |
Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: |
(1) I recommend replacing disposable filters at least once a month as part of maintenance. Failure
to replace disposable filters can cause the blower fan to fail.
![]() 4.2 Item 1(Picture) ![]() 4.2 Item 2(Picture) |
|
(2) Air handler coil fins displayed damage commensurate with age. The damaged fins may restrict
airflow and decrease the system's efficiency. Have the coils further inspected and corrected
by a qualified HVAC contractor.
![]() 4.2 Item 3(Picture) ![]() 4.2 Item 4(Picture) ![]() 4.2 Item 5(Picture) ![]() 4.2 Item 6(Picture) |
4.3 |
Presence of Installed Heat Source in Each Room
Comments: |
4.4 |
Cooling and Air Handler Equipment and Normal Operating Controls
Comments: |
4.5 |
Cooling Equipment Findings
Comments: |
The AC system responded properly to normal operating controls. The difference in
temperatures of the supply and return air was between 14 degrees and 22 degrees which
indicated that the unit was cooling as intended. This indicated a proper differential temperature
of the system.
![]() 4.5 Item 1(Picture) |
4.6 |
Presence of Installed Cooling Source in Each Room
Comments: |
5.0 |
Venting Systems (Kitchens, Baths and Laundry)
Comments: |
5.1 |
Insulation Behind Finished Walls
Comments: |
Insulation could not be visibly and physically observed due to finished wall construction but
thermal imaging indicated that insulation was installed behind finished walls.
|
5.2 |
Dryer Vent Line
Comments: |
I recommend cleaning the dryer vent pipe before or upon moving. This maintenance item
should be performed on a yearly basis.
|
6.0 |
Refrigerator
Comments: |
The unit was cooling during the inspection. Care should be taken to clean the refrigerator's
cooling vanes (located under the refrigerator behind the snap off access door) twice a year to
ensure proper and efficient operation of the refrigerator and as a guard against mold
formation.
Note: there was no ice in the fridge area. Ask seller to confirm it works or have it repaired by a qualified appliance contractor. ![]() 6.0 Item 1(Picture) ![]() 6.0 Item 2(Picture) ![]() 6.0 Item 3(Picture) ![]() 6.0 Item 4(Picture) |
6.1 |
Dishwasher
Comments: |
Dishwasher was operated through a complete cycle and no signs of leakage were observed.
The dishwasher had a proper drip loop and the discharge hose was tied to the sink tailpiece.
![]() 6.1 Item 1(Picture) |
6.2 |
Food Waste Disposer
Comments: |
6.3 |
Range Hood (s)
Comments: |
Range hood is integral to the built-in microwave and is a recirculating type, rather than a
vented type. In the event of heavy cooking smoke, some of the smoke may re-enter the kitchen
via the re-circulation vent. With re-circulating type range hoods, care must be taken to
regularly (bi-monthly) clean the metal grease filter located under the hood in order to ensure
proper operation of the unit.
![]() 6.3 Item 1(Picture) |
6.4 |
Microwave Cooking Equipment
Comments: |
6.5 |
Ranges/Ovens/Cooktops
Comments: |
(1)
As a safety precaution the inspector recommends installing an anti-tip bracket behind the stove
to prevent anything heavy positioned in the oven door to tip over and cause serious injury to
children, adults and pets.
Installation should be followed using the manufacturers recommendations. These parts are barely available at local hardware stores. Recommend to order this part from the manufacturer if not provided by the seller. ![]() 6.5 Item 1(Picture) ![]() 6.5 Item 2(Picture) |
|
(2) Oven operated during the inspection.
![]() 6.5 Item 3(Picture) |
6.6 |
Washer
Comments: |
The washer operated properly through a complete cycle without water leaks.
|
6.7 |
Dryer
Comments: |
Dryer filters must be cleaned before and after each load.
Dryer operated properly and heated when tested. ![]() 6.7 Item 1(Picture) |
221 W Dempster St
Des Plaines, IL, 60016
Customer
Gabriel M
Address
33 N Olcott Ave Unit 301
Chicago IL 60403
1.1 | Walls | |
Repair or Replace, Inspected | ||
I saw one broken tile in the primary bathroom. I recommend that a qualified handyman
contractor corrects the issue.
![]() 1.1 Item 1(Picture) |
1.4 | Doors (representative number) | |
Repair or Replace, Inspected | ||
(1) Main entry door was not equipped with a self closing device. These devices are required to
prevent smoke and fire propagation between exit stairways and apartment.
![]() 1.4 Item 1(Picture) |
||
(2) Balcony screen door was damaged. Have the screen repaired or replaced.
![]() 1.4 Item 2(Picture) |
1.5 | Steps, Stairways, Balconies and Railings | |
Repair or Replace, Inspected | ||
I saw broken tiles on the balcony. Have a qualified handyman contractor correct as needed.
![]() 1.5 Item 1(Picture) |
2.2 | Interior Drain, Waste and Vent Systems | |
Repair or Replace, Inspected | ||
Primary bathroom area shower drain was missing a floor strainer. Have it fixed as necessary.
Interior drain,waste and vent systems operated properly. No signs of leakage, or physical
damage was observed, where it was possible to observe. ![]() 2.2 Item 1(Picture) ![]() 2.2 Item 2(Picture) |
3.4 | Smoke Detectors / Carbon Monoxide Detectors | |
Watch List, Inspected | ||
The smoke and carbon monoxide detectors should be tested at common hallway to bedrooms
upon moving in to home. The actual detector mechanisms in most smoke and carbon monoxide
detectors usually only last 4 to 5 years. Even though the detector may sound when the "test"
button is pushed, this button tests only the battery, not the detector.
Note: more than one unit was not equipped with back up batteries. Have the batteries installed
so the units can operate during a blackout. ![]() 3.4 Item 1(Picture) |
4.1 | Normal Operating And Safety Controls | |
Inspected | ||
The thermostat was located in the hallway.
![]() 4.1 Item 1(Picture) |
5.2 | Dryer Vent Line | |
Watch List, Inspected | ||
I recommend cleaning the dryer vent pipe before or upon moving. This maintenance item
should be performed on a yearly basis.
|
6.0 | Refrigerator | |
Watch List, Inspected | ||
The unit was cooling during the inspection. Care should be taken to clean the refrigerator's
cooling vanes (located under the refrigerator behind the snap off access door) twice a year to
ensure proper and efficient operation of the refrigerator and as a guard against mold
formation.
Note: there was no ice in the fridge area. Ask seller to confirm it works or have it repaired by a
qualified appliance contractor. ![]() 6.0 Item 1(Picture) ![]() 6.0 Item 2(Picture) ![]() 6.0 Item 3(Picture) ![]() 6.0 Item 4(Picture) |
6.5 | Ranges/Ovens/Cooktops | |
Watch List, Inspected | ||
(1)
As a safety precaution the inspector recommends installing an anti-tip bracket behind the stove
to prevent anything heavy positioned in the oven door to tip over and cause serious injury to
children, adults and pets.
Installation should be followed using the manufacturers recommendations. These parts are
barely available at local hardware stores. Recommend to order this part from the manufacturer
if not provided by the seller. ![]() 6.5 Item 1(Picture) ![]() 6.5 Item 2(Picture) |
INVOICE |
Condo Home Inspections LLC
221 W Dempster St Des Plaines, IL, 60016 Inspected By: Julio C Patino Pacheco |
Inspection Date: 3/7/2022
Report ID: 20220307-33-N-Olcott-Ave-Unit-301 |
Customer Info: | Inspection Property: |
Gabriel M
Customer's Real Estate Professional: |
33 N Olcott Ave Unit 301 Chicago IL 60403 |
| ||||||||||||
Tax $0.00 | ||||||||||||
Total Price $300.00 |
Payment Method: Credit Card
Payment Status: Paid
Note: