Date: 3/19/2022 | Time: 05:00 PM | Report ID: 20220319-244-King-Dr |
Property: 244 King Dr Skokie IL |
Customer: David Z |
Real Estate Professional: Joshua Novy Telequest Company |
Comment Key or Definitions
This inspection was conducted in accordance with the State of Illinois Home Inspector Licensing Act. The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI) = I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Watch List (WL) = The item, component or unit requires schedule maintenance or monitoring.
Significantly Deficient (SD) = Defined by Illinois State Law as either a) not functioning or b) posing a safety hazard. It should be noted that a large number of significantly deficient items can be addressed at little cost. It is important to remember that the safety of a significantly deficient item is not based upon mere local building codes, which contain 'grandfathering' clauses, or the common 'accepted' practices of tradesmen, but on current national and international safety requirements and with the well being of the property and the client in mind.
Observations:
Text in red denotes an observation that in the inspectors opinion is a safety hazard, needs immediate repair, further evaluation, or is otherwise significantly deficient. These observations should generally be addressed before the close of escrow. You should read the entire report to understand all observations and recommendations.
Please Note: If you have any questions or any thing is unclear, please do not hesitate to contact Condo Home Inspections LLC and/or your specific inspector. We are happy to answer any of your questions.
PHOTOS: Your completed report may contain photographs of various conditions noted during the inspection. Photographs provided in this report are intended to help interested parties understand the context of this report, but may not represent the sum total of all conditions. You must read the entire report.
In Attendance: Customer and their agent | Type of building: Single Family (1 story) | Approximate age of building: Over 25 Years |
Home Faces: East | Temperature: Over 65 (F) = 18 (C) | Weather: Clear |
Ground/Soil surface condition: Dry | Rain in last 3 days: No | Radon Test: No |
Water Test: No | Occupied or Vacant: Vacant |
89
Items Inspected
Total number in report.
21
Summary Comments
Total number in report.
61
Photos
Total number in report.
1.0 |
Roof Coverings
Comments: |
![]() 1.0 Item 1(Picture) ![]() 1.0 Item 2(Picture) ![]() 1.0 Item 3(Picture) |
1.1 |
Underlayment
Comments: |
1.2 |
Flashings
Comments: |
(1) The chimney had no cricket flashing installed. The current condition encourages pooling of
runoff on the uphill side of the chimney, increasing the chance of roof leakage. I recommend
correction performed by a qualified licensed roof contractor.
![]() 1.2 Item 1(Picture) ![]() 1.2 Item 2(Picture) ![]() 1.2 Item 3(Picture) |
|
(2) I recommend adding a diverter flashing at the area where the roof plane meets the vinyl siding
wall. Diverter flashing prevents rainwater shed by the roof from getting behind the siding.
![]() 1.2 Item 4(Picture) ![]() 1.2 Item 5(Picture) |
1.3 |
Skylights, Chimneys and Roof Penetrations
Comments: |
(1) Deteriorated brick and mortar joints around the chimney should be repaired by a qualified
brick mason contractor. Failure to so do will further deteriorate these areas.
Also, the chimney crown has undergone crack repairs that appeared substandard and should be further evaluated by a qualified chimney sweep contractor. ![]() 1.3 Item 1(Picture) ![]() 1.3 Item 2(Picture) ![]() 1.3 Item 3(Picture) |
|
(2) Flashing nails on the roof were not sealed with roof cement and the nails can rust allowing
water intrusion.
![]() 1.3 Item 4(Picture) |
1.4 |
Roof Drainage Systems
Comments: |
Gutters had significant debris and require cleaning. Clogged gutters can cause water intrusion
problems.
![]() 1.4 Item 1(Picture) |
2.0 |
Wall Cladding Flashing and Trim
Comments: |
2.1 |
Windows
Comments: |
2.2 |
Doors (Exterior)
Comments: |
2.3 |
Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings
Comments: |
Balcony wooden deck posts were in contact with soil and the posts can begin to rot overtime.
The posts should rest on a concrete footing above grade level.
![]() 2.3 Item 1(Picture) |
2.4 |
Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building)
Comments: |
Front exterior foundation wall had no clearance from ground. The foundation sill should be
above grade 6 to 8 inches to prevent water seepage in the basement.
![]() 2.4 Item 1(Picture) ![]() 2.4 Item 2(Picture) |
2.5 |
Driveway, Walkways, Carports
Comments: |
Concrete driveway was damaged near the garage door and may pose a trip hazard.
![]() 2.5 Item 1(Picture) |
2.6 |
Eaves, Soffits and Fascias
Comments: |
2.7 |
Exterior Wall Vents
Comments: |
2.8 |
Outdoor Shed
Comments: |
2.9 |
Exterior Fence
Comments: |
3.0 |
Garage Wall Cladding
Comments: |
3.1 |
Garage window (s)
Comments: |
3.2 |
Garage Roof
Comments: |
3.3 |
Garage Roof Structure
Comments: |
3.4 |
Garage Ceilings
Comments: |
3.5 |
Garage Walls (including Firewall Separation)
Comments: |
3.6 |
Garage Floor
Comments: |
3.7 |
Garage Door (s)
Comments: |
The garage door should have a grab bar so it's easier to lift manually during an emergency.
Lack of a grab bar may cause finger injury too. I recommend installation.
![]() 3.7 Item 1(Picture) |
3.8 |
Garage Door Photo - Electric Eyes
Comments: |
3.9 |
Garage Door Operators (Report whether or not doors will reverse when met with resistance)
Comments: |
3.10 |
Occupant Door (from garage to inside of home)
Comments: |
I recommend that the door leading into the garage area be equipped with spring hinges or an
automatic door closer. This is a standard practice for attached garages. Lack of this device
poses a safety risk.
![]() 3.10 Item 1(Picture) ![]() 3.10 Item 2(Picture) |
3.11 |
Presence of HVAC Ducts Inside The Garage
Comments: |
4.0 |
Ceilings
Comments: |
Minor ceiling damage was seen at the main entry closet. This is for your information only.
![]() 4.0 Item 1(Picture) |
4.1 |
Walls
Comments: |
4.2 |
Floors
Comments: |
4.3 |
Windows (representative number)
Comments: |
Interior windows displayed no signs of cracked glass or condensation stains. All windows
operated properly when tested.
|
4.4 |
Doors (representative number)
Comments: |
The balcony door lock did not work when tested. Have it repaired or replaced as needed.
![]() 4.4 Item 1(Picture) |
4.5 |
Steps, Stairways, Balconies and Railings
Comments: |
4.6 |
Counters and Cabinets (representative number)
Comments: |
4.7 |
Pests & Rodents
Comments: |
Mice droppings were seen behind the stove. I recommend hiring a pest control company to
evaluate and perform treatment.
![]() 4.7 Item 1(Picture) |
4.8 |
Bathroom Vanity Tops & Cabinets
Comments: |
5.0 |
Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Comments: |
There was a foundation crack in the mechanical room (south west corner wall) that may be the
result of differential settling of foundation. I recommend further evaluation and correction
performed by a qualified foundation repair contractor.
![]() 5.0 Item 1(Picture) ![]() 5.0 Item 2(Picture) |
5.1 |
Walls (Structural)
Comments: |
The structural walls were not seen by the inspector, but are assumed to be 2 x 4 wood studs
consistent with the type and style of the construction.
|
5.2 |
Columns, Piers and Beams
Comments: |
Columns piers and beams were not visible due to finished walls and ceilings in the basement.
![]() 5.2 Item 1(Picture) ![]() 5.2 Item 2(Picture) |
5.3 |
Basement Concrete Floor Slab
Comments: |
5.4 |
Floors (Structural)
Comments: |
Structural floors could not be observed because of finished ceilings in the basement
obstructing view.
|
5.5 |
Attic entry
Comments: |
5.6 |
Ceilings (Structural)
Comments: |
5.7 |
Roof Structure and Attic
Comments: |
A portion of the roof deck sheathing was buckled. Also, the front end of the roof sagged which
may be an indication of rafter or truss spread. I recommend the roof be further evaluated and
corrected by a qualified licensed roof and structural framing contractor.
![]() 5.7 Item 1(Picture) ![]() 5.7 Item 2(Picture) ![]() 5.7 Item 3(Picture) |
6.0 |
Main Water Shut-off Device (Describe location)
Comments: |
The main water shut off was found in the mechanical room.
![]() 6.0 Item 1(Picture) |
6.1 |
Interior Water Supply, Distribution System
Comments: |
The distribution water pipe system was composed of copper and was properly supported
where it was possible to observe. There were no distribution water leaks during the inspection.
All plumbing fixtures were properly connected to a hot water source.
|
6.2 |
Interior Drain, Waste and Vent Systems
Comments: |
6.3 |
Sump Pump & Ejector Pumps
Comments: |
The sump pump(s) operated properly at the time of the inspection but I recommend the pump
be replaced or equipped with a 120 volt, UPS battery backup and a secondary, 120 volt heavy
duty back up pump so that their operation is assured during periods of electrical blackout.
![]() 6.3 Item 1(Picture) |
6.4 |
Interior Plumbing Fixtures
Comments: |
6.5 |
Whirlpools
Comments: |
6.6 |
Hot Water Systems, Controls, Chimneys, Flues and Vents
Comments: |
The life expectancy for a conventional water heater is approximately 6 to 12 years. This unit
was 13 years old and may need to be replaced soon.
![]() 6.6 Item 1(Picture) |
6.7 |
Hot Water Tank TPR (Temperature Pressure Relief Valve)
Comments: |
6.8 |
Main Fuel Shut-off (Describe Location)
Comments: |
The main fuel shut off was located under the balcony.
![]() 6.8 Item 1(Picture) |
6.9 |
Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks)
Comments: |
6.10 |
Exterior Hose Bibs
Comments: |
7.0 |
Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: |
7.1 |
Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure
Comments: |
(1)
This property had no GFCI protection in many required locations.
Ground fault circuit interrupters known as GFCI's provide protection to people and should be installed in all 125 volt, single phase, 15 or 20 ampere receptacles installed in bathrooms, above kitchen counters, within 6 feet of plumbing lines, garages, laundry rooms, unfinished basements, grade level portions of unfinished accessory buildings used for storage or work areas, and the exterior of houses. I recommend correction performed by a qualified electrician. ![]() 7.1 Item 1(Picture) ![]() 7.1 Item 2(Picture) ![]() 7.1 Item 3(Picture) ![]() 7.1 Item 4(Picture) |
|
(2)
More than one outlet in basement displayed reversed polarity and poses a safety hazard.
I recommend all outlets in the basement be further evaluated and corrected by a qualified electrician. ![]() 7.1 Item 5(Picture) ![]() 7.1 Item 6(Picture) |
7.2 |
Operation of GFCI (Ground Fault Circuit Interrupters)
Comments: |
All GFCI outlets should be tested monthly using the test and reset buttons to ensure proper
operation.
![]() 7.2 Item 1(Picture) |
7.3 |
Operation of AFCI (ARC Fault Circuit Interrupters)
Comments: |
7.4 |
Smoke Detectors / Carbon Monoxide Detectors
Comments: |
This property was not equipped with smoke or carbon monoxide detectors where necessary.
The following locations should have these units installed:
• In the immediate vicinity of bedrooms within 15 feet and not less than 3 feet horizontally from the door or opening of a bathroom. • In all bedrooms • In each story of a dwelling unit, including basements and cellars • Within 20 feet of a kitchen and within 15 feet of gas fired appliances. |
7.5 |
Service Entrance Conductors
Comments: |
7.6 |
Location of Main and Distribution Panels
Comments: |
The electrical panel was located in the rear basement room area.
![]() 7.6 Item 1(Picture) ![]() 7.6 Item 2(Picture) |
7.7 |
Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels
Comments: |
The electrical system was only grounded to a cold metal pipe. The service should be grounded
also to a supplementary ground rod. Properly grounded electrical panels are safer because
they protect against power surges, lightning strikes and ground faults within the electrical home
system. I recommend further evaluation and correction performed by a qualified electrician.
![]() 7.7 Item 1(Picture) ![]() 7.7 Item 2(Picture) |
7.8 |
Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage
Comments: |
The maximum breaker size allowed by the Ruud condenser manufacturing label is 35amps.
The condenser was protected with a 40 Amp double leg circuit breaker and should be
corrected so that the breaker trips if the electrical conductors serving the condenser draw
more than 35 amps. Otherwise, electrical components in the unit can be damaged. Correction
should be performed by a qualified electrician.
![]() 7.8 Item 1(Picture) ![]() 7.8 Item 2(Picture) ![]() 7.8 Item 3(Picture) |
8.0 |
Heating Equipment
Comments: |
The life expectancy for a furnace is approximately 15 to 25 years. The Trane furnace was 24
years old and is approaching the end of its useful lifespan.
Have the furnace further evaluated and serviced by a qualified HVAC contractor before or upon moving. ![]() 8.0 Item 1(Picture) |
8.1 |
Normal Operating And Safety Controls
Comments: |
The furnace maintenance switch did not work when tested. I recommend repair by a qualified
HVAC contractor.
![]() 8.1 Item 1(Picture) |
8.2 |
Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: |
Heating and air conditioning are distributed by means of rectangular and round galvanized
metal ducts. Observable ducts were properly secured and attached with screws. They
displayed no signs of physical damage or rust. Testing of the furnace system displayed good
balancing of the air flow through return and supply registers. The furnace operated through a
full cycle.
![]() 8.2 Item 1(Picture) |
8.3 |
Presence of Installed Heat Source in Each Room
Comments: |
8.4 |
Chimneys, Flues and Vents (for fireplaces, gas water heaters or heat systems)
Comments: |
8.5 |
Gas/LP Firelogs and Fireplaces
Comments: |
As a safety precaution, I recommend the fireplace undergoes a level 2 inspection performed
by a qualified chimney sweep contractor during the sale or transfer of property.
![]() 8.5 Item 1(Picture) ![]() 8.5 Item 2(Picture) ![]() 8.5 Item 3(Picture) |
8.6 |
Cooling and Air Handler Equipment and Normal Operating Controls
Comments: |
The life expectancy for a condenser unit is approximately 8 to 20 years. The Ruud condenser
was 20 years old.
![]() 8.6 Item 1(Picture) |
8.7 |
Cooling Equipment Findings
Comments: |
Air conditioning system temperature difference was less than 14 degrees which indicated the
condenser was not cooling properly. A qualified HVAC contractor should further evaluate and
correct the condenser.
![]() 8.7 Item 1(Picture) |
8.8 |
Presence of Installed Cooling Source in Each Room
Comments: |
9.0 |
Venting Systems (Kitchens, Baths and Laundry)
Comments: |
9.1 |
Ventilation Fans and Thermostatic Controls in Attic
Comments: |
9.2 |
Ventilation of Attic and Foundation Areas
Comments: |
Signs of fungi or wood deck discoloration and rusted nails indicated improper attic ventilation. I
recommend that the ventilation in the attic be corrected by a qualified general contractor.
![]() 9.2 Item 1(Picture) ![]() 9.2 Item 2(Picture) ![]() 9.2 Item 3(Picture) |
9.3 |
Insulation And Vapor Retarders In Unfinished Spaces
Comments: |
9.4 |
Insulation Behind Finished Walls
Comments: |
Insulation could not be visibly and physically observed due to finished wall construction but
thermal imaging indicated that insulation was installed behind finished walls.
|
9.5 |
Dryer Vent Line
Comments: |
10.0 |
Refrigerator
Comments: |
10.1 |
Dishwasher
Comments: |
10.2 |
Range Hood (s)
Comments: |
10.3 |
Microwave Cooking Equipment
Comments: |
10.4 |
Ranges/Ovens/Cooktops
Comments: |
As a safety precaution the inspector recommends installing an anti-tip bracket behind the stove
to prevent anything heavy positioned in the oven door to tip over and cause serious injury to
children, adults and pets.
Installation should be followed using the manufacturers recommendations. These parts are barely available at local hardware stores. Recommend to order this part from the manufacturer if not provided by the seller. ![]() 10.4 Item 1(Picture) ![]() 10.4 Item 2(Picture) |
10.5 |
Washer
Comments: |
The washer operated properly through a complete cycle without water leaks.
|
10.6 |
Dryer
Comments: |
Dryer filters must be cleaned before and after each load.
Dryer operated properly and heated when tested. |
221 W Dempster St
Des Plaines, IL, 60016
Customer
David Z
Address
244 King Dr
Skokie IL
1.2 | Flashings | |
Repair or Replace, Inspected | ||
(1) The chimney had no cricket flashing installed. The current condition encourages pooling of
runoff on the uphill side of the chimney, increasing the chance of roof leakage. I recommend
correction performed by a qualified licensed roof contractor.
![]() 1.2 Item 1(Picture) ![]() 1.2 Item 2(Picture) ![]() 1.2 Item 3(Picture) |
||
(2) I recommend adding a diverter flashing at the area where the roof plane meets the vinyl siding
wall. Diverter flashing prevents rainwater shed by the roof from getting behind the siding.
![]() 1.2 Item 4(Picture) ![]() 1.2 Item 5(Picture) |
1.3 | Skylights, Chimneys and Roof Penetrations | |
Repair or Replace, Inspected | ||
(1) Deteriorated brick and mortar joints around the chimney should be repaired by a qualified
brick mason contractor. Failure to so do will further deteriorate these areas.
Also, the chimney crown has undergone crack repairs that appeared substandard and should
be further evaluated by a qualified chimney sweep contractor. ![]() 1.3 Item 1(Picture) ![]() 1.3 Item 2(Picture) ![]() 1.3 Item 3(Picture) |
||
(2) Flashing nails on the roof were not sealed with roof cement and the nails can rust allowing
water intrusion.
![]() 1.3 Item 4(Picture) |
1.4 | Roof Drainage Systems | |
Watch List, Inspected | ||
Gutters had significant debris and require cleaning. Clogged gutters can cause water intrusion
problems.
![]() 1.4 Item 1(Picture) |
3.7 | Garage Door (s) | |
Repair or Replace, Inspected | ||
The garage door should have a grab bar so it's easier to lift manually during an emergency.
Lack of a grab bar may cause finger injury too. I recommend installation.
![]() 3.7 Item 1(Picture) |
3.10 | Occupant Door (from garage to inside of home) | |
Significantly Deficient, Inspected | ||
I recommend that the door leading into the garage area be equipped with spring hinges or an
automatic door closer. This is a standard practice for attached garages. Lack of this device
poses a safety risk.
![]() 3.10 Item 1(Picture) ![]() 3.10 Item 2(Picture) |
4.7 | Pests & Rodents | |
Significantly Deficient, Inspected | ||
Mice droppings were seen behind the stove. I recommend hiring a pest control company to
evaluate and perform treatment.
![]() 4.7 Item 1(Picture) |
5.0 | Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | |
Repair or Replace, Inspected | ||
There was a foundation crack in the mechanical room (south west corner wall) that may be the
result of differential settling of foundation. I recommend further evaluation and correction
performed by a qualified foundation repair contractor.
![]() 5.0 Item 1(Picture) ![]() 5.0 Item 2(Picture) |
5.7 | Roof Structure and Attic | |
Repair or Replace, Inspected | ||
A portion of the roof deck sheathing was buckled. Also, the front end of the roof sagged which
may be an indication of rafter or truss spread. I recommend the roof be further evaluated and
corrected by a qualified licensed roof and structural framing contractor.
![]() 5.7 Item 1(Picture) ![]() 5.7 Item 2(Picture) ![]() 5.7 Item 3(Picture) |
6.3 | Sump Pump & Ejector Pumps | |
Repair or Replace, Inspected | ||
The sump pump(s) operated properly at the time of the inspection but I recommend the pump
be replaced or equipped with a 120 volt, UPS battery backup and a secondary, 120 volt heavy
duty back up pump so that their operation is assured during periods of electrical blackout.
![]() 6.3 Item 1(Picture) |
6.6 | Hot Water Systems, Controls, Chimneys, Flues and Vents | |
Repair or Replace, Inspected | ||
The life expectancy for a conventional water heater is approximately 6 to 12 years. This unit
was 13 years old and may need to be replaced soon.
![]() 6.6 Item 1(Picture) |
7.1 | Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure | |
Significantly Deficient, Inspected | ||
(1)
This property had no GFCI protection in many required locations.
Ground fault circuit interrupters known as GFCI's provide protection to people and should be
installed in all 125 volt, single phase, 15 or 20 ampere receptacles installed in bathrooms,
above kitchen counters, within 6 feet of plumbing lines, garages, laundry rooms, unfinished
basements, grade level portions of unfinished accessory buildings used for storage or work
areas, and the exterior of houses. I recommend correction performed by a qualified
electrician. ![]() 7.1 Item 1(Picture) ![]() 7.1 Item 2(Picture) ![]() 7.1 Item 3(Picture) ![]() 7.1 Item 4(Picture) |
||
(2)
More than one outlet in basement displayed reversed polarity and poses a safety hazard.
I recommend all outlets in the basement be further evaluated and corrected by a qualified electrician. ![]() 7.1 Item 5(Picture) ![]() 7.1 Item 6(Picture) |
7.4 | Smoke Detectors / Carbon Monoxide Detectors | |
Significantly Deficient, Inspected | ||
This property was not equipped with smoke or carbon monoxide detectors where necessary.
The following locations should have these units installed:
• In the immediate vicinity of bedrooms within 15 feet and not less than 3 feet horizontally from the door or opening of a bathroom. • In all bedrooms • In each story of a dwelling unit, including basements and cellars • Within 20 feet of a kitchen and within 15 feet of gas fired appliances. |
7.7 | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels | |
Significantly Deficient, Inspected | ||
The electrical system was only grounded to a cold metal pipe. The service should be grounded
also to a supplementary ground rod. Properly grounded electrical panels are safer because
they protect against power surges, lightning strikes and ground faults within the electrical home
system. I recommend further evaluation and correction performed by a qualified electrician.
![]() 7.7 Item 1(Picture) ![]() 7.7 Item 2(Picture) |
7.8 | Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage | |
Repair or Replace, Inspected | ||
The maximum breaker size allowed by the Ruud condenser manufacturing label is 35amps.
The condenser was protected with a 40 Amp double leg circuit breaker and should be
corrected so that the breaker trips if the electrical conductors serving the condenser draw
more than 35 amps. Otherwise, electrical components in the unit can be damaged. Correction
should be performed by a qualified electrician.
![]() 7.8 Item 1(Picture) ![]() 7.8 Item 2(Picture) ![]() 7.8 Item 3(Picture) |
8.1 | Normal Operating And Safety Controls | |
Repair or Replace, Inspected | ||
The furnace maintenance switch did not work when tested. I recommend repair by a qualified
HVAC contractor.
![]() 8.1 Item 1(Picture) |
8.7 | Cooling Equipment Findings | |
Repair or Replace, Inspected | ||
Air conditioning system temperature difference was less than 14 degrees which indicated the
condenser was not cooling properly. A qualified HVAC contractor should further evaluate and
correct the condenser.
![]() 8.7 Item 1(Picture) |
9.2 | Ventilation of Attic and Foundation Areas | |
Repair or Replace, Inspected | ||
Signs of fungi or wood deck discoloration and rusted nails indicated improper attic ventilation. I
recommend that the ventilation in the attic be corrected by a qualified general contractor.
![]() 9.2 Item 1(Picture) ![]() 9.2 Item 2(Picture) ![]() 9.2 Item 3(Picture) |
10.4 | Ranges/Ovens/Cooktops | |
Significantly Deficient, Inspected | ||
As a safety precaution the inspector recommends installing an anti-tip bracket behind the stove
to prevent anything heavy positioned in the oven door to tip over and cause serious injury to
children, adults and pets.
Installation should be followed using the manufacturers recommendations. These parts are
barely available at local hardware stores. Recommend to order this part from the manufacturer
if not provided by the seller. ![]() 10.4 Item 1(Picture) ![]() 10.4 Item 2(Picture) |
INVOICE |
Condo Home Inspections LLC
221 W Dempster St Des Plaines, IL, 60016 Inspected By: Julio C Patino Pacheco |
Inspection Date: 3/19/2022
Report ID: 20220319-244-King-Dr |
Customer Info: | Inspection Property: |
David Z
Customer's Real Estate Professional: Joshua Novy Telequest Company |
244 King Dr Skokie IL |
| ||||||||
Tax $0.00 | ||||||||
Total Price $550.00 |
Payment Method: Credit Card
Payment Status: Paid
Note:
The shingles also displayed black staining. Black staining is caused by algae growth and is a cosmetic issue only. The staining can be removed with special treatment products but doing it yourself puts you at risk of falling from the roof. Hiring a company that specializes in cleaning and restoring asphalt roofs is the best way to go.