RV Location:
2222 Even Happier St, Middle Of, KS
VIN Number: 0ZT0FSJC0M0000000
Extra Mile Mobile RV Services, LLC
Kevin Gleason
11232 Delaware Pkwy
Kansas City, KS 66109
913-557-0033
6.1 | Slideout T-Molding Trim | |
Poor | ||
![]() |
Inspector observed a bare wire protruding from the top rear corner of the slideout T-molding. Recommend repair by a qualified
RV technician.
|
7.0.A | Tire Condition | |
Fair | ||
![]() |
Tire pressure was observed to be 43 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to movement of the RV.
|
7.0.B | Tire Condition | |
Fair | ||
![]() |
Tire was found to be inflated to 44.5 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to first movement in case the tire is needed.
|
7.0.C | Tire Condition | |
Fair | ||
![]() |
Tire was found to be inflated to 42.7 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to first movement.
|
15.1 | Water Heater - Rubber Grommet Around Gas Line Sealed | |
Poor | ||
![]() |
Inspector observed no high temperature sealant was applied over gas line rubber grommet. Recommend sealant be applied over
rubber grommet by a qualified RV technician to prevent possible LP leakage into the living space.
|
2.1 | Front Cap, Joints and Seals | |
Poor | ||
![]() |
Inspector observed significant seal cracks on the curbside half of the front cap seal. Recommend these areas be repaired by a
qualified RV technician.
|
2.6 | Exterior Vent Covers | |
Poor | ||
![]() |
MaxxAir vent cover sealant has multiple cracks and points of sealant damage. Recommend these areas be repaired by a
qualified RV technician to prevent water intrusion.
|
2.7 | Plumbing Vent Covers | |
Poor | ||
![]() |
Both plumbing vent covers have sealant that is cracked and separating from the base of the covers. Recommend these areas
be repaired by a qualified RV technician.
|
2.8 | Skylights | |
Poor | ||
![]() |
Shower skylight cover sealant cracked at multiple points along streetside and rear edges. Recommend these areas be repaired
by a qualified RV technician to prevent water intrusion.
|
2.12 | Solar Panels | |
Poor | ||
![]() |
(1) Solar panel mounting bracket sealant shows signs of cracking. Recommend these areas be repaired by a qualified RV
technician.
|
|
![]() |
(2) Solar panel cable connection bracket sealant has a crack and hole. Recommend these areas be repaired by a qualified RV
technician.
|
2.13 | Ladder - Roof Access | |
Poor | ||
![]() |
Right ladder handle sealant has a hole on rear cap side. Recommend this area be repaired by a qualified RV technician.
|
2.3 | Rear Cap, Joints and Seals | |
Fair | ||
![]() |
Rear cap seal has multiple bubble holes and signs of scuffing near the ladder. Recommend these areas be repaired by a
qualified RV technician.
|
3.0.B | Sidewall Condition | |
Fair | ||
![]() |
(2) Inspector observed that the curbside wheel well cover was cracked behind the third and fourth screws as counted from the front.
Recommend repair by a qualified RV technician.
|
3.3.B | Cargo/Access Doors | |
Fair | ||
![]() ![]() |
Curbside cargo access door frame slightly bent. Door operation is not affected.
|
4.0.A | Door Condition | |
Fair | ||
![]() ![]() |
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV
technician.
|
13.1 | LP Leak System Test | |
Acceptable | ||
![]() |
Inspector performed an LP Leak Drop Test on the propane system. The system should charge to 11" WC, but this system was
charging to 13" WC.When the system was bled down to 8" WC, no drop was detected after five minutes. Recommend the
propane system be evaluated and repaired by a qualified RV technician to address the overcharging condition.
|
17.24 | Windows - Window Coverings | |
Yes | ||
![]() |
Valance over large dinette window is no longer held in place by its mounting screws. The valance was located on the dinette
table at the time of the inspection and is in acceptable condition to be re-mounted.
|
3.3.B | Cargo/Access Doors | |
Fair | ||
![]() ![]() |
Curbside cargo access door frame slightly bent. Door operation is not affected.
|
4.0.A | Door Condition | |
Fair | ||
![]() ![]() |
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV
technician.
|
5.1 | Fabric Condition | |
Acceptable | ||
![]() |
(1) Inspector observed multiple areas of slight discoloration on top of awning.
|
|
![]() |
(2) Inspector observed multiple areas of slight discoloration on bottom of awning.
|
11.14 | Polarity / Voltage Test - Receptacle Behind Refrigerator | |
Not Inspected | ||
![]() |
The receptacle behind the refrigerator was not accessible due to the fixed 12V refrigerator that had no access to the rear of the
unit.
|
12.3 | On-Board Water System: Tank, Water Pump and Fixtures for Tank Fill Condition | |
Acceptable | ||
![]() |
(1) Inspector observed the fresh water tank electric heating pad is separating from the underside of the tank. Recommend the pad
be repaired by a qualified RV technician.
|
|
![]() |
(2) Fresh Water Fill Receptacle Photos
|
12.6 | Gray Water Tank #1 | |
Acceptable | ||
![]() |
Inspector observed the gray water tank electric heating pad is separating from the underside of the tank. Recommend the pad
be repaired by a qualified RV technician.
|
14.0 | Refrigerator - User Control Panel | |
Acceptable | ||
![]() |
Inspector noted that the refrigerator and freezer had still not cooled down to the recommended temperature ranges for safe food
storage after 24 hours of continuous operation. The outside temperature at the time of testing was 102 Degrees.
|
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.
Inspection Date / Year,Make,Model : 07/28/2022 2021 Fleetwood E-Pro E20BHS | Time: 06:30 AM | VIN Number: 0ZT0FSJC0M0000000 |
RV Location: 2222 Even Happier St, Middle Of, KS |
Customer: RV Inspection Sample Report (Towable) |
|
This time sensitive document was prepared for the client listed on the Cover Page of this report. Any reproduction, use, or resale of this document by individuals other than who is listed on the report cover page, or their assigns, is not supported by the inspector and company.
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this RV home. Any recommendations by the inspector to repair suggests a second opinion or further inspection by a qualified RV technician. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase.
Acceptable (A) = A visually observed item, component or unit and if no other comments were made then it appeared to be performing its intended function with little or no deterioration visible.
Fair (F)= The item or its components is not in need of immediate repair as it is performing its intended function but deterioration is visible. Some opinions may elect to repair or replace this item now while others may wait.
Poor (P) = The item, component or unit is not functioning as intended and replacement is recommended, or needs further evaluation by a qualified RV technician.
Not Inspected (NI)= The item, unit or component was not inspected, and no representations were made as to whether or not it was functioning as intended and a statement for the reason for not inspecting may be made.
Not Present (NP) = This item, component or unit is not in this RV.
NRVIA Standards of Practice
Purpose, Scope and General Statements
1 – The purpose of the Standards of Practice is to establish a uniform standard for the companies RV Inspector to inspect and report in an objective manner the conditions of a Recreational Vehicle and its components.
2 – The Standards describe the components, and systems included in an RV Inspection.
3 – The Standards apply to motorized and towable types of RVs as defined by the RV Industry.
4 – The Standards apply to a visual inspection of those areas, components and systems that are readily accessible to determine at the time of inspection that they are performing their intended function without regard to life expectancy.
5 – The purpose of the RV inspection is to identify visible and operational defects as permitted by the current conditions that in the judgment of the RV Inspector will adversely affect the function or integrity of the items, components and systems of the Recreational Vehicle.
6 – RV Inspections performed under the Standards of Practice are basically visual and rely upon the opinion, judgment, education and experience of the RV Inspector and are not intended to be technically exhaustive.
7 – RV Inspections shall be performed in a time period sufficient to allow compliance with the provisions of the NRVIA Standards of Practice.
8 – RV Inspections performed under the Standards shall not be construed as being a compliance inspection of any code, governmental regulation or manufacturer’s installation instructions or procedures. In the event a law, statute or ordinance prohibits a procedure recommended in the Standards, the RV Inspector is relieved of the obligation to adhere to the prohibited part of the Standards.
9 – RV Inspections performed under the Standards are not an expressed, implied warranty or guarantee of adequacy, performance or useful life of any RV, any of its components or systems.
10 – Only those items specifically listed on the RV Inspection Report will be included in the RV Inspectors evaluation.
11 – The RV Inspector shall report any system or component included in the Standards of Practice which were present at the time of the RV Inspection but were NOT inspected and provide the reason they were not inspected.
General Limitations and Exclusions
1 – RV Inspections performed under the companies Standards of Practice exclude any items concealed or not readily accessible to the RV Inspector. The RV Inspector is not required to move furniture, personal or stored items. Lifting floor covering, accessing interior walls and ceilings in which could damage or destroy the components or systems being evaluated is not part of the RV Inspection.
2 – The determination of the presence of damage caused by insects or water is only to be evaluated by observation with an opinion being rendered by RV Inspector that is to make the client aware of the issue.
3 – Excluded from the Standards of Practice is the determination of indoor air quality of the RV and it’s consequence of physical damage, toxicity, odors, waste products and noxiousness.
4 – The RV Inspection and report are opinions only that are based upon the visual observation of the existing conditions of the RV at the time of the RV Inspection. The report is not intended to be or construed as a guarantee, warranty or any form of insurance. The RV Inspector will not be responsible for any repairs or replacement with regard to the RV or its contents.
5 – The RV Inspector is not required to enter any premises that visibly show a threat to the safety of the RV Inspector or others nor inspect any area or component that poses a danger to the RV Inspector or others.
6 – The NRVIA Certified RV Inspector will inspect and report on the RV items listed in this report and their condition during the RV Inspection. Any additional items of inspection will be dependent upon any agreements that are made between the client and the RV Inspector.
Weather: Partly Cloudy | Type of Inspection: Seller: RV Inspection for Potential Buyer | Style of RV: Travel Trailer |
RV Status: Occupied at the Time of the Inspection | Client Is Present: Yes | Start Temperature: 75 degrees |
VIN Number:
Photo Included VIN #: : 0ZT0FSJC0M0000000 |
VIN Location:
Streetside Front |
RVIA / Canadian Seal Number:
Located by Entrance Door Seal Number / Other Info : SA000000 |
Gross Vehicle Weight Rating (GVWR):
From Data Plate Specify in lbs or kg : 4,355 lbs |
Brand of RV:
Manufacturer's Brand Name Brand Name : E-Pro by Flagstaff |
Model Number:
RV Designation/Floorplan Model Number : E20BHS |
Manufacturer Name and Location:
Forest River Location: City, State : Millersburg, IN |
Date of Manufacturer:
July Year : 2021 |
State Inspection Sticker Current:
Not Required |
State License Plate Current:
Yes State and Plate Number : Kansas - 000AAA |
1.0 |
Vehicle Data
|
(1) Manufacturer's VIN Data Plate Photo
![]() VIN Data Plate
|
|
(2) RVIA Seal Photo
![]() RVIA Seal
|
|
(3) State License Plate Photo
![]() Kansas License Plate
|
|
(4) Owner Stated Comments:
1. Owner stated that he has two mattresses and a ladder for the bunkhouse. All three are like new and never used. 2. Owner stated that he never had a keyless door lock code for the front entrance door, nor was a code sticker located inside the lock as listed on the manufacturers website. The issue was not resolved during a phone call with manufacturer customer support. The door lock and deadbolt work as intended with a key. |
|
(5) Weather the Day of the Inspection: Weather on the day of the inspection was partly cloudy with temperatures starting in the low 80's and rising to mid 90's. |
Roof Type:
Rubber (TPO) |
Areas of Possible Water Intrusion:
Yes |
Roof Ladder Type:
Mounted |
Number of Solar Panels:
One |
TV Antenna - Cleaned and Maintained:
Yes |
Equipment Removed:
No |
2.0 |
Roof Condition
Comments: Acceptable |
Roof Overview Photos
![]() Roof Overview - Front to Back
![]() Roof Overview - Back to Front
|
2.1 |
Front Cap, Joints and Seals
Comments: Poor |
![]() |
Inspector observed significant seal cracks on the curbside half of the front cap seal. Recommend these areas be repaired by a
qualified RV technician.
![]() Front Cap Seal Looking from Front Curbside Joint
![]() Front Cap Seal Near Curbside Joint
|
2.2 |
Trim Rail (Curbside)
Comments: Acceptable |
2.3 |
Rear Cap, Joints and Seals
Comments: Fair |
![]() |
Rear cap seal has multiple bubble holes and signs of scuffing near the ladder. Recommend these areas be repaired by a
qualified RV technician.
![]() Rear Cap Seal Right of the Ladder
![]() Rear Cap Seal Between Ladder Handles
|
2.4 |
Trim Rail (Streetside)
Comments: Acceptable |
2.5 |
Vents - Manual Crank (14 x 14)
Comments: Acceptable |
2.6 |
Exterior Vent Covers
Comments: Poor |
![]() |
MaxxAir vent cover sealant has multiple cracks and points of sealant damage. Recommend these areas be repaired by a
qualified RV technician to prevent water intrusion.
![]() MaxxAir Vent Cover Sealant with Exterior Cover Removed
![]() MaxxAir Cover Sealant With Cover in Place
|
2.7 |
Plumbing Vent Covers
Comments: Poor |
![]() |
Both plumbing vent covers have sealant that is cracked and separating from the base of the covers. Recommend these areas
be repaired by a qualified RV technician.
![]() Rear Plumbing Vent Cover
![]() Front Plumbing Vent Cover
|
2.8 |
Skylights
Comments: Poor |
![]() |
Shower skylight cover sealant cracked at multiple points along streetside and rear edges. Recommend these areas be repaired
by a qualified RV technician to prevent water intrusion.
![]() Skylight Cover
|
2.9 |
Air Conditioner #1 (Shroud)
Comments: Acceptable |
2.10 |
Air Conditioner #1 (Exterior Coils)
Comments: Acceptable |
2.11 |
TV Antenna Exterior Roof Unit
Comments: Acceptable |
2.12 |
Solar Panels
Comments: Poor |
![]() |
(1) Solar panel mounting bracket sealant shows signs of cracking. Recommend these areas be repaired by a qualified RV
technician.
![]() |
![]() |
(2) Solar panel cable connection bracket sealant has a crack and hole. Recommend these areas be repaired by a qualified RV
technician.
![]() Solar Panel Cable Connection Bracket
|
2.13 |
Ladder - Roof Access
Comments: Poor |
![]() |
Right ladder handle sealant has a hole on rear cap side. Recommend this area be repaired by a qualified RV technician.
![]() Ladder Handle Mounts on Roof
|
Exterior Wall Surface Type:
Molded Fiberglass Cap Fiberglass with Decals |
Any Damage or Discoloration or Delamination?:
No |
Windows:
Glass with No Frame |
Cargo Doors:
None |
3.0.A |
Sidewall Condition
Comments: Acceptable |
Front Cap Wall Photo
![]() Front Cap Wall
|
3.1.A |
Paint and/or Decals
Comments: Acceptable |
3.2.A |
Windows
Comments: Acceptable |
Exterior Wall Surface Type:
Fiberglass with Decals |
Any Damage or Discoloration or Delamination?:
No |
Windows:
Glass with No Frame |
Cargo Doors:
Doors with Keyed Twist Latch |
3.0.B |
Sidewall Condition
Comments: Fair |
(1) Curbside Sidewall Photo
![]() Curbside Sidewall
|
|
![]() |
(2) Inspector observed that the curbside wheel well cover was cracked behind the third and fourth screws as counted from the front.
Recommend repair by a qualified RV technician.
![]() Curbside Wheel Well
![]() Curbside Wheel Well
|
3.1.B |
Paint and/or Decals
Comments: Acceptable |
3.2.B |
Windows
Comments: Acceptable |
3.3.B |
Cargo/Access Doors
Comments: Fair |
![]() ![]() |
Curbside cargo access door frame slightly bent. Door operation is not affected.
![]() Curbside Cargo Access Door
![]() |
Exterior Wall Surface Type:
Fiberglass with Decals |
Any Damage or Discoloration or Delamination?:
No |
Windows:
Glass with No Frame |
Cargo Doors:
Doors with Keyed Lock Doors with Keyed Twist Latch |
3.0.C |
Sidewall Condition
Comments: Acceptable |
Streetside Sidewall Photos
![]() Streetside Sidewall (Front)
![]() Streetside Sidewall (Rear)
|
3.1.C |
Paint and/or Decals
Comments: Acceptable |
3.2.C |
Windows
Comments: Acceptable |
3.3.C |
Cargo/Access Doors
Comments: Acceptable |
Exterior Wall Surface Type:
Fiberglass with Decals |
Any Damage or Discoloration or Delamination?:
No |
Windows:
None |
Cargo Doors:
None |
3.0.D |
Sidewall Condition
Comments: Acceptable |
Rear Cap/Wall Photo
![]() Rear Cap/Wall
|
3.1.D |
Paint and/or Decals
Comments: Acceptable |
Type of Entrance Door:
Fiberglass |
Keyless Entry Door Lock System:
Yes |
Keyless Entry Door Lock Functional:
No |
Keyed Door Lock / Deadbolt Functional:
Yes |
Type of Step System:
Manual |
Number of Steps:
Two |
Grab Bar Type:
D-Ring Handle |
4.0.A |
Door Condition
Comments: Fair |
![]() ![]() |
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV
technician.
![]() Front Entry Door Handle
|
Type of Entrance Door:
Fiberglass |
Keyed Door Lock / Deadbolt:
Yes |
Keyed Door Lock / Deadbolt Functional:
Yes |
4.0.B |
Door Condition
Comments: Acceptable |
Awning Material:
Vinyl |
Operational Type:
Electric |
5.0 |
Frame and Latching Mechanism
Comments: Acceptable |
5.1 |
Fabric Condition
Comments: Acceptable |
![]() |
(1) Inspector observed multiple areas of slight discoloration on top of awning.
![]() Top of Awning
|
![]() |
(2) Inspector observed multiple areas of slight discoloration on bottom of awning.
![]() Awning Bottom
![]() Awning Botom
|
5.2 |
Awning Operation
Comments: Acceptable |
Slideout Roof Type:
(TPO) Rubber |
Slideout Drive System:
Lippert Schwinteck w/In-wall Electric Motor |
6.0 |
Slideout Roof
Comments: Acceptable |
Slideout Roof was found to be in acceptable condition.
![]() Slideout Roof
|
6.1 |
Slideout T-Molding Trim
Comments: Poor |
![]() |
Inspector observed a bare wire protruding from the top rear corner of the slideout T-molding. Recommend repair by a qualified
RV technician.
![]() Top Rear Corner of Slideout
|
6.2 |
Seals, Sweeps and Gaskets
Comments: Acceptable |
Slideout Seals, Sweeps, and Gasket Photos
![]() Slideout Top
![]() Slideout Top Front Corner
![]() Slideout Top Rear Corner
![]() Top Rear Seals and Sweeps
|
6.3 |
Slide Rail Gear Rack System
Comments: Acceptable |
Schwinteck Rail Photos
![]() Bottom Rear Schwinteck Rail
![]() Bottom Rear Slide Rail
|
6.4 |
Wiring Harness under Slideout
Comments: Acceptable |
6.5 |
12-Volt DC Control and Switches
Comments: Acceptable |
6.6 |
Slideout Operation and Alignment
Comments: Acceptable |
Slide Photos
![]() Slide Extended (Rear)
![]() Slide Extended (Front)
![]() ![]() Slide Retraction Video
|
Tire Brand:
Westlake |
Tire Size:
Other Other Size : 235/75R15 |
DOT Date:
Visually Verified Enter wwyy : 1521 |
Load Capacity:
Single Tire Rating Enter lbs or kg Weight Rating : 2,340 lbs |
Load Range:
Other Extra Info : C |
RV Manufacturer's Recommended Inflation Air Pressure:
Other PSI : 50 |
Current Air Pressure in Tire:
Tire Gauge Reading (psi) PSI : 43 |
Valve Extensions Installed?:
No |
Tire Pressure Monitors Installed?:
Yes |
7.0.A |
Tire Condition
Comments: Fair |
![]() |
Tire pressure was observed to be 43 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to movement of the RV.
![]() Curbside Tire Pressure Measurement
|
7.1.A |
Tire Tread Condition
Comments: Acceptable |
The curbside tire condition was found to be acceptable.
![]() Curbside Tire
|
Tire Brand:
Westlake |
Tire Size:
Other Other Size : 235/75R15 |
DOT Date:
Visually Verified Enter wwyy : 4620 |
Load Capacity:
Single Tire Rating Enter lbs or kg Weight Rating : 2340 PSI |
Load Range:
Other Extra Info : C |
RV Manufacturer's Recommended Inflation Air Pressure:
Other PSI : 50 |
Current Air Pressure in Tire:
Tire Gauge Reading (psi) PSI : 44.5 |
Valve Extensions Installed?:
No |
Tire Pressure Monitors Installed?:
No |
7.0.B |
Tire Condition
Comments: Fair |
![]() |
Tire was found to be inflated to 44.5 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to first movement in case the tire is needed.
![]() Spare Tire Pressure Measurement
![]() Spare Tire
|
7.1.B |
Tire Tread Condition
Comments: Acceptable |
Tire Brand:
Westlake |
Tire Size:
Other Other Size : 235/75R15 |
DOT Date:
Visually Verified Enter wwyy : 1521 |
Load Capacity:
Single Tire Rating Enter lbs or kg Weight Rating : 2340 lbs |
Load Range:
Other Extra Info : C |
RV Manufacturer's Recommended Inflation Air Pressure:
Other PSI : 50 |
Current Air Pressure in Tire:
Tire Gauge Reading (psi) PSI : 42.7 |
Valve Extensions Installed?:
No |
Tire Pressure Monitors Installed?:
Yes |
7.0.C |
Tire Condition
Comments: Fair |
![]() |
Tire was found to be inflated to 42.7 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure
of 50 PSI per the data plate located on the streetside front sidewall prior to first movement.
![]() Streetside Tire Pressure Measurement
|
7.1.C |
Tire Tread Condition
Comments: Acceptable |
The streetside tire tread was found to be acceptable.
![]() Streetside Tire
|
Note: Due to insurance restrictions, the RV can NOT be driven by the inspector. Also, due to the lack of clearance under the trailer and safety concerns, the inspector will conduct the following visual inspections from the outer perimeter of the towable RV.
Axle Type:
Torsion Axle |
Number of Axles:
One |
Front Axle Weight Rating:
Listed in lbs or kg Weight Rating : 3,900 lbs |
Axle - Did Inspector Check for Visible Signs of Rust?:
Yes Was rust present (Yes or No)? : Yes |
Axle - Did Inspector Check for Visible Signs of Bent or Damaged Components?:
Yes Was damage present? : No |
Axle - Did Inspector Check for Visible Signs of Oil Stains?:
Yes Was any present? : No |
Brake Type:
Electric |
Suspension Bolts with or without Zerk Fittings Have been Evaluated:
Yes |
Frame - Did Inspector Check for Visible Signs of Rust?:
Yes Was any present? : Yes |
Frame - Did Inspector Check for Visible Signs of Bent or Damaged Components?:
Yes Was any present? : No |
Frame - Did Inspector Check for any Visible Signs of Oil Stains?:
Yes Was any present? : No |
8.0 |
Running Gear - Condition
Comments: Acceptable |
Running Gear Photos
![]() Curbside Running Gear
![]() Streetside Running Gear
|
8.1 |
Frame - Condition
Comments: Acceptable |
Frame Photos |
Travel Trailer - Tongue Jack:
Electric |
Travel Trailer - Coupler Operational:
Yes |
Travel Trailer - Safety Chains:
Yes |
Travel Trailer - Stabilizer:
Manual |
Travel Trailer - Weight Distribution System:
Yes |
Travel Trailer - Sway Control System:
Yes |
Inspect for Visible Signs of Damage:
Yes |
Ensure Jacks Extend and Retract Fully:
Yes |
Inspect for Leaks or Mechanical Issues:
Yes |
9.0 |
Travel Trailer Tongue Jack Condition
Comments: Acceptable |
The trailer tongue jack and front stabilizers were found to be in acceptable condition.
![]() Trailer Tongue Jack and Front Stabilizer Jacks
![]() Rear Stabilizing Jacks
|
The inspector tested the Break Away switch by pulling the break away cable and listened for a click or hum at the wheel assemblies, and also checked DC amperage at the Break Away switch. However, this does not indicate that the brakes engaged at all wheel assemblies. It is recommended that the trailer be attached to a tow vehicle and with the Break Away switch engaged, test resistance to movement. The best way to be sure this system is functioning is to have the wheels pulled and the brakes be evaluated by a qualified RV technician.
10.0 |
7-Pin Cord
Comments: Yes |
Seven Pin Cord Photo
![]() Seven Pin Cord Connector
|
10.1 |
Break Away Switch
Comments: Yes |
The break away switch was tested and found to be acceptable.
![]() Breakaway Switch Test
|
10.2 |
Front Clearance Lights
Comments: Yes |
Clearance Light Photos
![]() Front Curbside Clearance Light
![]() Front Streetside Clearance Light
|
10.3 |
Rear Clearance Lights
Comments: Yes |
Rear Clearance Light Photo
![]() Rear Clearance and Tail Lights
|
10.4 |
Streetside - Marker Lights
Comments: Yes |
Streetside Marker Light Photos
![]() Streetside Front Marker Light
![]() Streetside Rear Marker Light
|
10.5 |
Curbside - Marker Lights
Comments: Yes |
Curbside Marker Light Photos
![]() Curbside Front Marker Light
![]() Curbside Rear Marker Light
|
10.6 |
Left Turn and Brake Light
Comments: Yes |
Left Turn Signal Photo
![]() Left Turn Signal Light
|
10.7 |
Right Turn and Brake Light
Comments: Yes |
Right Turn Signal Photo
![]() Right Turn Signal
|
10.8 |
Hitch Lights
Comments: Yes |
Hitch Light Photo
![]() Hitch Light
|
10.9 |
Compartment Lights
Comments: Yes |
Storage Compartment Lights
![]() Storage Compartment Lights
|
10.10 |
Porch Lights
Comments: Yes |
Porch and Awning Light Photos
![]() Awning Light
![]() Porch Light
|
10.11 |
Security Lights
Comments: Yes |
Front Security Light Photo
![]() Front Security Light
|
Power Source:
30 Amp / 120 Volts AC |
Power Cord Condition:
Acceptable |
Inside Electrical Panel Box Condition:
Acceptable |
12 Volt DC Fuse Panel Box Condition:
Acceptable |
Fuses Condition:
All Operational |
Fuse Connections Condition:
Good Connection |
Wires and Terminals Tight:
Solid Connection |
GFCI Testing - Circuit Breaker Panel Box:
Not Present |
GFCI Testing - Bathroom:
Pass |
GFCI Testing - Kitchen:
Pass |
Power Converter - AC On:
Operational Test DC Voltage with Shore Power On : 13.7 |
Power Converter - AC Off:
Operational Test DC Voltage with Shore Power Off : 12.7 |
Power Converter - Verified:
Acceptable |
Inverter - Brand:
Other Other : WFCO |
Inverter - Model:
From Manufacturer's Label Model # : WF-5110RS |
Inverter - Serial:
From Manufacturer's Label Serial # : AC08T213602130 |
Inverter - General Condition:
Acceptable |
Inverter Voltage Output:
Voltage Measured Under 50 Percent Load Voltage Reading in AC Volts : 113 |
Inverter Frequency Output:
Frequency Measured Under Load Frequency Reading in Hertz : 60 |
12 Volt DC House Battery - Location:
Other Location of Battery Stack : On the tongue between the propane tanks and the front cap |
12 Volt DC House Battery - Box Condition:
Acceptable |
12 Volt DC House Battery - Cables and Terminals Condition:
Acceptable |
12 Volt DC House Battery - Vented and Secure:
Yes |
12-Volt DC House Battery - Water Level in Batteries:
Acceptable |
11.0 |
Hot Skin Test - Was any Frame and Running Gear Voltage Recorded
Comments: No |
11.1 |
Hot Skin Test - Was any Exterior Wall Surface Voltage Recorded
Comments: No |
One inspection point of the Hot Skin Test performed on the slideout.
![]() Slideout Hot Skin Test
|
11.2 |
Hot Skin Test - Was any Door Handles and Frames Voltage Recorded
Comments: No |
11.3 |
Hot Skin Test - Was any Window Frames and Trim Voltage Recorded
Comments: No |
11.4 |
Hot Skin Test - Was any Other Voltage Recorded
Comments: No |
11.5 |
Power Cord Inspected
Comments: Yes |
The 30 Amp power cord was observed to be in acceptable condition with no signs of damage or corrosion.
![]() 30 Amp Power Cord (Pedestal End)
![]() Power Cord (RV End)
![]() RV Power Cord Receptacle
|
11.6 |
Electrical Panel Box - Signs of Repair or Service
Comments: No |
Electrical Panel Box with converter mounted to the rear as observed by the fan.
![]() Electrical Panel Box
|
11.7 |
Electrical Panel Box - Circuit Breakers in Place
Comments: Yes |
11.8 |
Electrical Panel Box - Wiring with Signs of Discoloration from Heat
Comments: No |
11.9 |
Electrical Panel Box - Wiring Secure
Comments: Yes |
The 120 VAC side of the electrical panel box was in acceptable condition with no sign of heat damage or mis-wiring.
![]() Electrical Panel Box, 120VAC Side
|
11.10 |
Electrical Panel Box - All White, Black and Ground Wires Kept Separate
Comments: Yes |
11.11 |
Fuse Panel Box Inspected
Comments: Yes |
All fuses in the 12VDC fuse panel box were found to be acceptable.
![]() Electrical Panel Box, 12VDC Side
|
11.12 |
Polarity / Voltage Test - All Exterior Receptacles
Comments: Yes |
The exterior electrical receptacle has acceptable voltage and is GFCI protected as required.
![]() Exterior Receptacle Polarity/Voltage Test
|
11.13 |
Polarity / Voltage Test - Bedroom Receptacles
Comments: Yes |
11.14 |
Polarity / Voltage Test - Receptacle Behind Refrigerator
Comments: Not Inspected |
![]() |
The receptacle behind the refrigerator was not accessible due to the fixed 12V refrigerator that had no access to the rear of the unit. |
11.15 |
Polarity / Voltage Test - Kitchen Receptacles
Comments: Yes |
The GFCI receptacle is located on the kitchen cabinet next to the front door entrance.
![]() Kitchen Receptacle Voltage
![]() Kitchen Receptacle Frequency
|
11.16 |
Polarity / Voltage Test - Bath and Toilet Area Receptacles
Comments: Yes |
11.17 |
Polarity / Voltage Test - Receptacles Behind all Electronics and Appliances
Comments: Yes |
TV Receptacle Photo
![]() Receptacle Behind the TV
|
11.18 |
Voltage Test - USB Ports / 12-Volt Plugins
Comments: Yes |
USB Port Photos
![]() USB Port on Solar Controller
![]() USB Port in Upper Bunkhouse Area
|
11.19 |
GFCI Trip Testing - Bathroom Receptacles
Comments: Yes |
Bathroom Receptacle Photo
![]() Bathroom Receptacle
|
11.20 |
GFCI Trip Testing - Kitchen Receptacles
Comments: Yes |
11.21 |
GFCI Trip Testing - All Exterior Receptacles
Comments: Yes |
11.22 |
GFCI Trip Testing - All Receptacles Behind Electronics and Appliances
Comments: Yes |
11.23 |
Power Converter - Did DC Voltage Drop at Least 1/2 Volt
Comments: Yes |
11.24 |
Inverter - Installed
Comments: Yes |
The 1,000 Watt inverter is located under the bed on the curbside.
![]() Inverter
|
11.25 |
Inverter - Inspected Cables, Wiring and Fuses
Comments: Yes |
11.26 |
12-Volt DC House Battery(s) - Matched for Size and Age
Comments: Yes |
11.27 |
12-Volt DC House Battery(s) - Positive and Negative Cables Matched for Load
Comments: Yes |
11.28 |
12-Volt DC House Battery(s) - Have They Been Maintained?
Comments: Yes |
Inspector observed two 12 Volt DC batteries were present in the House Battery Box. The battery box and connections were
clean, and all connections were tight. A battery box cover was also present and in acceptable condition.
![]() House Battery Box
![]() House Battery Box with Cover Installed
|
11.29 |
12-Volt DC House Battery(s) - Operational
Comments: Yes |
11.30 |
12 Volt DC House Battery - Water Level in Batteries
Comments: Yes |
NOTE: Due to the types of materials and waste used in the tanks and depending on previous maintenance, fresh and waste monitor sensor probes may perform inaccurately between applications due to build up.
City Water - Food Grade Hose Available for Test:
Yes |
City Water - Pressure Regulator Available:
Yes |
City Water - Connections Operate:
Yes |
City Water - System Holds Pressure:
Yes |
On-Board Water System - Tested Fresh Water Fill:
Yes |
On-Board Water System - Pressure System Works:
Yes |
On-Board Water System - Pump Creates and Holds Pressure:
Yes |
Black Water Tank #1 - Valve Operates:
Yes |
Black Water Tank #1 - Valve Type:
Manual Pull T-Handle |
Black Water Tank #1 - Tank or Valve or Line Leaks:
No |
Black Water Tank #1 - Drain Cap in Place:
Yes |
Black Water Tank #1 - Drain Cap Holds Waste Water Back:
Yes |
Gray Water Tank #1 - Valve Operates:
Yes |
Gray Water Tank #1 - Valve Type:
Manual Pull T-Handle |
Gray Water Tank #1 - Tank or Valve or Line Leaks:
No |
Gray Water Tank - Drain Cap in Place:
Yes |
Gray Water Tank - Drain Cap Holds Gray Water Back:
Yes |
Battery Monitor Reading:
Full |
NOTE: The Following Readings Should be AFTER Emptying Tanks if Possible:
Results of the Test |
Fresh Water Tank Reading:
Empty |
Black Water Tank #1 Reading:
Empty |
Gray Water Tank #1 Reading:
Empty |
12.0 |
Operation and Condition of Outside Shower
Comments: Acceptable |
The outside shower is functional and in acceptable condition.
![]() Outside Shower
|
12.1 |
Onboard Water Filtration System
Comments: Acceptable |
Onboard water filtration system located under the bed behind the water heater.
![]() Water Filtration System
|
12.2 |
City Water Connection Condition
Comments: Acceptable |
The city water connection point is in acceptable condition.
![]() City Water Connection
|
12.3 |
On-Board Water System: Tank, Water Pump and Fixtures for Tank Fill Condition
Comments: Acceptable |
![]() |
(1) Inspector observed the fresh water tank electric heating pad is separating from the underside of the tank. Recommend the pad
be repaired by a qualified RV technician.
![]() |
![]() |
(2) Fresh Water Fill Receptacle Photos
![]() Fresh Water Fill Cap
![]() Fresh Water Fill Receptacle
|
12.4 |
Waste Water Sewer / Hose Fittings
Comments: Acceptable |
The sewer hose dump valves are in acceptable condition and operate smoothly.
![]() Waste Water Sewer Hose Dump Valves
|
12.5 |
Black Water Tank #1
Comments: Acceptable |
12.6 |
Gray Water Tank #1
Comments: Acceptable |
![]() |
Inspector observed the gray water tank electric heating pad is separating from the underside of the tank. Recommend the pad
be repaired by a qualified RV technician.
![]() Gray Tank Heating Pad
|
12.7 |
Battery / Waste / Water Monitor Panel Condition
Comments: Acceptable |
The Battery/Waste/Water monitor panel is located on the side of the kitchen cabinet inside the main entrance.
![]() Battery/Waste/Water Monitor Panel
|
NOTE: CO Detectors have an estimated service life of 5 to 7 years after which time it is recommended they be replaced.
NOTE: Smoke Detectors have an estimated service life of 5 or 10 years after which time it is recommended they be replaced.
DOT Tank Location:
Where is the tank(s) located? DOT Tank Location : On the tongue in front of the battery box. |
DOT - Cylinder Arrangement:
Dual |
DOT #1 - Cylinder Size:
20 LBS |
DOT #1 - Date of Manufacture:
Other Month / Other : 04/21 |
DOT Tank #1 - Rust or Damage Condition:
Acceptable |
DOT #2 - Cylinder Size:
20 LBS |
DOT #2 - Date of Manufacture:
Other Month / Other : 04/21 |
DOT Tank #2 - Rust or Damage Condition:
Acceptable |
DOT - Regulator Type:
Dual Input - Auto Change Over |
DOT - Regulator Vents Downward:
Yes |
DOT - Hoses and Regulators:
Acceptable |
LP Leak / Drop Test:
Pass |
LP Leak / Drop Test - Did Pressure Drop During Leak Test:
No |
LP Leak / Drop Test - Begin Time:
Begin Time Enter Start Time : 3:45 PM |
LP Leak / Drop Test - Completed Time:
Stop Time Enter Stop Time : 3:51 PM |
LP Detector Test Result:
Pass |
LP Detector Model / Serial Number:
Other Other / Model / Serial # : RV Safe LLC / RVCOLP-2 / 1256073 |
LP Detector Date:
One Year Old Date : 06 / 01 / 2021 |
LP Detector Test Method:
Tested by Pushing Button and Spraying LP |
LP Detector Alarm During Test:
Yes |
Carbon Monoxide Detector Test Result:
Pass |
Carbon Monoxide Detector Model / Serial Number:
Other Other / Model / Serial # : RV Safe LLC / RVCOLP-2 / 1256073 |
Carbon Monoxide Detector Date:
One Year Old Date : 06 / 01 / 2021 |
Carbon Monoxide Detector Alarm During Test:
Yes, by Pushing the Button |
Smoke Detector Test Result:
Pass |
Smoke Detector Model / Serial Number:
Other Other / Model / Serial # : Universal |
Smoke Detector Date:
Three Years Old Date : 02 / 28 / 2019 |
Smoke Detector Alarm During Test:
Yes, by Pushing the Button |
Fire Extinguisher - Size:
Travel Trailer or 5th Wheel without Generator 5 B:C Extra Info : 10 B:C |
Fire Extinguisher - Secure in Bracket:
Yes |
Fire Extinguisher - Mounted within 24 Inches of Entrance Door:
Yes |
Fire Extinguisher - Gauge Indicates Charged State:
Yes |
13.0 |
DOT Cylinder(s)
Comments: Acceptable |
DOT cylinder inspection is located on the cylinder handle and within the 10 year tolerance period.
![]() DOT Cylinder Date
|
13.1 |
LP Leak System Test
Comments: Acceptable |
![]() |
Inspector performed an LP Leak Drop Test on the propane system. The system should charge to 11" WC, but this system was
charging to 13" WC.When the system was bled down to 8" WC, no drop was detected after five minutes. Recommend the
propane system be evaluated and repaired by a qualified RV technician to address the overcharging condition.
![]() LP Leak / Drop Test Start Time
![]() LP Leak / Drop Test End Time
|
13.2 |
LP Detector
Comments: Acceptable |
The LP detector is a combination LP/Carbon Monoxide detector unit mounted within six inches of the kitchen floor to the right
of the electrical panel box.
![]() LP/CO Detector Front
![]() LP / CO Detector Rear
|
13.3 |
Carbon Monoxide Detector
Comments: Acceptable |
The Carbon monoxide detector is a combination LP/Carbon Monoxide detector unit mounted within six inches of the kitchen floor to the right of the electrical panel box. |
13.4 |
Smoke Detector
Comments: Acceptable |
The smoke detector is mounted on the streetside ceiling above the master bed.
![]() Smoke Detector Interior
|
13.5 |
Fire Extinguisher
Comments: Acceptable |
The fire extinguisher is of the correct size, charged, and located just inside the main entrance.
![]() Fire Extinguisher Label with Size Displayed
|
Refrigerator Brand:
MAGIC CHEF Model # and Serial # : Model #: WD-127FDC Serial #: ZD2102-0145 |
Refrigerator Cooling Source(s):
12 Volt DC |
Refrigerator: Operates on all Available Sources:
Yes |
Refrigerator Type:
Residential |
Refrigerator - Control Panel Location:
Inside Door |
Refrigerator - Door Latch Secure:
Yes |
Refrigerator - Freezer Current Temperature:
Degrees F Degrees : 4 |
Refrigerator - Odor Detectable in Freezer:
No |
Refrigerator - Current Refrigerator Temperature:
Degrees F Degrees : 48 |
Refrigerator - Has Unit been Running 12 + Hours:
Yes |
Refrigerator - Odor Detectable in Refrigerator:
No |
Refrigerator - Does Inside Light Work:
Yes |
Cooktop - Brand:
Magic Chef |
Cooktop - All Burners Operate:
Yes |
Cooktop - Rubber Grommets for Stovetop Grate:
Yes |
Cooktop - Burner Ignition Source:
Piezo Ignition - Turn Knob to Create a Spark |
Cooktop - All Burners Light:
Yes |
Cooktop - Cover Matches Countertop Material:
Yes |
Oven - Brand:
Magic Chef |
Oven - Burner Ignition Source:
Piezo Ignition - Turn Knob to Create a Spark |
Oven - Burner Lights:
Yes |
Microwave - Brand:
MAGIC CHEF |
Microwave - Type:
Microwave Only |
Microwave - Temperature of Water after 60 Seconds:
Degrees F Degrees : 144 |
Microwave - Rack and Turntables are Installed:
Yes |
Cooktop Exhaust Vent - Part of Microwave:
No |
Cooktop Exhaust Vent - Venting:
Vents to Exterior |
14.0 |
Refrigerator - User Control Panel
Comments: Acceptable |
![]() |
Inspector noted that the refrigerator and freezer had still not cooled down to the recommended temperature ranges for safe food
storage after 24 hours of continuous operation. The outside temperature at the time of testing was 102 Degrees.
![]() Refrigerator Temperature
![]() Freezer Temperature
|
14.1 |
Refrigerator - Front Side Door Panels
Comments: Acceptable |
Refrigerator Front Photo
![]() Refrigerator Front
|
14.2 |
Refrigerator - Front Side Door Seals
Comments: Acceptable |
Refrigerator Door Seal
![]() Refrigerator Door Seal
|
14.3 |
Refrigerator - Front Side Door Frame
Comments: Acceptable |
14.4 |
Refrigerator - Inside Freezer Walls
Comments: Acceptable |
14.5 |
Refrigerator - Freezer Shelves / Door Racks
Comments: Acceptable |
14.6 |
Refrigerator - Inside Walls
Comments: Acceptable |
14.7 |
Refrigerator - Shelves / Door Racks
Comments: Acceptable |
14.8 |
Refrigerator - Crisper Trays and Drawers
Comments: Acceptable |
14.9 |
Cooktop - Condition
Comments: Acceptable |
The glass cooktop cover is crack-and-stain-free.
![]() |
14.10 |
Cooktop - Burner Grate / Cover Condition
Comments: Acceptable |
Burner Grate Photo
![]() Burner Grate
|
14.11 |
Cooktop - Condition of Knobs / Controls
Comments: Acceptable |
Cooktop Knob Photo
![]() Cooktop Knobs
|
14.12 |
Cooktop - Color of Burner Flame
Comments: Acceptable |
The cooktop burner flame is blue with very little yellow flame evident.
![]() Burner Flames
|
14.13 |
Oven - Condition
Comments: Acceptable |
14.14 |
Oven - Racks Condition
Comments: Acceptable |
Inspector observed no damage or staining within the oven.
![]() Oven and Racks
|
14.15 |
Oven - Color of Burner Flame
Comments: Acceptable |
The oven flame is a consistent blue throughout.
![]() Oven Flame
|
14.16 |
Microwave - Condition
Comments: Acceptable |
The microwave is acceptable and warmed a mug of water to 144 degrees in 60 seconds.
![]() Microwave Water Test Result
|
14.17 |
Cooktop Exhaust Vent - Filter and Lighting Condition
Comments: Acceptable |
14.18 |
Cooktop Exhaust Vent - Fan Speeds and Vent Condition
Comments: Acceptable |
Water Heater - Brand:
Suburban |
Water Heater - Type:
Tank Type |
Water Heater - Heat Source(s):
Gas and Electric |
Water Heater - Operates on all Sources:
Yes |
Water Heater - Type of Ignition:
DSI and Electric |
Water Heater - Leaks at Pressure Relief Valve:
No |
Water Heater - Proper Drain Plug Installed:
Yes |
Water Heater - Bypass Valves in Correct Position:
Yes |
Water Heater - Dauber Screens Installed:
Yes |
Furnace - Brand:
Other Model # / Serial # : Airxcel Model #: NT-16SQ Model#: Not visible to inspector |
Furnace - Operates:
Yes |
Furnace - Floor Vents or Outside Exhaust Vents Blocked or Covered:
No |
Furnace - Warm Air Discharge Out of Vents - Proper Return Air Flow:
Yes |
Furnace - Dauber Screens Installed:
Yes |
15.0 |
Water Heater - Condition of Burner Assembly Area
Comments: Acceptable |
Water Heater Photo
![]() Water Heater Burner Assembly Area
|
15.1 |
Water Heater - Rubber Grommet Around Gas Line Sealed
Comments: Poor |
![]() |
Inspector observed no high temperature sealant was applied over gas line rubber grommet. Recommend sealant be applied over
rubber grommet by a qualified RV technician to prevent possible LP leakage into the living space.
![]() Water Heater Grommet Seal
|
15.2 |
Furnace #1 Air Intake / Exhaust Area Condition
Comments: Acceptable |
Air Conditioner - Brand:
Coleman Model # / Serial # / Specify Other : Model #: 47,000 Series Serial #: Not visible to inspector |
Air Conditioner - Options:
AC Only |
Air Conditioner - Delta-T:
Degrees F Degrees : 22 |
16.0 |
Air Conditioner Condition
Comments: Acceptable |
A/C Photos (Outside)
![]() A/C Shroud (Rear)
![]() A/C Shroud (Front)
|
16.1 |
Air Conditioner - Filter Condition
Comments: Acceptable |
16.2 |
Air Conditioner - Exhaust Condition
Comments: Acceptable |
The Delta-T test resulted in a value of 22 degrees.
![]() A/C Intake Temperature
![]() A/C Exhaust Temperature
|
Ceiling - Condition:
Acceptable |
Ceiling Vents and Skylights - Condition:
Acceptable |
Ceiling Vents and Skylights - Trim Ring Around Vents and Skylights:
Acceptable |
Lights and Light Fixtures - Condition:
Acceptable |
Walls - Condition:
Acceptable |
Walls - Interior Doors Condition:
Acceptable |
Closets and Pantries - Condition:
Acceptable |
Windows - Condition:
Acceptable |
Flooring - Condition:
Acceptable |
Kitchen Sink - Condition:
Acceptable |
Kitchen Sink - Style:
Single Bowl |
Kitchen Sink - Type:
Stainless |
Shower / Tub - Condition:
Acceptable |
Shower / Tub - Style:
Shower Tub Combo |
Bathroom Sink - Condition:
Acceptable |
Bathroom Sink - Style:
Single Bowl |
Bathroom Sink - Type:
Plastic |
17.0 |
Ceiling Inspected
Comments: Yes |
17.1 |
Ceiling - Panels Loose
Comments: No |
17.2 |
Ceiling - Water Damaged Ceiling Panels
Comments: No |
17.3 |
Ceiling - Discoloration or Stains
Comments: No |
17.4 |
Ceiling - Trim Work Missing or Damaged
Comments: No |
17.5 |
Ceiling Vents and Skylights - Thermostatic Controls and Switches Work
Comments: Yes |
17.6 |
Ceiling Vents - All 12-Volt DC Fans Operate
Comments: Yes |
17.7 |
Ceiling Vents and Skylights - Stains Around Roof Vents and Skylights
Comments: No |
17.8 |
Lights and Light Fixtures - Do all 12-Volt DC Lights Function
Comments: Yes |
17.9 |
Lights and Light Fixtures - Entry Lights inside RV
Comments: Yes |
17.10 |
Lights and Light Fixtures - Missing or Broken Lenses
Comments: No |
17.11 |
Lights and Light Fixtures - Missing Shades or Broken Covers
Comments: No |
17.12 |
Walls Inspected
Comments: Yes |
17.13 |
Walls - Panels Loose
Comments: No |
17.14 |
Walls - Water Damaged Wall Panels
Comments: No |
17.15 |
Walls - Panels Discolored or Stained
Comments: No |
17.16 |
Walls - Soft Spots on Walls
Comments: No |
17.17 |
Walls - Trim Work on Walls
Comments: Yes |
17.18 |
Walls - Damage Repairs Performed
Comments: No |
17.19 |
Walls - Holes or Wall Repairs
Comments: No |
17.20 |
Closets / Pantries Inspected
Comments: Yes |
17.21 |
Closets and Pantries - Door Damage / Scratches
Comments: No |
17.22 |
Closets and Pantries - Wood Rot or Broken
Comments: No |
17.23 |
Windows - All Windows Operational
Comments: Yes |
17.24 |
Windows - Window Coverings
Comments: Yes |
![]() |
Valance over large dinette window is no longer held in place by its mounting screws. The valance was located on the dinette
table at the time of the inspection and is in acceptable condition to be re-mounted.
![]() Large Dining Area Window
![]() Left End of Valance Mounting Above Dinette Window
|
17.25 |
Windows - Emergency Exit Windows Installed
Comments: Yes |
17.26 |
Windows - Emergency Exit Windows Operational
Comments: Yes |
17.27 |
Flooring - Sheet Vinyl
Comments: Yes |
17.28 |
Flooring - Carpet
Comments: Yes |
17.29 |
Flooring - Floor Panels Loose
Comments: No |
17.30 |
Flooring - Floor Covering Discolored or Stained
Comments: No |
17.31 |
Flooring - Water Damage
Comments: No |
17.32 |
Flooring - Carpet Worn
Comments: No |
17.33 |
Flooring - Sheet Vinyl Stained
Comments: No |
17.34 |
Flooring - Soft Spots in Floor
Comments: No |
17.35 |
Flooring - Previous Repairs Performed
Comments: No |
17.36 |
Operation and Condition of Kitchen Faucet
Comments: Yes |
17.37 |
Kitchen Sink - Faucet Working
Comments: Yes |
17.38 |
Kitchen Sink - Faucet Leaks at Stem
Comments: No |
17.39 |
Kitchen Sink - Water Damage Under Sink
Comments: No |
17.40 |
Kitchen Sink - P-Trap Holds Water
Comments: Yes |
17.41 |
Kitchen Sink - Sink(s) Holds Water
Comments: Yes |
17.42 |
Kitchen Sink - Hot and Cold Water Available
Comments: Yes |
17.43 |
Operation and Condition of Toilet
Comments: Yes |
17.44 |
Toilet - Water Leaks
Comments: No |
17.45 |
Toilet - Indication of Previous Damage or Repair
Comments: No |
17.46 |
Toilet - Bowl Holds Water
Comments: Yes |
17.47 |
Toilet - Mounting Problems
Comments: No |
17.48 |
Operation and Condition of Shower
Comments: Yes |
17.49 |
Shower / Tub - Stains, Chemical Buildup in Stall / Tub
Comments: No |
17.50 |
Shower / Tub - Water Damage or Leaks
Comments: No |
17.51 |
Shower / Tub - Soap Dish in Place
Comments: Yes |
17.52 |
Shower / Tub - Curtain with Rod
Comments: Yes |
17.53 |
Operation and Condition of Bathroom Faucet
Comments: Yes |
17.54 |
Bathroom Sink - Faucet Working
Comments: Yes |
17.55 |
Bathroom Sink - Faucet Leaks at Stem
Comments: No |
17.56 |
Bathroom Sink - P-Trap Holds Water
Comments: Yes |
17.57 |
Bathroom Sink - Sink(s) Holds Water
Comments: Yes |
17.58 |
Bathroom Sink - Hot and Cold Water Available
Comments: Yes |
Dinette / Table / Chairs - Condition:
Acceptable |
Beds - Condition:
Acceptable |
Cabinets / Dressers - Condition:
Acceptable |
Cabinets / Dressers - Types of Hinges:
Exposed / Hidden |
Cabinets / Closet Hardware - Condition:
Acceptable |
18.0 |
Dinette / Table / Chairs Inspected
Comments: Yes |
Dinette Photos
![]() Dinette (Normal Configuration)
![]() Dinette (Bed Configuration)
|
18.1 |
Dinette / Table / Chairs - Fabric Tears or Separation
Comments: No |
18.2 |
Dinette / Table / Chairs - Fabric Discolored or Stains
Comments: No |
18.3 |
Dinette / Table / Chairs - Signs of Excess Wear
Comments: No |
18.4 |
Dinette / Table / Chairs - Water Damage
Comments: No |
18.5 |
Dinette / Table / Chairs - Previous Repairs Performed
Comments: No |
18.6 |
Beds Inspected
Comments: Yes |
18.7 |
Beds - Fabric Tears or Separation
Comments: No |
18.8 |
Beds - Fabric Discolored or Stains
Comments: No |
18.9 |
Beds - Signs of Excess Wear
Comments: No |
18.10 |
Beds - Pillow Top Mattress
Comments: No |
18.11 |
Beds - Bed Covers
Comments: Yes |
18.12 |
Beds - Covers Match Decor
Comments: Yes |
18.13 |
Cabinets / Dressers Inspected
Comments: Yes |
18.14 |
Cabinets / Dressers - Door Damage or Scratches
Comments: No |
18.15 |
Cabinets / Dressers - Counter Top Damage or Scratches
Comments: No |
18.16 |
Cabinets / Dressers - Wood Rot or Broken
Comments: No |
18.17 |
Cabinets / Dressers - Drawer Damage or Scratches
Comments: No |
18.18 |
Cabinet Doors / Drawers - Pull-Out Operation Acceptable
Comments: Yes |
18.19 |
Cabinet Doors / Drawers - Previous Repairs Performed
Comments: No |
Unit Brand:
Other Model # / Other Specify : Furrion Model #: FDFD22A0A |
Antenna Power Booster Operates:
Yes |
TV Picks Up Local Channels:
Yes |
Remotes Operational:
Yes |
19.0.A |
Unit Works Properly
Comments: Yes |
Inspector found the TV and DVD player are in Acceptable condition.
![]() TV
|
19.1.A |
Unit Cleaned and Maintained
Comments: Yes |
19.2.A |
Unit Properly Mounted and Secured
Comments: Yes |
Unit Brand:
Other Model # / Other Specify : DVD player is incorporated into TV |
19.0.B |
Unit Works Properly
Comments: Yes |
The DVD player is integrated into the TV, and discs are inserted on the right end of the unit.
![]() The TV operating in DVD mode.
![]() DVD Player
|
19.1.B |
Unit Cleaned and Maintained
Comments: Yes |
Unit Brand:
Other Model # / Other Specify : iRV Model #: IRV36 |
Antenna Power Booster Operates:
Yes |
TV Picks Up Local Channels:
Yes |
Remotes Operational:
Yes |
19.0.C |
Unit Works Properly
Comments: Yes |
The iRV radio controls are mounted in the cabinet above the TV, and allow the radio and TV to be heard through its speakers
both inside and outside the RV. The outside speaker is mounted to the left of the front door.
![]() iRV RADIO
![]() Outside Speaker
![]() Outside speaker
|
19.1.C |
Unit Cleaned and Maintained
Comments: Yes |
19.2.C |
Unit Properly Mounted and Secured
Comments: Yes |