RV Inspection Report

Prepared for: RV Inspection Sample Report (Towable)

RV Location:
2222 Even Happier St, Middle Of, KS

 

Inspection Date / RV Model:
07/28/2022 2021 Fleetwood E-Pro E20BHS

VIN Number: 0ZT0FSJC0M0000000


Extra Mile Mobile RV Services, LLC

Kevin Gleason
11232 Delaware Pkwy
Kansas City, KS 66109
913-557-0033

 

Top Table of Contents Bottom
Top Table of Contents Bottom

LIFE SAFETY ISSUE


Extra Mile Mobile RV Services, LLC

Customer
RV Inspection Sample Report (Towable)
Inspection Date / Year,Make,Model:
07/28/2022 2021 Fleetwood E-Pro E20BHS
VIN Number:
0ZT0FSJC0M0000000

The following items indicate that the condition is a LIFE SAFETY ISSUE. It is recommended that a qualified RV technician correct the identified issue, and before the unit is occupied.

6.  Slideouts
6.1  Slideout T-Molding Trim  
Poor
Inspector observed a bare wire protruding from the top rear corner of the slideout T-molding. Recommend repair by a qualified RV technician.

7(A) .  Curbside - Front Wheel Assembly
7.0.A  Tire Condition  
Fair
Tire pressure was observed to be 43 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to movement of the RV.

7(B) .  Spare Tire Assembly
7.0.B  Tire Condition  
Fair
Tire was found to be inflated to 44.5 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to first movement in case the tire is needed.

7(C) .  Streetside - Front Wheel Assembly
7.0.C  Tire Condition  
Fair
Tire was found to be inflated to 42.7 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to first movement.

15.  Appliances: Other
15.1  Water Heater - Rubber Grommet Around Gas Line Sealed  
Poor
Inspector observed no high temperature sealant was applied over gas line rubber grommet. Recommend sealant be applied over rubber grommet by a qualified RV technician to prevent possible LP leakage into the living space.


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Kevin Gleason
Top Table of Contents Bottom

MAJOR ISSUE


Extra Mile Mobile RV Services, LLC

Customer
RV Inspection Sample Report (Towable)
Inspection Date / Year,Make,Model:
07/28/2022 2021 Fleetwood E-Pro E20BHS
VIN Number:
0ZT0FSJC0M0000000

The following items indicate that the condition is a MAJOR ISSUE.  It is recommended that a qualified RV technician correct the identified issue as needed.

2.  Roof Exterior
2.1  Front Cap, Joints and Seals  
Poor
Inspector observed significant seal cracks on the curbside half of the front cap seal. Recommend these areas be repaired by a qualified RV technician.
2.6  Exterior Vent Covers  
Poor
MaxxAir vent cover sealant has multiple cracks and points of sealant damage. Recommend these areas be repaired by a qualified RV technician to prevent water intrusion.
2.7  Plumbing Vent Covers  
Poor
Both plumbing vent covers have sealant that is cracked and separating from the base of the covers. Recommend these areas be repaired by a qualified RV technician.
2.8  Skylights  
Poor
Shower skylight cover sealant cracked at multiple points along streetside and rear edges. Recommend these areas be repaired by a qualified RV technician to prevent water intrusion.
2.12  Solar Panels  
Poor
(1) Solar panel mounting bracket sealant shows signs of cracking. Recommend these areas be repaired by a qualified RV technician.
(2) Solar panel cable connection bracket sealant has a crack and hole. Recommend these areas be repaired by a qualified RV technician.
2.13  Ladder - Roof Access  
Poor
Right ladder handle sealant has a hole on rear cap side. Recommend this area be repaired by a qualified RV technician.


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Kevin Gleason
Top Table of Contents Bottom

MINOR ISSUE


Extra Mile Mobile RV Services, LLC

Customer
RV Inspection Sample Report (Towable)
Inspection Date / Year,Make,Model:
07/28/2022 2021 Fleetwood E-Pro E20BHS
VIN Number:
0ZT0FSJC0M0000000

The following items indicate that the condition is a MINOR ISSUE.  It is recommended that a qualified RV technician correct the identified issue as needed.

2.  Roof Exterior
2.3  Rear Cap, Joints and Seals  
Fair
Rear cap seal has multiple bubble holes and signs of scuffing near the ladder. Recommend these areas be repaired by a qualified RV technician.

3(B) .  Curbside - Sidewall
3.0.B  Sidewall Condition  
Fair
(2) Inspector observed that the curbside wheel well cover was cracked behind the third and fourth screws as counted from the front. Recommend repair by a qualified RV technician.
3.3.B  Cargo/Access Doors  
Fair
Curbside cargo access door frame slightly bent. Door operation is not affected.

4(A) .  Main Entry Door
4.0.A  Door Condition  
Fair
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV technician.

13.  Propane Tank, Lines and Connections
13.1  LP Leak System Test  
Acceptable
Inspector performed an LP Leak Drop Test on the propane system. The system should charge to 11" WC, but this system was charging to 13" WC.When the system was bled down to 8" WC, no drop was detected after five minutes. Recommend the propane system be evaluated and repaired by a qualified RV technician to address the overcharging condition.

17.  Interior
17.24  Windows - Window Coverings  
Yes
Valance over large dinette window is no longer held in place by its mounting screws. The valance was located on the dinette table at the time of the inspection and is in acceptable condition to be re-mounted.


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Kevin Gleason
Top Table of Contents Bottom

NOTICE / COMMENT


Extra Mile Mobile RV Services, LLC

Customer
RV Inspection Sample Report (Towable)
Inspection Date / Year,Make,Model:
07/28/2022 2021 Fleetwood E-Pro E20BHS
VIN Number:
0ZT0FSJC0M0000000

The following items indicate that the condition is a NOTEWORTHY COMMENT.

3(B) .  Curbside - Sidewall
3.3.B  Cargo/Access Doors  
Fair
Curbside cargo access door frame slightly bent. Door operation is not affected.

4(A) .  Main Entry Door
4.0.A  Door Condition  
Fair
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV technician.

5.  Awnings
5.1  Fabric Condition  
Acceptable
(1) Inspector observed multiple areas of slight discoloration on top of awning.
(2) Inspector observed multiple areas of slight discoloration on bottom of awning.

11.  Electrical System 120-Volt AC and 12-Volt DC
11.14  Polarity / Voltage Test - Receptacle Behind Refrigerator  
Not Inspected
The receptacle behind the refrigerator was not accessible due to the fixed 12V refrigerator that had no access to the rear of the unit.

12.  Water Systems
12.3  On-Board Water System: Tank, Water Pump and Fixtures for Tank Fill Condition  
Acceptable
(1) Inspector observed the fresh water tank electric heating pad is separating from the underside of the tank. Recommend the pad be repaired by a qualified RV technician.
(2) Fresh Water Fill Receptacle Photos
12.6  Gray Water Tank #1  
Acceptable
Inspector observed the gray water tank electric heating pad is separating from the underside of the tank. Recommend the pad be repaired by a qualified RV technician.

14.  Appliances: Kitchen
14.0  Refrigerator - User Control Panel  
Acceptable
Inspector noted that the refrigerator and freezer had still not cooled down to the recommended temperature ranges for safe food storage after 24 hours of continuous operation. The outside temperature at the time of testing was 102 Degrees.


Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Kevin Gleason
Top Table of Contents Bottom

Click on link(s) below for Report Attachments:

2021 Flagstaff E-Pro Brochure

ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.

Top Table of Contents Bottom
Inspection Date / Year,Make,Model : 07/28/2022 2021 Fleetwood E-Pro E20BHS Time: 06:30 AM VIN Number: 0ZT0FSJC0M0000000
RV Location:
2222 Even Happier St, Middle Of, KS
Customer:
RV Inspection Sample Report (Towable)

This time sensitive document was prepared for the client listed on the Cover Page of this report. Any reproduction, use, or resale of this document by individuals other than who is listed on the report cover page, or their assigns, is not supported by the inspector and company.

Comment Key or Definitions

The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this RV home. Any recommendations by the inspector to repair suggests a second opinion or further inspection by a qualified RV technician. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase.

Acceptable  (A) = A visually observed item, component or unit and if no other comments were made then it appeared to be performing its intended function with little or no deterioration visible.

Fair (F)= The item or its components is not in need of immediate repair as it is performing its intended function but deterioration is visible. Some opinions may elect to repair or replace this item now while others may wait.

Poor (P) = The item, component or unit is not functioning as intended and replacement is recommended, or needs further evaluation by a qualified RV technician.

Not Inspected (NI)= The item, unit or component was not inspected, and no representations were made as to whether or not it was functioning as intended and a statement for the reason for not inspecting may be made.

Not Present (NP) = This item, component or unit is not in this RV.


NRVIA Standards of Practice

Purpose, Scope and General Statements

1 – The purpose of the Standards of Practice is to establish a uniform standard for the companies RV Inspector to inspect and report in an objective manner the conditions of a Recreational Vehicle and its components.

2 – The Standards describe the components, and systems included in an RV Inspection.

3 – The Standards apply to motorized and towable types of RVs as defined by the RV Industry.

4 – The Standards apply to a visual inspection of those areas, components and systems that are readily accessible to determine at the time of inspection that they are performing their intended function without regard to life expectancy.

5 – The purpose of the RV inspection is to identify visible and operational defects as permitted by the current conditions that in the judgment of the RV Inspector will adversely affect the function or integrity of the items, components and systems of the Recreational Vehicle.

6 – RV Inspections performed under the Standards of Practice are basically visual and rely upon the opinion, judgment, education and experience of the RV Inspector and are not intended to be technically exhaustive.

7 – RV Inspections shall be performed in a time period sufficient to allow compliance with the provisions of the NRVIA Standards of Practice.

8 – RV Inspections performed under the Standards shall not be construed as being a compliance inspection of any code, governmental regulation or manufacturer’s installation instructions or procedures. In the event a law, statute or ordinance prohibits a procedure recommended in the Standards, the RV Inspector is relieved of the obligation to adhere to the prohibited part of the Standards.

9 – RV Inspections performed under the Standards are not an expressed, implied warranty or guarantee of adequacy, performance or useful life of any RV, any of its components or systems.

10 – Only those items specifically listed on the RV Inspection Report will be included in the RV Inspectors evaluation.

11 – The RV Inspector shall report any system or component included in the Standards of Practice which were present at the time of the RV Inspection but were NOT inspected and provide the reason they were not inspected.


General Limitations and Exclusions

1 – RV Inspections performed under the companies Standards of Practice exclude any items concealed or not readily accessible to the RV Inspector. The RV Inspector is not required to move furniture, personal or stored items. Lifting floor covering, accessing interior walls and ceilings in which could damage or destroy the components or systems being evaluated is not part of the RV Inspection.

2 – The determination of the presence of damage caused by insects or water is only to be evaluated by observation with an opinion being rendered by RV Inspector that is to make the client aware of the issue.

3 – Excluded from the Standards of Practice is the determination of indoor air quality of the RV and it’s consequence of physical damage, toxicity, odors, waste products and noxiousness.

4 – The RV Inspection and report are opinions only that are based upon the visual observation of the existing conditions of the RV at the time of the RV Inspection. The report is not intended to be or construed as a guarantee, warranty or any form of insurance. The RV Inspector will not be responsible for any repairs or replacement with regard to the RV or its contents.

5 – The RV Inspector is not required to enter any premises that visibly show a threat to the safety of the RV Inspector or others nor inspect any area or component that poses a danger to the RV Inspector or others.

6 – The NRVIA Certified RV Inspector will inspect and report on the RV items listed in this report and their condition during the RV Inspection. Any additional items of inspection will be dependent upon any agreements that are made between the client and the RV Inspector.

Weather:
Partly Cloudy

Type of Inspection:
Seller: RV Inspection for Potential Buyer

Style of RV:
Travel Trailer

RV Status:
Occupied at the Time of the Inspection

Client Is Present:
Yes

Start Temperature:
75 degrees

Top Table of Contents Bottom
1.  Vehicle Information
Styles & Materials
VIN Number:
Photo Included
VIN #: : 0ZT0FSJC0M0000000
VIN Location:
Streetside Front
RVIA / Canadian Seal Number:
Located by Entrance Door
Seal Number / Other Info : SA000000
Gross Vehicle Weight Rating (GVWR):
From Data Plate
Specify in lbs or kg : 4,355 lbs
Brand of RV:
Manufacturer's Brand Name
Brand Name : E-Pro by Flagstaff
Model Number:
RV Designation/Floorplan
Model Number : E20BHS
Manufacturer Name and Location:
Forest River
Location: City, State : Millersburg, IN
Date of Manufacturer:
July
Year : 2021
State Inspection Sticker Current:
Not Required
State License Plate Current:
Yes
State and Plate Number : Kansas - 000AAA
   
Items
1.0 Vehicle Data
(1) Manufacturer's VIN Data Plate Photo
VIN Data Plate
(2) RVIA Seal Photo
RVIA Seal
(3) State License Plate Photo
Kansas License Plate
(4) Owner Stated Comments:

1. Owner stated that he has two mattresses and a ladder for the bunkhouse. All three are like new and never used.  

2. Owner stated that he never had a keyless door lock code for the front entrance door, nor was a code sticker located inside the lock as listed on the manufacturers website. The issue was not resolved during a phone call with manufacturer customer support. The door lock and deadbolt work as intended with a key.

(5) Weather the Day of the Inspection: Weather on the day of the inspection was partly cloudy with temperatures starting in the low 80's and rising to mid 90's.
Top Table of Contents Bottom
2.  Roof Exterior
Styles & Materials
Roof Type:
Rubber (TPO)
Areas of Possible Water Intrusion:
Yes
Roof Ladder Type:
Mounted
Number of Solar Panels:
One
TV Antenna - Cleaned and Maintained:
Yes
Equipment Removed:
No
Items
2.0 Roof Condition
Comments: Acceptable
Roof Overview Photos
Roof Overview - Front to Back
Roof Overview - Back to Front
2.1 Front Cap, Joints and Seals
Comments: Poor
Inspector observed significant seal cracks on the curbside half of the front cap seal. Recommend these areas be repaired by a qualified RV technician.
Front Cap Seal Looking from Front Curbside Joint
Front Cap Seal Near Curbside Joint
2.2 Trim Rail (Curbside)
Comments: Acceptable
2.3 Rear Cap, Joints and Seals
Comments: Fair
Rear cap seal has multiple bubble holes and signs of scuffing near the ladder. Recommend these areas be repaired by a qualified RV technician.
Rear Cap Seal Right of the Ladder
Rear Cap Seal Between Ladder Handles
2.4 Trim Rail (Streetside)
Comments: Acceptable
2.5 Vents - Manual Crank (14 x 14)
Comments: Acceptable
2.6 Exterior Vent Covers
Comments: Poor
MaxxAir vent cover sealant has multiple cracks and points of sealant damage. Recommend these areas be repaired by a qualified RV technician to prevent water intrusion.
MaxxAir Vent Cover Sealant with Exterior Cover Removed
MaxxAir Cover Sealant With Cover in Place
2.7 Plumbing Vent Covers
Comments: Poor
Both plumbing vent covers have sealant that is cracked and separating from the base of the covers. Recommend these areas be repaired by a qualified RV technician.
Rear Plumbing Vent Cover
Front Plumbing Vent Cover
2.8 Skylights
Comments: Poor
Shower skylight cover sealant cracked at multiple points along streetside and rear edges. Recommend these areas be repaired by a qualified RV technician to prevent water intrusion.
Skylight Cover
2.9 Air Conditioner #1 (Shroud)
Comments: Acceptable
2.10 Air Conditioner #1 (Exterior Coils)
Comments: Acceptable
2.11 TV Antenna Exterior Roof Unit
Comments: Acceptable
2.12 Solar Panels
Comments: Poor
(1) Solar panel mounting bracket sealant shows signs of cracking. Recommend these areas be repaired by a qualified RV technician.
(2) Solar panel cable connection bracket sealant has a crack and hole. Recommend these areas be repaired by a qualified RV technician.
Solar Panel Cable Connection Bracket
2.13 Ladder - Roof Access
Comments: Poor
Right ladder handle sealant has a hole on rear cap side. Recommend this area be repaired by a qualified RV technician.
Ladder Handle Mounts on Roof
Top Table of Contents Bottom
3(A) .  Front Cap / Wall
Styles & Materials
Exterior Wall Surface Type:
Molded Fiberglass Cap
Fiberglass with Decals
Any Damage or Discoloration or Delamination?:
No
Windows:
Glass with No Frame
Cargo Doors:
None
   
Items
3.0.A Sidewall Condition
Comments: Acceptable
Front Cap Wall Photo
Front Cap Wall
3.1.A Paint and/or Decals
Comments: Acceptable
3.2.A Windows
Comments: Acceptable
Top Table of Contents Bottom
3(B) .  Curbside - Sidewall
Styles & Materials
Exterior Wall Surface Type:
Fiberglass with Decals
Any Damage or Discoloration or Delamination?:
No
Windows:
Glass with No Frame
Cargo Doors:
Doors with Keyed Twist Latch
   
Items
3.0.B Sidewall Condition
Comments: Fair
(1) Curbside Sidewall Photo
Curbside Sidewall
(2) Inspector observed that the curbside wheel well cover was cracked behind the third and fourth screws as counted from the front. Recommend repair by a qualified RV technician.
Curbside Wheel Well
Curbside Wheel Well
3.1.B Paint and/or Decals
Comments: Acceptable
3.2.B Windows
Comments: Acceptable
3.3.B Cargo/Access Doors
Comments: Fair
Curbside cargo access door frame slightly bent. Door operation is not affected.
Curbside Cargo Access Door
Top Table of Contents Bottom
3(C) .  Streetside Sidewall
Styles & Materials
Exterior Wall Surface Type:
Fiberglass with Decals
Any Damage or Discoloration or Delamination?:
No
Windows:
Glass with No Frame
Cargo Doors:
Doors with Keyed Lock
Doors with Keyed Twist Latch
   
Items
3.0.C Sidewall Condition
Comments: Acceptable
Streetside Sidewall Photos
Streetside Sidewall (Front)
Streetside Sidewall (Rear)
3.1.C Paint and/or Decals
Comments: Acceptable
3.2.C Windows
Comments: Acceptable
3.3.C Cargo/Access Doors
Comments: Acceptable
Top Table of Contents Bottom
3(D) .  Rear Cap / Wall
Styles & Materials
Exterior Wall Surface Type:
Fiberglass with Decals
Any Damage or Discoloration or Delamination?:
No
Windows:
None
Cargo Doors:
None
   
Items
3.0.D Sidewall Condition
Comments: Acceptable
Rear Cap/Wall Photo
Rear Cap/Wall
3.1.D Paint and/or Decals
Comments: Acceptable
Top Table of Contents Bottom
4(A) .  Main Entry Door
Styles & Materials
Type of Entrance Door:
Fiberglass
Keyless Entry Door Lock System:
Yes
Keyless Entry Door Lock Functional:
No
Keyed Door Lock / Deadbolt Functional:
Yes
Type of Step System:
Manual
Number of Steps:
Two
Grab Bar Type:
D-Ring Handle
   
Items
4.0.A Door Condition
Comments: Fair
Inspector observed that the front entry door is difficult to open from outside. Recommend the door be repaired by a qualified RV technician.
Front Entry Door Handle
Top Table of Contents Bottom
4(B) .  Bunkhouse Door
Styles & Materials
Type of Entrance Door:
Fiberglass
Keyed Door Lock / Deadbolt:
Yes
Keyed Door Lock / Deadbolt Functional:
Yes
Items
4.0.B Door Condition
Comments: Acceptable
Top Table of Contents Bottom
5.  Awnings
Styles & Materials
Awning Material:
Vinyl
Operational Type:
Electric
 
Items
5.0 Frame and Latching Mechanism
Comments: Acceptable
5.1 Fabric Condition
Comments: Acceptable
(1) Inspector observed multiple areas of slight discoloration on top of awning.
Top of Awning
(2) Inspector observed multiple areas of slight discoloration on bottom of awning.
Awning Bottom
Awning Botom
5.2 Awning Operation
Comments: Acceptable
Top Table of Contents Bottom
6.  Slideouts
Styles & Materials
Slideout Roof Type:
(TPO) Rubber
Slideout Drive System:
Lippert Schwinteck w/In-wall Electric Motor
 
Items
6.0 Slideout Roof
Comments: Acceptable
Slideout Roof was found to be in acceptable condition.
Slideout Roof
6.1 Slideout T-Molding Trim
Comments: Poor
Inspector observed a bare wire protruding from the top rear corner of the slideout T-molding. Recommend repair by a qualified RV technician.
Top Rear Corner of Slideout
6.2 Seals, Sweeps and Gaskets
Comments: Acceptable
Slideout Seals, Sweeps, and Gasket Photos
Slideout Top
Slideout Top Front Corner
Slideout Top Rear Corner
Top Rear Seals and Sweeps
6.3 Slide Rail Gear Rack System
Comments: Acceptable
Schwinteck Rail Photos
Bottom Rear Schwinteck Rail
Bottom Rear Slide Rail
6.4 Wiring Harness under Slideout
Comments: Acceptable
6.5 12-Volt DC Control and Switches
Comments: Acceptable
6.6 Slideout Operation and Alignment
Comments: Acceptable
Slide Photos
Slide Extended (Rear)
Slide Extended (Front)
Slide Retraction Video
Top Table of Contents Bottom
7(A) .  Curbside - Front Wheel Assembly
NOTE: The National Transportation Safety Board (NTSB) and some tire manufacturers are recommending that all tires older than six years should be replaced, regardless of their condition.
Styles & Materials
Tire Brand:
Westlake
Tire Size:
Other
Other Size : 235/75R15
DOT Date:
Visually Verified
Enter wwyy : 1521
Load Capacity:
Single Tire Rating
Enter lbs or kg Weight Rating : 2,340 lbs
Load Range:
Other
Extra Info : C
RV Manufacturer's Recommended Inflation Air Pressure:
Other
PSI : 50
Current Air Pressure in Tire:
Tire Gauge Reading (psi)
PSI : 43
Valve Extensions Installed?:
No
Tire Pressure Monitors Installed?:
Yes
Items
7.0.A Tire Condition
Comments: Fair
Tire pressure was observed to be 43 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to movement of the RV.
Curbside Tire Pressure Measurement
7.1.A Tire Tread Condition
Comments: Acceptable
The curbside tire condition was found to be acceptable.
Curbside Tire
Top Table of Contents Bottom
7(B) .  Spare Tire Assembly
NOTE: The National Transportation Safety Board (NTSB) and some tire manufacturers are recommending that all tires older than six years should be replaced, regardless of their condition.
Styles & Materials
Tire Brand:
Westlake
Tire Size:
Other
Other Size : 235/75R15
DOT Date:
Visually Verified
Enter wwyy : 4620
Load Capacity:
Single Tire Rating
Enter lbs or kg Weight Rating : 2340 PSI
Load Range:
Other
Extra Info : C
RV Manufacturer's Recommended Inflation Air Pressure:
Other
PSI : 50
Current Air Pressure in Tire:
Tire Gauge Reading (psi)
PSI : 44.5
Valve Extensions Installed?:
No
Tire Pressure Monitors Installed?:
No
Items
7.0.B Tire Condition
Comments: Fair
Tire was found to be inflated to 44.5 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to first movement in case the tire is needed.
Spare Tire Pressure Measurement
Spare Tire
7.1.B Tire Tread Condition
Comments: Acceptable
Top Table of Contents Bottom
7(C) .  Streetside - Front Wheel Assembly
NOTE: The National Transportation Safety Board (NTSB) and some tire manufacturers are recommending that all tires older than six years should be replaced, regardless of their condition.
Styles & Materials
Tire Brand:
Westlake
Tire Size:
Other
Other Size : 235/75R15
DOT Date:
Visually Verified
Enter wwyy : 1521
Load Capacity:
Single Tire Rating
Enter lbs or kg Weight Rating : 2340 lbs
Load Range:
Other
Extra Info : C
RV Manufacturer's Recommended Inflation Air Pressure:
Other
PSI : 50
Current Air Pressure in Tire:
Tire Gauge Reading (psi)
PSI : 42.7
Valve Extensions Installed?:
No
Tire Pressure Monitors Installed?:
Yes
Items
7.0.C Tire Condition
Comments: Fair
Tire was found to be inflated to 42.7 PSI. Recommend tire be inflated to meet manufacturer's recommended cold tire pressure of 50 PSI per the data plate located on the streetside front sidewall prior to first movement.
Streetside Tire Pressure Measurement
7.1.C Tire Tread Condition
Comments: Acceptable
The streetside tire tread was found to be acceptable.
Streetside Tire
Top Table of Contents Bottom
8.  Running Gear
The inspector will evaluate for signs of rust but will not make a determination of the severity of the rust.  Pictures may be included to show what the inspector observed at the time of the inspection.

Note: Due to insurance restrictions, the RV can NOT be driven by the inspector. Also, due to the lack of clearance under the trailer and safety concerns, the inspector will conduct the following visual inspections from the outer perimeter of the towable RV.

Styles & Materials
Axle Type:
Torsion Axle
Number of Axles:
One
Front Axle Weight Rating:
Listed in lbs or kg
Weight Rating : 3,900 lbs
Axle - Did Inspector Check for Visible Signs of Rust?:
Yes
Was rust present (Yes or No)? : Yes
Axle - Did Inspector Check for Visible Signs of Bent or Damaged Components?:
Yes
Was damage present? : No
Axle - Did Inspector Check for Visible Signs of Oil Stains?:
Yes
Was any present? : No
Brake Type:
Electric
Suspension Bolts with or without Zerk Fittings Have been Evaluated:
Yes
Frame - Did Inspector Check for Visible Signs of Rust?:
Yes
Was any present? : Yes
Frame - Did Inspector Check for Visible Signs of Bent or Damaged Components?:
Yes
Was any present? : No
Frame - Did Inspector Check for any Visible Signs of Oil Stains?:
Yes
Was any present? : No
 
Items
8.0 Running Gear - Condition
Comments: Acceptable
Running Gear Photos
Curbside Running Gear
Streetside Running Gear
8.1 Frame - Condition
Comments: Acceptable
Frame Photos
Frame from Front to Rear
Frame from Rear to Front
Rear Undercarriage 360 Photo
Center Undercarriage 360 Photo
Front Undercarriage 360 Photo
Top Table of Contents Bottom
9.  Hitch and Stabilizing System
Styles & Materials
Travel Trailer - Tongue Jack:
Electric
Travel Trailer - Coupler Operational:
Yes
Travel Trailer - Safety Chains:
Yes
Travel Trailer - Stabilizer:
Manual
Travel Trailer - Weight Distribution System:
Yes
Travel Trailer - Sway Control System:
Yes
Inspect for Visible Signs of Damage:
Yes
Ensure Jacks Extend and Retract Fully:
Yes
Inspect for Leaks or Mechanical Issues:
Yes
Items
9.0 Travel Trailer Tongue Jack Condition
Comments: Acceptable
The trailer tongue jack and front stabilizers were found to be in acceptable condition.
Trailer Tongue Jack and Front Stabilizer Jacks
Rear Stabilizing Jacks
Top Table of Contents Bottom
10.  12-Volt DC Chassis Lights
NOTE: The inspector has verified all the items in this section are functional.

The inspector tested the Break Away switch by pulling the break away cable and listened for a click or hum at the wheel assemblies, and also checked DC amperage at the Break Away switch.  However, this does not indicate that the brakes engaged at all wheel assemblies.  It is recommended that the trailer be attached to a tow vehicle and with the Break Away switch engaged, test resistance to movement.  The best way to be sure this system is functioning is to have the wheels pulled and the brakes be evaluated by a qualified RV technician.

Items
10.0 7-Pin Cord
Comments: Yes
Seven Pin Cord Photo
Seven Pin Cord Connector
10.1 Break Away Switch
Comments: Yes
The break away switch was tested and found to be acceptable.
Breakaway Switch Test
10.2 Front Clearance Lights
Comments: Yes
Clearance Light Photos
Front Curbside Clearance Light
Front Streetside Clearance Light
10.3 Rear Clearance Lights
Comments: Yes
Rear Clearance Light Photo
Rear Clearance and Tail Lights
10.4 Streetside - Marker Lights
Comments: Yes
Streetside Marker Light Photos
Streetside Front Marker Light
Streetside Rear Marker Light
10.5 Curbside - Marker Lights
Comments: Yes
Curbside Marker Light Photos
Curbside Front Marker Light
Curbside Rear Marker Light
10.6 Left Turn and Brake Light
Comments: Yes
Left Turn Signal Photo
Left Turn Signal Light
10.7 Right Turn and Brake Light
Comments: Yes
Right Turn Signal Photo
Right Turn Signal
10.8 Hitch Lights
Comments: Yes
Hitch Light Photo
Hitch Light
10.9 Compartment Lights
Comments: Yes
Storage Compartment Lights
Storage Compartment Lights
10.10 Porch Lights
Comments: Yes
Porch and Awning Light Photos
Awning Light
Porch Light
10.11 Security Lights
Comments: Yes
Front Security Light Photo
Front Security Light
Top Table of Contents Bottom
11.  Electrical System 120-Volt AC and 12-Volt DC
Styles & Materials
Power Source:
30 Amp / 120 Volts AC
Power Cord Condition:
Acceptable
Inside Electrical Panel Box Condition:
Acceptable
12 Volt DC Fuse Panel Box Condition:
Acceptable
Fuses Condition:
All Operational
Fuse Connections Condition:
Good Connection
Wires and Terminals Tight:
Solid Connection
GFCI Testing - Circuit Breaker Panel Box:
Not Present
GFCI Testing - Bathroom:
Pass
GFCI Testing - Kitchen:
Pass
Power Converter - AC On:
Operational Test
DC Voltage with Shore Power On : 13.7
Power Converter - AC Off:
Operational Test
DC Voltage with Shore Power Off : 12.7
Power Converter - Verified:
Acceptable
Inverter - Brand:
Other
Other : WFCO
Inverter - Model:
From Manufacturer's Label
Model # : WF-5110RS
Inverter - Serial:
From Manufacturer's Label
Serial # : AC08T213602130
Inverter - General Condition:
Acceptable
Inverter Voltage Output:
Voltage Measured Under 50 Percent Load
Voltage Reading in AC Volts : 113
Inverter Frequency Output:
Frequency Measured Under Load
Frequency Reading in Hertz : 60
12 Volt DC House Battery - Location:
Other
Location of Battery Stack : On the tongue between the propane tanks and the front cap
12 Volt DC House Battery - Box Condition:
Acceptable
12 Volt DC House Battery - Cables and Terminals Condition:
Acceptable
12 Volt DC House Battery - Vented and Secure:
Yes
12-Volt DC House Battery - Water Level in Batteries:
Acceptable
Items
11.0 Hot Skin Test - Was any Frame and Running Gear Voltage Recorded
Comments: No
11.1 Hot Skin Test - Was any Exterior Wall Surface Voltage Recorded
Comments: No
One inspection point of the Hot Skin Test performed on the slideout.
Slideout Hot Skin Test
11.2 Hot Skin Test - Was any Door Handles and Frames Voltage Recorded
Comments: No
11.3 Hot Skin Test - Was any Window Frames and Trim Voltage Recorded
Comments: No
11.4 Hot Skin Test - Was any Other Voltage Recorded
Comments: No
11.5 Power Cord Inspected
Comments: Yes
The 30 Amp power cord was observed to be in acceptable condition with no signs of damage or corrosion.
30 Amp Power Cord (Pedestal End)
Power Cord (RV End)
RV Power Cord Receptacle
11.6 Electrical Panel Box - Signs of Repair or Service
Comments: No
Electrical Panel Box with converter mounted to the rear as observed by the fan.
Electrical Panel Box
11.7 Electrical Panel Box - Circuit Breakers in Place
Comments: Yes
11.8 Electrical Panel Box - Wiring with Signs of Discoloration from Heat
Comments: No
11.9 Electrical Panel Box - Wiring Secure
Comments: Yes
The 120 VAC side of the electrical panel box was in acceptable condition with no sign of heat damage or mis-wiring.
Electrical Panel Box, 120VAC Side
11.10 Electrical Panel Box - All White, Black and Ground Wires Kept Separate
Comments: Yes
11.11 Fuse Panel Box Inspected
Comments: Yes
All fuses in the 12VDC fuse panel box were found to be acceptable.
Electrical Panel Box, 12VDC Side
11.12 Polarity / Voltage Test - All Exterior Receptacles
Comments: Yes
The exterior electrical receptacle has acceptable voltage and is GFCI protected as required.
Exterior Receptacle Polarity/Voltage Test
11.13 Polarity / Voltage Test - Bedroom Receptacles
Comments: Yes
11.14 Polarity / Voltage Test - Receptacle Behind Refrigerator
Comments: Not Inspected
The receptacle behind the refrigerator was not accessible due to the fixed 12V refrigerator that had no access to the rear of the unit.
11.15 Polarity / Voltage Test - Kitchen Receptacles
Comments: Yes
The GFCI receptacle is located on the kitchen cabinet next to the front door entrance.
Kitchen Receptacle Voltage
Kitchen Receptacle Frequency
11.16 Polarity / Voltage Test - Bath and Toilet Area Receptacles
Comments: Yes
11.17 Polarity / Voltage Test - Receptacles Behind all Electronics and Appliances
Comments: Yes
TV Receptacle Photo
Receptacle Behind the TV
11.18 Voltage Test - USB Ports / 12-Volt Plugins
Comments: Yes
USB Port Photos
USB Port on Solar Controller
USB Port in Upper Bunkhouse Area
11.19 GFCI Trip Testing - Bathroom Receptacles
Comments: Yes
Bathroom Receptacle Photo
Bathroom Receptacle
11.20 GFCI Trip Testing - Kitchen Receptacles
Comments: Yes
11.21 GFCI Trip Testing - All Exterior Receptacles
Comments: Yes
11.22 GFCI Trip Testing - All Receptacles Behind Electronics and Appliances
Comments: Yes
11.23 Power Converter - Did DC Voltage Drop at Least 1/2 Volt
Comments: Yes
11.24 Inverter - Installed
Comments: Yes
The 1,000 Watt inverter is located under the bed on the curbside.
Inverter
11.25 Inverter - Inspected Cables, Wiring and Fuses
Comments: Yes
11.26 12-Volt DC House Battery(s) - Matched for Size and Age
Comments: Yes
11.27 12-Volt DC House Battery(s) - Positive and Negative Cables Matched for Load
Comments: Yes
11.28 12-Volt DC House Battery(s) - Have They Been Maintained?
Comments: Yes
Inspector observed two 12 Volt DC batteries were present in the House Battery Box. The battery box and connections were clean, and all connections were tight. A battery box cover was also present and in acceptable condition.
House Battery Box
House Battery Box with Cover Installed
11.29 12-Volt DC House Battery(s) - Operational
Comments: Yes
11.30 12 Volt DC House Battery - Water Level in Batteries
Comments: Yes
Top Table of Contents Bottom
12.  Water Systems
NOTE: Due to the inability to determine the age and quality of the water in the fresh water tank, the tank should be drained and sanitized before refilling for use.

NOTE: Due to the types of materials and waste used in the tanks and depending on previous maintenance, fresh and waste monitor sensor probes may perform inaccurately between applications due to build up.

Styles & Materials
City Water - Food Grade Hose Available for Test:
Yes
City Water - Pressure Regulator Available:
Yes
City Water - Connections Operate:
Yes
City Water - System Holds Pressure:
Yes
On-Board Water System - Tested Fresh Water Fill:
Yes
On-Board Water System - Pressure System Works:
Yes
On-Board Water System - Pump Creates and Holds Pressure:
Yes
Black Water Tank #1 - Valve Operates:
Yes
Black Water Tank #1 - Valve Type:
Manual Pull T-Handle
Black Water Tank #1 - Tank or Valve or Line Leaks:
No
Black Water Tank #1 - Drain Cap in Place:
Yes
Black Water Tank #1 - Drain Cap Holds Waste Water Back:
Yes
Gray Water Tank #1 - Valve Operates:
Yes
Gray Water Tank #1 - Valve Type:
Manual Pull T-Handle
Gray Water Tank #1 - Tank or Valve or Line Leaks:
No
Gray Water Tank - Drain Cap in Place:
Yes
Gray Water Tank - Drain Cap Holds Gray Water Back:
Yes
Battery Monitor Reading:
Full
NOTE: The Following Readings Should be AFTER Emptying Tanks if Possible:
Results of the Test
Fresh Water Tank Reading:
Empty
Black Water Tank #1 Reading:
Empty
Gray Water Tank #1 Reading:
Empty
   
Items
12.0 Operation and Condition of Outside Shower
Comments: Acceptable
The outside shower is functional and in acceptable condition.
Outside Shower
12.1 Onboard Water Filtration System
Comments: Acceptable
Onboard water filtration system located under the bed behind the water heater.
Water Filtration System
12.2 City Water Connection Condition
Comments: Acceptable
The city water connection point is in acceptable condition.
City Water Connection
12.3 On-Board Water System: Tank, Water Pump and Fixtures for Tank Fill Condition
Comments: Acceptable
(1) Inspector observed the fresh water tank electric heating pad is separating from the underside of the tank. Recommend the pad be repaired by a qualified RV technician.
(2) Fresh Water Fill Receptacle Photos
Fresh Water Fill Cap
Fresh Water Fill Receptacle
12.4 Waste Water Sewer / Hose Fittings
Comments: Acceptable
The sewer hose dump valves are in acceptable condition and operate smoothly.
Waste Water Sewer Hose Dump Valves
12.5 Black Water Tank #1
Comments: Acceptable
12.6 Gray Water Tank #1
Comments: Acceptable
Inspector observed the gray water tank electric heating pad is separating from the underside of the tank. Recommend the pad be repaired by a qualified RV technician.
Gray Tank Heating Pad
12.7 Battery / Waste / Water Monitor Panel Condition
Comments: Acceptable
The Battery/Waste/Water monitor panel is located on the side of the kitchen cabinet inside the main entrance.
Battery/Waste/Water Monitor Panel
Top Table of Contents Bottom
13.  Propane Tank, Lines and Connections
NOTE: LP Detectors have an estimated service life of 5 years after which time it is recommended they be replaced.

NOTE: CO Detectors have an estimated service life of 5 to 7 years after which time it is recommended they be replaced.

NOTE: Smoke Detectors have an estimated service life of 5 or 10 years after which time it is recommended they be replaced.

Styles & Materials
DOT Tank Location:
Where is the tank(s) located?
DOT Tank Location : On the tongue in front of the battery box.
DOT - Cylinder Arrangement:
Dual
DOT #1 - Cylinder Size:
20 LBS
DOT #1 - Date of Manufacture:
Other
Month / Other : 04/21
DOT Tank #1 - Rust or Damage Condition:
Acceptable
DOT #2 - Cylinder Size:
20 LBS
DOT #2 - Date of Manufacture:
Other
Month / Other : 04/21
DOT Tank #2 - Rust or Damage Condition:
Acceptable
DOT - Regulator Type:
Dual Input - Auto Change Over
DOT - Regulator Vents Downward:
Yes
DOT - Hoses and Regulators:
Acceptable
LP Leak / Drop Test:
Pass
LP Leak / Drop Test - Did Pressure Drop During Leak Test:
No
LP Leak / Drop Test - Begin Time:
Begin Time
Enter Start Time : 3:45 PM
LP Leak / Drop Test - Completed Time:
Stop Time
Enter Stop Time : 3:51 PM
LP Detector Test Result:
Pass
LP Detector Model / Serial Number:
Other
Other / Model / Serial # : RV Safe LLC / RVCOLP-2 / 1256073
LP Detector Date:
One Year Old
Date : 06 / 01 / 2021
LP Detector Test Method:
Tested by Pushing Button and Spraying LP
LP Detector Alarm During Test:
Yes
Carbon Monoxide Detector Test Result:
Pass
Carbon Monoxide Detector Model / Serial Number:
Other
Other / Model / Serial # : RV Safe LLC / RVCOLP-2 / 1256073
Carbon Monoxide Detector Date:
One Year Old
Date : 06 / 01 / 2021
Carbon Monoxide Detector Alarm During Test:
Yes, by Pushing the Button
Smoke Detector Test Result:
Pass
Smoke Detector Model / Serial Number:
Other
Other / Model / Serial # : Universal
Smoke Detector Date:
Three Years Old
Date : 02 / 28 / 2019
Smoke Detector Alarm During Test:
Yes, by Pushing the Button
Fire Extinguisher - Size:
Travel Trailer or 5th Wheel without Generator 5 B:C
Extra Info : 10 B:C
Fire Extinguisher - Secure in Bracket:
Yes
Fire Extinguisher - Mounted within 24 Inches of Entrance Door:
Yes
Fire Extinguisher - Gauge Indicates Charged State:
Yes
 
Items
13.0 DOT Cylinder(s)
Comments: Acceptable
DOT cylinder inspection is located on the cylinder handle and within the 10 year tolerance period.
DOT Cylinder Date
13.1 LP Leak System Test
Comments: Acceptable
Inspector performed an LP Leak Drop Test on the propane system. The system should charge to 11" WC, but this system was charging to 13" WC.When the system was bled down to 8" WC, no drop was detected after five minutes. Recommend the propane system be evaluated and repaired by a qualified RV technician to address the overcharging condition.
LP Leak / Drop Test Start Time
LP Leak / Drop Test End Time
13.2 LP Detector
Comments: Acceptable
The LP detector is a combination LP/Carbon Monoxide detector unit mounted within six inches of the kitchen floor to the right of the electrical panel box.
LP/CO Detector Front
LP / CO Detector Rear
13.3 Carbon Monoxide Detector
Comments: Acceptable
The Carbon monoxide detector is a combination LP/Carbon Monoxide detector unit mounted within six inches of the kitchen floor to the right of the electrical panel box.
13.4 Smoke Detector
Comments: Acceptable
The smoke detector is mounted on the streetside ceiling above the master bed.
Smoke Detector Interior
13.5 Fire Extinguisher
Comments: Acceptable
The fire extinguisher is of the correct size, charged, and located just inside the main entrance.
Fire Extinguisher Label with Size Displayed
Top Table of Contents Bottom
14.  Appliances: Kitchen
NOTE: Refrigerators need to be on for a minimum of 12 to 24 hours to be at full cooling condition. This inspection may not reveal a problem if during the inspection the refrigerator was not on for the minimum recommended time.
Styles & Materials
Refrigerator Brand:
MAGIC CHEF
Model # and Serial # : Model #: WD-127FDC Serial #: ZD2102-0145
Refrigerator Cooling Source(s):
12 Volt DC
Refrigerator: Operates on all Available Sources:
Yes
Refrigerator Type:
Residential
Refrigerator - Control Panel Location:
Inside Door
Refrigerator - Door Latch Secure:
Yes
Refrigerator - Freezer Current Temperature:
Degrees F
Degrees : 4
Refrigerator - Odor Detectable in Freezer:
No
Refrigerator - Current Refrigerator Temperature:
Degrees F
Degrees : 48
Refrigerator - Has Unit been Running 12 + Hours:
Yes
Refrigerator - Odor Detectable in Refrigerator:
No
Refrigerator - Does Inside Light Work:
Yes
Cooktop - Brand:
Magic Chef
Cooktop - All Burners Operate:
Yes
Cooktop - Rubber Grommets for Stovetop Grate:
Yes
Cooktop - Burner Ignition Source:
Piezo Ignition - Turn Knob to Create a Spark
Cooktop - All Burners Light:
Yes
Cooktop - Cover Matches Countertop Material:
Yes
Oven - Brand:
Magic Chef
Oven - Burner Ignition Source:
Piezo Ignition - Turn Knob to Create a Spark
Oven - Burner Lights:
Yes
Microwave - Brand:
MAGIC CHEF
Microwave - Type:
Microwave Only
Microwave - Temperature of Water after 60 Seconds:
Degrees F
Degrees : 144
Microwave - Rack and Turntables are Installed:
Yes
Cooktop Exhaust Vent - Part of Microwave:
No
Cooktop Exhaust Vent - Venting:
Vents to Exterior
Items
14.0 Refrigerator - User Control Panel
Comments: Acceptable
Inspector noted that the refrigerator and freezer had still not cooled down to the recommended temperature ranges for safe food storage after 24 hours of continuous operation. The outside temperature at the time of testing was 102 Degrees.
Refrigerator Temperature
Freezer Temperature
14.1 Refrigerator - Front Side Door Panels
Comments: Acceptable
Refrigerator Front Photo
Refrigerator Front
14.2 Refrigerator - Front Side Door Seals
Comments: Acceptable
Refrigerator Door Seal
Refrigerator Door Seal
14.3 Refrigerator - Front Side Door Frame
Comments: Acceptable
14.4 Refrigerator - Inside Freezer Walls
Comments: Acceptable
14.5 Refrigerator - Freezer Shelves / Door Racks
Comments: Acceptable
14.6 Refrigerator - Inside Walls
Comments: Acceptable
14.7 Refrigerator - Shelves / Door Racks
Comments: Acceptable
14.8 Refrigerator - Crisper Trays and Drawers
Comments: Acceptable
14.9 Cooktop - Condition
Comments: Acceptable
The glass cooktop cover is crack-and-stain-free.
14.10 Cooktop - Burner Grate / Cover Condition
Comments: Acceptable
Burner Grate Photo
Burner Grate
14.11 Cooktop - Condition of Knobs / Controls
Comments: Acceptable
Cooktop Knob Photo
Cooktop Knobs
14.12 Cooktop - Color of Burner Flame
Comments: Acceptable
The cooktop burner flame is blue with very little yellow flame evident.
Burner Flames
14.13 Oven - Condition
Comments: Acceptable
14.14 Oven - Racks Condition
Comments: Acceptable
Inspector observed no damage or staining within the oven.
Oven and Racks
14.15 Oven - Color of Burner Flame
Comments: Acceptable
The oven flame is a consistent blue throughout.
Oven Flame
14.16 Microwave - Condition
Comments: Acceptable
The microwave is acceptable and warmed a mug of water to 144 degrees in 60 seconds.
Microwave Water Test Result
14.17 Cooktop Exhaust Vent - Filter and Lighting Condition
Comments: Acceptable
14.18 Cooktop Exhaust Vent - Fan Speeds and Vent Condition
Comments: Acceptable
Top Table of Contents Bottom
15.  Appliances: Other
Styles & Materials
Water Heater - Brand:
Suburban
Water Heater - Type:
Tank Type
Water Heater - Heat Source(s):
Gas and Electric
Water Heater - Operates on all Sources:
Yes
Water Heater - Type of Ignition:
DSI and Electric
Water Heater - Leaks at Pressure Relief Valve:
No
Water Heater - Proper Drain Plug Installed:
Yes
Water Heater - Bypass Valves in Correct Position:
Yes
Water Heater - Dauber Screens Installed:
Yes
Furnace - Brand:
Other
Model # / Serial # : Airxcel Model #: NT-16SQ Model#: Not visible to inspector
Furnace - Operates:
Yes
Furnace - Floor Vents or Outside Exhaust Vents Blocked or Covered:
No
Furnace - Warm Air Discharge Out of Vents - Proper Return Air Flow:
Yes
Furnace - Dauber Screens Installed:
Yes
 
Items
15.0 Water Heater - Condition of Burner Assembly Area
Comments: Acceptable
Water Heater Photo
Water Heater Burner Assembly Area
15.1 Water Heater - Rubber Grommet Around Gas Line Sealed
Comments: Poor
Inspector observed no high temperature sealant was applied over gas line rubber grommet. Recommend sealant be applied over rubber grommet by a qualified RV technician to prevent possible LP leakage into the living space.
Water Heater Grommet Seal
15.2 Furnace #1 Air Intake / Exhaust Area Condition
Comments: Acceptable
Top Table of Contents Bottom
16.  Appliances: Air Conditioners
NOTE: The Delta-T average acceptable performance range is 14 to 22 degrees F (-10 to -5 degrees C). In high humidity areas the range may be lower (12 to 16 degrees F) (-11 to -9 degrees C) and in desert areas, it may be higher (23 to 26 degrees F) (-5 to -3 degrees C).
Styles & Materials
Air Conditioner - Brand:
Coleman
Model # / Serial # / Specify Other : Model #: 47,000 Series Serial #: Not visible to inspector
Air Conditioner - Options:
AC Only
Air Conditioner - Delta-T:
Degrees F
Degrees : 22
Items
16.0 Air Conditioner Condition
Comments: Acceptable
A/C Photos (Outside)
A/C Shroud (Rear)
A/C Shroud (Front)
16.1 Air Conditioner - Filter Condition
Comments: Acceptable
16.2 Air Conditioner - Exhaust Condition
Comments: Acceptable
The Delta-T test resulted in a value of 22 degrees.
A/C Intake Temperature
A/C Exhaust Temperature
Top Table of Contents Bottom
17.  Interior
NOTE: The inspector has verified the items in this section.
Interior 360 Photo (Near Front Entrance)
Interior 360 Photo (In Bathroom)
Styles & Materials
Ceiling - Condition:
Acceptable
Ceiling Vents and Skylights - Condition:
Acceptable
Ceiling Vents and Skylights - Trim Ring Around Vents and Skylights:
Acceptable
Lights and Light Fixtures - Condition:
Acceptable
Walls - Condition:
Acceptable
Walls - Interior Doors Condition:
Acceptable
Closets and Pantries - Condition:
Acceptable
Windows - Condition:
Acceptable
Flooring - Condition:
Acceptable
Kitchen Sink - Condition:
Acceptable
Kitchen Sink - Style:
Single Bowl
Kitchen Sink - Type:
Stainless
Shower / Tub - Condition:
Acceptable
Shower / Tub - Style:
Shower Tub Combo
Bathroom Sink - Condition:
Acceptable
Bathroom Sink - Style:
Single Bowl
Bathroom Sink - Type:
Plastic
 
Items
17.0 Ceiling Inspected
Comments: Yes
17.1 Ceiling - Panels Loose
Comments: No
17.2 Ceiling - Water Damaged Ceiling Panels
Comments: No
17.3 Ceiling - Discoloration or Stains
Comments: No
17.4 Ceiling - Trim Work Missing or Damaged
Comments: No
17.5 Ceiling Vents and Skylights - Thermostatic Controls and Switches Work
Comments: Yes
17.6 Ceiling Vents - All 12-Volt DC Fans Operate
Comments: Yes
17.7 Ceiling Vents and Skylights - Stains Around Roof Vents and Skylights
Comments: No
17.8 Lights and Light Fixtures - Do all 12-Volt DC Lights Function
Comments: Yes
17.9 Lights and Light Fixtures - Entry Lights inside RV
Comments: Yes
17.10 Lights and Light Fixtures - Missing or Broken Lenses
Comments: No
17.11 Lights and Light Fixtures - Missing Shades or Broken Covers
Comments: No
17.12 Walls Inspected
Comments: Yes
17.13 Walls - Panels Loose
Comments: No
17.14 Walls - Water Damaged Wall Panels
Comments: No
17.15 Walls - Panels Discolored or Stained
Comments: No
17.16 Walls - Soft Spots on Walls
Comments: No
17.17 Walls - Trim Work on Walls
Comments: Yes
17.18 Walls - Damage Repairs Performed
Comments: No
17.19 Walls - Holes or Wall Repairs
Comments: No
17.20 Closets / Pantries Inspected
Comments: Yes
17.21 Closets and Pantries - Door Damage / Scratches
Comments: No
17.22 Closets and Pantries - Wood Rot or Broken
Comments: No
17.23 Windows - All Windows Operational
Comments: Yes
17.24 Windows - Window Coverings
Comments: Yes
Valance over large dinette window is no longer held in place by its mounting screws. The valance was located on the dinette table at the time of the inspection and is in acceptable condition to be re-mounted.
Large Dining Area Window
Left End of Valance Mounting Above Dinette Window
17.25 Windows - Emergency Exit Windows Installed
Comments: Yes
17.26 Windows - Emergency Exit Windows Operational
Comments: Yes
17.27 Flooring - Sheet Vinyl
Comments: Yes
17.28 Flooring - Carpet
Comments: Yes
17.29 Flooring - Floor Panels Loose
Comments: No
17.30 Flooring - Floor Covering Discolored or Stained
Comments: No
17.31 Flooring - Water Damage
Comments: No
17.32 Flooring - Carpet Worn
Comments: No
17.33 Flooring - Sheet Vinyl Stained
Comments: No
17.34 Flooring - Soft Spots in Floor
Comments: No
17.35 Flooring - Previous Repairs Performed
Comments: No
17.36 Operation and Condition of Kitchen Faucet
Comments: Yes
17.37 Kitchen Sink - Faucet Working
Comments: Yes
17.38 Kitchen Sink - Faucet Leaks at Stem
Comments: No
17.39 Kitchen Sink - Water Damage Under Sink
Comments: No
17.40 Kitchen Sink - P-Trap Holds Water
Comments: Yes
17.41 Kitchen Sink - Sink(s) Holds Water
Comments: Yes
17.42 Kitchen Sink - Hot and Cold Water Available
Comments: Yes
17.43 Operation and Condition of Toilet
Comments: Yes
17.44 Toilet - Water Leaks
Comments: No
17.45 Toilet - Indication of Previous Damage or Repair
Comments: No
17.46 Toilet - Bowl Holds Water
Comments: Yes
17.47 Toilet - Mounting Problems
Comments: No
17.48 Operation and Condition of Shower
Comments: Yes
17.49 Shower / Tub - Stains, Chemical Buildup in Stall / Tub
Comments: No
17.50 Shower / Tub - Water Damage or Leaks
Comments: No
17.51 Shower / Tub - Soap Dish in Place
Comments: Yes
17.52 Shower / Tub - Curtain with Rod
Comments: Yes
17.53 Operation and Condition of Bathroom Faucet
Comments: Yes
17.54 Bathroom Sink - Faucet Working
Comments: Yes
17.55 Bathroom Sink - Faucet Leaks at Stem
Comments: No
17.56 Bathroom Sink - P-Trap Holds Water
Comments: Yes
17.57 Bathroom Sink - Sink(s) Holds Water
Comments: Yes
17.58 Bathroom Sink - Hot and Cold Water Available
Comments: Yes
Top Table of Contents Bottom
18.  Furniture
Styles & Materials
Dinette / Table / Chairs - Condition:
Acceptable
Beds - Condition:
Acceptable
Cabinets / Dressers - Condition:
Acceptable
Cabinets / Dressers - Types of Hinges:
Exposed / Hidden
Cabinets / Closet Hardware - Condition:
Acceptable
 
Items
18.0 Dinette / Table / Chairs Inspected
Comments: Yes
Dinette Photos
Dinette (Normal Configuration)
Dinette (Bed Configuration)
18.1 Dinette / Table / Chairs - Fabric Tears or Separation
Comments: No
18.2 Dinette / Table / Chairs - Fabric Discolored or Stains
Comments: No
18.3 Dinette / Table / Chairs - Signs of Excess Wear
Comments: No
18.4 Dinette / Table / Chairs - Water Damage
Comments: No
18.5 Dinette / Table / Chairs - Previous Repairs Performed
Comments: No
18.6 Beds Inspected
Comments: Yes
18.7 Beds - Fabric Tears or Separation
Comments: No
18.8 Beds - Fabric Discolored or Stains
Comments: No
18.9 Beds - Signs of Excess Wear
Comments: No
18.10 Beds - Pillow Top Mattress
Comments: No
18.11 Beds - Bed Covers
Comments: Yes
18.12 Beds - Covers Match Decor
Comments: Yes
18.13 Cabinets / Dressers Inspected
Comments: Yes
18.14 Cabinets / Dressers - Door Damage or Scratches
Comments: No
18.15 Cabinets / Dressers - Counter Top Damage or Scratches
Comments: No
18.16 Cabinets / Dressers - Wood Rot or Broken
Comments: No
18.17 Cabinets / Dressers - Drawer Damage or Scratches
Comments: No
18.18 Cabinet Doors / Drawers - Pull-Out Operation Acceptable
Comments: Yes
18.19 Cabinet Doors / Drawers - Previous Repairs Performed
Comments: No
Top Table of Contents Bottom
19(A) .  TV #1
Styles & Materials
Unit Brand:
Other
Model # / Other Specify : Furrion Model #: FDFD22A0A
Antenna Power Booster Operates:
Yes
TV Picks Up Local Channels:
Yes
Remotes Operational:
Yes
   
Items
19.0.A Unit Works Properly
Comments: Yes
Inspector found the TV and DVD player are in Acceptable condition.
TV
19.1.A Unit Cleaned and Maintained
Comments: Yes
19.2.A Unit Properly Mounted and Secured
Comments: Yes
Top Table of Contents Bottom
19(B) .  DVD Player
Styles & Materials
Unit Brand:
Other
Model # / Other Specify : DVD player is incorporated into TV
   
Items
19.0.B Unit Works Properly
Comments: Yes
The DVD player is integrated into the TV, and discs are inserted on the right end of the unit.
The TV operating in DVD mode.
DVD Player
19.1.B Unit Cleaned and Maintained
Comments: Yes
Top Table of Contents Bottom
19(C) .  Radio / Stereo
Styles & Materials
Unit Brand:
Other
Model # / Other Specify : iRV Model #: IRV36
Antenna Power Booster Operates:
Yes
TV Picks Up Local Channels:
Yes
Remotes Operational:
Yes
   
Items
19.0.C Unit Works Properly
Comments: Yes
The iRV radio controls are mounted in the cabinet above the TV, and allow the radio and TV to be heard through its speakers both inside and outside the RV. The outside speaker is mounted to the left of the front door.
iRV RADIO
Outside Speaker
Outside speaker
19.1.C Unit Cleaned and Maintained
Comments: Yes
19.2.C Unit Properly Mounted and Secured
Comments: Yes