General Information

# Of Stories:
2
Cooling System:
Central
Foundation Design:
Basement
Ground Conditions:
Dry
Heating System:
Boiler, Radiant Heat, Heat Pump
House Faces:
North
Location Of Attic Entrance:
Bedroom
Method To Inspect Attic:
On ladder
Method To Inspect Roof:
On roof, From ground, Inside attic
Occupancy:
Occupied
Present During Inspection:
Buyer, Buyer's agent, Seller's agent
Sewer System:
Septic system
Square Footage:
3900
Style Of Home:
Contemporary
Temperature:
55
Water Source:
Well-Private
Weather Conditions:
Sunny
Year Built:
1998

Summary

This summary represents the full list of observations made at the time of the inspection. This section is provided as a convenience to help navigation to more detailed information found in the body of the report. It is organized to indicate the significance of the observation.

Property Summary

Significant Concerns

i

Safety Concerns

  1. Balcony, Deck or PorchThe boards have deteriorated and were braced incorrectly.
  2. Balcony, Deck or PorchRailing is loose
  3. Balcony, Deck or PorchGuardrail is climbable
  4. StairHandrail is not graspable/ missing
  5. WindowWindows do not have stoppers
i

Items Not Operating

None

i

Major Concerns

None

i

Moderate Concerns

  1. DryerVent is damaged
  2. Balcony, Deck or PorchBoards are deteriorated
  3. EaveWood is showing rotting
  4. EaveWood is rotted as well as the rafter tail
  5. SidingStucco appears to be below grade
  6. Roof SheathingShows sign of mildew
  7. Electric Service PanelCrowded with excess wiring
  8. Chimney / FlueThe metal chimney cap is rusted/ damaged
  9. FireplaceFlue has creosote buildup
  10. InsulationAppears to have small burrow holes suggesting existence of rodents
  11. Patio and walkwayPaver or brick has significant settling
  12. Hose BibbNot winterized
  13. Stand-alone ShowerCaulking is defective
  14. Roof FlashingMissing cricket flashing around chimney
  15. CeilingDrywall tape at seam or joint has separation
  16. Exterior doorDoes not open
  17. ScreenSome missing Screens
  18. StairOpen Risers
  19. WallDrywall tape is delaminated
i

Minor Concerns

  1. Oven/RangeIn need of cleaning
  2. Balcony, Deck or PorchDecking is showing wear
  3. Electric Service PanelHas no available circuit breaker spaces
  4. Air ConditionerThere is not enough clearance in the attic to service the unit.
  5. FurnaceLast service date appears to be more than 1 year ago or is undeterminable
  6. InsulationThermal imaging shows minor inconsistencies in the thermal barrier
  7. Shower / TubShower head is clogged
  8. Attic EntryLess than 22 x 30 inches
  9. Exterior doorDamaged
  10. Garage door openerMissing safety chain
i

Budget to Replace

  1. CO AlarmCO alarms were present at the inspection, however they seemed to be older. I suggest testing/ replacement of each unit.
  2. Smoke AlarmRecommend replacing all smoke alarms
  3. Air ConditionerUnit appears to be original to the house
  4. FurnaceNearing the end of its useful life
  5. Roof MaterialNearing the end of its useful life
i

Needs Further Evaluation

  1. Column / PierWooden piers supporting the deck appear to be deteriorating.
  2. Roof MaterialMechanical damage on some spots
  3. Interior DoorMissing Tag
i

Items to Monitor

  1. GutterAppears to be in good condition, however possible leaks could not be tested, as the weather was dry.
  2. Foundation WallFoundation walls appear to be in good condition
  3. Air ConditionerNo pan under unit
  4. ToiletAll toilets in the house appeared to work correctly at the time of the inspection.
  5. Water HeaterAge could not be determined
  6. WellThe system appeared to be in working condition, although at some locations around the house, low pressure was noted
  7. CabinetKitchen Cabinets appeared to be in good condition
i

Maintenance Items

  1. Exterior doorDelaminating
  2. FloorFlooring was in good condition in general.

Scope of Inspection

  • An inspection does not determine the advisability or inadvisability of the purchase of the inspected property.
  • An inspection does not determine the life expectancy of the property or any components or systems therein.
  • An inspection is not technically exhaustive.
  • An inspection will not identify concealed or latent defects.
  • Mechanical and electrical systems can fail at any time, very often with no advance warning. Therefore, this report deals only with the condition of such systems at the time of inspection, and is not to be considered a guarantee or warranty as to future performance.
  • Seasonal changes such as wind-driven rain, ice, and humidity may bring some defects to light that were not noted during your home inspection. Basements and attics that were dry at the time of the inspection can be damp or leak in later weeks or months.
  • The condition of the premises may change after the date of inspection due to many factors such as weather, moisture, leaks, actions taken by the owner or others, or the passage of time. This report reflects the condition of the premises at the time of the inspection.
  • The inspection is performed in good faith and is a 'snapshot in time'; it does NOT constitute a prediction that the home will perform adequately in the future.
  • This home inspection is being conducted in accordance with the InterNACHI guidelines.
  • This home inspection is being conducted in accordance with the state Standard of Practice guidelines.
  • This is not a code compliance inspection. The local municipality should be contacted for any questions or concerns in relation to local building code.

Definitions

Each item has been assigned a quality rating based on the observations recorded by the inspector. The quality ratings are automatically assigned based on the observations made.

i
Not working
Was not working at the time of the inspection.
i
Safety Hazard
Has conditions that make operation of the item unsafe and is in need of prompt attention.
i
Poor
Is operating, but has at least one major concern with its operation.
i
Marginal
The item is working, but has at least one concern that is beyond cosmetic.
i
Satisfactory
No material issues have been found. One or more cosmetic issues may have been observed.
i
Not Inspected
Was not inspected. The reason is typically indicated.

1. Appliances

Descriptions

Dishwasher
Manufacturer Name
GE
Dryer
Energy Source
Electric
Manufacturer Name
GE
Venting Location
Wall
Garbage Disposal
Manufacturer Name
Insinkerator
Oven/Range
Energy Source
Gas
Manufacturer Name
GE
Refrigerator
Manufacturer Name
GE
Washer
Energy Source
Electric
Manufacturer Name
GE
c
i

Dishwasher

Kitchen
c
i

Dryer

Laundry Room / Mudroom
Vent is damaged
Impact
A damaged vent may cause the dryer vent to clog which means your appliance is not operating at its peak efficiency.  It also could pose a safety risk
Suggested Action
Replace the vent to allow for an optimum air flow

Photos

c
i

Garbage Disposal

Kitchen
Unit is in good condition

Photos

c
i

Oven/Range

Kitchen
In need of cleaning
Suggested Action
Thoroughly clean as needed

Photos

Unit is in good condition

Photos

c
i

Refrigerator

Kitchen
Unit is in good condition

Photos

c
i

Washer

Laundry Room / Mudroom

Disclaimers

Evaluation of the washer is beyond the scope of the standard home inspection.

2. Balconies, Decks and Porches

Descriptions

Balcony, Deck or Porch
Material
Wood
Type
Deck
c
i

Balcony, Deck or Porch

Exterior: Ground View
The boards have deteriorated and were braced incorrectly. 
Impact
The splintering diminishes the structural integrity of the planking. 
Suggested Action
Replace the deteriorating boards
Railing is loose
Impact
The stability of the railing is significantly reduced
Suggested Action
Repair or replace the railing

Photos

Guardrail is climbable
Impact
A guardrail that is climbable becomes a falling hazard for children
Suggested Action
Repair or replace the guardrail to meet the modern code
Other Information
A guardrail is the barrier that prevents you from falling off a deck, porch, mezzanine, or the side of stairs

Photos

Boards are deteriorated
Impact
The splintering dimishes the structural integrity of the planking
Suggested Action
Replace the deteriorating boards
Decking is showing wear
Impact
If not protected from the elements, the decking may prematurely wear
Suggested Action
Paint, stain and/or seal with a weatherproof product

3. Building Exterior

Descriptions

Downspout
Drainage Location
Below grade
Material
Aluminum
Eave
Fascia Material
Wood
Soffit Material
Wood
Gutter
Material
Aluminum
Type
Eave Mounted
Siding
Material
EIFS
c
i

Downspout

Exterior: Ground View
Appears to be in good condition
c
i

Eave

Exterior: Ground View
Wood is showing rotting
Impact
The rotted areas lacks protection from insects, animals and the elements and the supporting structure for the fascia board is lacking
Suggested Action
Have the damaged area(s) replaced by a roofing contractor
Wood is rotted as well as the rafter tail
Impact
The rotted areas lacks protection from insects, animals and the elements and the supporting structure for the fascia board is lacking
Suggested Action
Have the damaged area(s) replaced by a roofing contractor

Photos

c
i

Exhaust Vent

Exterior: Ground View
c
i

Gutter

Exterior: Ground View
Appears to be in good condition, however possible leaks could not be tested, as the weather was dry.
Suggested Action
Monitor the condition and repair/ replace as necessary

Photos

c
i

Siding

Exterior: Ground View
Stucco appears to be below grade
Impact
When the stucco is below grade it wicks moisture and exposes the siding to insect infiltration. 
Suggested Action
Have a certified stucco contractor check/ repair the affected areas

Photos

4. Building Structure

Descriptions

Beam
Material
Wood
Column / Pier
Material
Steel, Wood
Foundation Wall
Material
Poured Concrete
Joist
Material
Wood
Type
Solid board
Roof Sheathing
Flashing Material
Composite
Material
Gypsum Board
Roof Structure
Framing Type
Rafter
Roof Pitch
Medium
Roof Style
Gable
c
i

Beam

Attic
c
i

Column / Pier

Basement
Wooden piers supporting the deck appear to be deteriorating.
Suggested Action
I suggest monitoring and repairing/replacing as necessary by a qualified contractor

Photos

Metal columns holding up the deck appear to be in good condition

Photos

c
i

Foundation Wall

Exterior: Ground View

Disclaimers

Some parts of the foundation walls were not visible and could not be inspected.
Foundation walls appear to be in good condition
Suggested Action
I suggest monitoring 
c
i

Joist

Attic

Disclaimers

The attic is very tight and some areas are inaccessible. I could not inspect the entire attic.
Appeared to be in good condition
c
i

Rafter

c
i

Rafter Tail

c
i

Roof Sheathing

Exterior: Roof View
Shows sign of mildew
Impact
May lead to microbial growth potentially causing damage to roof decking
Suggested Action
Add additional ventilation to allow moisture to evaporate and clean mildew as needed.  Monitor to ensure mildew does not reoccur
c
i

Roof Structure

Exterior: Roof View

5. Electrical

Descriptions

Electric Service Panel
# of 110 Volt Circuits
1
Manufacturer Name
Thomas & Betts
Panel Rating
200 Amp
Panel Type
Circuit breakers
Wiring Type - Distribution
Copper
Electrical service
Location Of Main Disconnect
Basement
Rating
200 amps
Service Entry Style
Underground
c
i

AFCI

c
i

CO Alarm

CO alarms were present at the inspection, however they seemed to be older. I suggest testing/ replacement of each unit.

Photos

c
i

Ceiling Fan

c
i

Door Bell

Exterior: Ground View
c
i

Electric Service Panel

Crowded with excess wiring
Impact
A crowded panel makes it difficult to work on the panel
Suggested Action
Have improved by a qualified electrician
Has no available circuit breaker spaces
Impact
With a full panel, adding more circuits is impossible without adding a sub-panel or a larger service panel
Suggested Action
Add sub-panel or larger service panel if you need to add more circuits
c
i

Electrical service

Exterior: Ground View

Disclaimers

The ground rod is apparently below grade and was not visible at the time of this inspection.
c
i

GFCI

c
i

Light Fixture

c
i

Outlet

Appears to be in good working order

Photos

c
i

Security System

Disclaimers

Security systems are not included in a home inspection
c
i

Smoke Alarm

Recommend replacing all smoke alarms

Photos

c
i

Switch

c
i

Whole House Fan

Attic
c
i

Wiring

6. Fireplace and Chimney

Descriptions

Chimney / Flue
Chimney Chase Material
Metal Undersiding
Flue Material
Metal
Location Inspected Chimney
Exterior
Viewed From
From Roof
Fireplace
Energy Source
Wood
Firebox Material
Metal Insert
c
i

Chimney / Flue

The metal chimney cap is rusted/ damaged
Impact
This may allow water or moisture to enter the chimney chase causing damage to the brick and mortar
Suggested Action
Have repaired by a qualified contractor.  Repairs may include caulking and sealing to prevent moisture intrusion and /or further degradation
Other Information
Chimney cap is designed to cover the chimney chase and surround the flue(s) with a weather-tight seal

Photos

c
i

Fireplace

Disclaimers

It is always advisable to have your chimney/ fireplace evaluated and cleaned yearly by a licensed chimney sweep.
Flue has creosote buildup
Impact
With too much creosote, the chimney could ignite
Suggested Action
Have cleaned by a chimney sweep

7. HVAC

Descriptions

AC-Condenser
Capacity
5 Ton
Energy Source
Electric
Manufacturer
Ameristar
Maximum Fuse / Breaker Rating
30
Serial Number
155210348M
Type
Cased
Year Built
2015
Air Conditioner
Air Conditioner Type
Packaged
Air Distribution Method
Ducts
Capacity
1.5 Ton
Condensing Type
Air
Energy Source
Electric
Installed Fuse Breaker
60
Manufacturer Name
York
Model Number
n-ahc1606a
Type
Cased
Year Built
1998
Furnace
Efficiency
Mid-efficiency
Energy Source
Oil
Heat Distribution Type
Forced Air, Hydronic
Manufacturer Name
Burnham
Model Number
PV75WT
Year Built
1998
HVAC Venting
Material
Metal
c
i

AC-Condenser

Exterior: Ground View

Disclaimers

AC Not tested as temperature was below 65 degrees Fahrenheit
c
i

AC-Evaporator Coil

c
i

Air Conditioner

Attic

Disclaimers

The air conditioner could not be tested because the temperature was below 65 when it it unsafe to run the air conditioner.
Unit appears to be original to the house
Suggested Action
Budget for replacement
There is not enough clearance in the attic to service the unit. 

Photos

No pan under unit
Impact
If the unit leaks, it could cause damage to the drywall and decking below. 
c
i

Ductwork

Attic
c
i

Furnace

Last service date appears to be more than 1 year ago or is undeterminable
Impact
Without regular servicing, the furnace may not operate as efficiently as possible
Suggested Action
Ask the property owners when the furnace was last serviced.   If it was more than a year ago, have inspected, cleaned and serviced by an HVAC professional and schedule annual servicing in the future
Nearing the end of its useful life
Suggested Action
Budget for a newer unit.  In the interim, a higher level of maintenance can be expected
c
i

HVAC Venting

Attic
c
i

Register / Return

c
i

Thermostat

8. Insulation and Ventilation

Descriptions

Attic Ventilation
Type
Soffit, Ridge
Insulation
Insulation Style
Fiberglass batting
R-value
about 4.3 per inch
Kitchen / Bath Exhaust
Type
Vented
c
i

Attic Ventilation

Attic
c
i

Basement / Crawl Space Ventilation

Basement
c
i

Insulation

Attic

Disclaimers

The insulation behind finished walls could not be inspected.
Appears to have small burrow holes suggesting existence of rodents
Impact
The holes reduce insulation effectiveness and may get worse if the rodents are still present
Suggested Action
Have a pest control company evaluate for treatment
Thermal imaging shows minor inconsistencies in the thermal barrier
Impact
The heat loss and cost of energy is reduced with inadequate insulation
Suggested Action
Have a contractor evaluate the areas where the insulation is reduced and recommend improvements
Other Information
Thermal imaging highlights areas that are warmer or colder than the surrounding areas showing potential gaps in the thermal barrier of the home
c
i

Kitchen / Bath Exhaust

Attic
c
i

Power Vent

Exterior: Ground View

9. Landscaping and Hardscaping

Descriptions

Driveway
Material
Asphalt
Patio and walkway
Material
Pavers
c
i

Drainage and Grading

Exterior: Ground View
c
i

Driveway

Exterior: Ground View
Appears to be in good condition

Photos

c
i

Patio and walkway

Exterior: Ground View
Paver or brick has significant settling
Impact
The settling may allow moisture intrusion further damaging surrounding material
Suggested Action
Remove the pavers, repair the base and reinstall the pavers

Photos

10. Plumbing

Descriptions

Fuel Lines
Material
Copper
Main fuel supply
Location fuel filler
Next to Garage
Main water valve
Main Water Supply Valve Location
Basement
Shutoff Location
Basement
Static Water Pressure Reading
Low water pressure
Water Meter Location
Basement
Septic System
Leach Field Location
Next to house
Shower / Tub
Material
Cast Polymer
Type
Drop-in
Sink
Mounting
Top-mounted
Number Of Bowls
Double Bowl
Type (Bathroom)
Vanity Mount
Water Heater
Capacity
40 gal
Energy Source
Fuel oil
Type
Recovery
Water Pipe
Water Distribution Piping Material
Copper
Well
Pump Type
Jet Pump
Storage Equipment Type
Metal tanks
Well Cap Type
Sanitary
c
i

Cleanout

c
i

Ejector pump

Basement
c
i

Floor drain

c
i

Foundation drainage system

Basement
c
i

Fuel Lines

Disclaimers

Fuel lines were behind finished walls and could not be fully inspected. They appeared to be in working order.
c
i

Fuel Storage Tank

Exterior: Ground View

Disclaimers

The tank is an underground, buried oil tank; it could not be tested. 
c
i

Hose Bibb

Exterior: Ground View
Not winterized
Impact
Non freeze-resistant hose bibbs should be winterized or they could freeze and cause the pipes to break
Suggested Action
Turn off all water to the bibb and disconnect any garden hoses
c
i

Main fuel supply

Exterior: Ground View
c
i

Main water valve

Exterior: Ground View
c
i

Plumbing Vent

Exterior: Roof View
c
i

Septic System

Exterior: Ground View

Disclaimers

Testing the septic system is not part of a home inspection.
c
i

Shower / Tub

Bathroom
Shower head is clogged
Impact
The clog is restricting the water flow
Suggested Action
Clean with a calcium removing product such as CLR or replace the shower head
c
i

Sink

In good working order
c
i

Stand-alone Shower

Bathroom
Caulking is defective
Impact
Water could get behind the pan and cause damage
Suggested Action
I suggest recaulking by a qualified contractor

Photos

c
i

Toilet

Bathroom
All toilets in the house appeared to work correctly at the time of the inspection. 

Photos

c
i

Waste Discharge Pipe

Disclaimers

The waste discharge pipe was not inspected because it was not visible.
c
i

Water Heater

Disclaimers

The age and manufacturer of the unit could not be determined, as it was covered with an insulating sleeve. 
Age could not be determined
Suggested Action
Ask the sellers when it was replaced, or if it is original to the house. Budget for replacement

Photos

c
i

Water Pipe

c
i

Well

Exterior: Ground View
The system appeared to be in working condition, although at some locations around the house, low pressure was noted

11. Roof

Descriptions

Roof Material
Approximate Age
20+ years
Roof Material
Asphalt (Architectural)
c
i

Roof Flashing

Exterior: Roof View
Missing cricket flashing around chimney
Impact
The decking is at risk of premature aging due to exposure to the elements and may cause roof leaking
Suggested Action
Consult with a roofing professional for suggested improvement
c
i

Roof Material

Exterior: Roof View
Mechanical damage on some spots
Impact
Water can seep through the damaged areas and cause further damage below.
Suggested Action
Have a roofing contractor evaluate the damage and repair/ replace as necessary

Photos

Nearing the end of its useful life
Suggested Action
Budget for a newer unit.  In the interim, a higher level of maintenance can be expected

12. Room Components

Descriptions

Cabinet
Cabinet Construction
Metal Brackets
Material
Laminate
Ceiling
Material
Drywall
Countertop
Material
Granite
Exterior door
Materials
Glass, Wood
Floor
Floor Cover
Carpet, Tile, Hardwood
Sub Floor Material
Plywood
Garage door opener
Manufacturer
Liftmaster
Type
Chain Drive
Interior Door
Materials
Metal
Style
Flush
Overhead Door
Material
Aluminum
Screen
Material
Vinyl
Stair
Rail Material
Iron, Wood
Stair Covering
Wood
Wall
Material
Drywall
Window
Window Frame Type
Vinyl
Window Glass Type
Double pane
Window Type
Casement
c
i

Attic Entry

Less than 22 x 30  inches
Impact
The smaller size makes access to the attic more difficult
Suggested Action
Enlarging the access should the  size become an issue
c
i

Cabinet

Kitchen Cabinets appeared to be in good condition

Photos

c
i

Ceiling

Drywall tape at seam or joint has separation
Impact
With separation, the wall lacks astethic appeal
Suggested Action
Remove the drywall tape, reapply new tape and drywall compound.  Once repaired, manage the humidity levels in the home such that moisture levels are in the range of 35% to 50%

Photos

c
i

Countertop

c
i

Exterior door

Exterior: Ground View
Does not open
Impact
A faulty exterior door removes a possible exit in case of an emergency
Suggested Action
Repair or replace the door depending on your preference
Damaged
Suggested Action
Repair the damage or replace the door depending on your preference

Photos

Delaminating
Impact
The delamination reduces the asthetic appeal of the door
Suggested Action
Replace the door
Other Information
Delamination is the loss of coating adhesion to a surface or between coating layers.  Delamination tends to destroy the strength and durability of the coating, as well as the aesthetic appearance

Photos

c
i

Floor

Flooring was in good condition in general.
Suggested Action
I suggest cleaning/ replacing the carpets in the bedrooms prior to moving in.
c
i

Garage door opener

Garage
Missing safety chain

Photos

c
i

Interior Door

Missing Tag 
Impact
The door is self-closing and appears to be fire-rated, however, the tag is missing so it can not be determined if it is in fact, fire-rated
Suggested Action
Replace with fire-rated door
c
i

Overhead Door

Garage
c
i

Screen

Some missing Screens
Impact
Should the window be open, lacks protection from insects
Suggested Action
Consult with seller to identify if screens exist.  If they do not, install screens as needed
c
i

Stair

Open Risers
Impact
Open risers are a safety concern, as a small child could fall through
Suggested Action
Replace the staircase with one, that does not have open risers.

Photos

Handrail is not graspable/ missing
Impact
A missing/ non-graspable handrail could hinder the stair user an opportunity to stop or reduce the extent of a fall
Suggested Action
Install a graspable handrail

Photos

c
i

Vanity

Bathroom
c
i

Wall

Drywall tape is delaminated
Impact
The delamination may continue requiring the drywall tape to be replaced
Suggested Action
Remove and retape the damaged areas
c
i

Window

Windows do not have stoppers
Impact
A person (especially a child) could open the window and climb onto the roof, or fall out.
Suggested Action
Install window stoppers to prevent falls.

Photos