Inspection Report
Halstead Avenue, Harrison, New York 10528

Inspection Date
Feb 11, 2023
Company
Astra Inspections LLC
Inspector
Eugen Juhasz
General Information
# Of Stories:
2
Cooling System:
Central
Foundation Design:
Basement
Ground Conditions:
Dry
Heating System:
Boiler, Radiant Heat, Heat Pump
House Faces:
North
Location Of Attic Entrance:
Bedroom
Method To Inspect Attic:
On ladder
Method To Inspect Roof:
On roof, From ground, Inside attic
Occupancy:
Occupied
Present During Inspection:
Buyer, Buyer's agent, Seller's agent
Sewer System:
Septic system
Square Footage:
3900
Style Of Home:
Contemporary
Temperature:
55
Water Source:
Well-Private
Weather Conditions:
Sunny
Year Built:
1998
Summary
This summary represents the full list of observations made at the time of the inspection. This section is provided as a convenience to help navigation to more detailed information found in the body of the report. It is organized to indicate the significance of the observation.
Property Summary
Significant Concerns
Safety Concerns
- Balcony, Deck or Porch: The boards have deteriorated and were braced incorrectly.
- Balcony, Deck or Porch: Railing is loose
- Balcony, Deck or Porch: Guardrail is climbable
- Stair: Handrail is not graspable/ missing
- Window: Windows do not have stoppers
Items Not Operating
None
Major Concerns
None
Moderate Concerns
- Dryer: Vent is damaged
- Balcony, Deck or Porch: Boards are deteriorated
- Eave: Wood is showing rotting
- Eave: Wood is rotted as well as the rafter tail
- Siding: Stucco appears to be below grade
- Roof Sheathing: Shows sign of mildew
- Electric Service Panel: Crowded with excess wiring
- Chimney / Flue: The metal chimney cap is rusted/ damaged
- Fireplace: Flue has creosote buildup
- Insulation: Appears to have small burrow holes suggesting existence of rodents
- Patio and walkway: Paver or brick has significant settling
- Hose Bibb: Not winterized
- Stand-alone Shower: Caulking is defective
- Roof Flashing: Missing cricket flashing around chimney
- Ceiling: Drywall tape at seam or joint has separation
- Exterior door: Does not open
- Screen: Some missing Screens
- Stair: Open Risers
- Wall: Drywall tape is delaminated
Minor Concerns
- Oven/Range: In need of cleaning
- Balcony, Deck or Porch: Decking is showing wear
- Electric Service Panel: Has no available circuit breaker spaces
- Air Conditioner: There is not enough clearance in the attic to service the unit.
- Furnace: Last service date appears to be more than 1 year ago or is undeterminable
- Insulation: Thermal imaging shows minor inconsistencies in the thermal barrier
- Shower / Tub: Shower head is clogged
- Attic Entry: Less than 22 x 30 inches
- Exterior door: Damaged
- Garage door opener: Missing safety chain
Budget to Replace
- CO Alarm: CO alarms were present at the inspection, however they seemed to be older. I suggest testing/ replacement of each unit.
- Smoke Alarm: Recommend replacing all smoke alarms
- Air Conditioner: Unit appears to be original to the house
- Furnace: Nearing the end of its useful life
- Roof Material: Nearing the end of its useful life
Needs Further Evaluation
- Column / Pier: Wooden piers supporting the deck appear to be deteriorating.
- Roof Material: Mechanical damage on some spots
- Interior Door: Missing Tag
Items to Monitor
- Gutter: Appears to be in good condition, however possible leaks could not be tested, as the weather was dry.
- Foundation Wall: Foundation walls appear to be in good condition
- Air Conditioner: No pan under unit
- Toilet: All toilets in the house appeared to work correctly at the time of the inspection.
- Water Heater: Age could not be determined
- Well: The system appeared to be in working condition, although at some locations around the house, low pressure was noted
- Cabinet: Kitchen Cabinets appeared to be in good condition
Maintenance Items
- Exterior door: Delaminating
- Floor: Flooring was in good condition in general.
Scope of Inspection
- An inspection does not determine the advisability or inadvisability of the purchase of the inspected property.
- An inspection does not determine the life expectancy of the property or any components or systems therein.
- An inspection is not technically exhaustive.
- An inspection will not identify concealed or latent defects.
- Mechanical and electrical systems can fail at any time, very often with no advance warning. Therefore, this report deals only with the condition of such systems at the time of inspection, and is not to be considered a guarantee or warranty as to future performance.
- Seasonal changes such as wind-driven rain, ice, and humidity may bring some defects to light that were not noted during your home inspection. Basements and attics that were dry at the time of the inspection can be damp or leak in later weeks or months.
- The condition of the premises may change after the date of inspection due to many factors such as weather, moisture, leaks, actions taken by the owner or others, or the passage of time. This report reflects the condition of the premises at the time of the inspection.
- The inspection is performed in good faith and is a 'snapshot in time'; it does NOT constitute a prediction that the home will perform adequately in the future.
- This home inspection is being conducted in accordance with the InterNACHI guidelines.
- This home inspection is being conducted in accordance with the state Standard of Practice guidelines.
- This is not a code compliance inspection. The local municipality should be contacted for any questions or concerns in relation to local building code.
Definitions
Each item has been assigned a quality rating based on the observations recorded by the inspector. The quality ratings are automatically assigned based on the observations made.
Not working
Was not working at the time of the inspection.
Safety Hazard
Has conditions that make operation of the item unsafe and is in need of prompt attention.
Poor
Is operating, but has at least one major concern with its operation.
Marginal
The item is working, but has at least one concern that is beyond cosmetic.
Satisfactory
No material issues have been found. One or more cosmetic issues may have been observed.
Not Inspected
Was not inspected. The reason is typically indicated.
1. Appliances
Descriptions
Dishwasher
Manufacturer Name
GE
Dryer
Energy Source
Electric
Manufacturer Name
GE
Venting Location
Wall
Garbage Disposal
Manufacturer Name
Insinkerator
Oven/Range
Energy Source
Gas
Manufacturer Name
GE
Refrigerator
Manufacturer Name
GE
Washer
Energy Source
Electric
Manufacturer Name
GE
Dishwasher
Kitchen
Dryer
Laundry Room / Mudroom
Washer
Laundry Room / Mudroom
Disclaimers
Evaluation of the washer is beyond the scope of the standard home inspection.
2. Balconies, Decks and Porches
Descriptions
Balcony, Deck or Porch
Material
Wood
Type
Deck
Balcony, Deck or Porch
Exterior: Ground View
Decking is showing wear
Impact
If not protected from the elements, the decking may prematurely wear
Suggested Action
Paint, stain and/or seal with a weatherproof product
3. Building Exterior
Descriptions
Downspout
Drainage Location
Below grade
Material
Aluminum
Eave
Fascia Material
Wood
Soffit Material
Wood
Gutter
Material
Aluminum
Type
Eave Mounted
Siding
Material
EIFS
Downspout
Exterior: Ground View
Appears to be in good condition
Eave
Exterior: Ground View
Wood is showing rotting
Impact
The rotted areas lacks protection from insects, animals and the elements and the supporting structure for the fascia board is lacking
Suggested Action
Have the damaged area(s) replaced by a roofing contractor
Exhaust Vent
Exterior: Ground View
4. Building Structure
Descriptions
Beam
Material
Wood
Column / Pier
Material
Steel, Wood
Foundation Wall
Material
Poured Concrete
Joist
Material
Wood
Type
Solid board
Roof Sheathing
Flashing Material
Composite
Material
Gypsum Board
Roof Structure
Framing Type
Rafter
Roof Pitch
Medium
Roof Style
Gable
Beam
Attic
Foundation Wall
Exterior: Ground View
Disclaimers
Some parts of the foundation walls were not visible and could not be inspected.
Foundation walls appear to be in good condition
Suggested Action
I suggest monitoring
Rafter
Rafter Tail
Roof Sheathing
Exterior: Roof View
Shows sign of mildew
Impact
May lead to microbial growth potentially causing damage to roof decking
Suggested Action
Add additional ventilation to allow moisture to evaporate and clean mildew as needed. Monitor to ensure mildew does not reoccur
Roof Structure
Exterior: Roof View
5. Electrical
Descriptions
Electric Service Panel
# of 110 Volt Circuits
1
Manufacturer Name
Thomas & Betts
Panel Rating
200 Amp
Panel Type
Circuit breakers
Wiring Type - Distribution
Copper
Electrical service
Location Of Main Disconnect
Basement
Rating
200 amps
Service Entry Style
Underground
AFCI
Ceiling Fan
Door Bell
Exterior: Ground View
Electric Service Panel
Crowded with excess wiring
Impact
A crowded panel makes it difficult to work on the panel
Suggested Action
Have improved by a qualified electrician
Electrical service
Exterior: Ground View
Disclaimers
The ground rod is apparently below grade and was not visible at the time of this inspection.
GFCI
Light Fixture
Security System
Disclaimers
Security systems are not included in a home inspection
Switch
Whole House Fan
Attic
Wiring
6. Fireplace and Chimney
Descriptions
Chimney / Flue
Chimney Chase Material
Metal Undersiding
Flue Material
Metal
Location Inspected Chimney
Exterior
Viewed From
From Roof
Fireplace
Energy Source
Wood
Firebox Material
Metal Insert
Chimney / Flue
The metal chimney cap is rusted/ damaged
Impact
This may allow water or moisture to enter the chimney chase causing damage to the brick and mortar
Suggested Action
Have repaired by a qualified contractor. Repairs may include caulking and sealing to prevent moisture intrusion and /or further degradation
Other Information
Chimney cap is designed to cover the chimney chase and surround the flue(s) with a weather-tight seal
7. HVAC
Descriptions
AC-Condenser
Capacity
5 Ton
Energy Source
Electric
Manufacturer
Ameristar
Maximum Fuse / Breaker Rating
30
Serial Number
155210348M
Type
Cased
Year Built
2015
Air Conditioner
Air Conditioner Type
Packaged
Air Distribution Method
Ducts
Capacity
1.5 Ton
Condensing Type
Air
Energy Source
Electric
Installed Fuse Breaker
60
Manufacturer Name
York
Model Number
n-ahc1606a
Type
Cased
Year Built
1998
Furnace
Efficiency
Mid-efficiency
Energy Source
Oil
Heat Distribution Type
Forced Air, Hydronic
Manufacturer Name
Burnham
Model Number
PV75WT
Year Built
1998
HVAC Venting
Material
Metal
AC-Condenser
Exterior: Ground View
Disclaimers
AC Not tested as temperature was below 65 degrees Fahrenheit
AC-Evaporator Coil
Air Conditioner
Attic
Disclaimers
The air conditioner could not be tested because the temperature was below 65 when it it unsafe to run the air conditioner.
Ductwork
Attic
Furnace
Last service date appears to be more than 1 year ago or is undeterminable
Impact
Without regular servicing, the furnace may not operate as efficiently as possible
Suggested Action
Ask the property owners when the furnace was last serviced. If it was more than a year ago, have inspected, cleaned and serviced by an HVAC professional and schedule annual servicing in the future
HVAC Venting
Attic
Register / Return
Thermostat
8. Insulation and Ventilation
Descriptions
Attic Ventilation
Type
Soffit, Ridge
Insulation
Insulation Style
Fiberglass batting
R-value
about 4.3 per inch
Kitchen / Bath Exhaust
Type
Vented
Attic Ventilation
Attic
Basement / Crawl Space Ventilation
Basement
Insulation
Attic
Disclaimers
The insulation behind finished walls could not be inspected.
Appears to have small burrow holes suggesting existence of rodents
Impact
The holes reduce insulation effectiveness and may get worse if the rodents are still present
Suggested Action
Have a pest control company evaluate for treatment
Thermal imaging shows minor inconsistencies in the thermal barrier
Impact
The heat loss and cost of energy is reduced with inadequate insulation
Suggested Action
Have a contractor evaluate the areas where the insulation is reduced and recommend improvements
Other Information
Thermal imaging highlights areas that are warmer or colder than the surrounding areas showing potential gaps in the thermal barrier of the home
Kitchen / Bath Exhaust
Attic
Power Vent
Exterior: Ground View
9. Landscaping and Hardscaping
Descriptions
Driveway
Material
Asphalt
Patio and walkway
Material
Pavers
Drainage and Grading
Exterior: Ground View
10. Plumbing
Descriptions
Fuel Lines
Material
Copper
Main fuel supply
Location fuel filler
Next to Garage
Main water valve
Main Water Supply Valve Location
Basement
Shutoff Location
Basement
Static Water Pressure Reading
Low water pressure
Water Meter Location
Basement
Septic System
Leach Field Location
Next to house
Shower / Tub
Material
Cast Polymer
Type
Drop-in
Sink
Mounting
Top-mounted
Number Of Bowls
Double Bowl
Type (Bathroom)
Vanity Mount
Water Heater
Capacity
40 gal
Energy Source
Fuel oil
Type
Recovery
Water Pipe
Water Distribution Piping Material
Copper
Well
Pump Type
Jet Pump
Storage Equipment Type
Metal tanks
Well Cap Type
Sanitary
Cleanout
Ejector pump
Basement
Floor drain
Foundation drainage system
Basement
Fuel Lines
Disclaimers
Fuel lines were behind finished walls and could not be fully inspected. They appeared to be in working order.
Fuel Storage Tank
Exterior: Ground View
Disclaimers
The tank is an underground, buried oil tank; it could not be tested.
Hose Bibb
Exterior: Ground View
Not winterized
Impact
Non freeze-resistant hose bibbs should be winterized or they could freeze and cause the pipes to break
Suggested Action
Turn off all water to the bibb and disconnect any garden hoses
Main fuel supply
Exterior: Ground View
Main water valve
Exterior: Ground View
Plumbing Vent
Exterior: Roof View
Septic System
Exterior: Ground View
Disclaimers
Testing the septic system is not part of a home inspection.
Shower / Tub
Bathroom
Shower head is clogged
Impact
The clog is restricting the water flow
Suggested Action
Clean with a calcium removing product such as CLR or replace the shower head
Waste Discharge Pipe
Disclaimers
The waste discharge pipe was not inspected because it was not visible.
Water Pipe
11. Roof
Descriptions
Roof Material
Approximate Age
20+ years
Roof Material
Asphalt (Architectural)
Roof Flashing
Exterior: Roof View
Missing cricket flashing around chimney
Impact
The decking is at risk of premature aging due to exposure to the elements and may cause roof leaking
Suggested Action
Consult with a roofing professional for suggested improvement
Roof Material
Exterior: Roof View
Nearing the end of its useful life
Suggested Action
Budget for a newer unit. In the interim, a higher level of maintenance can be expected
12. Room Components
Descriptions
Cabinet
Cabinet Construction
Metal Brackets
Material
Laminate
Ceiling
Material
Drywall
Countertop
Material
Granite
Exterior door
Materials
Glass, Wood
Floor
Floor Cover
Carpet, Tile, Hardwood
Sub Floor Material
Plywood
Garage door opener
Manufacturer
Liftmaster
Type
Chain Drive
Interior Door
Materials
Metal
Style
Flush
Overhead Door
Material
Aluminum
Screen
Material
Vinyl
Stair
Rail Material
Iron, Wood
Stair Covering
Wood
Wall
Material
Drywall
Window
Window Frame Type
Vinyl
Window Glass Type
Double pane
Window Type
Casement
Attic Entry
Less than 22 x 30 inches
Impact
The smaller size makes access to the attic more difficult
Suggested Action
Enlarging the access should the size become an issue
Ceiling
Countertop
Exterior door
Exterior: Ground View
Does not open
Impact
A faulty exterior door removes a possible exit in case of an emergency
Suggested Action
Repair or replace the door depending on your preference
Delaminating
Impact
The delamination reduces the asthetic appeal of the door
Suggested Action
Replace the door
Other Information
Delamination is the loss of coating adhesion to a surface or between coating layers. Delamination tends to destroy the strength and durability of the coating, as well as the aesthetic appearance
Floor
Flooring was in good condition in general.
Suggested Action
I suggest cleaning/ replacing the carpets in the bedrooms prior to moving in.
Interior Door
Missing Tag
Impact
The door is self-closing and appears to be fire-rated, however, the tag is missing so it can not be determined if it is in fact, fire-rated
Suggested Action
Replace with fire-rated door
Overhead Door
Garage
Screen
Some missing Screens
Impact
Should the window be open, lacks protection from insects
Suggested Action
Consult with seller to identify if screens exist. If they do not, install screens as needed
Stair
Vanity
Bathroom
Wall
Drywall tape is delaminated
Impact
The delamination may continue requiring the drywall tape to be replaced
Suggested Action
Remove and retape the damaged areas
Photos