| Date: 3/30/2012 | Time: | Report ID: 33977staralane |
| Property: 33977 Stara Lane Hendersonville NC |
Customer: Danica Sample |
Real Estate Professional: Victor Tate Victor Realty |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Customer | Type of building: Single Family (1 story) | Approximate age of building: Under 5 Years |
Temperature: Over 65 | Weather: Cloudy | Ground/Soil surface condition: Dry |
Rain in last 3 days: Yes | Radon Test: Yes, No | Water Test: No |
Viewed roof covering from: Ground |
Roof-Type: Gable |
Roof Covering: 3-Tab fiberglass |
Chimney (exterior): Rock |
Sky Light(s): Three |
Roof Ventilation: Ridge vents Soffit Vents |
Method used to observe attic: Walked |
Roof Structure: Engineered wood trusses 2 X 12 Rafters Lateral bracing Sheathing |
Ceiling Structure: 2X6 |
Attic info: Pull Down stairs |
Attic Insulation: Blown Cellulose R-30 or better |
| IN | NI | NP | RR | ||
| 1.0 | Roof Coverings | • | |||
| 1.1 | Flashings | • | |||
| 1.2 | Skylights, Chimneys and Roof Penetrations | • | |||
| 1.3 | Roof Ventilation | • | |||
| 1.4 | Roof Drainage Systems (gutters and downspouts) | • | |||
| 1.5 | Roof Structure and Attic (Report leak signs or condensation) | • | |||
| 1.6 | Ventilation Fans and Thermostatic Controls (Attic) | • | |||
| 1.7 | Insulation in Attic | • | |||
| 1.8 | Visible Electric Wiring in Attic | • | |||
| IN | NI | NP | RR |
1.0 (1)
Evidence of a leak in the Den below corresponds with the middle skylight roof and flashing area.
Repairs are needed. Recommend a qualified contractor inspect further and repair as needed.
1.0 (2) The roof covering was installed improperly above
garage. Roof sheathing needs to be replaced in this
area. This will involve some shingle replacement. A
qualified contractor should inspect and repair as
needed.
1.4
The gutter screens are missing at the front of home above garage. Gutters that drain poorly or clogged can lead to
many costly problems such as deterioration of fascia, soffit or roof edge. It can also cause gutters to pull loose and
lead to possible water intrusion. A qualified person should repair or replace as needed.

Siding Style: RB&B (Reverse board and batten) Brick |
Siding Material: Wood Full brick |
Exterior Entry Doors: Steel Insulated glass |
Appurtenance: Covered porch Porch Sidewalk Patio |
Driveway: Asphalt |
| IN | NI | NP | RR | ||
| 2.0 | Wall Cladding, Flashing and Trim | • | |||
| 2.1 | Doors (Exterior) | • | |||
| 2.2 | Windows | • | |||
| 2.3 | Decks, Balconies, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings | • | |||
| 2.4 | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) | • | |||
| 2.5 | Eaves, Soffits and Fascias | • | |||
| 2.6 | Plumbing Water Faucets (hose bibs) | • | |||
| 2.7 | Outlets (Exterior) | • | |||
| 2.8 | Other | • | |||
| IN | NI | NP | RR |
2.0
The Wood siding at the right side (facing front) and
rear of home is missing or incomplete at time of
inspection around new premium windows that have
recently been installed. I did not inspect the
installation of siding at this location. A qualified
contractor should inspect and repair as needed.The
siding will need prep and paint.
2.4 (1) Possible water run-off from the street into driveway
during rain. I am unable to determine the frequency or
amount.
2.4 (2)
The brick walkway at the front of home are
deteriorated in areas. A general replacement is likely.
A qualified contractor should inspect and repair as
needed.

2.4 (4) The brick floor on the patio at the left side (facing
front) has deteriorated mortar or grout, and is loose
and uneven in areas. Water can cause further
deterioration if not repaired and sealed properly. A
qualified contractor should inspect and repair as
needed. 
2.4 (5) The brick floor on the patio at the rear of home is old
and deteriorated. A general replacement is likely. A
qualified contractor should inspect and repair as
needed.
2.5 (1)
The wood fascia and soffit panels at eave on the front
of home above garage are deteriorated. Repairs are
needed to roof covering as well. A qualified contractor
should inspect and repair as needed.
2.5 (2) The wood fascia at eave on the right side (facing front)
is deteriorated. This is a small repair. A qualified
contractor should inspect and repair as needed.

Garage Door Type: One automatic |
Garage Door Material: Insulated Metal |
| IN | NI | NP | RR | ||
| 3.0 | Garage Ceiling | • | |||
| 3.1 | Garage Walls (Including Firewall Separation) | • | |||
| 3.2 | Garage Floor | • | |||
| 3.3 | Garage Door (s) | • | |||
| 3.4 | Occupant Door from Garage to inside home | • | |||
| 3.5 | Garage Door Operators (Report whether or not doors will reverse when met with resistance) | • | |||
| IN | NI | NP | RR |
Dishwasher Brand: KENMORE |
Disposer Brand: IN SINK ERATOR |
Exhaust/Range hood: RE-CIRCULATE |
Range/Oven: GENERAL ELECTRIC |
Built in Microwave: KENMORE |
Cabinetry: Wood |
Countertop: Granite |
Clothes Dryer Vent Material: PVC Rigid |
Dryer Power Source: 220 Electric |
| IN | NI | NP | RR | ||
| 4.0 | Ceiling | • | |||
| 4.1 | Walls | • | |||
| 4.2 | Floor | • | |||
| 4.3 | Pantry/Closet Doors | • | |||
| 4.4 | Windows | • | |||
| 4.5 | Counters and a representative number of Cabinets | • | |||
| 4.6 | Plumbing Drain and Vent Systems | • | |||
| 4.7 | Plumbing Water Supply Faucets and Fixtures | • | |||
| 4.8 | Outlets Wall Switches and Fixtures | • | |||
| 4.9 | Dishwasher | • | |||
| 4.10 | Ranges/Ovens/Cooktops | • | |||
| 4.11 | Range Hood | • | |||
| 4.12 | Trash Compactor | • | |||
| 4.13 | Food Waste Disposer | • | |||
| 4.14 | Microwave Cooking Equipment | • | |||
| 4.15 | Clothes Dryer Vent Piping | • | |||
| IN | NI | NP | RR |
4.5
Base Cabinetry and trim at wall cabinet are unfinished
at kitchen.
4.9 The dishwasher is loose and needs securing to underside of countertop (using a proper length screw). I
recommend repair as necessary.
4.14 The microwave door handle is broken. I recommend
repair as needed.
Ceiling Materials: Drywall Suspended ceiling panels |
Wall Material: Drywall |
Floor Covering(s): Carpet Hardwood T&G Tile |
Interior Doors: Raised panel Wood |
Window Types: Casement Double-hung Thermal/Insulated Tilt feature |
Window Manufacturer: UNKNOWN |
| IN | NI | NP | RR | ||
| 5.0 | Ceilings | • | |||
| 5.1 | Walls | • | |||
| 5.2 | Floors | • | |||
| 5.3 | Steps, Stairways, Balconies and Railings | • | |||
| 5.4 | Doors (Representative number) | • | |||
| 5.5 | Windows (Representative number) | • | |||
| 5.6 | Outlets, Switches and Fixtures | • | |||
| IN | NI | NP | RR |
5.0 (1) The Sheetrock on the ceiling reveals a water stain indicating a leak did or still exists at the Den.
Repairs are needed. A qualified contractor should inspect and repair as needed (See Roof Coverings).
5.0 (2) Water stain on ceiling panel lower level indicates plumbing leak.
5.0 (3)
The Drywall on the ceiling reveals a water stain indicating a leak did or still exists at the Dining Room.
Repairs are needed. A qualified contractor should inspect and repair as needed.

5.1 (1)
Unfinished around windows in kitchen, and Den.
5.1 (2) The Wall at the bathtub is deteriorated and needs
repair or replacement. The wall board and framing
may need repair (not visible). I recommend repair or
replace using a qualified contractor.
5.1 (3) The sheetrock on the wall is dented or damaged from
door knob at the hallway. While this damage is
cosmetic, it needs to be repaired. A qualified
contractor should inspect and repair as needed.
5.1 (4) Stair cover trim is unfinished needs prep and paint at
stairs.
5.2 Carpet is loose or cut short from where electric
baseboard use to be in areas around the perimeter of
the Den.
Exhaust Fans: Fan/Heat/Light |
| IN | NI | NP | RR | ||
| 6.0 | Counters and Cabinets | • | |||
| 6.1 | Doors (Representative number) | • | |||
| 6.2 | Windows | • | |||
| 6.3 | Plumbing Drain, Waste and Vent Systems | • | |||
| 6.4 | Plumbing Water Supply and Distribution Systems and Fixtures | • | |||
| 6.5 | Outlets Switches and Fixtures | • | |||
| 6.6 | Exhaust fan | • | |||
| IN | NI | NP | RR |
Foundation: Masonry block |
Method used to observe Crawlspace: Limited access |
Floor Structure: 2 X 8 Wood joists Slab Engineered floor trusses |
Wall Structure: Masonry 2 X 4 Wood |
Columns or Piers: Steel lally columns Supporting walls |
Floor System Insulation: Unfaced Batts Fiberglass R-19 |
| IN | NI | NP | RR | ||
| 7.0 | Foundations, Basements and Crawlspaces (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | • | |||
| 7.1 | Walls (Structural) | • | |||
| 7.2 | Columns or Piers | • | |||
| 7.3 | Floors (Structural) | • | |||
| 7.4 | Ceilings (Structural) | • | |||
| 7.5 | Insulation under Floor System | • | |||
| 7.6 | Vapor Retarders (On ground in crawlspace or basement) | • | |||
| 7.7 | Ventilation of Foundation Area (crawlspace or basement) | • | |||
| IN | NI | NP | RR |
Water Source: Public |
Water Filters: None |
Plumbing Water Supply (into home): Copper |
Plumbing Water Distribution (inside home): Copper |
Washer Drain Size: 2" Diameter |
Plumbing Waste Line: PVC |
Water Heater Power Source: Electric |
Water Heater Capacity: 50 Gallon (2-3 people) |
Water Heater Manufacturer: A.O. SMITH |
Water Heater Location: Under Stairs |
| IN | NI | NP | RR | ||
| 8.0 | Plumbing Drain, Waste and Vent Systems | • | |||
| 8.1 | Plumbing Water Supply and Distribution Systems and Fixtures | • | |||
| 8.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents | • | |||
| 8.3 | Main Water Shut-off Device (Describe location) | • | |||
| 8.4 | Fuels Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks) | • | |||
| 8.5 | Main Fuel Shut-off (Describe Location) | • | |||
| 8.6 | Sump Pump | • | |||
| IN | NI | NP | RR |
Electrical Service Conductors: Overhead service 220 volts |
Panel capacity: 200 AMP |
Panel Type: Circuit breakers |
Electric Panel Manufacturer: GENERAL ELECTRIC |
Branch wire 15 and 20 AMP: Copper |
Wiring Methods: Romex |
| IN | NI | NP | RR | ||
| 9.0 | Service Entrance Conductors | • | |||
| 9.1 | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels | • | |||
| 9.2 | Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage | • | |||
| 9.3 | Connected Devices and Fixtures (A representative number of ceiling fans, lighting fixtures, switches, and receptacles inside the house, garage, and on the exterior walls) | • | |||
| 9.4 | Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, and all receptacles in garage and exterior walls of inspected structure | • | |||
| 9.5 | Operation of GFCI (Ground Fault Circuit Interrupters) | • | |||
| 9.6 | Location of Main and Distribution Panels | • | |||
| 9.7 | Smoke Detectors | • | |||
| 9.8 | Carbon Monoxide Detectors | • | |||
| IN | NI | NP | RR |
Heat Type: Heat Pump Forced Air (also provides cool air) |
Energy Source: Electric |
Number of Heat Systems (excluding wood): Two |
Heat System Brand: BRYANT |
Ductwork: Insulated |
Filter Type: Washable |
Types of Fireplaces: Conventional |
Operable Fireplaces: One |
Number of Woodstoves: None |
Cooling Equipment Type: Heat Pump Forced Air (also provides warm air) |
Cooling Equipment Energy Source: Electricity |
Central Air Manufacturer: BRYANT |
| IN | NI | NP | RR | ||
| 10.0 | Heating Equipment | • | |||
| 10.1 | Normal Operating Controls | • | |||
| 10.2 | Automatic Safety Controls | • | |||
| 10.3 | Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | • | |||
| 10.4 | Presence of installed Heat Source in each room | • | |||
| 10.5 | Chimneys, Flues and Vents (for fireplaces, gas water heaters, or heat systems) | • | |||
| 10.6 | Solid fuel heating devices (Fireplaces, Woodstove) | • | |||
| 10.7 | Gas/LP Firelogs and Fireplaces | • | |||
| 10.8 | Cooling and Air Handler Equipment | • | |||
| 10.9 | Normal Operating Equipment | • | |||
| 10.10 | Presence of installed Cooling Source in each room | • | |||
| IN | NI | NP | RR |
10.3
The washable filter is dirty. The filter needs to be cleaned. Recommend foil taping the filter for a better seal. See
Video. Foam sleeve missing at suction line creates condensation and drips water.


| 11.0 | This home is eligible for a one year Home Warranty offer! |

122 Lyman Street Building 1
Asheville, NC 28801
828-254-2030
Customer
Danica Sample
Address
33977 Stara Lane
Hendersonville NC
| 1. Roofing / Chimneys / Roof Structure and Attic | |||||||||||||||||||||
|
|||||||||||||||||||||
| 2. Exterior | |||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
| 4. Kitchen Components and Appliances | |||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 5. Rooms | ||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||
| 10. Heating / Central Air Conditioning | |||||||||
|
|||||||||