Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Age of Home: 31-40 Years | Inspection Type: Standard Home Inspection, Ancillary Service | Home Status: Vacant |
Weather: Clear | In Attendance: Buyers Agent, Inspector, Customer | Temperature: Below 65 (F) = 18 (C) |
Type of building: Single Family (1 story), Crawlspace, Single Family (1 story), Crawlspace | Termite: Yes |
|
Styles & Materials
Roof Description: Medium Slope Roof Covering/Type: 3-Tab fiberglass Estimated Age: 2-8 Years Design Life: 15 to 20 Years Inspection Method: Ladder at Eaves Binoculars from the Ground Location: Whole Roof Chimney (exterior): Brick |
|
Styles & Materials
Siding Style: Shiplap Brick Siding Material: Vinyl Brick veneer Porch: Masonry/Concrete Front Right Deck: Rear |
|
Styles & Materials
Walkway: Concrete Driveway: Concrete |
|
Styles & Materials
Description: Pull Down Stairs Inspection Method: Entered from Entry Framing: Wood Frame Trusses Sheathing: Structural Panels Insulation: Bat & Loose Limitations: Design Floored Areas Inaccessible Areas Tools Used for Inspection: Flashlight Camera Moisture Meter |
|
Styles & Materials
Ceiling Materials: Gypsum Board/Wood Wall Material: Gypsum Board/Wood Predominant Floors: Wood Window Types: Double-hung Double Pane Smoke Detectors: Battery & Hard Wired Detector Location: Halls & Bedrooms Fireplace: Gas Burner Wood Burning Vented Special Limitations: Appliances Finish Materials |
|
Styles & Materials
Location: Rear Ventilator: Recirculating Freestanding Range/Oven/Cook Top: 5-10 Years old Dishwasher: 5-10 Years old Disposal: 5-10 Years old Built In Microwave: 5-10 Years old Special Limitations: Appliances Finished Materials |
|
Styles & Materials
Description: Full Bath Location: Master Bedroom Ventilator: Window Exhaust Fan |
|
Styles & Materials
Description: Full Bath Location: Hallway Ventilator: Combo Light/Fan |
|
Styles & Materials
Electrical Service Conductors: Below ground Entrance Line: Not Determined Service Disconnect: Not Determined Major Appliances/240 volts: Not Determined Distribution Panel: Not Determined Household Circuits: Not Determined GFCI: At Receptacles Multiple Units Special Limitations: Panel Not Accessible |
|
Styles & Materials
System Type: Electric Air Conditioner System Make: Carrier System Location: Rear Estimated Age: 5-10 years Design Life: 8-12 Years General Distribution: Ducted/Register |
|
Styles & Materials
Water Piping: Pex Copper Water Source: Public Water Shut Off/Location: Foyer Closet Gas Shut Off/Location: Meter Plumbing Waste: PVC Special Limitations: Finsished Materials Main Water Line: Copper Front of Crawlspace |
|
Styles & Materials
Manufacturer: Not Determined Water Heater Location: Utility Room Water Heater Type: Not Determined Capacity: Not Determined Age: Not Determined Design Life: 8-12 years |
|
Styles & Materials
Crawlspace: Full House Crawlspace Inspection Method: Entered from Entry Foundation Walls/Piers: Block Brick House Floor Structure: Wood Frame Joist Insulation: Blanket Special Limitations: Insulation Moisture Barrier Tools Used for Inspection: Flashlight Camera Moisture Meter Screw Driver/Probe |
|
Styles & Materials
Description: crawlspace Sump Pump: Submersible Crawlspace Indications of Prior Remedial Work: Construction/Repairs Special Limitations: Moisture Barrier Insulation |
P.O. Box 5087
Lake Wylie, S.C. 29710
704-718-0043
Customer
Zack Page
Address
7419 Bent Oak Road
Charlotte NC 28226
1.1 | Chimneys/Vents | |
Inspected, Repair or Replace | ||
(1) Creosote observed on the chimney liner from the fireplace looking up, this is a potential safety concern for fires in the chimney area.
Recommend evaluation/correction by a qualified chimney sweep.
![]() 1.1 (Picture No.1)
|
||
(3) Chimney/fireplace clean out door at the rear chimney observed not closing properly, this is conducive to unwanted pests in the
interior space. Recommend evaluation/correction by a qualified contractor.
![]() 1.1 (Picture No.2)
|
1.3 | Ventilation Covers | |
Inspected, Repair or Replace | ||
Two soffit vents for what appears to be for the bathroom ventilators observed with the proper end cap, this is conducive to pest
intrusion of the ducts. Recommend evaluation/correction by a qualified contractor.
![]() 1.3 (Picture No.1)
|
1.5 | Gutters | |
Inspected, Repair or Replace | ||
(1) Gutter end at the rear left side observed damaged, this is conducive to water run over of the gutter end during rainy weather.
Recommend proper repair by a qualified contractor.
![]() 1.5 (Picture No.1)
|
||
(3) Gutters for all sides of house observed filled with debris and failing, this is conducive to the drainage system not able to function as
intended for carrying water away from the foundation/dwelling. Due to the severity of condition of the gutter system recommend
evaluation/correction by a qualified contractor for entire gutter system. (Pictures shown as examples of concern)
![]() 1.5 (Picture No.3)
![]() 1.5 (Picture No.4)
|
1.6 | Downspouts | |
Inspected, Repair or Replace | ||
In need of repair: Recommend adding downspout extensions for all downspouts to move water away from the dwelling to avoid
erosion at the foundation wall. (Pictures shown as examples of concern)
![]() 1.6 (Picture No.1)
![]() 1.6 (Picture No.2)
|
2.0 | Brick Veneer | |
Inspected, Repair or Replace | ||
(1) Horizontal/vertical cracking at the front left side that appears to be in need of further evaluation due to deflection of the cracking, this
wall is considered a curtain wall however further damage is the potential risk of inaction. It is recommend for further evaluation by a
qualified structural contractor.
![]() 2.0 (Picture No.1)
|
||
(3) Brick veneer observed not sealed at the front stoop and left front side of the dwelling, this is conducive to water intrusion of the
substructure. Recommend evaluation/correction by a qualified contractor. Also see the foundation/substructure elements for
comments/concerns.
![]() 2.0 (Picture No.4)
![]() 2.0 (Picture No.5)
|
||
(4) In need of repair: Two bricks on the top of brick area at right of front stoop/porch, this is conducive to a safety concern for dislodged
brick falling and water intrusion of the substructure.
![]() 2.0 (Picture No.6)
|
||
(5) Penetration not properly sealed observed at the front left side of the dwelling, this is conducive to pest intrusion of the crawlspace
environment.
![]() 2.0 (Picture No.7)
|
2.3 | Entry Doors | |
Inspected, Repair or Replace | ||
(1) In need of repair: The wood trim observed damage with missing paint at the rear door beside the fireplace. Further deterioration may
occur if not repaired. I recommend a qualified contractor inspect and repair as needed. (Picture shown as example of concern)
![]() 2.3 (Picture No.1)
|
||
(2) What appears to be wood destroying insect damage observed at the rear double/french door area at deck, this is conducive to further
decay of the component and substructure without proper repairs. Recommend evaluation/correction by a qualified contractor.
![]() 2.3 (Picture No.2)
|
2.4 | Stairs/Stoops | |
Inspected, Repair or Replace | ||
In need of repair: Cracked/missing mortar and or bricks for the front steps to the dwelling, and missing sealant at the right
stoop/slab. This is conducive to continued degradation of the stairs area especially during freeze/thaw cycles in the weather.
Recommend proper re-pointing as necessary. (Pictures shown as examples of concern)
![]() 2.4 (Picture No.1)
![]() 2.4 (Picture No.2)
![]() 2.4 (Picture No.3)
|
2.6 | Deck | |
Inspected, Repair or Replace | ||
(1) Deck framing at the right side observed without the proper double ledger board at the joist attachment area, this has potential for
fatigue/failure of the support system in this area and does not meet the current standard. Recommend evaluation/correction by a
qualified contractor.
![]() 2.6 (Picture No.1)
|
||
(2) Main beam for center support of the rear deck observed as a 2x4, this size wood member is not capable of the proper support
needed for mid span 2x8 decking joists, recommend further evaluation/correction by a qualified contractor.
![]() 2.6 (Picture No.2)
|
||
(3) Ledger board at the foundation for joist attachment observed what appears to be toe nail method of attachment, this is conducive to
fatigue/failure of the component over time. Recommend proper attachment of through bolts with washers and nut. Recommend
evaluation/correction by a qualified contractor.
![]() 2.6 (Picture No.3)
|
5.4 | Doors | |
Inspected, Repair or Replace | ||
In need or repair: Top of door ball mechanism observed damaged/missing for linen closet entrance in hall. This is conducive to the
door not able to function/close or latch as originally intended. Recommend replacement of component.
![]() 5.4 (Picture No.1)
|
5.5 | Detector Test | |
Inspected, Repair or Replace | ||
In need of repair: Detectors for several areas observed "chirping" which is conducive to the battery in need of changing and
component has potential for failure, battery observed missing for the unit in front center bedroom. Recommend changing batteries
when needed or annually. (Picture shown as example and unit with missing battery)
![]() 5.5 (Picture No.1)
![]() 5.5 (Picture No.2)
|
5.6 | Fireplace | |
Inspected, Repair or Replace | ||
In need of repair: Hearth observed with some cracking in the brick, this is a potential safety concern and should be properly
patched/repaired.
![]() 5.6 (Picture No.1)
|
5.7 | Fireplace Gas Burner | |
Inspected, Repair or Replace | ||
Gas burner could not be evaluated as the natural gas service provider has tagged the unit as unsafe. Recommend further
evaluation/correction by a qualified natural gas contractor.
![]() 5.7 (Picture No.1)
![]() 5.7 (Picture No.2)
|
6.0 | Sink | |
Inspected, Repair or Replace | ||
(1) In need or repair: Missing/cracked caulking at sink to counter top area, this is conducive to water intrusion of the cabinet area.
![]() 6.0 (Picture No.1)
|
6.2 | Range | |
Inspected, Repair or Replace | ||
(1) In need of repair: No anti-tilt bracket observed installed for the range. This is a safety device recommended by the CPSC ( Consumer
Product Safety Commission) for safety. Condition without bracket poses a safety concern for range tilting forward with added weight
placed on door when open.
|
6.8 | Counter Top | |
Inspected, Repair or Replace | ||
In need of repair: Counter top observed loose at the left side of the range, this does not allow the component to function as intended.
![]() 6.8 (Picture No.1)
|
6.9 | Dryer Vent | |
Inspected, Repair or Replace | ||
Dryer vent duct observed damaged in the crawlspace at the right rear area, this is conducive to the intrusion of moist air into the
crawlspace environment and fungal like growth. Recommend evaluation/correction by a qualified contractor.
![]() 6.9 (Picture No.1)
|
7.0.A | Sink | |
Inspected, Repair or Replace | ||
In need of repair: Faucet assembly observed loose at the vanity top, this is conducive to damage of the plumbing components
below the vanity and water intrusion of the cabinet.
![]() 7.0.A (Picture No.1)
|
7.2.A | Bathtub | |
Inspected, Repair or Replace | ||
(1) In need of repair: Cracked/missing caulking observed at the tub/surround, faucet/surround and in various areas of wall tile, this is
conducive to water intrusion of the substructure. (Pictures shown as examples of concern)
![]() 7.2.A (Picture No.1)
![]() 7.2.A (Picture No.2)
![]() 7.2.A (Picture No.3)
|
||
(2) Diverter observed not allowing the full flow of water to the shower head from the faucet when engaged, this does not allow the
component to function as intended and weaker stream of water at the shower head. Recommend evaluation/correction by a qualified
plumbing contractor. (Picture shown with diverter engaged)
![]() 7.2.A (Picture No.4)
|
7.0.B | Sink | |
Inspected, Repair or Replace | ||
(1) Hot/cold water observed reversed at the shower controller, this is a safety concern for personal injury as the hot water is always
considered to be on the left side. Recommend evaluation/correction by a qualified plumbing contractor.
![]() 7.0.B (Picture No.1)
|
7.2.B | Bathtub | |
Inspected, Repair or Replace | ||
(1) Hot/cold water observed reversed at the shower controller, this is a safety concern for personal injury as the hot water is always
considered to be on the left side. Recommend evaluation/correction by a qualified plumbing contractor.
![]() 7.2.B (Picture No.1)
|
||
(3) In need of repair: Cracked/missing caulking observed at the faucet/surround, this is conducive to water intrusion of the substructure.
![]() 7.2.B (Picture No.2)
|
||
(4) In need of repair: Cracked/missing caulking observed at the tub/surround in various areas, this is conducive to water intrusion of the
substructure. (Picture shown as example of concern)
![]() 7.2.B (Picture No.3)
|
7.3.B | Ventilation | |
Inspected, Repair or Replace | ||
Ventilator appears to be functioning as intended for areas visible at time of inspection for areas visible to inspection.
|
8.4 | Devices | |
Inspected, Repair or Replace | ||
Light fixtures observed for various areas throughout the house observed not engaging with light switches, hall bath vent light, eat in
kitchen area, living room, foyer. This is conducive to the components not functioning as intended which may potentially be a light
bulb, however if the component still does not function with a bulb chain it is recommended for further evaluation by a qualified
electrical contractor.
![]() 8.4 (Picture No.1)
|
8.5 | Wiring | |
Inspected, Repair or Replace | ||
(1) Electrical wiring in the crawlspace observed not properly suspended from the substructure and lying on the ground, this is a potential
safety concern for damage of the wiring. Recommend evaluation/correction by a qualified contractor.
![]() 8.5 (Picture No.1)
|
||
(2) Exposed electrical wiring observed in the Crawlspace on the rear left side/in need of a cover plate, this is a potential safety concern
for personal injury from damage to the electrical component. Recommend evaluation/correction by aa qualified electrical contractor.
![]() 8.5 (Picture No.2)
|
9.1 | Outdoor Unit | |
Inspected, Repair or Replace | ||
(1) Cooling fins for the outside unit observed dirty, this is conducive to affecting the proper performance of the system and suggests that
system has not been maintained recently. Recommend evaluation/correction by a qualified HVAC contractor.
![]() 9.1 (Picture No.1)
|
||
(2) In need or repair: Insulation on line set in the crawlspace area of line observed damaged/missing, this is conducive to a loss of
insulating factor and affecting the efficiency of the system.
![]() 9.1 (Picture No.2)
|
9.4 | Distribution System | |
Inspected, Repair or Replace | ||
(1) In need of repair: No filter observed in the return for the HVAC system in the hall area and no whole house filtration noted at the air
handler, this does not allow the system to function as intended for properly conditioning the air, recommend the proper filter be
placed at the return in the entrance of the unit.
![]() 9.4 (Picture No.1)
|
||
(2) In need of repair: Dirty filters observed in living room return, this is conducive to affecting the proper performance of the HVAC
system. Recommend changing filters monthly. (Picture shown as example of concern)
![]() 9.4 (Picture No.2)
|
10.3 | Drain/Waste Vent Piping | |
Inspected, Repair or Replace | ||
(2) Wastewater piping clean out at the front left side of dwelling observed not capped, this is conducive to debris/pests in the drain piping
and potential clogging of the component. Recommend evaluation/correction by a qualified plumbing contractor.
![]() 10.3 (Picture No.1)
![]() 10.3 (Picture No.2)
|
12.0 | Foundation Walls | |
Inspected, Repair or Replace | ||
(1) In need of repair: Vegetation observed in contact with the foundation wall in various with large roots noted in foundation wall areas,
this is conducive to water retention at the wall and wood destroying insects. Recommend the standard of 2 feet between dwelling and
any vegetation.
![]() 12.0 (Picture No.1)
![]() 12.0 (Picture No.2)
![]() 12.0 (Picture No.3)
![]() 12.0 (Picture No.4)
|
||
(2) In need of repair: Penetrations in the foundation wall observed at the rear HVAC line set entrance to the dwelling and the front center
area not properly sealed, this is conducive to unwanted pests in the crawlspace. (Pictures shown as examples of concern)
![]() 12.0 (Picture No.5)
![]() 12.0 (Picture No.6)
|
12.3 | Main Beams | |
Inspected, Repair or Replace | ||
(1) What appears to be an exposed area of sill beam at the rear left side of deck, this is conducive to decay of the component.
Recommend evaluation/correction by a qualified contractor.
![]() 12.3 (Picture No.1)
|
||
(2) Water intrusion with damage to the sill beam observed at the front right side of the front stoop and rear right corner to the french door
area in the crawlspace, this is conducive to continued degradation of the substructure without proper repairs. Recommend
evaluation/correction by a qualified contractor. Note: Below 16% is an acceptable reading
![]() 12.3 (Picture No.2)
![]() 12.3 (Picture No.3)
![]() 12.3 (Picture No.4)
![]() 12.3 (Picture No.5)
![]() 12.3 (Picture No.6)
|
||
(4) Beam at the rear left side of substructure under bathroom observed cut for plumbing entrance and not properly re-braced, this is
conducive to fatigue/failure of the component to function as originally intended. Recommend evaluation/correction by a qualified
contractor.
![]() 12.3 (Picture No.8)
|
12.4 | Crawlspce Ventilation | |
Inspected, Repair or Replace | ||
(1) In need of repair: Foundation vents observed in various areas without the proper screening installed in the vent, this is conducive to
unwanted pest intrusion of the crawlspace environment. (Picture shown as example of concern)
![]() 12.4 (Picture No.1)
|
||
(2) Foundation vent at the center right side observed in area of allowing water intrusion into the crawlspace environment, elevated
moisture/standing water observed in the crawlspace in this area with evidence of prior wood destroying insects. Recommend
evaluation/correction by a qualified contractor.
![]() 12.4 (Picture No.2)
![]() 12.4 (Picture No.3)
![]() 12.4 (Picture No.4)
|
12.6 | Crawlspace Access | |
Inspected, Repair or Replace | ||
In need of repair: Rot/decay noted at bottom of the crawlspace entry door, this is conducive to continued degradation of the
component without proper repairs.
![]() 12.6 (Picture No.1)
|
13.1 | Sump Pump | |
Inspected, Repair or Replace | ||
(1) Sump pump observed in the crawlspace at the left front improperly installed without covering for sump, this is conducive to debris in
the sump area disrupting the proper function of the system. Recommend evaluation/correction by a qualified contractor.
![]() 13.1 (Picture No.1)
|
||
(2) Sump pump observed plugged into a long extension cord laying on the crawlspace floor extending across the crawlspace, this is a
safety concern with potential of failure of the system. The standard is for the component to plugged into a GFCI outlet at the unit.
Recommend evaluation/correction by a qualified electrical contractor
![]() 13.1 (Picture No.2)
![]() 13.1 (Picture No.3)
|
![]() |
INVOICE |
GalcovLLC
P.O. Box 5087 Lake Wylie, S.C. 29710 704-718-0043 Inspected By: John Galop |
Inspection Date: 12/1/2016
Report ID: 1612JG72Page |
Customer Info: | Inspection Property: |
Zack Page
Customer's Real Estate Professional: |
7419 Bent Oak Road Charlotte NC 28226 |
| ||||||||||||
Tax $0.00 | ||||||||||||
Total Price $350.00 |
Payment Method: Check
Payment Status: Check is in the mail
Note: Check Number 102
![]() GalcovLLC
P.O. Box 5087 |
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.