Date: 11/18/2016 | Time: 09:00 AM | Report ID: Homebuyer 20161118 Sample |
Property: 1000 Our Town Way Virginia Beach VA |
Customer: Joe Homebuyer |
Real Estate Professional: Tom Agent Best Realty Around Town |
THIS REPORT IS THE PROPERTY OF KEN MELTON HOME INSPECTIONS AND THE CLIENT(S) AND IS VALID FOR THE DATE OF THE INSPECTION ONLY. COPIES OF THIS INSPECTION REPORT ARE DISTRIBUTED TO OTHER PARTIES AS A COURTESY AND SHALL NOT BE USED FOR ANY FUTURE TRANSACTIONS ON THIS PROPERTY.
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Client(s) Present: Yes | Building Type: Single Family | Age Of Home: Reported to be built in 1970 |
Square Footage: 2577 | Inspection Type: Buyer's | Temperature (degrees farenheit): 65 |
Occupancy: Vacant | Weather: Clear |
FOUNDATION: PIER AND BEAM STYLE FOUNDATION MASONRY BLOCK FOUNDATION WALL MASONRY BLOCK PIERS |
CRAWL SPACE ENTRANCE: EXTERIOR REAR |
FLOOR STRUCTURE: WOOD JOISTS WOOD BEAMS PLYWOOD SUBFLOOR |
WALL STRUCTURE: WOOD FRAMING 2 X 4 WALL STUDS |
ROOF STRUCTURE: ENGINERED WOOD TRUSSES PLYWOOD SHEATHING |
MOISTURE CONTROL MEASURES / CONDITIONS: VAPOR BARRIER |
CRAWL SPACE / BASEMENT VENTILATION: PASSIVE |
FLOORING INSULATION: FIBERGLASS BATTS R-13 |
ROOF INSPECTION BY:: WALKED ROOF |
ROOF COVERING TYPE(S): ARCHITECTURAL COMPOSITION SHINGLE LIKE NEW |
ATTIC VENTILATION: PASSIVE VENTS THERMOSTATICALLY CONTROLLED FAN(S) |
ATTIC INSULATION: FIBERGLASS BATT FIBERGLASS LOOSE FILL VARYING LEVELS FROM: 0" 12" |
ROOF DRAINAGE: GUTTERS AND DOWNSPOUTS SPLASHBLOCKS |
ELECTRICAL SERVICE CONDUCTORS: OVERHEAD SERVICE ALUMINUM 220 VOLTS |
MAIN ELECTRICAL DISCONNECT: 200 AMP CIRCUIT BREAKER IN MAIN PANEL BOX |
MAIN ELECTRICAL PANEL: 200 AMP CIRCUIT BREAKERS GARAGE |
BRANCH WIRE 15 and 20 AMP: ALUMINUM (see additional comments in this report) |
WIRING METHODS: NM (non-metallic sheathing) Grounded |
OUTLET TYPES: 3 PRONG (Hot,Neutral, & Ground) |
GFCI PROTECTED AREAS: BATHS GARAGE OUTSIDE SEE COMMENTS CHECK MONTHLY |
AFCI PROTECTION: AFCI BREAKERS WERE NOT REQUIRED AT TIME OF CONSTRUCTION |
There is also a test button next to the reset button, which shows that the GFCI works properly. GFCI outlets should be tested at least once a month.
WATER SUPPLY SOURCE: PUBLIC (City) |
WATER METER TEST: SATISFACTORY |
MAIN WATER SHUT-OFF LOCATION(S): YARD |
HOSE BIB SHUT-OFF LOCATION(S): KITCHEN CABINET FOYER CLOSET |
PLUMBING SUPPLY: COPPER |
EXPOSED PLUMBING DISTRIBUTION: COPPER |
EXPOSED PLUMBING WASTE SYSTEM: PVC |
EXPOSED PLUMBING WASTE VENT SYSTEM: PVC |
WASHING MACHINE DRAIN: 2" PVC |
FUEL SOURCE (other than electric): PUBLIC NATURAL GAS |
FUEL SHUT OFF VALVES: GAS METER AT EACH PIECE OF EQUIPMENT |
WATER HEATER 1 GENERAL INFO: LAUNDRY ELECTRIC 50 GALLON |
WATER HEATER 1 MANUFACTURE DATE: 2014 |
SECTION P3003
JOINTS AND CONNECTIONS
P3003.2 Prohibited joints. Running threads and bands shall
not be used in the drainage system. Drainage and vent piping
shall not be drilled, tapped, burned or welded.
5. Solvent-cement joints between different types of plastic
pipe.
HEATING TYPE: NATURAL GAS FORCED AIR FURNACE |
VENTING: METAL FLUE PIPE TO EXTERIOR |
ZONE(S): WHOLE HOUSE |
UNIT AGE: BEYOND EXPECTED SERVICE LIFE >20 YEARS OLD - SEE BELOW Extra Info : Manufactured in 1980 |
CAPACITY: 100,000 BTU INPUT |
DISTRIBUTION: DUCTWORK AND REGISTERS INSULATED |
THERMOSTAT LOCATION: DOWNSTAIRS HALL |
FILTER LOCATIONS / SIZES: UPSTAIRS DOWNSTAIRS 16" x 20" 20" x 20" |
SYSTEM TYPE: CENTRAL AIR CONDTIONER POWER SOURCE - ELECTRIC |
ZONE(S): WHOLE HOUSE |
OUTDOOR UNIT AGE: 10 YEARS OLD TYPICAL SERVICE IS 15 YEARS |
OUTDOOR UNIT SIZE: 4 TON |
INDOOR UNIT AGE: 10 YEARS OLD |
INDOOR UNIT SIZE: 4 TON |
THERMOSTAT LOCATION: SHARED WITH HEATING SYSTEM |
DISTRIBUTION: DUCTWORK AND REGISTERS |
FILTER LOCATION(S): SHARED WITH HEATING SYSTEM |
The home inspector shall observe chimneys, flues, and vents, where readily visible and solid fuel heating devices. The home inspector shall describe: Energy source; and equipment type. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections.
FIREPLACE / SOLID FUEL BURNING DEVICE TYPE: CONVENTIONAL MASONRY WOODSTOVE INSERT |
FUEL TYPES: SOLID FUEL (ex. WOOD) |
CHIMNEY (interior): FLUE NOT VISIBLE - WOODSTOVE INSTALLED |
CHIMNEY (exterior): BRICK CEMENT CROWN |
SIDING MATERIAL: VINYL SIDING |
ATTACHED EXTERIOR STRUCTURES: PORCH(ES) |
DRIVEWAYS: CONCRETE TYPICAL CRACKS |
WALKWAYS: CONCRETE |
LIMITATIONS TO INSPECTION OF THE INTERIOR: NONE - HOUSE IS VACANT |
WINDOWS: VINYL REPLACEMENT WINDOWS |
BATHROOM VENTILATION: FANS |
LAUNDRY VENTILATION: VENTS OUTSIDE |
SMOKE DETECTOR LOCATIONS: DOWNSTAIRS UPSTAIRS ALL BEDROOMS HARD WIRED - ALL WILL SOUND WHEN ONLY ONE IS ACTIVATED CHECK SMOKE DETECTORS MONTHLY CHANGE BATTERIES ANNUALLY |
CARBON MONOXIDE DETECTOR LOCATIONS: DOWNSTAIRS SEE COMMENTS CHECK CARBON MONOXIDE DETECTORS MONTHLY CHANGE BATTERIES ANNUALLY |
RANGES / OVENS / COOKTOPS: RANGE - GAS NEW NOT SECURED BY ANTI-TIP BRACKETS |
KITCHEN VENTILATION: PART OF OVER THE RANGE MICROWAVE VENTS OUTSIDE |
DISHWASHER: BUILT-IN |
FOOD WASTE DISPOSAL: CONTINUOUS FEED OLD |
MICROWAVE: OVER THE RANGE |
REFRIGERATOR-CHILLERS: REFRIGERATOR WITH ICE MAKER |
DRYER POWER SOURCE: ELECTRIC 3 PRONG OUTLET |