In order to assist you, we have divided the summary into four broad categories:
Tier 1 Items are items that we believe are abnormally hazardous safety items, or are likely to be expensive to repair.
Tier 2 Items consist of moderate concerns or expenses in our opinion. They usually require a contractor or an experienced handyman.
Tier 3 are the "low end" items that are often corrected by home owners or a handyman. These are minor repairs or maintenance. Though "low end", failure to address theses issues can lead to larger issues. The consequences of deferred maintenance over time can negatively effect your investment.
For Your Information. These are items that are provided for your information. Typically these items discuss how things work, items for your awareness in the normal operation of systems, or items that we normally inspect but could not during this inspection.
8.3 | Steps, Stairways, Balconies and Railings |
Repair or Replace | |
Based on the Inspector's past experience, the handrail assembly did not appear to be of adequate strength to safely protect the staircase. Physical testing for compliance with any building standards or building codes lies beyond the scope of the General Home Inspection. The Inspector recommends that additional support be installed by a qualified contractor. ![]() 8.3 Item 1(Picture)
![]() ![]() 8.3 Item 2(Video)
|
1.0 | Roof Coverings |
Repair or Replace | |
The roof has areas of either damaged, missing, or torn shingles. Recommend having a roofing contractor evaluate and repair, or replace these areas to ensure a watertight roofing system. ![]() 1.0 Item 1(Picture)
![]() 1.0 Item 2(Picture)
![]() 1.0 Item 3(Picture)
|
2.0 | Wall Cladding Flashing and Trim |
Repair or Replace | |
(1) There is some minor exterior wood rot at areas such as the bases of doors, garage vehicle entrances, or windows. Recommend a handyman remove affected wood and inspect for framing damage, replace with a new section
of wood painted on all six sides, and caulk the seams to prevent water intrusion/damage (Examples are pictured for reference). ![]() 2.0 Item 1(Picture)
![]() 2.0 Item 2(Picture)
|
2.2 | Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings |
Repair or Replace | |
(1) There is an area of the front porch which appears to have some minor settling type cracks. Recommend a qualified contractor evaluate this area and at a minimum have it sealed and tuck pointed to prevent further
deterioration from moisture intrusion. ![]() 2.2 Item 1(Picture)
|
5.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents |
Inspected | |
The potable expansion tank has a ruptured diaphragm inside that has allowed the tank to fill with water and escape from the schrader valve when tested. This tank protects the TPR valve and other pluming components from thermal expansion. Recommend having a plumber replace for proper function. ![]() 5.2 Item 1(Picture)
|
5.4 | Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks) |
Repair or Replace | |
The gas piping system contains flexible CSST type gas lines which are not bonded and grounded. Manufacturers believe that this product is safer if properly bonded and grounded as required by the manufacturer's installation
instructions. We recommend a licensed electrician bond the gas piping system to the electrical service grounding electrode system using a minimum of 6 AWG copper wiring (or equivalent) to limit your risk of gas
leaks/fires/explosions from lightning strikes (See GASTITE Technical Bulletin #TB2014-01). ![]() 5.4 Item 1(Picture)
|
6.0 | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels |
Inspected | |
At the basement sub panel, some labels are present, but are illegible or confusing. Recommend a qualified electrician trace the circuits and label properly for safety reasons. ![]() 6.0 Item 1(Picture)
|
6.7 | Smoke Detectors (test button test, adequate in number and location). Were any ionization type detectors? |
Repair or Replace | |
(2) The 2nd floor hallway smoke detector did not sound an audible alarm when tested. Recommend replacement for fire safety. ![]() 6.7 Item 1(Picture)
|
1.3 | Roof Drainage Systems |
Repair or Replace | |
At the rear of the home there is a downspout which discharges onto the roof surface. This area will wear more than other areas because of the additional water flow over the roof surface. Recommend a handyman reroute this
downspout to the existing gutter to prolong the life of the roof. ![]() 1.3 Item 1(Picture)
|
2.0 | Wall Cladding Flashing and Trim |
Repair or Replace | |
(2) There are minor openings in the siding/trim/brick that should be sealed (Some Examples are pictured). You should plan on detecting, caulking, and sealing openings annually to protect your investment. ![]() 2.0 Item 3(Picture)
![]() 2.0 Item 4(Picture)
|
2.2 | Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings |
Repair or Replace | |
(2) Recommend power wash and seal the decks to preserve and limit weather damage. ![]() 2.2 Item 2(Picture)
|
2.3 | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) |
Repair or Replace | |
(1) Clear shrubs at least 6 inches (preferably 18 inches) from the foundation to allow air flow to encourage evaporation of moisture against the foundation. ![]() 2.3 Item 1(Picture)
|
|
(2) Examples of common cracks in areas such as driveways, the seams between driveways, walkways, garage aprons, and the seams between driveways/patios and the house foundation need to be sealed with an appropriate sealant. Recommend a handyman seal these to limit water intrusion (water intrusion can increase cracking and cause the driveway to settle or cause hydrostatic pressures against the foundation in areas close to the foundation). ![]() 2.3 Item 2(Picture)
|
2.6 | Fences and Gates |
Repair or Replace | |
There is an area of the fence where there are multiple loose boards. Recommend a handyman reattach the boards for proper function ![]() 2.6 Item 1(Picture)
|
3.0 | Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) |
Inspected | |
There are common vertical cracks in the foundation. Recommend seal with concrete compatible caulk to limit water intrusion (water intrusion can make the cracks larger over time). ![]() 3.0 Item 1(Picture)
![]() 3.0 Item 2(Picture)
|
8.5 | Doors (where accessible) |
Repair or Replace | |
The door to the foyer closet rubs, and is difficult to latch. This can be an indication of the home settling over time, but we did not find other significant symptoms of a problem. Recommend a handyman adjust the door for proper operation. ![]() ![]() 8.5 Item 1(Video)
|
8.7 | Bathrooms |
Repair or Replace | |
You should regularly check for even the smallest openings and when necessary re-seal the corner seams of shower and bath walls, where showers and tubs meet the floor and walls, where bath/shower plumbing fixtures meet the wall, any openings in the grout of shower and tub tiled walls, any openings in the grout of tiled bathroom floors, and the seam between the sink counter and back splash. Currently there is minor caulking needed (examples pictured). While moisture intrusion and hidden water damage is possible, we pressed and pounded on the subfloor and walls in these areas and they appear solid. ![]() 8.7 Item 1(Picture)
![]() 8.7 Item 2(Picture)
|
11.0 | Were all interior rooms and garage fully accessible (including clear of furniture and rugs)? |
No | |
The unfinished basement storage area was not fully accessible at the time of the inspection. Recommend this/these be made accessible and inspected at your final walkthrough prior to settlement to ensure no repairs are necessary. ![]() 11.0 Item 1(Picture)
![]() 11.0 Item 2(Picture)
|
4.9 | A/C Differential Temperature |
Inspected | |
We measured the differential temperature between the supply and return side of the air conditioner evaporator (inside unit) using the Target Temperature Split method. This method includes return wet and dry bulb temperature measurements to produce a target temperature split consistent with the in door humidity levels. The system was within the standard expected range. |
5.3 | Main Water Shut-off Device (Describe location) |
Inspected | |
(1) The main water shut off valve is located in the basement, the water heater and hose bibs. ![]() 5.3 Item 1(Picture)
|
|
(2) The exterior hose faucet shut off valves are located in the basement near the water heater. ![]() 5.3 Item 2(Picture)
|
5.5 | Sump Pump |
Inspected | |
The sump pump lid is sealed shut and as a result we were unable to access the pump and float to test for function today. ![]() 5.5 Item 1(Picture)
|
6.7 | Smoke Detectors (test button test, adequate in number and location). Were any ionization type detectors? |
Repair or Replace | |
(1) The smoke detectors present within the home were tested using the test button. While this provides a test of the audible alert function of the detector, it does ensure that the detector will sound the alarm in the presence of smoke from an actual fire. There are presently two types of technologies available for smoke detectors, ionization and photoelectric. Studies have shown that each have advantages in rapid detection of common house fires. Accordingly, the National Fire Protection Association (NFPA) presently recommends using both types in the home. Additional information can be found at https://www.nfpa.org. |
8.0 | Ceilings |
Inspected | |
The Sheetrock on the ceiling has several hairline cracks (cosmetic). This damage is considered cosmetic. ![]() 8.0 Item 1(Picture)
|
8.1 | Walls |
Inspected | |
There are common cracks in the drywall walls. This appears cosmetic, but recommend monitor. ![]() 8.1 Item 1(Picture)
|
8.2 | Floors |
Inspected | |
In the basement the concrete floor has been stained sealed and Polished. There is a filled crack near the bar area. This appears to be stable and not of structural concern. ![]() 8.2 Item 1(Picture)
|
Date: 4/6/2018 | Time: | Report ID: 180406-1 |
Property: 7 Homeowner Way Fredericksburg VA 22407 |
Customer: Mr. Harry Homebuyer |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Customer and their agent | Type of building: Single Family (2 story) | Approximate age of building: 10 Years old |
Temperature: Over 65 (F) | Weather: Cloudy | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Radon Test: No | Water Test: No |
Roof Covering: Architectural |
Viewed roof covering from: Walked roof |
Sky Light(s): None |
Chimney (exterior): N/A |
Roof Ventillation: Soffit and Ridge Vents Power Ventillator |
IN | NI | NP | RR | ||
1.0 | Roof Coverings | • | |||
1.1 | Flashings | • | |||
1.2 | Skylights, Chimneys and Roof Penetrations | • | |||
1.3 | Roof Drainage Systems | • | |||
1.4 | Roof Ventillation (Soffits, Ridge, Gable) | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Siding Material: Vinyl Brick veneer Stone |
Exterior Entry Doors: Fiberglass Sliding Glass |
Driveway: Concrete |
Exterior Steps: Wood Concrete Brick |
IN | NI | NP | RR | ||
2.0 | Wall Cladding Flashing and Trim | • | |||
2.1 | Doors (Exterior) | • | |||
2.2 | Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings | • | |||
2.3 | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) | • | |||
2.4 | Eaves, Soffits and Fascias | • | |||
2.5 | Additional Buildings on Property | • | |||
2.6 | Fences and Gates | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Foundation: Poured concrete |
Method used to observe Crawlspace: No crawlspace |
Floor Structure: Engineered floor joists |
Columns or Piers: Steel lally columns |
Basement/Crawlspace Ceiling Structure: Engineered Floor Joist |
Roof Structure: 2 X 6 Rafters |
Roof-Type: Gable Hip |
Method used to observe attic: Walked |
Attic info: Attic access Light in attic |
Basement/Crawlspace Floor Type: Concrete Slab |
IN | NI | NP | RR | ||
3.0 | Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | • | |||
3.1 | Walls (Structural) | • | |||
3.2 | Columns or Piers | • | |||
3.3 | Floors (Structural) | • | |||
3.4 | Ceilings (Structural) | • | |||
3.5 | Roof Structure and Attic | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Heat Type: Forced Air |
Energy Source: Gas |
# of Heat Systems (excluding wood)/# of zones: Two/Two |
Ductwork: Partially insulated |
Filter Type: Disposable |
Filter Size: 18x18 |
Types of Fireplaces: Vented gas logs |
Operable Fireplaces: One |
Number of Woodstoves: None |
Cooling Equipment Type: Air conditioner unit |
Cooling Equipment Energy Source: Electricity |
Number of AC Only Units: Two |
IN | NI | NP | RR | ||
4.0 | Heating, Cooling, and Air Handler Equipment (all openable access panels were opened) | • | |||
4.1 | Normal Operating Controls (Heating and cooling) | • | |||
4.2 | Auxiliary (Emergency) Heat | • | |||
4.3 | Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | • | |||
4.4 | Presence of Installed Heat and Cooling Source in Each Room | • | |||
4.5 | Chimneys, Flues and Vents (for fireplaces, gas water heaters or heat systems) | • | |||
4.6 | Solid Fuel Heating Devices (Fireplaces, Woodstove) | • | |||
4.7 | Gas/LP Firelogs and Fireplaces | • | |||
4.8 | Fireplace/woodstove blowers present and operated normally | • | |||
4.9 | A/C Differential Temperature | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Water Source: Public |
Water Filters: None |
Plumbing Water Supply (into home): Black hose |
Plumbing Water Distribution (inside home): CPVC |
Plumbing Waste: PVC |
Interior Plumbing Venting: PVC |
Water Heater Power Source: Gas (quick recovery) |
Water Heater Capacity: 50 Gallon (2-3 people) |
Water Heater Location: Basement Utility Room |
Gas/Oil/Propane Isolation Valve Location: Exterior Left Side |
IN | NI | NP | RR | ||
5.0 | Plumbing Drain, Waste and Vent Systems | • | |||
5.1 | Plumbing Water Supply, Distribution System and Fixtures | • | |||
5.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents | • | |||
5.3 | Main Water Shut-off Device (Describe location) | • | |||
5.4 | Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks) | • | |||
5.5 | Sump Pump | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Electrical Service Conductors: Below ground 220 volts |
Service capacity: 200 AMP |
Panel Type: Circuit breakers |
Branch wire 15 and 20 AMP: Copper |
Wiring Methods (Predominant): Romex |
Location of Main Panel: Basement |
Location of Sub Panel (s): Basement |
Dryer Power Source: 220 Electric Gas Connection |
IN | NI | NP | RR | ||
6.0 | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels | • | |||
6.1 | Service Entrance Conductors | • | |||
6.2 | Branch Circuit Conductors, Overcurrent Fuses and/or Breakers, and Compatability of their Amperage and Voltage | • | |||
6.3 | Test of AFCI (Arc Fault Circuit Interrupters) in Panel | • | |||
6.4 | Switches, installed lighting fixtures/fans, and receptacles (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | • | |||
6.5 | Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure | • | |||
6.6 | Operation of GFCI (Ground Fault Circuit Interrupters) | • | |||
6.7 | Smoke Detectors (test button test, adequate in number and location). Were any ionization type detectors? | • | |||
6.8 | Carbon Monoxide Detectors | • | |||
6.9 | Dryer Outlet operational | • | |||
6.10 | Washing Machine Outlet Grounded | • | |||
6.11 | Doorbell | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
There are presently two types of technologies available for smoke detectors, ionization and photoelectric. Studies have shown that each have advantages in rapid detection of common house fires. Accordingly, the National Fire Protection Association (NFPA) presently recommends using both types in the home. Additional information can be found at https://www.nfpa.org.
Attic Insulation Type: Blown Batt |
Attic Insulation Depth: 20 or greater inches |
Attic Ventilation: Ridge vents Soffit Vents Thermostatically controlled fan |
Exhaust Fans: Fan with light |
Dryer Vent: Metal |
Floor System Insulation: R-19 |
Crawlspace Ventillation: No Crawlspace |
Vapor Retarder in Crawlspace: Missing |
IN | NI | NP | RR | ||
7.0 | Insulation in Attic | • | |||
7.1 | Insulation Under Floor System | • | |||
7.2 | Vapor Retarders (in Crawlspace) | • | |||
7.3 | Ventilation of Attic and Foundation Areas | • | |||
7.4 | Venting Systems (Kitchens, Baths and Laundry) | • | |||
7.5 | Ventilation Fans and Thermostatic Controls in Attic | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Ceiling Materials: Gypsum Board |
Wall Material: Gypsum Board |
Floor Covering(s): Hardwood T&G Tile |
Interior Doors: Masonite Raised panel |
Window Types: Double-hung Tilt feature Sliders Dual Pane |
# of Bathrooms: 3.5 |
Whirlpool Tub(s) tested?: No |
IN | NI | NP | RR | ||
8.0 | Ceilings | • | |||
8.1 | Walls | • | |||
8.2 | Floors | • | |||
8.3 | Steps, Stairways, Balconies and Railings | • | |||
8.4 | Counters and Cabinets (including hardware) | • | |||
8.5 | Doors (where accessible) | • | |||
8.6 | Windows (where accessible) | • | |||
8.7 | Bathrooms | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Garage Door Type: Two automatic |
Garage Door Material: Insulated Wood |
Garage Door Openers Intalled?: Yes |
IN | NI | NP | RR | ||
9.0 | Garage Ceilings | • | |||
9.1 | Garage Walls (including Firewall Separation) | • | |||
9.2 | Garage Floor | • | |||
9.3 | Occupant Door (from garage to inside of home) is fire rated | • | |||
9.4 | Garage Vehicle Doors and Garage Door Operators (work normally, auto reverse with resistance, and photo electric eyes are functional) | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Dishwasher Drain: High Loop |
IceMaker: Present Operated Normally |
Free Standing Oven: N/A |
IN | NI | NP | RR | ||
10.0 | Refrigerator (s) | • | |||
10.1 | Dishwasher | • | |||
10.2 | Ranges/Ovens/Cooktops | • | |||
10.3 | Range Hood (s) | • | |||
10.4 | Trash Compactor | • | |||
10.5 | Food Waste Disposer | • | |||
10.6 | Microwave Cooking Equipment | • | |||
10.7 | Washer and Dryer | • | |||
IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace | IN | NI | NP | RR |
Y | No | ||
11.0 | Were all interior rooms and garage fully accessible (including clear of furniture and rugs)? | • | |
11.1 | Were the areas under Bathroom Cabinets visible? | • | |
11.2 | Was the interior of the kitchen cabinets visible? | • | |
11.3 | Were all the attics accessible? | • | |
Y= Yes, No= No | Y | No |
![]() |
INVOICE |
Grey Dog Home Inspections, LLC
12016 Enchanted Ct. Fredericksburg, VA 22407 540-755-6009 Inspected By: Nathan Williams |
Inspection Date: 4/6/2018
Report ID: 180406-1 |
Customer Info: | Inspection Property: |
Mr. Harry Homebuyer
1313 Sample Lane Fredericksburg Virginia 22407 Customer's Real Estate Professional: |
7 Homeowner Way Fredericksburg VA 22407 |
| ||||
Tax $0.00 | ||||
Total Price $0.00 |
Payment Method:
Payment Status:
Note:
![]() Grey Dog Home Inspections, LLC
12016 Enchanted Ct. |
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.