Property Address:
1234 Main Street
Sedona AZ 86326
Paul Stokle
54338
PO Box 21005
Sedona, Arizona 86341
928-284-4064
Date: 5/17/2017 | Time: 12:00 PM | Report ID: Sample 1234 |
Property: 1234 Main Street Sedona AZ 86326 |
Customer: Jane Doe |
Real Estate Professional: Joe Realtor Realtors Help |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Satisfactory (SAT) = I visually observed the item,component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Maintenance Recommended (MR) = The item, component or unit is not functioning as intended, and needs maintenance or monitoring. Further inspection by a qualified contractor, handy man or homeowner is recommended.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
The pictures provided in the report are meant to display and illustrate a described deficiency, and in some instances a sample of the conditions that exist. The pictures provided are not intended to display every location of a general condition.
Please Note: All American Inspection Services LLC does not inspect for mold. If this is important to you, we recommend you contact a licensed mold inspection firm.
Please note that at the time of construction, some of the deficiencies described in this report may not have been required. Some of the recommendations and conditions in this report should be considered upgrades that bring the home's safety more closely to current building safety requirements.
Report Standard: This report is conducted in accordance with the Arizona Standards of Professional Practice for Home Inspectors | Approximate age of building: 1998 | Square Footage of Home: 2925 |
Type of building: Single Family (1 story) | In Attendance: Seller, Client | Home Faces: NE |
Temperature: 91 degrees | Weather: Clear | Radon Test: No |
I INSPECT EVERY HOME AS IF I WERE BUYING IT MYSELF
All homes, regardless of their age, have some defects. Home inspection reports are meant to focus on defects and may seem negative with the respect to the overall condition of the home. Some features of this property may be in excellent condition and of high quality but have not been mentioned, or been deemed adequate in the report. This is not meant to downplay this property’s assets, but to focus on alerting you to potentially expensive problems. Thank you for giving us the opportunity to serve you in your home inspection needs. Please read the entire report carefully. I hope that the information you received assisted you in becoming more knowledgeable about the property you are purchasing.
An earnest effort was made on your behalf to discover all visible defects. The inspection and report are not intended to be technically exhaustive, or to imply that every component was inspected, or that every possible defect was discovered. No disassembly of equipment, openings in walls, moving of furniture, appliances, or stored items, or excavation was done. All components and conditions which by the nature of their location are concealed, camouflaged, or difficult to inspect are excluded from the report. No warranty is either expressed or implied. The entire Inspection Report, including the Arizona Standards of Practice, limitations, scope of the inspection, and pre-inspection agreement must be carefully read to fully understand the findings of the inspection. The report is an opinion report reflecting the visual conditions of the property at the time of the inspection only. While we can reduce your risk of purchasing the subject property, we cannot eliminate it, nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to ownership.
It is strongly recommended that you have an appropriate qualified licensed professional evaluate each concern further and the entire system(s) for additional concerns that may be outside our area of expertise or the scope of our inspection before the close of escrow.
Return visits or re-inspection are billed at a starting fee of $150.00 depending on the specific request.
We will always do everything possible to merit the confidence you have shown in us. Thank you.
Sincere regards,
Paul Stokle, Owner/Inspector
License # 54338
PO Box 21005
Sedona, Arizona 86341
928-284-4064
Customer
Jane Doe
Address
1234 Main Street
Sedona AZ 86326
1.0 | *Roof Coverings | |
Maintenance Recommended | ||
(3) Roof ridge and hip cap tiles had deteriorated or cracked mortar bond.
Recommend repairing these areas to ensure continued roof durability.
|
3.5 | *Roof Structure and **Attic | |
Maintenance Recommended | ||
Mice droppings were found in the attic. A pest control company should inspect
further and correct as needed.
|
6.2 | *Plumbing Water Supply, Distribution System and Fixtures | |
Repair or Replace | ||
Backflow prevention plumbing at the northwest side of the house is leaking.
|
7.8 | *Operation of GFCI (Ground Fault Circuit Interrupters) | |
Repair or Replace | ||
(2) Some outlets in the kitchen are not GFCI outlets. Two of them were to the left of
the stove and one of them was to the right of the stove. The current non GFCI
outlets should be changed over to conforming standards by a licensed electrical
contractor.
|
10.2 | *Venting Systems (Kitchens, Baths and Laundry) | |
Repair or Replace | ||
The exhaust fan did not work at the master bath.
|
*Roof Covering: Concrete tile |
*Method of inspecting roof: Walked roof |
*Evidence of leaking/ signs of moisture on building components: No |
Sky Light(s): None |
Chimney (exterior): Metal Flue Pipe Masonry Stucco |
SAT | NI | MR | RR | NP | ||
1.0 | *Roof Coverings | • | ||||
1.1 | *Flashings | • | ||||
1.2 | *Skylights, Chimneys and Roof Penetrations | • | ||||
1.3 | *Roof Drainage Systems | • | ||||
1.4 | Parapet Walls | • | ||||
SAT | NI | MR | RR | NP |
*Siding Material: Cement Stucco |
Driveway: Concrete |
Walkways: Concrete Flagstone Gravel |
Patio: Concrete Tile |
Exterior Entry Doors: Wood Sliding Glass Door Metal |
Appurtenance: Covered Entryway Covered Patio Walkway |
SAT | NI | MR | RR | NP | ||
2.0 | **Eaves, Soffits and Fascias | • | ||||
2.1 | *Wall Cladding Flashing and Trim | • | ||||
2.2 | *Doors (Exterior) | • | ||||
2.3 | *Windows | • | ||||
2.4 | *Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) | • | ||||
2.5 | **Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings | • | ||||
SAT | NI | MR | RR | NP |
*Foundation: Poured concrete |
*Floor Structure: Concrete slab |
*Wall Structure: Wood framing |
*Ceiling Structure: Wood framing |
*Roof Structure: Engineered wood trusses |
Roof-Type: Gable |
**Columns or Piers: Stucco Covered Columns |
**Method used to observe attic: From air handler work platform |
Attic access: Garage |
**Method used to observe Crawlspace: No crawlspace |
Structure position: Set level with ground |
SAT | NI | MR | RR | NP | ||
3.0 | *Foundations, Basement and **Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | • | ||||
3.1 | *Walls (Structural) | • | ||||
3.2 | *Ceilings (Structural) | • | ||||
3.3 | *Floors (Structural) | • | ||||
3.4 | **Columns or Piers | • | ||||
3.5 | *Roof Structure and **Attic | • | ||||
SAT | NI | MR | RR | NP |
Shrinkage cracks are often visible and are not a structural concern. It is possible for moisture to enter the foundation through these cracks by capillary action and within the home structure this moisture may cause damage typically detectable only through invasive techniques that lie beyond the scope of the General Home Inspection.
No Standards exist for evaluating cracks in concrete. Cracks appear for a wide variety of reasons, some of which may not be apparent at the time of the inspection. Cracks less than ¼-inch which do not exhibit displacement are typically not considered to be structural issues unless they appear in conjunction with another condition.
Garage Door Type: Two automatic Roll-up |
Garage Door Material: Metal |
Auto-opener Manufacturer: GENIE LIFT-MASTER |
SAT | NI | MR | RR | NP | ||
4.0 | *Garage Ceilings | • | ||||
4.1 | *Garage Walls (including Firewall Separation) | • | ||||
4.2 | *Garage Floor | • | ||||
4.3 | Vehicle Garage Door (s) | • | ||||
4.4 | *Occupant Door (from garage to inside of home) | • | ||||
4.5 | *Garage Door Operators (Report whether or not doors will reverse when met with resistance) | • | ||||
4.6 | Garage door to exterior | • | ||||
4.7 | Garage Cabinets/Closets | • | ||||
4.8 | Garage Windows | • | ||||
SAT | NI | MR | RR | NP |
*Heat Type: Forced Air |
*Energy Source: Natural gas |
Heat System Brand: LENNOX |
Number of Heat Systems/ Location (excluding wood): Two Attic Garage |
Ductwork: Insulated |
Airflow at vents: Adequate |
*Air filter type/ condition: Disposable Satisfactory |
**Types of Fireplaces: Gas Logs |
Operable Fireplaces: Two |
*Cooling Equipment Type: Split system central air conditioning |
*Cooling Equipment Energy Source: Electricity Rating BTU/Ton : Two 4 ton units |
Number of air conditioning units and locations: Northwest exterior Two Manufacture Date : September 1998 Both units |
Air Conditioning Manufacturer: LENNOX Serial # : 5898J17893, 5898J17908 |
SAT | NI | MR | RR | NP | ||
5.0 | *Heating Equipment | • | ||||
5.1 | *Normal Operating Controls | • | ||||
5.2 | *Automatic Safety Controls | • | ||||
5.3 | *Cooling and Air Handler Equipment | • | ||||
5.4 | Air Handler Platform | • | ||||
5.5 | Condensate drain system | • | ||||
5.6 | Refrigerant lines | • | ||||
5.7 | *Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | • | ||||
5.8 | *Presence of Installed Heating/Cooling Source in Each Room | • | ||||
5.9 | *Chimneys, Flues and Vents (for fireplaces or heat systems) | • | ||||
5.10 | **Solid Fuel Heating Devices (Fireplaces, Woodstove) | • | ||||
5.11 | Gas/LP Firelogs and Fireplaces | • | ||||
SAT | NI | MR | RR | NP |
As is typical with split systems, the compressor/condenser cabinets were located at the home's exterior so that the heat collected inside the home could be released to the outside air.
Evaporator coils designed to collect heat from the home interior were located inside the air ducts at the furnaces.
Main water shut off location: North Exterior At meter |
Main water shut off size/ type: Ball valve Undetermined Extra Info : size not determined |
Water pressure: 55 PSI |
Plumbing Water Supply (into home): Not visible |
*Plumbing Water Distribution (inside home): Copper |
*Plumbing Waste and Vent Piping System: PVC |
*Water Heater Power Source: Natural gas |
Water Heater Capacity: Unknown |
Water Heater Manufacturer: UNKNOWN |
Water Heater Location: Garage |
Gas shut off location: North West Exterior |
Fuel type: Natural gas |
SAT | NI | MR | RR | NP | ||
6.0 | *Plumbing Drain, Waste and Vent Systems | • | ||||
6.1 | *Functional Drainage | • | ||||
6.2 | *Plumbing Water Supply, Distribution System and Fixtures | • | ||||
6.3 | *Water Piping Supports and Insulation | • | ||||
6.4 | *Hot Water Systems and Controls. | • | ||||
6.5 | *Water Heater Automatic Safety Controls (TPR Valve, Thermocouple, etc) | • | ||||
6.6 | *Hot Water System Flues and Vents | • | ||||
6.7 | Water Heater Platform | • | ||||
6.8 | *Functional Water Flow | • | ||||
6.9 | **Cross connections | • | ||||
6.10 | *Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks) | • | ||||
6.11 | Fire Suppresion System | • | ||||
6.12 | *Sump Pump | • | ||||
SAT | NI | MR | RR | NP |
Gas water heaters heat water using a gas burner located in a chamber beneath the water tank. The gas control mechanism contains safety features designed to prevent gas from leaking into the living space if the burner should fail for some reason.
Gas-fired water heaters must be properly installed so that the gas fuel is safely delivered to the water heater and so that the water heater safely exhausts the products of combustion to the home exterior.
The life span of water heaters depends upon the following:
- The quality of the water heater
- The chemical composition of the water
- The long-term water temperature settings
- The quality and frequency of past and future maintenance
Flushing the water heater tank once a year and replacing the anode every four years will help extend its life span.
You should keep the water temperature set at a minimum of 120 degrees Fahrenheit to kill microbes and a maximum of 125 degrees to prevent scalding.
*Electrical Service Conductors: Below ground Copper 220/110 volts |
*Panel capacity: 200 AMP |
*Panel Type (protection devices): Circuit breakers |
Electric Panel Manufacturer: GENERAL ELECTRIC |
Branch wire 15 and 20 AMP: Copper |
Wiring Methods: Romex |
Electrical service ground: Present in panel. Not visible beyond panel |
SAT | NI | MR | RR | NP | ||
7.0 | *Location of Main and Distribution Panels | • | ||||
7.1 | *Service Entrance Conductors | • | ||||
7.2 | *Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels | • | ||||
7.3 | Photovoltaic System | • | ||||
7.4 | *Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage | • | ||||
7.5 | *Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | • | ||||
7.6 | *Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure | • | ||||
7.7 | *Operation of AFCI (Arc Fault Circuit Interrupters) | • | ||||
7.8 | *Operation of GFCI (Ground Fault Circuit Interrupters) | • | ||||
7.9 | Doorbell | • | ||||
7.10 | Smoke Detectors | • | ||||
SAT | NI | MR | RR | NP |
The clear working space required in front of a panel is 30" wide by 36" deep with a minimum headroom clearance of 6' 6".
Ceiling Materials: Gypsum Board |
Wall Material: Gypsum Board |
Floor Covering(s): Area rug Carpet Tile |
Window Types: Block Fixed Pane Sliders Dual Pane |
SAT | NI | MR | RR | NP | ||
8.0 | *Ceilings | • | ||||
8.1 | *Walls | • | ||||
8.2 | *Floors | • | ||||
8.3 | **Steps, Stairways, Balconies and Railings | • | ||||
8.4 | *Counters and Cabinets other than Kitchen and Bathrooms | • | ||||
8.5 | *Doors (representative number) | • | ||||
8.6 | *Windows (representative number) | • | ||||
8.7 | Closets | • | ||||
8.8 | Limited Viewing | • | ||||
SAT | NI | MR | RR | NP |
Countertop: Granite |
Dishwasher drain: High loop method |
Range/ Oven: Electrical Separate stovetop (gas) |
SAT | NI | MR | RR | NP | ||
9.0 | Sink | • | ||||
9.1 | *Countertops | • | ||||
9.2 | *Cabinets | • | ||||
9.3 | Dishwasher | • | ||||
9.4 | Ranges/Ovens/Cooktops | • | ||||
9.5 | Range Hood (s) | • | ||||
9.6 | Microwave | • | ||||
9.7 | Food Waste Disposer | • | ||||
9.8 | Trash Compactor | • | ||||
9.9 | Built in Refrigerator | • | ||||
SAT | NI | MR | RR | NP |
*Attic Insulation: R-30 or better Batt |
Attic ventilation: Soffit Vents Roof Vents |
Bathroom ventilation: Exhaust fan |
Laundry ventilation: Exhaust fan |
Dryer Power Source: Gas Connection |
*Dryer Vent: Metal |
*Floor System Insulation: Unknown |
*Vapor Retarder: Unknown |
SAT | NI | MR | RR | NP | ||
10.0 | *Insulation in Attic | • | ||||
10.1 | *Ventilation of Attic and Foundation Areas | • | ||||
10.2 | *Venting Systems (Kitchens, Baths and Laundry) | • | ||||
10.3 | **Insulation Under Floor System | • | ||||
10.4 | *Vapor Retarders (in Crawlspace or basement) | • | ||||
10.5 | *Vapor Retarders (in Attic) | • | ||||
SAT | NI | MR | RR | NP |
SAT | NI | MR | RR | NP | ||
11.0 | Toilet | • | ||||
11.1 | Sink | • | ||||
11.2 | Bathtub | • | ||||
11.3 | Shower | • | ||||
11.4 | *Countertops/ Cabinets | • | ||||
11.5 | Bidet | • | ||||
SAT | NI | MR | RR | NP |
There are several types of roofing materials and each has its pros and cons. Besides being made from different materials, each type also has a different life expectancy. No matter the basic material, all roofs need to be kept free of debris such as leaves and dirt. Keeping the roof clear not only allows the roofing materials to perform the way they were designed, it makes the house look better. An annual inspection of the roof is also an important part of maintenance.
A tile roof is well suited to the Arizona climate. The average life expectancy is approximately 50 years, depending on maintenance. However, if not installed properly, leaks or other problems may begin to appear. Improper installation can allow the tiles to move out of their intended position or actually fall off the roof which may be dangerous to innocent bystanders. With tiles out of place, water may then penetrate the roof. Once a leak begins, the roof can deteriorate quickly.
Broken roof tiles are common on homes of all ages, even brand new homes. These damaged tiles can allow water infiltration and damage to the roof’s substructure, eventually leading to leaks. As such, homeowners should have a roof inspection annually, and any broken tiles should be replaced. A few cracked tiles are relatively inexpensive to replace when compared to the cost of a whole new roof. Sometimes it is possible to glue the tile back together.
Hiring a professional is a smart choice when it comes to both the inspection and the repairs.
The annual inspection should include a check of the roof penetrations and valleys as well. Roof flashings on a tile roof are the most likely location for leaks to develop. Problems with roof flashings are common in all types of houses, even newly constructed homes.
Nothing will completely eliminate the possibility of a roof leak. However, a little preventative maintenance and vigilance can help reduce the risk. Catching problems early will greatly reduce your costs when problems do arise.
This report is an opinion of the general quality and condition of the roof. The inspector cannot and does not offer an opinion or warranty and to whether the roof has leaked in the past or may be subject to future leakage. NOTE: The remaining life span of the roofing paper under roof tiles cannot be determined, typical life span is less than 20 years.