Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Customer | Type of building: Single Family (2 story) | Approximate age of building: Over 25 Years |
Temperature: Over 65 (F) = 18 (C) | Weather: Clear | Ground/Soil surface condition: Damp |
Rain in last 3 days: Yes |
|
Styles & Materials
Roof Covering: 3-Tab fiberglass Viewed roof covering from: Ladder Walked roof Sky Light(s): None Estimated AGE OF ROOF: Over 25 years old |
|
Styles & Materials
Siding Style: Lap Siding Material: Cedar Exterior Entry Doors: Steel Appurtenance: Covered porch Sidewalk Driveway: Concrete |
One or more sections on front porch ceilings shows signs of active water intrusion. Recommend having a qualified contractor repair/replace roofing shingles,flashing,repair damaged/rotting wood and sheathing as needed.
|
Styles & Materials
Ceiling Materials: Sheet-Rock Walls: Sheet-Rock Floor Covering(s): Carpet Hardwood T&G Linoleum Interior Doors: Hollow core Window Types: Single-hung Casement Window Manufacturer: UNKNOWN Cabinetry: Veneer Countertop: Laminate |
One or more minor/medium cracks found on ceilings. Repair/Replace.
|
Styles & Materials
Foundation: Masonry block Method used to observe Crawlspace: Crawled Limited access Floor Structure: 2 X 8 Wood joists Wall Structure: 2 X 4 Wood Columns or Piers: Wood piers Masonry block Ceiling Structure: Not visible Roof Structure: Engineered wood trusses Plywood Sheathing Roof-Type: Gable Method used to observe attic: Walked Attic info: Pull Down stairs |
Vapor barrier is missing. Recommend installing 6 mil polyethylene with seams overlapped at least 24" so no soil is exposed in the crawlspace.
No insulation under floor in crawl space. Recommend installing R19 or better (6" thick fiberglass batt) insulation below floor for energy efficiency.
Inspector also notices some mildew/mold like stains on joist and crawl space surfaces. Repair/Replace as needed.
Cover plate(s) are missing from one or more electric junction boxes inside attic. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard and poses a risk of both fire and shock. Recommend installing cover plates over junction boxes where missing.
|
Styles & Materials
Water Source: Well Public Water Filters: None Plumbing Water Supply (into home): Not visible Plumbing Water Distribution (inside home): Copper PVC Washer Drain Size: Not visible Plumbing Waste: PVC Water Heater Power Source: Electric Water Heater Capacity: 50 Gallon (2-3 people) Water Heater Location: Utility Room WH Manufacturer: WHIRLPOOL Extra Info : SN: 043817236 Septic Tank: Below Ground, Not Inspected Age Of Water Heater: 15 to 20 years old |
Substandard wiring was found for the water heater's power supply. This is both a fire and a shock hazard. Recommend having a qualified, licensed electrician evaluate and make repairs as necessary. Typically, electric water heater power supply wires require flexible, armored "BX" conduit, bushing(s) and possibly a covered junction box.
The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older. Recommend budgeting for a replacement in the near future.
It appears that water heater has been converted to electric due to above missing vent flue hole above water heater.
|
Styles & Materials
Electrical Service Conductors: Overhead service 220 volts Panel Capacity: 200 AMP Panel Type: Circuit breakers Electric Panel Manufacturer: GENERAL ELECTRIC Branch wire 15 and 20 AMP: Copper Wiring Methods: Romex |
No ground fault circuit interrupter (GFCI) devices (receptacles or circuit breakers) are visible in one or more kitchen or bathrooms. GFCI devices help prevent electric shocks in areas that may have water present. Recommend having a qualified, licensed electrician install GFCI protection for receptacles over counter tops and around sinks as per standard building practices.
|
Styles & Materials
Heat Type: None Extra Info : Home has a propane tank in backyard. It's posiable that home used propane to heat the home. Energy Source: Propane Number of Heat Systems (excluding wood): None Heat System Brand: NONE Ductwork: Non-insulated Types of Fireplaces: None Cooling Equipment Type: Window AC Number of AC Only Units: None Central Air Brand: NONE |
|
Styles & Materials
Attic Insulation: Batt Fiberglass R-19 or better Ventilation: Gable vents Exhaust Fans: Fan only Dryer Power Source: 220 Electric Dryer Vent: Metal Floor System Insulation: NONE |
|
Styles & Materials
Dishwasher Brand: NONE Disposer Brand: NONE Exhaust/Range hood: NONE Range/Oven: ROPER Built in Microwave: NONE Trash Compactors: NONE |
950 Eagles Landing Pkwy. Suite 134
Stockbridge, Georgia 30281
770-855-3073
1-888-523-6094
Customer
Mr. John Doe
Address
2300 Sample St
Decatur Georgia 30032
1.0 | Roof Coverings | |
Inspected, Repair or Replace | ||
One or more shingles damaged/missing and have hail and wind damaged. Recommend having a qualified roofing contractor
evaluate and repair/replace/install a new roof.
$2,501 - $5,000 ![]() 1.0 Item 1(Picture)
![]() 1.0 Item 2(Picture)
![]() 1.0 Item 3(Picture)
![]() 1.0 Item 4(Picture)
|
1.3 | Roof Drainage Systems | |
Inspected, Repair or Replace | ||
One or more gutters missing around the home. Recommend having a qualified contractor evaluate and repair/replace.
$501 - $1000 ![]() 1.3 Item 1(Picture)
|
2.0 | Wall Cladding Flashing and Trim | |
Inspected, Repair or Replace | ||
One or more siding boards around the home has wood rot/wood decay/damaged. Recommend having a qualified contractor
evaluate and repair/replace.
$250 - $500 ![]() 2.0 Item 1(Picture)
|
2.2 | Windows | |
Inspected, Repair or Replace | ||
One or more windows and window frames around the home is damaged/not operating correctly and have wood rot/wood
decay. Recommend having a qualified contractor evaluate and repair/replace.
$1,000 - $2,500 ![]() 2.2 Item 1(Picture)
![]() 2.2 Item 2(Picture)
![]() 2.2 Item 3(Picture)
![]() 2.2 Item 4(Picture)
|
2.3 | Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings | |
Inspected, Repair or Replace | ||
Decking around the home shows signs of settlement and wood rot/wood decay. Recommend having a qualified contractor
evaluate and repair/replace and rebuild wrap around porch if needed.
One or more sections on front porch ceilings shows signs of active water intrusion. Recommend having a qualified contractor repair/replace roofing shingles,flashing,repair damaged/rotting wood and sheathing as needed. $1,000 - $2,500 ![]() 2.3 Item 1(Picture)
![]() 2.3 Item 2(Picture)
![]() 2.3 Item 3(Picture)
![]() 2.3 Item 4(Picture)
|
2.5 | Eaves, Soffits and Fascias | |
Inspected, Repair or Replace | ||
One or more section around the home have wood rot/wood decay on soffits and fascias boards around the home. One or
more gutters missing around the home. Recommend having a qualified contractor evaluate and repair/replace.
$250 - $500 ![]() 2.5 Item 1(Picture)
![]() 2.5 Item 2(Picture)
|
2.6 | Wood Infeatation Insects | |
Inspected, Repair or Replace | ||
Recommend asking seller if home has a termite bond and if so, recommend asking seller if termite bond is transferable to
new owner. If not recommend having home treated and protected from wood destroying insects/termites.
|
3.2 | Floors | |
Inspected, Repair or Replace | ||
One or more floors inside home shows signs of settlement and warping/un-leveled. Recommend having a qualified
contractor evaluate and repair/replace.
$2,501 - $5,000 ![]() 3.2 Item 1(Picture)
![]() 3.2 Item 2(Picture)
|
3.5 | Doors (representative number) | |
Inspected, Repair or Replace | ||
One or more doors binding. Recommend having a qualified contractor evaluate and repair/replace.
$101 - $250 |
3.7 | Mildew/mold like substance/stains | |
Inspected, Repair or Replace | ||
Mold and mildew found on one or more sections of walls in laundry room. Recommend having a qualified contractor
evaluate and repair/replace and repair any plumbing leaks/water intrusion that caused the issue.
$501 - $1000 ![]() 3.7 Item 1(Picture)
![]() 3.7 Item 2(Picture)
![]() 3.7 Item 3(Picture)
|
4.0 | Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | |
Inspected, Repair or Replace | ||
Inspector noticed signs of some water intrusion entering into crawl space. Recommend having a qualified contractor
evaluate and repair/replace.
Vapor barrier is missing. Recommend installing 6 mil polyethylene with seams overlapped at least 24" so no soil is exposed in the crawlspace. No insulation under floor in crawl space. Recommend installing R19 or better (6" thick fiberglass batt) insulation below floor for energy efficiency. Inspector also notices some mildew/mold like stains on joist and crawl space surfaces. Repair/Replace as needed. $1,000 - $2,500 ![]() 4.0 Item 1(Picture)
![]() 4.0 Item 2(Picture)
|
4.3 | Floors (Structural) | |
Inspected, Repair or Replace | ||
Recommend having a qualified contractor evaluate and re-support floor structure to correct and repair settlement problems.
$2,501 - $5,000 ![]() 4.3 Item 1(Picture)
|
4.5 | Roof Structure and Attic | |
Inspected, Repair or Replace | ||
Inspector noticed signs of water intrusion entering into attic. Recommend having roof replaced.
Cover plate(s) are missing from one or more electric junction boxes inside attic. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard and poses a risk of both fire and shock. Recommend installing cover plates over junction boxes where missing. $5,000 - $10,000 ![]() 4.5 Item 1(Picture)
![]() 4.5 Item 2(Picture)
![]() 4.5 Item 3(Picture)
|
5.0 | Plumbing Drain, Waste and Vent Systems | |
Inspected, Repair or Replace | ||
Recommend having septic tank inspected. Recommend pumping tank if last pumped more than 3 years ago.
$250 - $500 |
5.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents | |
Inspected, Repair or Replace | ||
The water heater's temperature-pressure relief valve drain line is missing. This poses a danger of scalding if someone is
standing next to the water heater when the valve releases. A qualified plumber should install a drain line as per standard
building practices. For example, extending to within 6" from the floor, or routed so as to drain outside.
Substandard wiring was found for the water heater's power supply. This is both a fire and a shock hazard. Recommend having a qualified, licensed electrician evaluate and make repairs as necessary. Typically, electric water heater power supply wires require flexible, armored "BX" conduit, bushing(s) and possibly a covered junction box.
The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older. Recommend budgeting for a replacement in the near future. It appears that water heater has been converted to electric due to above missing vent flue hole above water heater. $501 - $1000 ![]() 5.2 Item 1(Picture)
![]() 5.2 Item 2(Picture)
![]() 5.2 Item 3(Picture)
|
5.6 | Septic Tank System | |
Inspected, Repair or Replace | ||
Recommend having septic tank pump and evaluated by a qualified septic tank contractor.
$250 - $500 |
6.3 | Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
Inspected, Repair or Replace | ||
Five or more open ground, 3-pronged receptacles were found in front room/family room. This is a safety hazard and poses a
risk of electric shock. Recommend that a qualified, licensed electrician evaluate and make repairs as necessary. For
example, replacing receptacles or correcting wiring circuits.
No ground fault circuit interrupter (GFCI) devices (receptacles or circuit breakers) are visible in one or more kitchen or bathrooms. GFCI devices help prevent electric shocks in areas that may have water present. Recommend having a qualified, licensed electrician install GFCI protection for receptacles over counter tops and around sinks as per standard building practices. $101 - $250 ![]() 6.3 Item 1(Picture)
|
8.1 | Vapor Retarders (in Crawlspace or basement) | |
Inspected, Repair or Replace | ||
Vapor barrier is missing. Recommend installing 6 mil polyethylene with seams overlapped at least 24" so no soil is
exposed in the crawlspace.
$250 - $500 ![]() 8.1 Item 1(Picture)
|
8.3 | Venting Systems (Kitchens, Baths and Laundry) | |
Inspected, Repair or Replace | ||
One or more bathrooms with a shower don't have an exhaust fan installed. Even if a window that opens exists, it may not
provide adequate ventilation, especially during cold weather when the window is less likely to be opened. Recommend
having a qualified contractor install an exhaust fan, duct and vent cap as per standard building practices in bathrooms with
showers where missing.
$101 - $250 ![]() 8.3 Item 1(Picture)
|
![]() |
INVOICE |
Eagles Eye Home Inspection, LLC tm
950 Eagles Landing Pkwy. Suite 134 Stockbridge, Georgia 30281 770-855-3073 1-888-523-6094 Inspected By: Quinton Goodrum |
Inspection Date: 6/24/2018
Report ID: Sample2300 |
Customer Info: | Inspection Property: |
Mr. John Doe
2300 Sample St Warsaw New York 40567 Customer's Real Estate Professional: |
2300 Sample St Decatur Georgia 30032 |
| ||||
Tax $0.00 | ||||
Total Price $0.00 |
Payment Method: Check
Payment Status: Paid At Time Of Inspection
Note: