Property Address:
123 Your House Drive
Fort Lauderdale FL 33312
Robert Melendez, MPA, CMI
HI548
5931 Ravenswood Road Unit A17
Fort Lauderdale, Florida 33312
954-609-2315
Date: 3/4/19 | Time: 03:40 PM | Report ID: Sample Report2019 |
Property: 123 Your House Drive Fort Lauderdale FL 33312 |
Customer: Ms. Jane Doe |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Accessibility Disclaimer = This home is occupied with furnishings, storage items, property, etc. with Limited visual accessibility. RMI Inspection Services and/or the licensed inspector is not responsible & makes no claims to those inaccessible areas.
Termite (WDO) Report Exclusion = RMI Inspection Services is not a pest control company and it's report and services are independent of the pest control inspection and services. The termite/pest control company performs that and only portion of the inspection as a 3rd party. Any & all issues arising from the termite(WDO) inspection is solely the pest control company responsibilities. RMI Inspections Services makes no claims or warranties.
In Attendance: Client & Agent | Type of building: Single Family (1 story) | Style of Home: Ranch |
Approximate age of building: 26 Years Old | Home Faces: South | Temperature: 82 Degrees |
Weather: Clear | Ground/Soil surface condition: Dry | Rain in last 3 days: No |
Radon Test: Yes | Water Test: No | Mold Testing: Yes - See Inspector Lab Mold Analysis Report |
Accessibility Disclaimer: This home has accessibility issues. See Above Disclaimer |
The inspector is not required to: Walk on any roof surface, predict the service life expectancy, inspect underground downspout diverter drainage pipes, remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces, move insulation, inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. Walk on any roof areas that appear, in the opinion of the inspector to be unsafe, and or cause damage. Perform a water test, warrant or certify the roof. Confirm proper fastening or installation of any roof material.
Roof Covering: Concrete Tile |
Viewed roof covering from: Walked roof |
Sky Light(s): None |
The inspector is not required to: Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting, Inspect items, including window and door flashings, which are not visible or readily accessible from the ground, Inspect geological, geotechnical, hydrological and/or soil conditions, Inspect recreational facilities, playground equipment. Inspect seawalls, break-walls and docks, Inspect erosion control and earth stabilization measures, Inspect for safety type glass, Inspect underground utilities, Inspect underground items, Inspect wells or springs, Inspect solar, wind or geothermal systems, Inspect swimming pools or spas, Inspect wastewater treatment systems septic systems or cesspools, Inspect irrigation or sprinkler systems, Inspect drain fields or drywells, Determine the integrity of multi-pane window glazing or the thermal window seals.
Siding Style: Cement stucco |
Siding Material: Masonry |
Exterior Entry Doors: Steel |
Appurtenance: Covered porch |
Driveway: Pavers(Brick) |
The inspector is not required to: Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector, Move stored items or debris, Operate sump pumps with inaccessible floats, Identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems, Provide any engineering or architectural service, Report on the adequacy of any structural system or component.
Foundation: Monolithic Concrete Slab |
Method used to observe Crawlspace: No crawlspace |
Floor Structure: Slab |
Wall Structure: Masonry |
Columns or Piers: Masonry block |
Ceiling Structure: 2X4 |
Roof Structure: Engineered wood trusses Plywood Sheathing |
Roof-Type: Hip |
Method used to observe attic: From entry Inaccessible |
Attic info: Light in attic 2 Attic Hatches |
The inspector is not required to: Inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating systems, solar heating systems or fuel tanks. Inspect underground fuel tanks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. Light or ignite pilot flames. Activate heating, heat pump systems, or other heating systems when ambient temperatures or when other circumstances are not conducive to safe operation or may damage the equipment. Override electronic thermostats. Evaluate fuel quality. Verify thermostat calibration, heat anticipation or automatic setbacks, timers, programs or clocks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. Inspect window units, through-wall units, or electronic air filters. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks. Examine electrical current, coolant fluids or gasses, or coolant leakage. Inspect the flue or vent system. Inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep. Operate gas fireplace inserts. Light pilot flames. Determine the appropriateness of such installation. Inspect automatic fuel feed devices. Inspect combustion and/or make-up air devices. Inspect heat distribution assists whether gravity controlled or fan assisted. Ignite or extinguish fires. Determine draft characteristics. Move fireplace inserts, stoves, or firebox contents. Determine adequacy of draft, perform a smoke test or dismantle or remove any component. Perform an NFPA inspection. Perform a Phase 1 fireplace and chimney inspection.
Heat Type: Forced Air |
Energy Source: Electric |
Number of Heat Systems (excluding wood): One |
Heat System Brand: AMERICAN STANDARD |
Ductwork: Insulated |
Filter Type: Washable |
Filter Size: Adequate |
Cooling Equipment Type: Central Split Air Conditioning |
Cooling Equipment Energy Source: Electricity |
Number of AC Only Units: One |
Central Air Brand: AMERICAN STANDARD |
The inspector is not required to: Light or ignite pilot flames. Determine the size, temperature, age, life expectancy or adequacy of the water heater. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler systems. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. Determine the water quality or potability or the reliability of the water supply or source. Open sealed plumbing access panels. Inspect clothes washing machines or their connections. Operate any main, branch or fixture valve. Test shower pans, tub and shower surrounds or enclosures for leakage. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. Determine whether there are sufficient clean-outs for effective cleaning of drains. Evaluate gas, liquid propane or oil storage tanks. Inspect any private sewage waste disposal system or component of. Inspect water treatment systems or water filters. Inspect water storage tanks, pressure pumps or bladder tanks. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. Evaluate or determine the adequacy of combustion air. Test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief valves. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.
Water Source: Public |
Water Filters: (We do not inspect filtration systems) |
Plumbing Water Supply (into home): Copper |
Plumbing Water Distribution (inside home): Copper |
Washer Drain Size: 2" Diameter |
Plumbing Waste: PVC |
Water Heater Power Source: Electric |
Water Heater Capacity: 40 Gallon (1-2 people) |
Water Heater Location: Garage |
WH Manufacturer: RHEEM |
The inspector is not required to: Insert any tool, probe or device into the main panel, sub-panels, downstream panel, or electrical fixtures. Operate electrical systems that are shut down. Remove panel covers or dead front covers if not readily accessible. Operate over current protection devices. Operate non-accessible smoke detectors. Measure or determine the amperage or voltage of the main service if not visibly labeled. Inspect the alarm system and components. Inspect the ancillary wiring or remote control devices. Activate any electrical systems or branch circuits which are not energized. Operate overload devices. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices. Verify the continuity of the connected service ground. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. Inspect spark or lightning arrestors. Conduct voltage drop calculations. Determine the accuracy of breaker labeling. Inspect exterior lighting.
Electrical Service Conductors: Below ground |
Panel Capacity: 200 AMP |
Panel Type: Circuit breakers |
Electric Panel Manufacturer: CHALLENGER |
Branch wire 15 and 20 AMP: Copper |
Wiring Methods: Romex |
Attic Insulation: Batt Fiberglass R-19 or better |
Ventilation: Soffit Vents |
Exhaust Fans: Fan |
Dryer Power Source: 220 Electric |
Dryer Vent: Flexible Metal |
The inspector shall: Open and close a representative number of doors and windows. Inspect the walls, ceilings, steps, stairways, and railings. Inspect garage doors and garage door openers by operating first by remote (if available) and then by the installed automatic door control. And report as in need of repair any installed electronic sensors that are not operable or not installed at proper heights above the garage door. And report as in need of repair any door locks or side ropes that have not been removed or disabled when garage door opener is in use. And report as in need of repair any windows that are obviously fogged or display other evidence of broken seals.
The inspector is not required to: Inspect paint, wallpaper, window treatments or finish treatments. Inspect central vacuum systems. Inspect safety glazing. Inspect security systems or components. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or firewall compromises. Move furniture, stored items, or any coverings like carpets or rugs in order to inspect the concealed floor structure. Move drop ceiling tiles. Inspect or move any household appliances. Inspect or operate equipment housed in the garage except as otherwise noted. Verify or certify safe operation of any auto reverse or related safety function of a garage door. Operate or evaluate security bar release and opening mechanisms, whether interior or exterior, including compliance with local, state, or federal standards. Operate any system, appliance or component that requires the use of special keys, codes, combinations, or devices. Operate or evaluate self-cleaning oven cycles, tilt guards/latches or signal lights. Inspect microwave ovens or test leakage from microwave ovens. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or other small, ancillary devices. Inspect elevators. Inspect remote controls. Inspect appliances. Inspect items not permanently installed. Examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed pool/spa, recreational equipment or self-contained equipment. Come into contact with any pool or spa water in order to determine the system structure or components. Determine the adequacy of spa jet water force or bubble effect. Determine the structural integrity or leakage of a pool or spa.
Ceiling Materials: Gypsum Board |
Wall Material: Gypsum Board |
Floor Covering(s): Tile |
Interior Doors: Hollow core Raised panel |
Window Types: Single pane |
Cabinetry: Laminate |
Countertop: Laminate |
Garage Door Type: One automatic |
Garage Door Material: Metal |
Auto-opener Manufacturer: LIFT-MASTER 1/2 HORSEPOWER |
5931 Ravenswood Road Unit A17
Fort Lauderdale, Florida 33312
954-609-2315
Customer
Ms. Jane Doe
Address
123 Your House Drive
Fort Lauderdale FL 33312
1.0 | Roof Coverings | |
Inspected, Repair or Replace | ||
(1)
The roof covering is in very poor condition and is leaking. It has many signs that life expectancy has been reached. The roof appears to have many areas repairs were made. It comes to a point where repairs, damage and deteriorated roof needs to be re-roof. It is recommended that a new roof be installed. Note a roof in this condition will make it difficult to obtain home owners insurance.![]() 1.0 Item 1(Picture) Roof Repairs Noted
![]() 1.0 Item 2(Picture) Cracked Tiles
![]() 1.0 Item 3(Picture) Cracked Tiles
![]() 1.0 Item 4(Picture) Cracked Tiles
![]() 1.0 Item 5(Picture) Signs Underlayment is Failing
![]() 1.0 Item 6(Picture) Poor Roof Repair Noted
|
||
(2)
Tree limbs in contactor or hanging over the roof line should be removed. It causes premature wear of the roof covering and under layments. Have a licensed arborist and/or tree contactor trim or remove as needed.![]() 1.0 Item 7(Picture) Tree Limbs
|
1.3 | Roof Drainage Systems | |
Inspected, Repair or Replace | ||
Rain gutters are needed to prevent soil erosion. Have a licensed rain gutter contractor install as needed.![]() 1.3 Item 1(Picture) Soil Erosion
|
2.1 | Doors (Exterior) | |
Inspected, Repair or Replace | ||
In the hallway bathroom the exterior door that leads to outside patio area is oxidized and is very difficult to open or close door properly. Have a licensed door contractor repair or replace as needed.![]() 2.1 Item 1(Picture) Rear Bathroom Door
|
2.4 | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) | |
Inspected, Repair or Replace | ||
On the left side of the paved driveway there are signs of uneven pavers. Have a licensed stone or paving contactor repair or replace as needed.![]() 2.4 Item 1(Picture) Driveway
![]() 2.4 Item 2(Picture) Driveway
|
2.5 | Eaves, Soffits and Fascias | |
Inspected, Repair or Replace | ||
Many of the fascia boards and soffits throughout the home are deteriorated and have rot.Have a licensed roofing contractor repair or replace as needed.![]() 2.5 Item 1(Picture) Fascia Boards
![]() 2.5 Item 2(Picture) Fascia Boards
![]() 2.5 Item 3(Picture) Fascia Boards
|
4.3 | Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Inspected, Repair or Replace | ||
The A/C condensing unit securing bracket to the concrete slab is oxidized. Have a licensed HVAC contractor repair or replace as needed.![]() 4.3 Item 1(Picture) A/C Securing Bracket
|
4.5 | Cooling and Air Handler Equipment | |
Inspected, Repair or Replace | ||
(1)
Note air handler wood water stains with microbial growth. Have a licensed mold remediator clean as needed.![]() 4.5 Item 1(Picture) Air Handler
|
||
(2)
Air vent, Air handler and register was swab for microbial growth. Air samples were taken throughout the home for mold evaluation due to roof leaks. See mold report.![]() 4.5 Item 2(Picture) Air Handler
|
5.1 | Plumbing Water Supply, Distribution System and Fixtures | |
Inspected, Repair or Replace | ||
The hallway bathroom shower diverter, the pull pin that changes from tub to shower water flow is stuck in the shower position. Have a licensed plumbing contractor repair or replace as needed.![]() 5.1 Item 1(Picture) Hallway Bathroom
|
5.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents | |
Inspected, Repair or Replace | ||
The dryer exhaust is dirty and outside diverter is crushed. Have a licensed contractor clean and repair or replace as needed.![]() 5.2 Item 1(Picture) Dryer Exhaust Vent
![]() 5.2 Item 2(Picture) Dryer Vent
|
7.0 | Insulation in Attic | |
Inspected, Repair or Replace | ||
Inside attic moisture meter was utilized. Wet insulation was found. This will the drywall to remain wet and mold issues to occur. Have a licensed contractor repair or replace as needed.![]() 7.0 Item 1(Picture) Wet Insulation
|
8.0 | Ceilings | |
Inspected, Repair or Replace | ||
Upon conversation with selling agent ceiling and roof have been repairs made. Moisture meter and infrared camera were utilized and indicate throughout the home there are still signs of roof leaks. Have a licensed contractor repair or replace as needed.![]() 8.0 Item 1(Picture) Infrared Camera Utilized
![]() 8.0 Item 2(Picture) Moisture Meter
![]() 8.0 Item 3(Picture) Infrared Camera Indicating Moisture on Ceiling
|
8.5 | Doors (representative number) | |
Inspected, Repair or Replace | ||
This hallway closet door is not on track. Have a licensed door contractor repair or replace as needed.![]() 8.5 Item 1(Picture) Hallway Closet
|
8.6 | Windows (representative number) | |
Inspected, Repair or Replace | ||
Dining room picture window has a crack. Have a licensed window contractor repair or replace as needed.![]() 8.6 Item 1(Picture) Dining Room
|
9.4 | Occupant Door (from garage/carport to inside of home) | |
Inspected, Repair or Replace | ||
The occupant door that leads from the garage should be on a self closing devise. Have a licensed door contractor repair or replace as needed.![]() 9.4 Item 1(Picture) Occupant Door
|